GB60 Series - SL Power Electronics

GB60S
60W Single Output
General Purpose
Features
2” x 3” x 1.0” Package
For 1U Applications
60W convection cooled
Universal Input 90-264Vac
Optional Power ON LED
Approved to CSA/EN/IEC/UL60950-1,
2nd Edition
Level V Efficiency Compliant Models
Less than 0.5W no-load Power Consumption
3 Year Warranty
RoHS Compliant
Description
The GB60S Series models provide a highly reliable power source in high density 2” x 3” x 1.0” package.
Fully compliant to the applicable safety and EMC standards, these models will allow easy integration into many
industrial and ITE applications. All 4 models are CE marked to low voltage directive and approved to ITE
standards of EN60950, 2nd edition.
Model Selection
Notes:
Model
Number*
Volts
Output Current
Convection Cooled
Output Power
Convection Cooled
Ripple &
Noise**
Total
Regulation
OVP
Threshold
GB60S12K
12V
4.58A
55W
120mV pk-pk
±2%
14.4-18Vdc
GB60S15K
15V
4.00A
60W
150mV pk-pk
±2%
18-22.5Vdc
GB60S24K
24V
2.50A
60W
240mV pk-pk
±2%
28.8-36Vdc
GB60S36K
36V
1.67A
60W
360mV pk-pk
±2%
43.2-54Vdc
GB60S48K
48V
1.25A
60W
480mV pk-pk
±2%
57.6-72Vdc
* Models with 24V or higher output voltage meet efficiency requirements of Level V
** Measured with noise probe directly across output terminals, and load terminated with 0.1µF ceramic and 10µF low ESR capacitors. At -20C, the noise and ripple
is 2% of the output.
General Specifications
AC Input
Input Current
Inrush Current
Input Fuses
www.slpower.com
100-240Vac, 47-63Hz, 1∅ rated
80–270Vac, 47-440Hz operational
Turn On Time
2 sec. max. @120Vac
120Vac: 1.4A, 240Vac: 0.75A
Hold-up Time
16mS min. @ 60W load, 120Vac input
240Vac, cold start: will not exceed 40A
4A, 250VAC fuse provided on all models
GB60S 18-DEC-14
Signals
Overload
Protection
Optional Power ON LED
Hiccup Mode, 120% to 180%, typical
1
GB60S
60W Single Output
General Purpose
General Specifications (continued)
Earth Leakage
Current
Power Factor
Efficiency
Output Power
Peak Output
Power
Ripple and Noise
Output Voltage
Voltage
Adjustability
Minimum Load
Total Regulation
Transient
Response
Switching
Frequency
Dimensions
Short Circuit
Protection
<1mA@240Vac, NC
Hiccup Mode
Not Applicable
Overtemperature
Protection
Self-recovering
88% typical (83% for 12V& 85% for 15V)
Safety Standards
CSA/EN/IEC/UL60950-1, 2nd Edition. See below
for detailed standards information.
Isolation
60W continuous (55W for 12V models)
Operating
Temperature
Not Applicable
Output Power
Derating
See chart above
Storage
Temperature
See chart
Relative Humidity
Fixed
Altitude
Not required
MTBF
+/- 2%. See chart
500µS max. to 1%, 50% load step. 0.2A/µS,
3.5% deviation typical
Vibration
Shock
65kHz, typical
2.0” x 3.0” x 1.0”
50.8 x 76.2 x 25.4mm
Weight
Input-Output: 4000Vac
Input-Ground: 1800Vac
Output-Ground: 500Vac
-40C start up. -20C to 80C with derating
specified in Fig.1
See Fig.1 on page 4
-40°C to +85°C
5% to 95%, non-condensing
Operating: 3000 meters
Non-operating: 40,000 ft.
Over 600,000 hours per Telcordia
Random Vibration per MIL-STD-810E, Method
514.4, Cat. 1, Figure 514.4.1, 1 hour in each of 3
axes.
Half-sine, 40 gpk, 10 mS duration, +/- in each of
3 axes, 6 shocks total
126g
Notes:
1. Specifications subject to change without notice.
2. All dimensions in inches (mm), tolerance is ±.02”.
3. Mounting holes should be connected together for EMI purpose
4. FG is safety ground connection
5. Specifications are for convection rating at factory settings with 115Vac input and 25°C ambient unless otherwise stated.
6. This power supply requires mounting on metal standoffs 0.20” (5mm) in height.
www.slpower.com
GB60S 18-DEC-14
2
GB60S
60W Single Output
General Purpose
EMI/EMC Compliance
Conducted Emissions
EN55011/22 Class B, FCC Part 15 Class B
Radiated Emissions
EN55011/22 Class A, FCC Part 15 Class A with 6dB margin
Static Discharge Immunity
EN61000-4-2, 6kV Contact Discharge, 8kV air discharge
Radiated RF Immunity
EN61000-4-3, 3V/m
EFT/Burst Immunity
EN61000-4-4, 2kV/5kHz
Line Surge Immunity
EN61000-4-5, 1kV differential, 2kV common-mode
Conducted RF Immunity
EN61000-4-6, 3Vrms
Power Frequency Magnetic Field Immunity
EN61000-4-8, 3A/m
Voltage Dip Immunity
EN61000-4-11 100Vac, 95% dip/0.5 cycle (Criteria A), 60%/5cycles
(Criteria B), 30%/25 cycles (Criteria A).
Line Harmonic Emissions
EN61000-3-2 Class A
Flicker Test
EN61000-3-3, Complies (dmax<6%)
Mechanical Drawing
Connector Information
Input Connector
J100
PIN 1) AC LINE
PIN 2) EMPTY
PIN 3) AC
NEUTRAL
Mating Connector:
Tyco/AMP 6402503
Pins = 770461-1
www.slpower.com
DC Output Connector
J2
Ground
PIN 1) +Vout PIN
3) -Vout
PIN 2) +Vout PIN
4) -Vout
19-30258-0187
(Keystone
1285)(Zierick
895)(.187*0.020)
Mating Connector:
AMP 640250-4
Pins = 770461-1
Molex 01-90020005
GB60S 18-DEC-14
3
GB60S
60W Single Output
General Purpose
Characteristic Curves
Output vs. Temperature
-40C start up. At -20C, the supply meet its full spec except ripple & noise might be increased from 1% to 2% of the output voltage
55W convection cooled, derating output power to 30W at 70°C for outputs 12V and 15V
60W convection cooled, derating output power to 50W at 60°C and 40W at 70°C for Output Voltages ≥ 24V
20W convection cooled at 80C
Convection
for 12V
Model
70
50
30
10
-10
0
10
20
30
40
50
60
70
80
Output
Power(W)
Output Power vs . Temperature
Temperature (°
°C)
Fig.1
Efficiency vs. Loading
Efficiency vs. Output Power
Efficiency (%)
100.0%
90.0%
80.0%
70.0%
60
45
30
15
6
Output Power (W)
120Vac
240Vac
Fig.2
www.slpower.com
GB60S 18-DEC-14
4
GB60S
60W Single Output
General Purpose
Ripple & Noise
To verify that the output ripple and noise does not exceed the level specified in the product specification, measured using a scope probe socket with
0.1uF ceramic and a 10uF electrolytic capacitor connected in parallel across it, 20MHz BW.
24V OUT, NO LOAD, 90VAC, 60HZ
24V OUT, FULL LOAD, 90VAC, 60HZ
24V OUT, NO LOAD, 264VAC, 50HZ
www.slpower.com
24V OUT, FULL LOAD, 264VAC, 50HZ
GB60S 18-DEC-14
5
GB60S
60W Single Output
General Purpose
Output Transient Response
50% load step within the regulation limits of minimum and maximum load, dI/dt< 0.2A/µSec. Recovery time not specified as there is no laps in regulation
with a 50% Load Step. Maximum voltage deviation is 3.5%
24V OUT, 120VAC, 25% TO 75% LOAD STEP
24V OUT, 240VAC, 25% TO 75% LOAD STEP
Output Overload Characteristic
24V OUT, 90VAC
24V OUT, 264VAC
Short Circuit Protection
Supply shall protect itself against Short Circuit conditions. No damage will occur if the output is shorted.
24V OUT, 90VAC
24V OUT, 264VAC
www.slpower.com
GB60S 18-DEC-14
6
GB60S
60W Single Output
General Purpose
Overvoltage Protection
OVP firing reduces output voltage to <50% of nominal in <50ms. See models chart for trip ranges.
24V OUT, FULL LOAD, 90VAC, 60HZ
24V OUT, FULL LOAD, 264VAC, 50HZ
Turn On Time
24V OUT, FULL LOAD, 90VAC, 60HZ
24V OUT, FULL LOAD, 264VAC, 50HZ
Hold Up Time
24V OUT, FULL LOAD, 120VAC, 60HZ
Data Sheet © 2014 SL Power Electronics Corp. The information and specifications contained herein are believed to be correct at the time of publication.
for consequences arising from reproduction errors or inaccuracies. Specifications are subject to change without notice.
www.slpower.com
GB60S 18-DEC-14
However, SL Power accepts no responsibility
7