ZEN-PA03024

Switching Mode Power Supply
ZEN-PA03024
CSM_ZEN-PA03024_DS_E_3_1
New Compact Power Supply (30 W) for ZEN
Programmable Relays
• Slim size with a depth of 56 mm (W × H × D: 70 × 90 × 56 mm).
• EMI: Conforms to EN61000-6-3 (Class B).
• Allows parallel operation.
• Safety standards: UL508/UL60950-1/UL1604,
CSA C22.2 No. 14/No.60950-1/
No.213 (Evaluated by UL),
EN60950-1 (VDE 0805 Teil 1),
EN50178 (VDE0160)
• Output voltage: 24 VDC; Output current: 1.3 A; Capacity: 30 W
• Uses lead-free soldering.
Refer to Safety Precautions on page 6
Model Number Structure
■ Model Number Legend
ZEN-PA 030 24
1
2
3
1. Unit
PA: Power supply unit
2. Power Ratings
030: 30 W
3. Output voltage
24: 24 V
Ordering Information
■ List of Models
Power ratings
30 W
Input voltage
100 to 240 VAC
Output voltage
24 VDC
Output current
1.3 A
Model number
ZEN-PA03024
■ Accessories (Order Separately)
Name
Mounting Track
50 cm (l) × 7.3 mm (t)
Models
PFP-50N
1 m (l) × 7.3 mm (t)
PFP-100N
1 m (l) × 16 mm (t)
PFP-100N2
End Plate
PFP-M
Spacer
PFP-S
1
ZEN-PA03024
Specifications
■ Ratings/Characteristics
Efficiency (typical)
80% min.
Input
100 to 240 VAC (85 to 264 VAC),
95 to 350 VDC (See note 1.)
Voltage
Frequency
Current
Leakage current
50/60 Hz (47 to 450 Hz)
100 VAC input
0.45 A max.
100 VAC input
0.4 mA max.
200 VAC input
Inrush current (See note 2.) 100 VAC input
200 VAC input
Output
0.8 A max.
200 VAC input
Voltage adjustment range (See note 3.)
0.75 mA max.
25 A max.
50 A max.
−10 to 15% (with V.ADJ) of rated output voltage
Ripple
2% (p-p) max. (−25 to −10°C: 4% max.)
Input variation influence
0.5% max.
Load variation influence (rated input voltage) 1.5% max.
Temperature variation influence
0.05%/°C max.
Start up time (See note 2.)
1,000 ms max. (100 VAC or 200 VAC, at rated output voltage)
Hold time (See note 2.)
15 ms min., 20 ms (typical) (100 VAC or 200 VAC, at rated output voltage)
Additional
functions
Overload protection (See note 2.)
105% to 135% of rated load current, inverted L drop, intermittent, automatic reset
Parallel operation
Yes (2 units max. For details, refer to the derating curve in Engineering Data on page
4. For DC input, parallel operation is possible only for 110 to 350 VDC.)
Series operation
No
Others
Ambient temperature
Operating: Refer to the derating curve in Engineering Data on page 4. (with no icing
or condensation)
Storage: −25 to 75°C (with no icing or condensation)
Ambient humidity
Operating: 10 to 90%
Storage: 10 to 90%
Mounting method
DIN track mounting, surface mounting
Dielectric strength
2.0 kVAC for 1 min. (between all inputs and exposed non-current-carrying metal parts;
detection current: 10 mA max.)
3.0 kVAC for 1 min. (between all inputs and all outputs; detection current: 20 mA max.)
1.0 kVAC for 1 min. (between all outputs and non-current-carrying metal parts;
detection current: 10 mA max.)
Insulation resistance
100 MΩ min. (between all outputs and all inputs/exposed non-current-carrying metal
parts) at 500 VDC
Vibration resistance
10 to 55 Hz, 0.375-mm single amplitude for 2 h each in X, Y, and Z direction
Shock resistance
300 m/s2, 3 times each in ±X, ±Y, ±Z directions
Yes (color: green)
Output indicator
EMI
Conducted
emissions
Conforms to EN61000-6-3 (Class B)
Radiated
emissions
Conforms to EN61000-6-3 (Class B)
Approved standards
UL: UL508 (listing, Class 2: Per UL1310), UL60950-1, UL1604 (Class I/Division 2)
cUL: CSA C22.2 No. 14 (listing, Class2: Per CSA C22.2 No. 223), CSA C22.2 No. 213
(Class I/Division 2)
cUR: CSA C22.2 No.60950-1
EN/VDE: EN60950-1 (=VDE 0805 Teil 1), EN50178 (=VDE 0160)
Weight
240 g max.
Note: 1. This product has been approved for safety standards only when an AC input is used. It has not been approved when a DC input is used.
2. Refer to the Engineering Data section on page 4 for details.
3. If the V. ADJ adjuster is turned, the voltage will increase by more than 15% of the voltage adjustment range.
Check the output voltage of the power supply when converting the output voltage, and make sure that the load will not be damaged.
2
ZEN-PA03024
Connections
■ Block Diagram
ZEN-PA03024
Fuse 2A
+V
L1
INPUT
DC OUTPUT
Noise filter
−V
L2/N
Rectifier/
Inrush current
protection circuit smoothing
circuit
Rectifier/
smoothing
circuit
Drive control
circuit
Overcurrent
circuit
Current
detection circuit
Overvoltage
detection circuit
Photocoupler
Note: The Power Supply is provided with reinforced insulation between the input and output terminals.
■ Installation
No.
Name
Function
1
AC input terminal (L1)
Connect the input line to this terminal. A fuse is included in the circuit.
2
AC input terminal (L2/N) Connect the input line to this terminal. Negative pole for DC input.
3
DC output terminals (+V) Connect the load lines to these terminals.
4
DC output terminals (−V) Connect the load lines to these terminals.
5
Output indicator
(DC ON: Green)
6
Output voltage adjuster Use to adjust the voltage.
(V.ADJ)
Lights while a direct current (DC)
output is ON.
3
ZEN-PA03024
Engineering Data
■ Derating Curve
■ Overload Protection
Load (%)
85 to 264 VAC or 110 to 350 VDC input
120
(1)
100
The Power Supply is provided with an overload protection function
that protects the load and the power supply from possible damage by
overcurrent. When the output current rises above 105% min. of the
rated current, the protection function is triggered, decreasing the output voltage. When the output current falls within the rated range, the
overload protection function is automatically cleared.
(Reference value)
For parallel
operation
(See note 1.)
60
40
Output voltage (V)
80
(2)
20
0
−30 −20 −10
−25
0
20 30 40 50 60
45 55
Ambient Temperature (°C)
10
Load (%)
95 to 110 VDC input
Intermittent operation
120
0
50
100
100
Output current (%)
The values shown in the above diagrams are for reference only.
(1)
80
Note: 1. Internal parts may occasionally deteriorate or be damaged
if a short-circuited or overcurrent state continues during operation.
2. Internal parts may possibly deteriorate or be damaged if the
Power Supply is used for applications with frequent inrush
current or overloading at the load end. Do not use the Power
Supply for such applications.
60
40
(2)
20
0
−30 −20 −10
−25
0
10
20 30 40 50 60
55
Ambient Temperature (°C)
Note: 1. The maximum ambient temperature for parallel operation is
45°C.
2. Parallel operation is not possible for an input of 95 to
110 VDC.
3. Although operation is possible in the (2) portion of the derating curve, performance may be adversely affected, i.e.,
ripple noise may increase.
4. Internal parts may occasionally deteriorate or be damaged.
Do not use the Power Supply in areas outside the derating
curve (i.e., the area shown by shading (1) in the above
graph).
■ Inrush Current, Start Up Time,
Hold Time
Input OFF
Input ON
AC input
voltage
Inrush current on input application
AC input
current
Installation
Correct
90%
96.5%
Incorrect
Output
voltage
Start up time (1,000 ms max.)
Hold time (15 ms min.)
Standard mounting
Face-up mounting
Note: 1. Improper mounting will interfere with heat dissipation and
may occasionally result in deterioration or damage of internal parts. Use the standard mounting.
2. If there is a derating problem, use forced air-cooling. The
ambient temperature is specified for a point 50 mm below
the Power Supply.
4
ZEN-PA03024
Dimensions
Note: All units are in millimeters unless otherwise indicated.
ZEN-PA03024
Surface Mounting Holes
Two, M4
90
45
80
80
60
4.7
(Sliding: 13 max.)
60
44
70
56
■ Accessories (Order Separately)
Mounting Track
PFP-100N, PFP-50N
PFP-100N2
16
7.3±0.15
4.5
4.5
15 25
25
25
25
10
1,000 (500)*
35±0.3
27±0.15
35±0.3
15
1
10
25
25 15
25
25
10
1,000
27
24
1
10
29.2
1.5
* The value shown in parentheses is for the PFP-50N.
End Plate
PFP-M
10
6.2
Spacer
PFP-S
16
12
5
1.8
1
50
1.8
11.5
35.5 35.3
34.8
44.3
1.3
10 M4 x 8
pan head
screw
4.8
16.5
5
ZEN-PA03024
Safety Precautions
Refer to Safety Precautions for All Timers.
Wiring
!CAUTION
Minor electric shock may occasionally occur. Do not disassemble
the product or touch internal parts.
Minor fires may occasionally occur. Do not attempt to repair or
modify the product.
Minor burns may occasionally occur. Do not touch the product
while power is being supplied or immediately after power is
turned OFF.
Minor fires may occasionally occur. Tighten terminal screws to a
torque of 0.5 to 0.6 N·m so that they do not become loose.
Minor electric shock may occasionally occur during operation. Do
not touch the input and output terminals while power is being
supplied.
The product may occasionally be damaged. Do not allow any
clippings or cuttings to enter the product during installation work.
Working voltage can be 350 V max. inside. This voltage can be
also available 10 s after the switch off.
■ Precautions for Safe Use
The following precautions must be observed to ensure safety.
Mounting
• Mounting Direction
(Refer to Installation in Engineering Data on page 4.)
Standard Mounting
Valid
Horizontal Mounting
Invalid
Other Mounting
Invalid
Use solid wires. Always attach pin crimp terminals when using
stranded wire. The stripping distance should be 6.5 mm.
Recommended Wire Type
Solid wire
Cross section 0.5 to 2.5 mm2
(Equivalent to AWG20 to AWG14)
Stranded wire
Cross section 0.5 to 2.5 mm2
(Equivalent to AWG20 to AWG14)
Pin crimp terminals
Dia.: 1.1 to 2.3 mm
• Do not apply more than 100 N force to the terminal block when
tightening the terminals.
• Be sure to remove the sheet covering the product before turning
ON the Power Supply and confirm that nothing is interfering with
heat dissipation.
Installation Environment
• Do not use the Power Supply in locations subject to shocks or
vibrations. In particular, install the Power Supply as far away as
possible from contactors or other devices that are a vibration
source.
• Install the Power Supply well away from any sources of strong,
high-frequency noise.
Operating and Storage Conditions
The internal parts may occasionally deteriorate or be broken due to
adverse heat dissipation depending on the mounting status. Do not
use the product in any way other than the standard mounting
direction.
• Mounting Space
Make sure that sufficient heat dissipation is provided when
installing the Power Supply to increase its long-term reliability.
Install the product in a location that allows a natural airflow to occur
around the Power Supply.
We recommend using End Plates (PFP-M) to secure the Power
Supply and to ensure that a space of at least 10 mm is maintained
between Power Supplies.
If the installation space above and below the Power Supply is less
than 50 mm, reduce the ambient temperature by 5°C. A minimum
space of 20 mm is required.
ZEN-PA03024
(See note 2.)
• Minor fire may possibly occur. Ensure that input and output
terminals are wired correctly.
• Use the following material for the wires to be connected to the
Power Supply to prevent smoking or ignition caused by abnormal
loads.
(See note 1.)
• When installing the Power Supply, check for any signs that the
product or packaging has been struck. If internal parts have been
damaged, overvoltages may be output depending on the location of
the damage.
• Internal parts may occasionally deteriorate or be damaged. Store
the Power Supply at a temperature of −25 to 65°C and a humidity of
10% to 90%.
• Internal parts may occasionally deteriorate or be damaged. Do not
use the Power Supply in areas outside the derating curve (i.e., the
area shown by shading (1) in the graph on page 4). For UL508
Listing, the surrounding air temperature should be 40°C.
• Use the Power Supply at a humidity of 10% to 90%.
• Do not use the Power Supply in locations where condensation may
occur due to high humidity or where temperature changes are
severe.
• Do not use the Power Supply in locations subject to direct sunlight.
• Do not use the Power Supply in locations where liquids, foreign
matter, or corrosive gases may enter the interior of products.
Overload Protection
• Internal parts may possibly deteriorate or be damaged if a shortcircuited or overcurrent state continues during operation.
• Internal parts may possibly deteriorate or be damaged if the Power
Supply is used for applications with frequent inrush current or
overloading at the load end. Do not use the Power Supply for such
applications.
(See note 2.)
Charging the Battery
(See note 3.)
(See note 1.)
Note: 1. Convection of air
2. 50 mm min.
3. 10 mm min.
• This product is not intended to function as a battery charger. If a
battery is to be connected as the load, mount an overcurrent
limiting circuit and an overvoltage protection circuit.
6
ZEN-PA03024
Output Voltage Adjuster
Use the following guidelines to select the diode.
• The output voltage adjuster (V.ADJ) may possibly be damaged if it
is turned with unnecessary force. Do not turn the adjuster with
excessive force.
• After changing the setting of the adjuster, make sure that the output
capacity and output current do not exceed the rated output capacity
and rated output current.
• Output voltage is adjustable with the output voltage adjuster
(V.ADJ) on the front surface of the product from −10% to +15% of
the rated output voltage.
Do not increase the output voltage by more than 10% when
connected to a ZEN CPU Unit rated for 24 VDC.
Type
Twice the rated output
voltage or above
Forward current (IF)
Twice the rated output
voltage or above
Parallel Operation
Two Power Supplies can be operated in parallel.
Correct
DIN Track Mounting
Schottky Barrier diode
Dielectric strength (VRRM)
ZEN-PA03024
AC (L1)
+V
AC (L2/N)
To mount the Power Supply on a DIN track, hook portion (A) of the
Power Supply onto the track and press the Power Supply in direction
(B).
−V
AC (L1)
+V
AC (L2/N)
−V
(A)
ZEN-PA03024
(B)
To dismount the Power Supply, pull down portion (C) with a flat-blade
screwdriver and pull out the Power Supply.
Note: 1. For parallel operation, a maximum of two Power Supplies of
the same model can be connected.
2. For a DC input, parallel operation is possible only for 110 to
350 VDC.
3. To ensure that the voltage drop between each Power Supply
and the load is the same, use the same wire length and
thickness to connect the load.
4. The load current will become imbalanced if the output
voltages are different, possibly causing a serious reduction
in the life of one of the Power Supplies. Adjust the output
voltages of the Power Supplies to the same value.
In Case there is No Output Voltage
30 mm min.
(C)
Track stopper
Series Operation
The Power Supply is not designed for series operation.
The possible cause for no output voltage may be the presence of an
overload or overvoltage condition, or may be due to the functioning of
a latching protective device. The latching protection may operate if a
large amount of surge voltage such as a lightening surge occurs
while turning ON the Power Supply.
In case there is no output voltage, please check the following points
before contacting us:
Incorrect
ZEN-PA03024
AC (L1)
+V
AC (L2/N)
−V
AC (L1)
+V
AC (L2/N)
−V
• Check the overload protected status:
Check whether the load is in overload status or is short-circuited.
Remove wires to load when checking.
• Attempt to clear the latching protection function:
Turn the power supply OFF once, and leave it OFF for at least 1
minute. Then turn it on again to see if this clears the condition.
Insulation Resistance Test
ZEN-PA03024
When performing the test, be sure to short-circuit all the output
terminals to protect them from damage.
Output voltage (±)
Two Power Supplies can be used to create a ± output.
Correct
ZEN-PA03024
AC (L1)
+V
AC (L2/N)
−V
AC (L1)
+V
AC (L2/N)
−V
ZEN-PA03024
Note: When the load is an operational amplifier or other device
allowing series operation, a startup failure may occur when the
Power Supply is turned ON and internal circuits may be
damaged. Connect a diode as shown in the figure to prevent
this.
Dielectric Strength Test
• When a high voltage is applied between the input terminals and the
output terminals, electric energy builds up across the inductor L
and capacitor C of the internal noise filter. This energy may
generate a voltage surge when a high voltage is applied to the
Power Supply by a switch or timer, and as a result, the internal
parts of the Power Supply may possibly be damaged. To prevent
voltage impulses when testing, decrease the applied voltage using
the variable resistor on the dielectric strength testing equipment, or
apply the voltage so that it crosses the zero point when it rises or
falls.
• When performing the test, be sure to short-circuit all the output
terminals to protect them from damage.
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
In the interest of product improvement, specifications are subject to change without notice.
7
Read and Understand This Catalog
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or
comments.
Warranty and Limitations of Liability
WARRANTY
OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified)
from date of sale by OMRON.
OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR
FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS
DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER
WARRANTIES, EXPRESS OR IMPLIED.
LIMITATIONS OF LIABILITY
OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS
IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT
LIABILITY.
In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted.
IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS
OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT
SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR.
Application Considerations
SUITABILITY FOR USE
OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's
application or use of the products.
At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the
products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product,
machine, system, or other application or use.
The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible
uses of the products, nor is it intended to imply that the uses listed may be suitable for the products:
• Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog.
• Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles,
safety equipment, and installations subject to separate industry or government regulations.
• Systems, machines, and equipment that could present a risk to life or property.
Please know and observe all prohibitions of use applicable to the products.
NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE
SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND
INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.
PROGRAMMABLE PRODUCTS
OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof.
Disclaimers
CHANGE IN SPECIFICATIONS
Product specifications and accessories may be changed at any time based on improvements and other reasons.
It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made.
However, some specifications of the products may be changed without any notice. When in doubt, special model numbers may be assigned to fix or
establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual
specifications of purchased products.
DIMENSIONS AND WEIGHTS
Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown.
PERFORMANCE DATA
Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the
result of OMRON’s test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON
Warranty and Limitations of Liability.
ERRORS AND OMISSIONS
The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical,
typographical, or proofreading errors, or omissions.
2010.10
In the interest of product improvement, specifications are subject to change without notice.
OMRON Corporation
Industrial Automation Company
http://www.ia.omron.com/
(c)Copyright OMRON Corporation 2010 All Right Reserved.