PDF cuRUs - UL 60950-1, CSA 60950-1

Issue Date:
2011-11-18
Page 1 of 6
Report Reference #
E135493-A18-UL
2014-07-25
UL TEST REPORT AND PROCEDURE
Standard:
Certification Type:
CCN:
UL 60950-1, 2nd Edition, 2011-12-19 (Information Technology
Equipment - Safety - Part 1: General Requirements)
CSA C22.2 No. 60950-1-07, 2nd Edition, 2011-12 (Information
Technology Equipment - Safety - Part 1: General Requirements)
Component Recognition
QQGQ2, QQGQ8 (Power Supplies for Information Technology
Equipment Including Electrical Business Equipment)
Product:
Model:
AC-DC Converter
VI Brick AC Front End
Rating:
See Miscellaneous Enclosure for model matrix.
Input:
85-264Vac
47-63Hz
Output Voltage: 48Vdc
Output Power 330Wmax
See Miscellaneous Enclosure for model details.
Applicant Name and Address:
VICOR CORP
25 FRONTAGE RD
ANDOVER MA 01810-5499
UNITED STATES
This is to certify that representative samples of the products covered by this Test Report have been investigated in accordance with the
above referenced Standards. The products have been found to comply with the requirements covering the category and the products are
judged to be eligible for Follow-Up Service under the indicated Test Procedure. The manufacturer is authorized to use the UL Mark on
such products which comply with this Test Report and any other applicable requirements of UL LLC ('UL') in accordance with the FollowUp Service Agreement. Only those products which properly bear the UL Mark are considered as being covered by UL's Follow-Up
Service under the indicated Test Procedure.
The applicant is authorized to reproduce the referenced Test Report provided it is reproduced in its entirety.
UL authorizes the applicant to reproduce the latest pages of the referenced Test Report consisting of the first page of the Specific
Technical Criteria through to the end of the Conditions of Acceptability.
Any information and documentation involving UL Mark services are provided on behalf of UL LLC (UL) or any authorized licensee of UL.
Prepared by:
Gerard Soprych
Reviewed by: Daniel Pirozzi
Copyright © 2014
Issue Date:
2011-11-18
Page 2 of 6
Report Reference #
E135493-A18-UL
2014-07-25
Supporting Documentation
The following documents located at the beginning of this Procedure supplement the requirements of this Test
Report:
A. Authorization - The Authorization page may include additional Factory Identification Code markings.
B. Generic Inspection Instructions i. Part AC details important information which may be applicable to products covered by this Procedure.
Products described in this Test Report must comply with any applicable items listed unless otherwise
stated in the body of this Test Report.
ii. Part AE details any requirements which may be applicable to all products covered by this Procedure.
Products described in this Test Report must comply with any applicable items listed unless otherwise
stated in the body of each Test Report.
iii. Part AF details the requirements for the UL Certification Mark which is not controlled by the technical
standard used to investigate these products. Products are permitted to bear only the Certification
Mark(s) corresponding to the countries for which it is certified, as indicated in each Test Report.
Product Description
The VI Brick AC-DC front end modules are isolated AC-DC converters for building-in. The modules provide
power factor correction (PFC), operate over a wide input voltage range and provide SELV output.
Model Differences
See Miscellaneous Enclosure for model nomenclature.
Technical Considerations

Equipment mobility : for building-in

Connection to the mains : not directly connected to mains

Operating condition : continuous

Access location : building-in

Over voltage category (OVC) : OVC II

Mains supply tolerance (%) or absolute mains supply values : 85-264

Tested for IT power systems : No

IT testing, phase-phase voltage (V) : -

Class of equipment : Class I (earthed)

Considered current rating of protective device as part of the building installation (A) : 6.3 A or less

Pollution degree (PD) : PD 2

IP protection class : IP X0

Altitude of operation (m) : 5000

Altitude of test laboratory (m) : less than 2000

Mass of equipment (kg) : 0.11

The product was submitted and evaluated for use at the maximum ambient temperature (Tma)
permitted by the manufacturer’s specification of: case temperature of 100°C under normal operating
conditions
Issue Date:
2011-11-18
Page 3 of 6
Report Reference #
E135493-A18-UL
2014-07-25
Engineering Conditions of Acceptability
For use only in or with complete equipment where the acceptability of the combination is determined by UL
LLC. When installed in an end-product, consideration must be given to the following:

An external VDR and fuse are required in the end application. The VI Brick AC Front End was
evaluated with an external Littelfuse TMOV (VDR).

The VI Brick AC Front End was evaluated with an external fast acting fuse rated 6.3A. Littelfuse
216P series, Bussmann S501 series, and Schurter SA series.

The VI Brick AC Front End provides 1500 Vac / 2121 Vdc of isolation from input/output to EMI
GND/Heatsink (BI), 3000 Vac/ 4242 Vdc from Input to Output (RI), and 1500 Vac / 2121 Vdc of
isolation from Output to Heatsink (SI).

The maximum baseplate / heatsink temperature is 100°C. The heatsink may be grounded or floating
in the end application.

The following secondary output circuits are at hazardous energy levels: All

The power supply terminals and/or connectors are: Not investigated for field wiring

The investigated Pollution Degree is: 2

An investigation of the protective bonding terminals has: Not been conducted

The following end-product enclosures are required: Mechanical, Fire, Electrical

The following secondary output circuits are SELV: all.
Additional Information
N/A
Markings and instructions
Clause Title
1.7.1 Power rating Company identification
1.7.1 Power
rating - Model
Marking or Instruction Details
Listee's or Recognized company's name, Trade Name, Trademark or File
Number
Model Number
Special Instructions to UL Representative
N/A
Issue Date:
2011-11-18
Page 4 of 6
Report Reference #
2014-07-25
VI Brick AC Front End Model Number: FEbbbDcccsxxxyz-aa
Example: FE175D480C033FP-00
FE = Constant
Front End
bbb = Input Voltage (range) Vac
175 (85-264)
Universal
115 (85-132)
Low Range
230 (170-265)
High Range
D = Constant
Package size (Double)
ccc = Output Voltage Designator (can be any
three digits from 000 to 480) non-inclusive list
of examples below
480
48 Vdc
s=
C
T
M
Product Grade
Commercial
Telecom
Military
Temp Range
-20 - 100 C
-40 - 100 C
-55 - 100 C
xxx = Output Pow er Designator, non-inclusive
list of examples below
020
200 W
003
300 W
025
250 W
033
330 W
y = Baseplate Style, any alphanumeric
character, non-safety related, non-inclusive list
below
F
Slotted Flange
z = Pin Style, any alphanumeric character, nonsafety related, non-inclusive list below
P
Standard Length Through Hole
aa = Customer Reference or Revision, nonsafety related, any alphanumeric character
00
Standard Product
E135493-A18-UL