CINT1150 150W Single Output Industrial Series Features 2” x 4” x 1.3” Package For 1U Applications 150W w/air, 100W convection cooled Universal Input 90-264 VAC Power Fail/Output Good Signal Approved to CSA/EN/IEC/UL60950, 2nd Edition 3 Year Warranty RoHS Compliant Description The CINT1150 family is the latest offering in high density single output open-frame AC/DC power supplies. Approved to EN/IEC/UL60950-1, 2nd edition, the CINT1150 family is ideal for lighting, industrial printers, gaming equipment, and many other applications where power density and cost are critical. The CINT1150 operates at universal input range of 90 to 264Vac and wide temperature range -10°C to +70°C, delivering full rated output power up to +50°C. In addition, these models feature Power Fail and DC OK signals. Model Selection Model Number Volts CINT1150A1206K01 12V 12.5A CINT1150A2406K01 24V CINT1150A4806K01 CINT1150A5606K01 Notes: Output Current w/200LFM air Convection* Ripple & Noise** Total Regulation OVP Threshold*** 8.33A 0.5%RMS, 1.2% pk-pk ±5% 14.0 ± 1.1V 6.25A 4.17A 0.5%RMS, 1.0% pk-pk ±5% 28.0 ± 2.5V 48V 3.13A 2.08A 0.5%RMS, 1.0% pk-pk ±5% 55.0 ± 4.0V 56V 2.68A 1.79A 0.5%RMS, 1.0% pk-pk ±5% <59.9V * Maximum output power is 95 Watts for input voltage of 90-105VAC at 50°C convection. For input voltage of 105Vac or more, the total power is 100 Watts at 50°C convection. ** Measured with noise probe directly across output terminals, and load terminated with 0.1µF ceramic and 10µF low ESR capacitors. General Specifications AC Input Input Current Inrush Current Input Fuses www.slpower.com 100-240Vac, ±10%, 47-63Hz, 1∅ 120–370Vdc Turn On Time Less than 2 sec. @115Vac (inversely proportional to input voltage and thermistor temperature) 115Vac: 2A, 230Vac: 1A Hold-up Time >12mS at full load, 120Vac 264Vac, cold start: will not exceed 50A F1, F2: 4A, 250Vac fuses provided on all models Signals Overload Protection CINT1150 REV 2.7, 11-JUNE-13 AC Power Fail, DC OK Hiccup Mode 1 CINT1150 150W Single Output Industrial Series General Specifications (continued) Earth Leakage Current Efficiency Output Power Transient Response <750µA@264Vac, 60Hz, NC Short Circuit Protection Overvoltage Protection 88% typical at 115Vac 150W continuous with 200 lfm airflow, 100W convection cooled – See chart for specific voltage model ratings. Switching Frequency 50% load step. ∆i/∆t: <0.2A/µS Max Volt Deviation = 3% Isolation Provided - no damage will occur if the output is shorted. Hiccup Mode OVP firing reduces output voltage to <50% of nominal in <50mS. See chart for trip range. PFC: Variable 30-400kHz. Main Converter: Variable 35-180kHz, 6570kHz at full load. Input-Output: 4000Vac Input-Ground: 1800Vac Output-Ground: 500Vac Ripple and Noise See chart Operating Temperature -10°C to +70°C -40C Start Up Output Voltage See chart Temperature Derating Derate output power linearly above 50°C to 50% at 70°C Voltage Adjustability Minimum Load Total Regulation Vibration Dimensions Weight Storage Temperature +/-5% from nominal Altitude Not required Relative Humidity +/- 5%. See chart Operating: 0.003g/Hz, 1.5grms overall, 3 axes, 10 min/axis Non-Operating: 0.026g2/Hz, 5.0grms overall, 3 axes, 1 hr/axis Shock Safety Standards W: 2.0” x L: 4.0” x H: 1.3” MTBF 183g -40°C to +85°C Operating: -500 to 10,000 ft Non-operating: -500 to 40,000 ft. 5% to 95%, non-condensing Operating: Half-sine, 20gpk, 10ms, 3 axes, 6 shocks total Non-Operating: Half-sine, 40 gpk, 10 ms, 3 axes, 6 shocks total EN/CSA/UL/IEC60950-1, 2nd Edition 640,000 hours at 100W convection, 1,500,000 hours at 150W with 200LFM air Auxiliary Signals AC Power Fail: During normal operations, stays HIGH. Power Fail: DC OK: www.slpower.com CINT1150 REV 2.7, 11-JUNE-13 Goes LOW with 5 mS warning before loss of output power due to AC failure Open collector logic signal goes and stays HIGH 100mS to 500mS after main output reaches regulation. 2 CINT1150 150W Single Output Industrial Series EMI/EMC Compliance Conducted Emissions EN55011/22 Class B, FCC Part 15, Subpart B, Class B Radiated Emissions EN55011/22 Class A, FCC Part 15, Subpart B, Class A w/6db margin Static Discharge Immunity EN61000-4-2, Criteria A, 6kV Contact Discharge, 8kV air discharge Radiated RF Immunity EN61000-4-3, 3V/m. Criteria A EFT/Burst Immunity EN61000-4-4, 2kV/5kHz, Criteria A Line Surge Immunity EN61000-4-5, 1kV differential, 2kV common-mode, Criteria A Conducted RF Immunity EN61000-4-6, 3Vrms, Criteria A Power Frequency Magnetic Field Immunity EN61000-4-8, 3A/m, Criteria A Voltage Dip Immunity EN61000-4-11, 0% Vin, 0.5cycle; 40% Vin, 5 cycles; 70% Vin, 25 cycles; Criteria A Line Harmonic Emissions EN61000-3-2, Class A, B, C, & D Flicker Test EN61000-3-3, Complies (dmax<6%) Mechanical Drawing www.slpower.com CINT1150 REV 2.7, 11-JUNE-13 3 CINT1150 150W Single Output Industrial Series Connector Information Input Connector J100 Ground J101 DC Output Connector J200 Signal Connector J300 PIN 1) AC LINE PIN 2) EMPTY PIN 3) AC NEUTRAL 0.187” FASTON TAB PIN 1) +Vout PIN 4) -Vout PIN 2) +Vout PIN 5) -Vout PIN 3) +Vout PIN 6) -Vout PIN 1) PF/DC OK PIN 2) Common Mating Connector: Molex 09-50-3031 Pins= 08-52-0072 Mating Connector: Molex 01-90020009 Mating Connector: AMP 640250-6 Pins = 640252-1 Mating Connector: Molex 1375820-2 Pins = 1375819 Power Fail/DC OK Signals – J300 J300–Pin 1 J300 – Pin 2 AC POWER FAIL SIGNAL DC OK SIGNAL Isolation Specifications Parameter Conditions/Description Insulation Safety Rating Input/Ground Input/Output Output/Ground Electric Strength Test Voltage Input/Ground Input/Output Output/Ground www.slpower.com CINT1150 REV 2.7, 11-JUNE-13 Min Nom Max Units - Vac Vac Vac Basic Reinforced n/a 1800 4000 500 - 4 CINT1150 150W Single Output Industrial Series Input Specifications All specifications apply over specified input voltage, output load, and temperature range, unless otherwise noted. Parameter Conditions/Description Input Voltage Min Nom Max Units 90 115/230 264 Vac Turn-On Input Voltage Ramping up 82.7 Vac Turn-Off Input Voltage Ramping down 67.0 Vac Input Frequency 47 50/60 63 Hz 264Vac, cold start - - 50 A Power Factor Vi nom, Io nom 0.9 - - Efficiency Vi nom, Io nom CINT1150A1206K01 CINT1150A2406K01 CINT1150A4806K01 CINT1150A5606K01 - 88% - % Max Units 2 KV (CM) Inrush Current Limitation Protection All specifications apply over specified input voltage, output load, and temperature range, unless otherwise noted Parameter Conditions/Description Input Fuse Not user accessible Input Transient Protection 2KV(CM) and 1KV(DM) surge Min Nom No-load Hiccup Mode Short Circuit Hiccup Mode Overload Hiccup Mode Overvoltage Protection Latch style See Models chart for trip ranges Over temperature Protection Automatic power shutdown at TC =155°C Output Characteristic Curves Output vs. Temperature 100W convection cooled and 150W continuous with 200 LFM airflow, Derating output power to 50% at 70°C. www.slpower.com CINT1150 REV 2.7, 11-JUNE-13 5 CINT1150 150W Single Output Industrial Series Efficiency vs. Loading The high efficiency is achieved by using LLC technology, PFC topology minimizing switching losses. Synchronous SCHOTTKY or ultra-fast diode is used as rectifier in CINT1150 family because of high output voltage level. Ripple & Noise To verify that the output ripple and noise does not exceed the level specified in the product specification. Measured using a scope probe socket with 0.1uF ceramic and a 10uF electrolytic capacitor connected in parallel across it, 20MHz BW. www.slpower.com 24V OUT, NO LOAD, 90VAC, 60HZ 24V OUT, FULL LOAD, 90VAC, 60HZ 24V OUT, NO LOAD, 264VAC, 50HZ 24V OUT, FULL LOAD, 264VAC, 50HZ CINT1150 REV 2.7, 11-JUNE-13 6 CINT1150 150W Single Output Industrial Series Output Transient Response 50% load step within the regulation limits of minimum and maximum load, dI/dt< 0.2A/µSec. Recovery time not specified as there is no laps in regulation with a 50% Load Step. Maximum voltage deviation is 3%, This test is performed on the MAIN OUTPUT ONLY. 24V OUT, 120VAC, 25% TO 75% LOAD STEP 24V OUT, 240VAC, 25% TO 75% LOAD STEP Output Overload Characteristic Supply shall protect itself against Overload conditions. The Power Supply shall recover from Overload Conditions without operator intervention. 24V OUT, 90VAC 24V OUT, 264VAC Short Circuit Protection Supply shall protect itself against Short Circuit conditions. No damage will occur if the output is shorted.. 24V OUT, 90VAC www.slpower.com 24V OUT, 264VAC CINT1150 REV 2.7, 11-JUNE-13 7 CINT1150 150W Single Output Industrial Series Overvoltage Protection OVP firing reduces output voltage to <50% of nominal in <50ms. See models chart for trip ranges. 24V OUT, NO LOAD 24V OUT, FULL LOAD Turn On Time 90VAC, FULL LOAD 264VAC, FULL LOAD Hold Up Time 120VAC, FULL LOAD Data Sheet © 2012 SL Power Electronics Corp. The information and specifications contained herein are believed to be correct at the time of publication. However, SL Power accepts no responsibility for consequences arising from reproduction errors or inaccuracies. Specifications are subject to change without notice. www.slpower.com CINT1150 REV 2.7, 11-JUNE-13 8