GB60S 60W Single Output General Purpose Features 2” x 3” x 1.0” Package For 1U Applications 60W convection cooled Universal Input 90-264Vac Optional Power ON LED Approved to CSA/EN/IEC/UL60950-1, 2nd Edition Level V Efficiency Compliant Models Less than 0.5W no-load Power Consumption 3 Year Warranty RoHS Compliant Description The GB60S Series models provide a highly reliable power source in high density 2” x 3” x 1.0” package. Fully compliant to the applicable safety and EMC standards, these models will allow easy integration into many industrial and ITE applications. All 4 models are CE marked to low voltage directive and approved to ITE standards of EN60950, 2nd edition. Model Selection Notes: Model Number* Volts Output Current Convection Cooled Output Power Convection Cooled Ripple & Noise** Total Regulation OVP Threshold GB60S12K 12V 4.58A 55W 120mV pk-pk ±2% 14.4-18Vdc GB60S15K 15V 4.00A 60W 150mV pk-pk ±2% 18-22.5Vdc GB60S24K 24V 2.50A 60W 240mV pk-pk ±2% 28.8-36Vdc GB60S36K 36V 1.67A 60W 360mV pk-pk ±2% 43.2-54Vdc GB60S48K 48V 1.25A 60W 480mV pk-pk ±2% 57.6-72Vdc * Models with 24V or higher output voltage meet efficiency requirements of Level V ** Measured with noise probe directly across output terminals, and load terminated with 0.1µF ceramic and 10µF low ESR capacitors. At -20C, the noise and ripple is 2% of the output. General Specifications AC Input Input Current Inrush Current Input Fuses www.slpower.com 100-240Vac, 47-63Hz, 1∅ rated 80–270Vac, 47-440Hz operational Turn On Time 2 sec. max. @120Vac 120Vac: 1.4A, 240Vac: 0.75A Hold-up Time 16mS min. @ 60W load, 120Vac input 240Vac, cold start: will not exceed 40A 4A, 250VAC fuse provided on all models GB60S 18-DEC-14 Signals Overload Protection Optional Power ON LED Hiccup Mode, 120% to 180%, typical 1 GB60S 60W Single Output General Purpose General Specifications (continued) Earth Leakage Current Power Factor Efficiency Output Power Peak Output Power Ripple and Noise Output Voltage Voltage Adjustability Minimum Load Total Regulation Transient Response Switching Frequency Dimensions Short Circuit Protection <1mA@240Vac, NC Hiccup Mode Not Applicable Overtemperature Protection Self-recovering 88% typical (83% for 12V& 85% for 15V) Safety Standards CSA/EN/IEC/UL60950-1, 2nd Edition. See below for detailed standards information. Isolation 60W continuous (55W for 12V models) Operating Temperature Not Applicable Output Power Derating See chart above Storage Temperature See chart Relative Humidity Fixed Altitude Not required MTBF +/- 2%. See chart 500µS max. to 1%, 50% load step. 0.2A/µS, 3.5% deviation typical Vibration Shock 65kHz, typical 2.0” x 3.0” x 1.0” 50.8 x 76.2 x 25.4mm Weight Input-Output: 4000Vac Input-Ground: 1800Vac Output-Ground: 500Vac -40C start up. -20C to 80C with derating specified in Fig.1 See Fig.1 on page 4 -40°C to +85°C 5% to 95%, non-condensing Operating: 3000 meters Non-operating: 40,000 ft. Over 600,000 hours per Telcordia Random Vibration per MIL-STD-810E, Method 514.4, Cat. 1, Figure 514.4.1, 1 hour in each of 3 axes. Half-sine, 40 gpk, 10 mS duration, +/- in each of 3 axes, 6 shocks total 126g Notes: 1. Specifications subject to change without notice. 2. All dimensions in inches (mm), tolerance is ±.02”. 3. Mounting holes should be connected together for EMI purpose 4. FG is safety ground connection 5. Specifications are for convection rating at factory settings with 115Vac input and 25°C ambient unless otherwise stated. 6. This power supply requires mounting on metal standoffs 0.20” (5mm) in height. www.slpower.com GB60S 18-DEC-14 2 GB60S 60W Single Output General Purpose EMI/EMC Compliance Conducted Emissions EN55011/22 Class B, FCC Part 15 Class B Radiated Emissions EN55011/22 Class A, FCC Part 15 Class A with 6dB margin Static Discharge Immunity EN61000-4-2, 6kV Contact Discharge, 8kV air discharge Radiated RF Immunity EN61000-4-3, 3V/m EFT/Burst Immunity EN61000-4-4, 2kV/5kHz Line Surge Immunity EN61000-4-5, 1kV differential, 2kV common-mode Conducted RF Immunity EN61000-4-6, 3Vrms Power Frequency Magnetic Field Immunity EN61000-4-8, 3A/m Voltage Dip Immunity EN61000-4-11 100Vac, 95% dip/0.5 cycle (Criteria A), 60%/5cycles (Criteria B), 30%/25 cycles (Criteria A). Line Harmonic Emissions EN61000-3-2 Class A Flicker Test EN61000-3-3, Complies (dmax<6%) Mechanical Drawing Connector Information Input Connector J100 PIN 1) AC LINE PIN 2) EMPTY PIN 3) AC NEUTRAL Mating Connector: Tyco/AMP 6402503 Pins = 770461-1 www.slpower.com DC Output Connector J2 Ground PIN 1) +Vout PIN 3) -Vout PIN 2) +Vout PIN 4) -Vout 19-30258-0187 (Keystone 1285)(Zierick 895)(.187*0.020) Mating Connector: AMP 640250-4 Pins = 770461-1 Molex 01-90020005 GB60S 18-DEC-14 3 GB60S 60W Single Output General Purpose Characteristic Curves Output vs. Temperature -40C start up. At -20C, the supply meet its full spec except ripple & noise might be increased from 1% to 2% of the output voltage 55W convection cooled, derating output power to 30W at 70°C for outputs 12V and 15V 60W convection cooled, derating output power to 50W at 60°C and 40W at 70°C for Output Voltages ≥ 24V 20W convection cooled at 80C Convection for 12V Model 70 50 30 10 -10 0 10 20 30 40 50 60 70 80 Output Power(W) Output Power vs . Temperature Temperature (° °C) Fig.1 Efficiency vs. Loading Efficiency vs. Output Power Efficiency (%) 100.0% 90.0% 80.0% 70.0% 60 45 30 15 6 Output Power (W) 120Vac 240Vac Fig.2 www.slpower.com GB60S 18-DEC-14 4 GB60S 60W Single Output General Purpose Ripple & Noise To verify that the output ripple and noise does not exceed the level specified in the product specification, measured using a scope probe socket with 0.1uF ceramic and a 10uF electrolytic capacitor connected in parallel across it, 20MHz BW. 24V OUT, NO LOAD, 90VAC, 60HZ 24V OUT, FULL LOAD, 90VAC, 60HZ 24V OUT, NO LOAD, 264VAC, 50HZ www.slpower.com 24V OUT, FULL LOAD, 264VAC, 50HZ GB60S 18-DEC-14 5 GB60S 60W Single Output General Purpose Output Transient Response 50% load step within the regulation limits of minimum and maximum load, dI/dt< 0.2A/µSec. Recovery time not specified as there is no laps in regulation with a 50% Load Step. Maximum voltage deviation is 3.5% 24V OUT, 120VAC, 25% TO 75% LOAD STEP 24V OUT, 240VAC, 25% TO 75% LOAD STEP Output Overload Characteristic 24V OUT, 90VAC 24V OUT, 264VAC Short Circuit Protection Supply shall protect itself against Short Circuit conditions. No damage will occur if the output is shorted. 24V OUT, 90VAC 24V OUT, 264VAC www.slpower.com GB60S 18-DEC-14 6 GB60S 60W Single Output General Purpose Overvoltage Protection OVP firing reduces output voltage to <50% of nominal in <50ms. See models chart for trip ranges. 24V OUT, FULL LOAD, 90VAC, 60HZ 24V OUT, FULL LOAD, 264VAC, 50HZ Turn On Time 24V OUT, FULL LOAD, 90VAC, 60HZ 24V OUT, FULL LOAD, 264VAC, 50HZ Hold Up Time 24V OUT, FULL LOAD, 120VAC, 60HZ Data Sheet © 2014 SL Power Electronics Corp. The information and specifications contained herein are believed to be correct at the time of publication. for consequences arising from reproduction errors or inaccuracies. Specifications are subject to change without notice. www.slpower.com GB60S 18-DEC-14 However, SL Power accepts no responsibility 7