New Product Switch Mode Power Supply S8JX (15/35/50/100/150/300/600-W Models) Wide Variety of Output Voltage Variations: 48 V for 15 to 150 W, and 5 or 12 V for 150 W • Easy Mounting: Mounting Bracket provided as a standard feature. (except for DIN Rail-mounting models) Mounts to DIN Rail. (except 600-W model) Screw-mount at the top. (except 300-/600-W models) • Safety standards: UL 508/60950-1 cUL CSA C22.2 No. 107.1 cUR CSA C22.2 No. 60950-1 EN 50178 (= VDE 0160) EN 60950-1 (= VDE 0805 Teil 1) • EMC: Conforms to EN 61204-3 Class A. EMI: EN55011 EMS: EN61000-4 • Input conditions: The input voltage range of 15-W, 35-W, 50-W, 100-W, and 150-W models has been increased to 80 to 370 VDC (EC Directives and safety standards do not apply.). ( ) Note: Refer to Safety Precautions on page 24. Model Number Structure Model Number Legend Note: 1. Not all combinations are possible. Refer to List of Models in Ordering Information on page 2. 2. Estimates can be provided for coatings and other specifications that are not given in the datasheet. Ask your OMRON representative for details. 15-/35-/50-/100-/150-W Models S8JX-G@@@@@@@ 1 1. Power Ratings 015: 15 W 035: 35 W 050: 50 W 100: 100 W 150: 150 W 2. Output Voltage 05: 5 V 12: 12 V 15: 15 V 24: 24 V 48: 48 V 2 3 4 3. Configuration (15/35/50/100/150 W model) None: Open-frame C: Covered 4. Configuration/mounting None: Front-mounting D: DIN Rail-mounting 300-/600-W Models S8JX-G@@@@@@ 1 1. Power Ratings 300: 300 W 600: 600 W 2 3 2. Output Voltage 24: 24 V 3. Configuration/mounting (covered type) C: Front-mounting CD: DIN Rail-mounting Note: Estimates can be provided for coatings and other specifications that are not given in the datasheet. Ask your OMRON representative for details. 1 S8JX Ordering Information List of Models Note: For details on normal stock models, contact your nearest OMRON representative. Configuration Input voltage Power ratings 15 W 35 W Front-mounting *1 50 W 100 W 100 to 240 VAC (free) (80 to 370 VDC *3) S8JX-G15005@: Switchable between 100 to 120 VAC and 200 to 240 VAC. (DC power cannot be input.) Open-frame Power Supplies 150 W 15 W 35 W DIN Rail-mounting *2 50 W 100 W 150 W Output voltage (VDC) 5V 12 V 15 V 24 V 48 V 5V 12 V 15 V 24 V 48 V 5V 12 V 24 V 48 V 5V 12 V 24 V 48 V 5V 12 V 24 V 48 V 5V 12 V 15 V 24 V 48 V 5V 12 V 15 V 24 V 48 V 5V 12 V 24 V 48 V 5V 12 V 24 V 48 V 5V 12 V 24 V 48 V Output current 3A 1.3 A 1A 0.65 A 0.35 A 7A 3A 2.4 A 1.5 A 0.75 A 10 A 4.2 A 2.1 A 1.1 A 20 A 8.5 A 4.5 A 2.1 A 30 A 13 A 6.5 A 3.3 A 3A 1.3 A 1A 0.65 A 0.35 A 7A 3A 2.4 A 1.5 A 0.75 A 10 A 4.2 A 2.1 A 1.1 A 20 A 8.5 A 4.5 A 2.1 A 30 A 13 A 6.5 A 3.3 A *1. The front-mounting bracket is included as standard with the product. *2. A front-mounting bracket is not included with the product. *3. The range for compliance with EC Directives and safety standards (UL, EN, etc.) is 100 to 240 VAC (85 to 264 VAC). 2 Model S8JX-G01505 S8JX-G01512 S8JX-G01515 S8JX-G01524 S8JX-G01548 S8JX-G03505 S8JX-G03512 S8JX-G03515 S8JX-G03524 S8JX-G03548 S8JX-G05005 S8JX-G05012 S8JX-G05024 S8JX-G05048 S8JX-G10005 S8JX-G10012 S8JX-G10024 S8JX-G10048 S8JX-G15005 S8JX-G15012 S8JX-G15024 S8JX-G15048 S8JX-G01505D S8JX-G01512D S8JX-G01515D S8JX-G01524D S8JX-G01548D S8JX-G03505D S8JX-G03512D S8JX-G03515D S8JX-G03524D S8JX-G03548D S8JX-G05005D S8JX-G05012D S8JX-G05024D S8JX-G05048D S8JX-G10005D S8JX-G10012D S8JX-G10024D S8JX-G10048D S8JX-G15005D S8JX-G15012D S8JX-G15024D S8JX-G15048D S8JX Configuration Input voltage Power ratings 15 W 35 W Front-mounting *1 50 W 100 W 100 to 240 VAC (free) (80 to 370 VDC *3) S8JX-G15005@@: Switchable between 100 to 120 VAC and 200 to 240 VAC. (DC power cannot be input.) Covered Power Supplies 150 W 15 W 35 W DIN Rail-mounting *2 50 W 100 W 150 W Front-mounting *1 DIN Rail-mounting *2 100 to 120 VAC 200 to 240 VAC (Swichable) 300 W 600 W 300 W Output voltage (VDC) 5V 12 V 15 V 24 V 48 V 5V 12 V 15 V 24 V 48 V 5V 12 V 24 V 48 V 5V 12 V 24 V 48 V 5V 12 V 24 V 48 V 5V 12 V 15 V 24 V 48 V 5V 12 V 15 V 24 V 48 V 5V 12 V 24 V 48 V 5V 12 V 24 V 48 V 5V 12 V 24 V 48 V 24 V Output current 3A 1.3 A 1A 0.65 A 0.35 A 7A 3A 2.4 A 1.5 A 0.75 A 10 A 4.2 A 2.1 A 1.1 A 20 A 8.5 A 4.5 A 2.1 A 30 A 13 A 6.5 A 3.3 A 3A 1.3 A 1A 0.65 A 0.35 A 7A 3A 2.4 A 1.5 A 0.75 A 10 A 4.2 A 2.1 A 1.1 A 20 A 8.5 A 4.5 A 2.1 A 30 A 13 A 6.5 A 3.3 A 14 A 27 A 14 A *1. The front-mounting bracket is included as standard with the product. *2. A front-mounting bracket is not included with the product. *3. The range for compliance with EC Directives and safety standards (UL, EN, etc.) is 100 to 240 VAC (85 to 264 VAC). 3 Model S8JX-G01505C S8JX-G01512C S8JX-G01515C S8JX-G01524C S8JX-G01548C S8JX-G03505C S8JX-G03512C S8JX-G03515C S8JX-G03524C S8JX-G03548C S8JX-G05005C S8JX-G05012C S8JX-G05024C S8JX-G05048C S8JX-G10005C S8JX-G10012C S8JX-G10024C S8JX-G10048C S8JX-G15005C S8JX-G15012C S8JX-G15024C S8JX-G15048C S8JX-G01505CD S8JX-G01512CD S8JX-G01515CD S8JX-G01524CD S8JX-G01548CD S8JX-G03505CD S8JX-G03512CD S8JX-G03515CD S8JX-G03524CD S8JX-G03548CD S8JX-G05005CD S8JX-G05012CD S8JX-G05024CD S8JX-G05048CD S8JX-G10005CD S8JX-G10012CD S8JX-G10024CD S8JX-G10048CD S8JX-G15005CD S8JX-G15012CD S8JX-G15024CD S8JX-G15048CD S8JX-G30024C S8JX-G60024C S8JX-G30024CD S8JX Ratings, Characteristics, and Functions Input specification 100 to 240 V input Power ratings *1 Item Efficiency 15 W 35 W 68% min. 73% min. 100 to 240 VAC (allowable range: 85 to 264 VAC) Voltage *2 80 to 370 VDC *9 Note: This range is not applicable for the safety standards. Frequency *2 Current *3 Input 50/60 Hz (47 to 450 Hz) 100 V input 0.4 A max. 200 V input 0.25 A max. Power factor Inrush current (for a cold start at 25°C) *3 Output *4 0.6 A max. --- Harmonic current emissions Leakage current *3 1 A max. --- 100 V input 0.5 mA max. 200 V input 1 mA max. 100 V input 20 A max. 200 V input 40 A max. Noise filter Yes Voltage adjustment range *5 −10% to 15% (with V. ADJ) (48-V models: ±10%) Ripple *3 2% (p-p) max. Input variation influence 0.4% max. with AC input voltage Load variation influence 0.8% max. (0 to 100% load, rated input voltage) Temperature variation influence 0.05%/°C max. (at rated input and output) Startup time 500 ms max. (up to 90% of output voltage at rated input and output) Hold time *3 20 ms min. Overload protection *6 105% to 175% of rated load current, voltage drop, intermittent, automatic reset Overvoltage protection *7 Yes Additional Overheat protection functions Parallel operation No No Series operation Yes (For up to two Power Supplies; external diodes required.) Protective circuit operation indicator No Ambient operating temperature Refer to the derating curve in Engineering Data on page 13 (with no icing or condensation). Storage temperature −25 to 65°C (with no icing or condensation) Ambient operating humidity 25% to 85% (Storage humidity: 25% to 90%) Dielectric strength 3.0 kVAC for 1 min. (between all inputs and outputs; detection current: 20 mA) 2.0 kVAC for 1 min. (between all inputs and PE terminals; detection current: 20 mA) 1.0 kVAC for 1 min. (between all outputs and PE terminals; detection current: 20 mA) Insulation resistance 100 MΩ min. (between all outputs and all inputs/PE terminals) at 500 VDC Vibration resistance 10 to 55 Hz, 0.375-mm single amplitude for 2 h each in X, Y, and Z directions Shock resistance 150 m/s2, 3 times each in ±X, ±Y, ±Z directions Output indicator EMI Other EMS Yes (Color: Green) Conducted Emissions Conforms to EN 55011 Group 1 Class A and based on FCC Class A Radiated Emissions Conforms to EN 55011 Group 1 Class A Electrostatic Discharge Confirms to EN61000-4-2 Radiated Electromagnetic Field Confirms to EN61000-4-3 Electrical Fast Transient/Burst Confirms to EN61000-4-4 Surge Confirms to EN61000-4-5 Conducted Disturbance Confirms to EN61000-4-6 Voltage Dips/Short Interruptions Confirms to EN61000-4-11 UL Listed: UL 508 (Listing), UL UR: UL 60950-1 (Recognition) Approved standards *9 cUL Listed: CSA C22.2 No.107.1 cUR: CSA C22.2 No. 60950-1 EN/VDE: EN50178 (= VDE 0160), EN 60950-1 (= VDE 0805 Teil 1) (Terminal block: Based on DIN 50274 (VDE 0660-514)) SEMI SEMI F47-0200 (200-VAC input) Weight *8 250 g max. *1. When a load is connected that has a built-in DC-DC converter, the overload protection may operate at startup and the Power Supply may not start. Refer to Overload Protection on page 15. *2. Do not use an Inverter output for the Power Supply. Inverters with an output frequency of 50/60 Hz are available, but the rise in the internal temperature of the Power Supply may result in ignition or burning. *3. Rated input voltage: 100 or 200 VAC at 100% load. *4. Output characteristics: Specified at power supply output terminals. *5. If the output voltage adjuster (V. ADJ) is turned, the voltage will increase by more than the allowable voltage range. When adjusting the output voltage, confirm the actual output voltage from the Power Supply and be sure that load is not damaged. *6. For details, refer to Overload Protection on page 15. *7. To reset the protection, turn OFF the input power for seven minutes or longer and then turn it back ON. *8. The weight indicated is a for Front-mounting, Open-frame Power Supply. *9. The range for compliance with EC Directives and safety standards (UL, EN, etc.) is 100 to 240 VAC (85 to 264 VAC). 4 S8JX Input specification 100 to 240 V input Power ratings *1 Item Efficiency 50 W 100 W 76% min. 100 to 240 VAC (allowable range: 85 to 264 VAC) Voltage *2 80 to 370 VDC *9 Note: This range is not applicable for the safety standards. Frequency *2 Current *3 Input 50/60 Hz (47 to 450 Hz) 100 V input 1.4 A max. 200 V input 0.8 A max. Power factor Inrush current (for a cold start at 25°C) *3 Output *4 1.5 A max. --- Harmonic current emissions Leakage current *3 2.5 A max. --- 100 V input 0.5 mA max. 200 V input 1 mA max. 100 V input 20 A max. 200 V input 40 A max. Noise filter Yes Voltage adjustment range *5 −10% to 15% (with V. ADJ) (48-V models: ±10%) Ripple *3 2% (p-p) max. Input variation influence 0.4% max. (with AC input voltage) Load variation influence 0.8% max. (0 to 100% load, rated input voltage) Temperature variation influence 0.05%/°C max. (at rated input and output) Startup time 500 ms max. (up to 90% of output voltage at rated input and output) Hold time *3 20 ms min. Overload protection *6 105% to 175% of rated load current, voltage drop, intermittent, automatic reset Overvoltage protection *7 Yes Additional Overheat protection functions Parallel operation No No Series operation Yes (For up to two Power Supplies; external diodes required.) Protective circuit operation indicator No Ambient operating temperature Refer to the derating curve in Engineering Data on page 13 (with no icing or condensation). Storage temperature −25 to 65°C (with no icing or condensation) Ambient operating humidity 25% to 85% (Storage humidity: 25% to 90%) Dielectric strength 3.0 kVAC for 1 min. (between all inputs and outputs; detection current: 20 mA) 2.0 kVAC for 1 min. (between all inputs and PE terminals; detection current: 20 mA) 1.0 kVAC for 1 min. (between all outputs and PE terminals; detection current: 20 mA) Insulation resistance 100 MΩ min. (between all outputs and all inputs/PE terminals) at 500 VDC Vibration resistance 10 to 55 Hz, 0.375-mm single amplitude for 2 h each in X, Y, and Z directions Shock resistance 150 m/s2, 3 times each in ±X, ±Y, ±Z directions Output indicator EMI Other EMS Yes (Color: Green) Conducted Emissions Conforms to EN 55011 Group 1 Class A and based on FCC Class A Radiated Emissions Conforms to EN 55011 Group 1 Class A Electrostatic Discharge Confirms to EN61000-4-2 Radiated Electromagnetic Field Confirms to EN61000-4-3 Electrical Fast Transient/Burst Confirms to EN61000-4-4 Surge Confirms to EN61000-4-5 Conducted Disturbance Confirms to EN61000-4-6 Voltage Dips/Short Interruptions Confirms to EN61000-4-11 UL Listed: UL 508 (Listing), UL UR: UL 60950-1 (Recognition) Approved standards *9 cUL Listed: CSA C22.2 No.107.1 cUR: CSA C22.2 No. 60950-1 EN/VDE: EN50178 (= VDE 0160), EN 60950-1 (= VDE 0805 Teil 1) (Terminal block: Based on DIN 50274 (VDE 0660-514)) SEMI SEMI F47-0200 (200-VAC input) Weight *8 300 g max. 550 g max. *1. When a load is connected that has a built-in DC-DC converter, the overload protection may operate at startup and the Power Supply may not start. Refer to Overload Protection on page 15. *2. Do not use an Inverter output for the Power Supply. Inverters with an output frequency of 50/60 Hz are available, but the rise in the internal temperature of the Power Supply may result in ignition or burning. *3. Rated input voltage: 100 or 200 VAC at 100% load. *4. Output characteristics: Specified at power supply output terminals. *5. If the output voltage adjuster (V. ADJ) is turned, the voltage will increase by more than the allowable voltage range. When adjusting the output voltage, confirm the actual output voltage from the Power Supply and be sure that load is not damaged. *6. For details, refer to Overload Protection on page 15. *7. To reset the protection, turn OFF the input power for seven minutes or longer and then turn it back ON. *8. The weight indicated is a for Front-mounting, Open-frame Power Supply. *9. The range for compliance with EC Directives and safety standards (UL, EN, etc.) is 100 to 240 VAC (85 to 264 VAC). 5 S8JX Input specification Efficiency Voltage *2 Frequency *2 Current *3 Input Inrush current (for a cold start at 25°C) *3 78% min. 79% min. Switchable between 100 to 120 VAC (allowable range: 85 to 132 VAC) and 200 to 240 VAC (allowable range: 170 to 264 VAC). 100 to 240 VAC (allowable range: 85 to 264 VAC) 85% min. 80 to 370 VDC *9 50/60 Hz (47 to 450 Hz) 3.5 A max. 3.6 A max. 3.5 A max. 200 V input 2.1 A max. 2.2 A max. 2.1 A max. Power factor Leakage current *3 100 to 240 V input 150 W at 12 V 150 W at 24 or 48 V 150 W at 5 V 100 V input --- Harmonic current emissions Output *4 100/200 V switchable Power ratings *1 Item --- 100 V input 0.5 mA max. 200 V input 1 mA max. 100 V input 20 A max. 200 V input 40 A max. Noise filter Yes Voltage adjustment range *5 −10% to 15% (with V. ADJ) (48-V models: ±10%) Ripple *3 2% (p-p) max. Input variation influence 0.4% max. (with AC input voltage) Load variation influence 0.8% max. (0 to 100% load, rated input voltage) Temperature variation influence 0.05%/°C max. (at rated input and output) Startup time 500 ms max. (up to 90% of output voltage at rated input and output) Hold time *3 20 ms min. Overload protection *6 105% to 175% of rated load current, voltage drop, automatic reset Overvoltage protection *7 Additional functions Overheat protection Parallel operation 105% to 175% of rated load current, voltage drop, intermittent, automatic reset Yes No No Series operation Yes (For up to two Power Supplies; external diodes required.) Protective circuit operation indicator No Ambient operating temperature Refer to the derating curve in Engineering Data on page 13 (with no icing or condensation). Storage temperature −25 to 65°C (with no icing or condensation) Ambient operating humidity 25% to 85% (Storage humidity: 25% to 90%) Dielectric strength 3.0 kVAC for 1 min. (between all inputs and outputs; detection current: 20 mA) 2.0 kVAC for 1 min. (between all inputs and PE terminals; detection current: 20 mA) 1.0 kVAC for 1 min. (between all outputs and PE terminals; detection current: 20 mA) Insulation resistance 100 MΩ min. (between all outputs and all inputs/PE terminals) at 500 VDC Vibration resistance 10 to 55 Hz, 0.375-mm single amplitude for 2 h each in X, Y, and Z directions Shock resistance 150 m/s2, 3 times each in ±X, ±Y, ±Z directions Output indicator EMI Other EMS Yes (Color: Green) Conducted Emissions Conforms to EN 55011 Group 1 Class A and based on FCC Class A Radiated Emissions Conforms to EN 55011 Group 1 Class A Electrostatic Discharge Confirms to EN61000-4-2 Radiated Electromagnetic Field Confirms to EN61000-4-3 Electrical Fast Transient/Burst Confirms to EN61000-4-4 Surge Confirms to EN61000-4-5 Conducted Disturbance Confirms to EN61000-4-6 Voltage Dips/Short Interruptions Confirms to EN61000-4-11 UL Listed: UL 508 (Listing), UL UR: UL 60950-1 (Recognition) Approved standards *9 cUL Listed: CSA C22.2 No.107.1 cUR: CSA C22.2 No. 60950-1 EN/VDE: EN50178 (= VDE 0160), EN 60950-1 (= VDE 0805 Teil 1) (Terminal block: Based on DIN 50274 (VDE 0660-514)) SEMI --- Weight *8 800 g max. SEMI F47-0200 (200-VAC input) 700 g max. 600 g max. *1. When a load is connected that has a built-in DC-DC converter, the overload protection may operate at startup and the Power Supply may not start. Refer to Overload Protection on page 15. *2. Do not use an Inverter output for the Power Supply. Inverters with an output frequency of 50/60 Hz are available, but the rise in the internal temperature of the Power Supply may result in ignition or burning. *3. Rated input voltage: 100 or 200 VAC at 100% load. *4. Output characteristics: Specified at power supply output terminals. *5. If the output voltage adjuster (V. ADJ) is turned, the voltage will increase by more than the allowable voltage range. When adjusting the output voltage, confirm the actual output voltage from the Power Supply and be sure that load is not damaged. *6. For details, refer to Overload Protection on page 15. *7. To reset the protection, turn OFF the input power for seven minutes or longer and then turn it back ON. *8. The weight indicated is a for Front-mounting, Open-frame Power Supply. *9. The range for compliance with EC Directives and safety standards (UL, EN, etc.) is 100 to 240 VAC (85 to 264 VAC). 6 S8JX Input specification Efficiency 300 W Current *3 50/60 Hz (47 to 450 Hz) 100 V input 8 A max. 200 V input 4.5 A max. Power factor Inrush current (for a cold start at 25°C) *3 14 A max. 8 A max. --- Harmonic current emissions Leakage current *3 80% min. 100 to 120 VAC (allowable range: 85 to 132 VAC) 200 to 240 VAC (allowable range: 170 to 264 VAC) (Switchable) Frequency *2 --- 100 V input 0.5 mA max. 200 V input 1 mA max. 100 V input 25 A max. 30 A max. 200 V input 50 A max. 60 A max. Noise filter Output *4 600 W 82% min. Voltage *2 Input 100/200 V (Selected) Power ratings *1 Item Yes Voltage adjustment range *5 −10% to 15% (with V. ADJ) Ripple *3 2% (p-p) max. Input variation influence 0.4% max. Load variation influence 0.8% max. (0 to 100% load, rated input voltage) Temperature variation influence 0.05%/°C max. Startup time 650 ms max. Hold time *3 20 ms min. Overload protection *6 105% to 175% of rated load current, voltage drop, intermittent, automatic reset Overvoltage protection *7 Additional functions Overheat protection Parallel operation Series operation 500 ms max. 105% to 175% of rated load current, Inverted L voltage drop, the circuit will be shut OFF when the overload exceeds 5 s. *9 Yes Yes *9 No Yes *9 Yes (up to 5 units) Yes (For up to two Power Supplies; external diodes required.) Protective circuit operation indicator No Ambient operating temperature Refer to the derating curve in Engineering Data on page 13 (with no icing or condensation). Storage temperature −25 to 65°C (with no icing or condensation) Ambient operating humidity 25% to 85% (Storage humidity: 25% to 90%) Dielectric strength 3.0 kVAC for 1 min. (between all inputs and outputs; detection current: 25 mA) 2.0 kVAC for 1 min. (between all inputs and PE terminals; detection current: 25 mA) 1.0 kVAC for 1 min. (between all outputs and PE terminals; detection current: 25 mA) Insulation resistance 100 MΩ min. (between all outputs and all inputs/PE terminals) at 500 VDC Vibration resistance 10 to 55 Hz, 0.375-mm single amplitude for 2 h each in X, Y, and Z directions Shock resistance 150 m/s2, 3 times each in ±X, ±Y, ±Z directions Output indicator EMI Other EMS Yes (color: red) Yes (Color: Green) Conducted Emissions *3 Conforms to EN 55011 Group 1 Class A and based on FCC Class A Radiated Emissions Conforms to EN 55011 Group 1 Class A Electrostatic Discharge Confirms to EN61000-4-2 Radiated Electromagnetic Field Confirms to EN61000-4-3 Electrical Fast Transient/Burst Confirms to EN61000-4-4 Surge Confirms to EN61000-4-5 Conducted Disturbance Confirms to EN61000-4-6 Voltage Dips/Short Interruptions Confirms to EN61000-4-11 UL UR: UL 508 (Recognition), UL UR: UL 60950-1 (Recognition) Approved standards *10 cUL Listed: CSA C22.2 No.107.1 cUR: CSA C22.2 No. 60950-1 EN/VDE: EN50178 (= VDE 0160), EN 60950-1 (= VDE 0805 Teil 1) (Terminal block: Based on DIN 50274 (VDE 0660-514)) SEMI SEMI F47-0200 (200-VAC input) Weight *8 1,600 g max. 2,500 g max. *1. When a load is connected that has a built-in DC-DC converter, the overload protection may operate at startup and the Power Supply may not start. Refer to Overload Protection on page 15. *2. Do not use an Inverter output for the Power Supply. Inverters with an output frequency of 50/60 Hz are available, but the rise in the internal temperature of the Power Supply may result in ignition or burning. *3. Rated input voltage: 100 or 200 VAC at 100% load. *4. Output characteristics: Specified at power supply output terminals. *5. If the output voltage adjuster (V. ADJ) is turned, the voltage will increase by more than the allowable voltage range. When adjusting the output voltage, confirm the actual output voltage from the Power Supply and be sure that load is not damaged. *6. For details, refer to Overload Protection on page 15. *7. To reset the protection, turn OFF the input power for three minutes or longer and then turn it back ON. *8. The weight indicated is a for Front-mounting, Open-frame Power Supply. *9. The protection-ON alarm indicator will light as soon as the output is interrupted. For resetting, turn OFF the input power, leave for more than three minutes , and then turn it back ON again. *10.The range for compliance with EC Directives and safety standards (UL, EN, etc.) is 100 to 240 VAC (85 to 264 VAC). 7 S8JX Connections Block Diagrams S8JX-G01505@@ (15 W) S8JX-G01512@@ (15 W) S8JX-G01515@@ (15 W) S8JX-G01524@@ (15 W) AC (L) INPUT +V Fuse 2.0 A Noise filter DC OUTPUT −V AC (N) Inrush current protection Rectifier Smoothing circuit Rectifier/ Smoothing circuit Drive control Circuit Overcurrent detection circuit Voltage detection Overvoltage detection circuit Photocoupler S8JX-G01548@@ (15 W) +V AC (L) INPUT Fuse: 2.0 A Noise filter DC OUTPUT −V AC (N) Inrush current protection Rectifier Smoothing circuit Rectifier/ smoothing circuit Drive control circuit Overcurrent detection circuit Voltage detection circuit Overvoltage detection circuit Photocoupler S8JX-G03505@@ (35 W) S8JX-G03512@@ (35 W) S8JX-G03515@@ (35 W) S8JX-G03524@@ (35 W) AC (L) INPUT +V Fuse 3.15 A Noise filter DC OUTPUT −V AC (N) Inrush current protection Rectifier Smoothing circuit Rectifier/ Smoothing circuit Drive control Circuit Overcurrent detection circuit Voltage detection Overvoltage detection circuit Photocoupler S8JX-G03548@@ (35 W) +V AC (L) INPUT Fuse: 3.15 A Noise filter DC OUTPUT −V AC (N) Rectifier Inrush current protection Smoothing circuit Rectifier/ smoothing circuit Drive control circuit Overcurrent detection circuit Voltage detection circuit Overvoltage detection circuit Photocoupler 8 S8JX S8JX-G05005@@ (50 W) S8JX-G05012@@ (50 W) S8JX-G05024@@ (50 W) AC (L) INPUT +V Fuse 6.3 A Noise filter DC OUTPUT −V AC (N) Inrush current protection Rectifier Smoothing circuit Rectifier/ Smoothing circuit Drive control Circuit Overcurrent detection circuit Voltage detection Overvoltage detection circuit Photocoupler S8JX-G05048@@ (50 W) +V AC (L INPUT Fuse: 6.3 A Noise filter DC OUTPUT −V AC (N) Inrush current protection Rectifier Smoothing circuit Rectifier/ smoothing circuit Drive control circuit Overcurrent detection circuit Voltage detection circuit Overvoltage detection circuit Photocoupler S8JX-G100@@@@ (100 W) AC (L) INPUT +V Fuse 8A Noise filter DC OUTPUT −V AC (N) Inrush current protection Rectifier Smoothing circuit Rectifier/ Smoothing circuit Drive control Circuit Overcurrent detection circuit Voltage detection Overvoltage detection circuit Photocoupler 9 S8JX S8JX-G15005@@ (150 W) Rectifier/ smoothing circuit 㧗V AC (L) INPUT Fuse: 8A Noise filter DC OUTPUT 㧙V AC (N) Rectifier/ smoothing circuit Inrush current protection Drive control circuit Overcurrent detection circuit Voltage detection circuit Overvoltage detection circuit Photocoupler Input voltage switch 100/200 V switching Note: Set the input voltage switch to "115V" for 100 to 120 VAC and to "230V" for 200 to 240 VAC. S8JX-G15012@@ (150 W) S8JX-G15024@@ (150 W) S8JX-G15048@@ (150 W) +V AC (L) INPUT Fuse 10 A Noise filter DC OUTPUT −V AC (N) Inrush current protection Rectifier Smoothing circuit Rectifier/ Smoothing circuit Drive control Circuit Overcurrent detection circuit Voltage detection Overvoltage detection circuit Photocoupler 10 S8JX S8JX-G30024@@ (300 W) Rectifier/ Smoothing circuit +V AC (L) Fuse 10 A INPUT Noise filter DC OUTPUT −V AC (N) Inrush current protection Rectifier/ Smoothing circuit 100/200V (Selectable) Drive control Circuit Overcurrent detection circuit Voltage detection Overvoltage detection circuit Photocoupler Parallel operation selector Note: Short-circuit the input voltage selector terminals if the input is 100 to 120 VAC. Keep the terminals open if the input is 200 to 240 VAC. S8JX-G60024@@ (600 W) Rectifier/ Smoothing circuit +V AC (L) Fuse 10 A INPUT Noise filter DC OUTPUT −V AC (N) Inrush current protection Rectifier/ Smoothing circuit Fan 100/200V (Selectable) Drive control Circuit Overcurrent detection circuit Voltage detection Overheat detection circuit Overvoltage detection circuit Photocoupler Parallel operation selector Note: Short-circuit the input voltage selector terminals if the input is 100 to 120 VAC. Keep the terminals open if the input is 200 to 240 VAC. 11 S8JX Construction and Nomenclature Nomenclature 15-/35-/50-/100-/150-W Models No. D E D E A +V −V −V C C AC (L) B B AC (N) 2 AC Input Terminals (L), (N) Connect the input lines to these terminals. *1 3 Protective Earth Terminal (PE) ( Connect the ground line to these terminals. *2 4 Output Voltage Adjuster (V. ADJ) Use to adjust the voltage. 5 Output Indicator (DC ON: Green) Lights green while a direct current (DC) output is ON. 6 Input voltage switch Switches the internal circuits according to the input voltage. "115V": 100 to 120 VAC "230V": 200 to 240 VAC AC (L) AC (N) Function 1 +V A Name DC Output Connect the load lines to these terminals. Terminals (−V), (+V) F ) Bottom 100 to 120 VAC Note: The S8JX-G05024CD is shown above. 200 to 240 VAC *1. The fuse is located on the (L) side. It is NOT user-replaceable. For a DC power input, connect the low side to the positive (+) terminal. Note: The S8JX-G15005C is shown *2. This is the protective earth terminal specified in the safety standards. above. Always ground this terminal. 300-W Model 600-W Model A E F A AC (L) +V AC (N) +V FE G −V −V +V +V B Side D −V −V C H Bottom H AC (L) AC (N) D No. 1 Name 2 AC Input Terminals (L), (N) Protective Earth Terminal (PE) ( C Function DC Output Terminals (+V), (−V) 3 B Connect the load lines to these terminals. Connect the input lines to these terminals. *1 ) Connect the ground line to these terminals. *2 4 Input Voltage Selector Terminals Short-circuit the terminals if the input is 100 to 120 VAC and open the terminals if the input is 200 to 230 VAC. 5 Output Indicator (DC ON: Green) Lights while a Direct Current (DC) output is ON. 6 Output Voltage Adjuster (V. ADJ) It is possible to increase or decrease the output voltage. 7 Protection-ON Alarm Indicator (DC ON: Red) The red indicator will be lit if the overvoltage (for a 600-W model) or overheat protection (for a 600-W model) circuit is triggered. This indicator will also be lit when overload (for a 600-W model) is detected. 8 Selector of Parallel Operation Set the selector to PARALLEL if the Units are in parallel operation. *1. The fuse is located on the (L) side. It is NOT user-replaceable. *2. This is the protective earth terminal specified in the safety standards. Always ground this terminal. Reference Values Reliability (MTBF) 12 S8JX-G15012@@ and S8JX-G15005@@ Other models 240,000 hrs 250,000 hrs Definition MTBF stands for Mean Time Between Failures, which is calculated according to the probability of accidental device failures, and indicates reliability of devices. Therefore, it does not necessarily represent a life of the product. Life expectancy 10 yrs. min. Definition The life expectancy indicates average operating hours under the ambient temperature of 40°C and a load rate of 50%. Normally this is determined by the life expectancy of the built-in aluminum electrolytic capacitor. S8JX Engineering Data Derating Curves (Standard Mounting) 15-/35-/50-/100-/150-W Models Covered Power Supplies 120 100 A Load rate (%) Load rate (%) Open-frame Power Supplies 120 100 80 80 60 60 40 40 20 20 0 −20 −10 0 10 20 0 −20 −10 30 40 50 60 70 80 Ambient Temperature (°C) A 0 10 20 30 40 50 60 70 80 Ambient Temperature (°C) Note: 1. Internal parts may occasionally deteriorate or be damaged. Do not use the Power Supply in areas outside the derating curve (i.e., the area shown by shading A in the above graph). 2. If there is a derating problem, use forced air-cooling. 3. For Customers Using a DC Input When using an input voltage of less than 100 VDC, reduce the load calculated with the above derating curve by at least the following coefficients. 35-W and 100-W (5-V or 12-V output) models: 0.8 50-W/150-W models: 0.85 (DC power cannot be input only to the S8JX-G15005@@.) 15-W and 100-W (24-V or 48-V output): 0.9 300-/600-W Models Parallel Operation 120 100 A Load rate (%) Load rate (%) Single Unit Operation 120 100 80 80 60 60 40 40 20 20 A Solid line 0 −20 −10 0 10 20 30 40 50 60 70 80 Ambient Temperature (°C) 0 −20 −10 Dotted line 0 10 20 Front-mounting, Bottom-mounting, DIN Rail mounting, Side mounting (600W) Side mounting (300W) 30 40 50 60 70 80 Ambient Temperature (°C) Note: 1. Internal parts may occasionally deteriorate or be damaged. Do not use the Power Supply in areas outside the derating curve (i.e., the area shown by shading A in the above graph). 2. If there is a derating problem, use forced air-cooling. 13 S8JX Mounting 15-/35-/50-/100-/150-W Models The following three mounting methods are possible. A. Front-mounting: Refer to Mounting Bracket Provided with Front-mounting Power Supplies a on page 20. B. Bottom-mounting C. Side-mounting Note: Additional mounting methods are also available using DIN Rail-mounting models. B C Standard Mounting 15-/35-/50-/100-/150-W Models Front-mounting Bottom-mounting DIN Rail-mounting Vertical Side-mounting Horizontal Side-mounting * * * * Note: 1. Improper mounting will interfere with heat dissipation and may occasionally result in deterioration or damage of internal parts. Use the standard mounting method only. 2. When mounting the Power Supply, mounting it to a metal plate (*) is recommended. 3. Install the Power Supply so that the air flow circulates around the Power Supply, as the Power Supply is designed to radiate heat by means of natural air flow. 300-W Model Bottom-mounting Front-mounting 20mm min. 20mm min. Side-mounting 20mm min. 20mm min. DIN Rail mounting Note: 1. Improper mounting will interfere with heat dissipation and may occasionally result in deterioration or damage of internal parts. Use the standard mounting method only. 2. When mounting the Power Supply, mounting it to a metal plate (*) is recommended. 3. Install the Power Supply so that the air flow circulates around the Power Supply, as the Power Supply is designed to radiate heat by means of natural air flow. 600-W Model Front-mounting Bottom-mounting 20mm min. Side-mounting 14 20mm min. 20mm min. 20mm min. Note: 1. Improper mounting will interfere with heat dissipation and may occasionally result in deterioration or damage of internal parts. Use the standard mounting method only. 2. When mounting the Power Supply, mounting it to a metal plate (*) is recommended. 3. Install the Power Supply so that the air flow circulates around the Power Supply, as the Power Supply is designed to radiate heat by means of natural air flow. S8JX Overload Protection The Power Supply is provided with an overload protection function that protects the power supply from possible damage by overcurrent. When the output current rises above 105% to 175% min. of the rated current, the protection function is triggered, decreasing the output voltage. When the output current falls within the rated range, the overload protection function is automatically cleared. (Reference value) 600-W Model Output voltage (V) Output voltage (V) 15-/35-/50-/100-/150-W (12-/24-/48-V) Models Intermittent operation Output interrupted 0 50 100 Load rate (%) Output voltage [V] 150-W, 5-V Models 0 50 100 Load rate (%) Output voltage (V) 300-W Model Intermittent operation 0 15 50 100 Load rate (%) 0 50 100 Load rate (%) If an excessive current flows for 5 s or more, the output will be turned OFF and simultaneously the protection-ON alarm indicator will be lit. To reset the S8JX, turn OFF the power, leave the S8JX for at least three minutes, and then turn it ON again. Note: 1. When a load is connected that has a built-in DC-DC converter, the overload protection may operate at startup and the power supply may not start. 2. Internal parts may occasionally deteriorate or be damaged if a short-circuited or overcurrent state continues during operation. 3. Internal parts may possibly deteriorate or be damaged if the Power Supply is used for applications with frequent inrush current or overloading at the load end. Do not use the Power Supply for such applications. S8JX Overvoltage Protection 15-/35-/50-/100-/150-W Models Consider the possibility of an overvoltage and design the system so that the load will not be subjected to an excessive voltage even if the feedback circuit in the power supply fails. When an excessive voltage that is approximately 130% of the rated voltage or more is output, the output voltage is shut OFF, preventing damage to the load due to overvoltage. Reset the input power by turning it OFF for at least seven minutes and then turning it back ON again. 300-/600-W Models Consider the possibility of an overvoltage and design the system so that the load will not be subjected to an excessive voltage even if the feedback circuit in the Power Supply fails. When an excessive voltage that is approximately 120% of the rated voltage or more is output, the output voltage is shut OFF, preventing damage to the load due to overvoltage. Reset the input power by turning it OFF for at least three minute and then turning it back ON again. Output voltage (V) (Reference value) Overvoltage protection Operating Rated output Voltage Variable range 0V Note: Do not turn ON the power again until the cause of the overvoltage has been removed. Overheat Protection 600-W Model If the internal temperature rises excessively as a result of fan failure or any other reason, the overheat protection circuit will be triggered to shut OFF the output voltage and simultaneously the protection-ON alarm indicator will be lit. Reset the input power by turning it OFF for at least three minutes and then turning it back ON again. Inrush Current, Startup Time, Output Hold Time Input ON Input OFF AC input voltage Inrush current on input application AC input current 96.5% 90% Output voltage Startup time Hold time (20 ms min.) Note: A maximum startup time of 500 ms is required (650 ms for 300 W). Construct a system configuration that considers the startup time of other devices. 16 S8JX Dimensions (Unit: mm) Front-mounting Models S8JX-G015@@ (15 W) S8JX-G015@@C (15 W) S8JX-G035@@ (35 W) S8JX-G035@@C (35 W) Panel mounting holes dimensions 5 max. 90±1 10 max. Surface screw mounting Label 9.5 Two, M3 3.5 8.2 Side Mounting 91±1 75±0.5 75±0.5 82±0.5 Five, M3.5 3.5 dia. Two, M3 Cover 35.5±1 39.5±1 4.5 82±0.5 8.5 78±0.5 Bottom Mounting 7.5 78±0.5 3.5 3.5 dia. 26.5 17.5 Two, M3 (Depth 4 mm max.) 50±0.5 15 S8JX-G050@@ (50 W) S8JX-G050@@C (50 W) 5 max. 100±1 10 max. Panel mounting holes dimensions Label 9.5 Surface screw mounting Two, M3 3.5 8.2 Side Mounting 75±0.5 92±1 92±0.5 Five, M3.5 3.5 dia. Cover Two, M3 36±1 4.5 92±0.5 40±1 4.5 92±0.5 92±0.5 3.5 Two, M3 (Depth 4 mm max.) 20 S8JX-G100@@ (100 W) S8JX-G100@@C (100 W) S8JX-G15024 (150 W) S8JX-G15024C (150 W) S8JX-G15048 (150 W) S8JX-G15048C (150 W) Label Bottom Mounting 8 3.5 dia. 9.5 75±0.5 10 max. 100 W 26.5 20 65±0.5 150±1 150 W 5 max. 100·150 W Panel mounting holes dimensions Surface screw mounting Two, M3 3.5 8.2 75±0.5 Side Mounting 75±0.5 92±1 Five, M3.5 141±0.5 3.5 dia. Cover Two, M3 48±1 5 141±0.5 5 141±0.5 8 50±1 Bottom Mounting 141±0.5 Two, M3 (Depth 4 mm max.) 3.5 3.5 dia. 28 16 122±0.5 17 S8JX S8JX-G15005 (150 W) S8JX-G15005C (150 W) Panel mounting holes dimensions 12max. 2-M4 Label 5max. 178±1 Surface screw mounting 10 Two, M3 3.5 13 9.5 8.2 92±1 Side Mounting 68±0.5 68±0.5 3-M3.5 169±0.5 3.5 dia. Two, M3 Cover 60±1 5 169±0.5 5 169±0.5 8 Bottom Mounting 169±0.5 Two, M3 (Depth: 4 mm max.) 3.5 dia. 3.5 33.5 36 14 140±0.5 Input voltage switch S8JX-G15012 (150 W) S8JX-G15012C (150 W) Panel mounting holes dimensions 10max. 178±1 5max. Surface screw mounting Label Two, M3 9.5 8.2 3.5 92±1 Side Mounting 68±0.5 68±0.5 169±0.5 3.5 dia. 5-M3.5 Two, M3 Cover 60±1 5 169±0.5 5 169±0.5 8 Bottom Mounting 169±0.5 Two, M3 (Depth: 4 mm max.) 3.5 3.5 dia. 33.5 36 14 18 140±0.5 S8JX S8JX-G30024C (300 W) Eight, M4 holes (depth: 8 max. on both sides) 20 max. 4 max. Panel mounting holes dimensions 167.1±1 Nine, M4 terminal screws Surface screw mounting Four, 4.5 dia. 10 8.6 92±1 50±0.5 Side Mounting 50±0.5 136±0.5 21 19 110±1 Four, 4.5 dia. 136±0.5 Bottom Mounting 90±0.5 136±0.5 90±0.5 Four, M4 holes (depth: 8 max.) 10 19 136±0.5 S8JX-G60024C (600 W) Eight, M4 holes (depth: 8 max. on both sides) 150±1 8.6 Nine, M4 terminal screws 10 24.4±0.5 159.8±1 92±1 50±0.5 20.9 8.6 10 124±0.5 11 Panel mounting holes dimensions Surface screw mounting Four, 4.5 dia. Side Mounting Four, M4 holes (depth: 8 max.) 50±0.5 100±0.5 124±0.5 Four, 4.5 dia. Bottom Mounting 137±0.5 19 42 100±0.5 137±0.5 14.8 S8JX Mounting Bracket Provided with Front-mounting Power Supplies a 15-/35-/50-/100-/150-W Models S82Y-J00F Front-mounting Bracket Front-mounting Method Mounting dimensions Dimensions 1.5 4.6 15±0.2 11 9 Two, M3 Note: Mounting screws are not provided. Temporarily attach the enclosed mounting bracket as shown in the illustration on the right, hook the holes (parts a) in the Power Supply on hooks on the mounting bracket (parts b), and secure the Power Supply with two mounting screws. b a 60 60 Two, 3.5 dia. Mounting bracket Power Supply 74 4.6 5 b 20 11 20 31.5 4.7 15 t = 1.0 a 20.5 Material: Stainless steel 300-/600-W Models Front-mounting Bracket (S82Y-J30F) 10 dia. Attaching the Mounting Brackets Dimensions with Mounting Brackets 300-W Model R2.5 300-W Model 15 7.5 30 7.5 145±0.3 160 Two, 5 dia. 92 t = 1.6 145±0.3 48 Note: To provide ventilation space, the body will shift forward by 21.6 mm from the mounting surface. 32±0.2 Note: Mounting Brackets are provided in a set, one for the right side and one for the left side. 80±0.5 Four, M4 600-W Model 600-W Model 145±0.3 Note: To provide ventilation space, the body will shift forward by 23.6 mm from the mounting surface. 120±0.5 20 Four, M4 S8JX DIN Rail-mounting Models S8JX-G015@@D (15 W) S8JX-G015@@CD (15 W) S8JX-G035@@D (35 W) S8JX-G035@@CD (35 W) 14.5 max. 6 max. 44±1 90±1 10 max. Label 5 max. 9.5 8.2 91±1 Five, M3.5 47 Cover 98.6 7 (Sliding: 16.6 max.) S8JX-G050@@D (50 W) S8JX-G050@@CD (50 W) 6 max. 44±1 14.5 max. 100±1 10 max. Label 9.5 5 max. 8.2 92±1 47 Five, M3.5 Cover 36±1 108.6 7 (Sliding: 16.6 max.) 40±1 S8JX-G100@@D (100 W) S8JX-G100@@CD (100 W) S8JX-G15024D (150 W) S8JX-G15024CD (150 W) S8JX-G15048D (150 W) S8JX-G15048CD (150 W) 10 max. 6 max. 50±1 100 W 150±1 150 W 14.5 max. 100·150 W 5 max. Label 9.5 8.2 92±1 Five, M3.5 47 Cover 48±1 158.6 7 (Sliding: 16.6 max.) 50±1 21 S8JX S8JX-G15005D (150 W) S8JX-G15005CD (15 W) 6 max. 2-M4 14.5 max. 60±1 12 max. 5 max. 178±1 Label 10 13 9.5 8.2 92±1 47 3-M3.5 Cover 7 (Sliding: 16.6 max.) 186.6 Input voltage switch S8JX-G15012D (150 W) S8JX-G15012CD (150 W) 6 max. 14.5 max. 60±1 10 max. 178±1 5 max. Label 9.5 8.2 92±1 47 5-M3.5 Cover 186.6 22 7 (Sliding: 16.6 max.) S8JX S8JX-G30024CD (300 W) (17.7) 4 max. Nine, M4 terminal screws 20 max. 10.2 167.1±1 10 8.6 92±1 46.6 4.4 (Sliding: 10 max.) 4.6 max. 4.6 max. 110±1 181.3 Note: Use a metal DIN Rail when mounting a 300-W model to a DIN Rail. DIN Rail (Order Separately) Mounting Rail (Material: Aluminum) 7.3±0.15 4.5 35±0.3 15 25 10 25 25 1,000 (500) ∗ 15 (5) * 25 10 27±0.15 Model PFP-100N PFP-50N 1 * Value in parentheses are for PFP-50N. Mounting Rail (Material: Aluminum) 16 4.5 35±0.3 27 24 29.2 Model PFP-100N2 15 25 25 10 25 1,000 10 25 End Plate 15 1 1.5 10 6.2 M4 × 8 panhead screw 1.8 1 50 1.8 35.5 35.5 Model 11.5 PFP-M 10 M4 spring washer 1.3 4.8 Note: 1. If there is a possibility that the Unit will be subject to vibration or shock, use a steel DIN Rail. Otherwise, metallic filings may result from aluminum abrasion. 2. If the Unit may be subjected to sliding to either side, attach an End Plate (model PFP-M) on each side of the Unit. 23 S8JX Safety Precautions Refer to Safety Precautions for All Power Supplies. CAUTION Minor electric shock, fire, or Product failure may occasionally occur. Do not disassemble, modify, or repair the Product to touch the interior of the Product. 15-/35-/50-/100-/150-W Models Standard Mounting (Front-mounting and DIN Rail-mounting) Standard Mounting (Bottom-mounting) *1 *1 Minor burns may occasionally occur. Do not touch the Product while power is being supplied or immediately after power is turned OFF. *1 Fire may occasionally occur. Tighten terminal screws to the specified torque of 1.13 N·m. For the 5-V output terminal, tighten the terminal screw to 1.56 N·m. *2 *3 *1 Standard Mounting (Horizontal Mounting) *1 Minor injury due to electric shock may occasionally occur. Do not touch the terminals while power is being supplied. Always close the terminal cover after wiring. *1 *2 *3 300-W Model Minor electric shock, fire, or Product failure may occasionally occur. Do not allow any pieces of metal or conductors or any clippings or cuttings resulting from installation work to enter the Product. Standard Mounting (Front-mounting and DIN Rail-mounting) *1 Precautions for Safe Use Mounting • Take adequate measures to ensure proper heat dissipation to increase the long-term reliability of the Product. • Be sure to allow convection in the atmosphere around devices when mounting. Do not use in locations where the ambient temperature exceeds the range of the derating curve. (except 600 W) • The S8JX-@60024@ is designed to radiate heat by means of forced air-flow. Do not cover the air holes (provided at fan mounted side and the opposite side) to have enough air-cooling. • The screws must not protrude beyond the following values inside the Power Supply when screw holes provided on the chassis are used. 15 W, 35 W, 50 W, 100 W, or 150 W: 4 mm min. 300 W or 600 W: 8 mm min. Mounting screw tightening torque (recommended value) : 0.54 N·m. • Rear mounting is possible using provided mounting bracket. • When cutting out holes for mounting, make sure that cuttings do not enter the interior of the Products. • Improper mounting will interfere with heat dissipation and may occasionally result in deterioration or damage of internal parts. Use the standard mounting method only. • The internal parts may occasionally deteriorate and be broken due to adverse heat radiation. Do not loosen the screw on the side face of the main body. • When mounting two or more Power Supplies side-by-side, allow at least 20 mm spacing between them. • Provide a space of at least 20 mm back and forth when mounting 300-W and 600-W models as well. • Use the metal plate as the mounting panel. • Minor fire may occasionally occur. Set the input voltage switch to the input voltage that is to be used (150-W, 5-V models only). 24 *2 *1 Standard Mounting (Bottom-mounting) *1 *3 *2 600-W Model *1 *1 *3 *1. Convection of air *2. 20 mm max. *3. Use a metal plate as the mounting surface. *2 S8JX Wiring DIN Rail-mounting • Connect the ground completely. A protective earthing terminal stipulated in safety standards is used. Electric shock or malfunction may occur if the ground is not connected completely. • Minor fire may possibly occur. Ensure that input and output terminals are wired correctly. • Do not apply more than 75 N force to the terminal block when tightening it. • Be sure to remove the sheet covering the Product for machining before power-ON so that it does not interfere with heat dissipation. • Use the following material for the wires to be connected to the S8JX to prevent smoking or ignition caused by abnormal loads. Recommended Wire Type 15 W, 35 W AWG12 to AWG20 (a cross section of 0.517 to 3.309 mm2) UL-certified temperature of at least 75°C 50W, 100W, 150 W (except for 5 V) AWG12 to AWG16 (a cross section of 1.309 to 3.309 mm2) UL-certified temperature of at least 60°C or 60/75°C Input side 150 W at 5 V 300 W, 600 W AWG12 to AWG16 (a cross-section of 1.309 to 3.309 mm2) UL-certified temperature of at least 60°C or 60/75°C AWG8 to AWG14 (a cross-section of 2.081 to Output 8.368 mm2) side UL-certified temperature of at least 60°C or 60/75°C AWG12 to AWG20 (a cross section of 0.517 to 3.309 mm2) UL-certified temperature of at least 60°C or 60/75°C Installation Environment • Do not use the Power Supply in locations subject to shocks or vibrations. In particular, install the Power Supply as far away as possible from contactors or other devices that are a vibration source. • Install the Power Supply well away from any sources of strong, high-frequency noise and surge. Ambient Operating and Storage Environments • Store the Power Supply at a temperature of −25 to 65°C and a humidity of 25% to 90%. • The Internal parts may occasionally deteriorate or be damaged. Do not use the Power Supply outside the derating range (i.e., the area shown by shading A in the derating curve diagram on page 13.) • Use the Power Supply at a humidity of 25% to 85%. • Do not use the Power Supply in locations subject to direct sunlight. • Do not use locations where liquids, foreign matter, or corrosive gases may enter the interior of the Product. To mount the Power Supply to a DIN Rail, pull down the rail stopper until you hear it clicks open, hook portion (A) of the Power Supply onto the DIN Rail, press the Power Supply in direction (B), and then push up the rail stopper to lock the Power Supply in place. To dismount the Power Supply, pull down portion (C) with a flat-blade screwdriver and pull out the Power Supply. (C) Track stopper Series Operation Two power supplies can be connected in series. The (±) voltage output can be accomplished with two Power Supplies. Series Operation Correct Output Voltage (±) Correct AC (L) +V AC (L) +V AC (N) −V AC (N) −V AC (L) +V AC (L) +V AC (N) −V AC (N) −V Note: 1. If the load is short-circuited, a reverse voltage will be generated inside the Power Supply. If this occurs the Power Supply may possibly deteriorate or be damaged. Always connect a diode as shown in the figure. Select a diode having the following ratings. Type Schottky Barrier diode Dielectric strength (VRRM) Twice the rated output voltage or above Forward current (IF) Twice the rated output current or above 2. Although Products having different specifications can be connected in series, the current flowing through the load must not exceed the smaller rated output current. Parallel Operation 15-/35-/50-/100-/150-W Models The Product is not designed for parallel operation. Parallel Operation Incorrect AC (L) AC (N) AC (L) Overload Protection Charging a Battery When connecting a battery at the load, connect an overcurrent limiting circuit and overvoltage protection circuit. Output Voltage Adjuster (V.ADJ) • The output voltage adjuster (V.ADJ) may possibly be damaged if it is turned with unnecessary force. Do not turn the adjuster with excessive force. • After completing output voltage adjustment, be sure that the output capacity or output current does not exceed the rated output capacity or rated output current. (B) 30 mm min. AC (N) • Internal parts may possibly deteriorate or be damaged if a shortcircuited or overload state continues during operation. • Internal parts may possibly deteriorate or be damaged if the Power Supply is used for applications with frequent inrush current or overloading at the load end. Do not use the Power Supply for such applications. (A) +V −V +V −V 300-/600-W Models Parallel operation is possible under 80% of the rated value. • To operate in parallel, set the switch to the "PARALLEL" side. • The length and thickness of each wire connected to the load must be the same so that there is no difference in voltage drop value between the load and the output terminals of each Power Supply. • It is desirable to set the same value on the voltage adjuster of each Power Supply. Parallel Operation Correct AC (L) AC (N) AC (L) AC (N) +V −V +V −V 25 S8JX In Case There Is No Output Voltage The possible cause for no output voltage may be that the overcurrent or overvoltage protection has operated. The internal protection may operate if a large amount of surge voltage such as a lightening surge occurs while turning ON the Power Supply. In case there is no output voltage, please check the following points before contacting us: • Checking overcurrent protected status: Check whether the load is in overcurrent status or is shortcircuited. Remove wires to load when checking. • Checking overvoltage or internal protection: Turn the power supply OFF once, and leave it OFF for at least 7 minutes. Then turn it ON again to see if this clears the condition. Fan Replacement 600-W Model The service life of the fan is approximately 50,000 hours (at 25°C). The service life varies, however, depending on the ambient temperature or other surrounding environmental conditions such as dust. As a preventive maintenance measure, replace the fan within approx. two years if it is used at an ambient temperature of 40°C. Fans (S82Y-JXFAN) are available as replacements. Switching the AC Input Voltage between 100 and 200 VAC 150-W, 5-V Models The input voltage can be switched between 100 V and 200 V by using the input voltage switch. Make the setting shown in the following figure for the voltage that will be used. (The input voltage is factoryset to 200 V.) Fan Set: Fan (above), instruction sheet, and packing case Replace the fan as shown in the following illustration. "115V": 100 to 120 VAC The input voltage switch is at the back on the bottom of the Power Supply. "230V": 200 to 240 VAC 300-/600-W Models The input voltage can be switched between 100 and 200 V by shorting or opening the input voltage selection terminals. Set the required voltage as shown below. (The voltage is factory-set to 200 V.) 100-V input 200-V input L L N N VOLTAGE SELECT SHORT 100-120V OPEN 200-230V VOLTAGE SELECT SHORT 100-120V OPEN 200-230V SHORT BAR SHORT BAR Short with the short bar. Remove the short bar and leave the terminals open. Note: A 300-W model is shown above. ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. In the interest of product improvement, specifications are subject to change without notice. 26 Read and Understand this Catalog Please read and understand this catalog before purchasing the product. Please consult your OMRON representative if you have any questions or comments. Warranty and Limitations of Liability WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED. LIMITATIONS OF LIABILITY OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS, OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY. In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted. IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR. Application Considerations SUITABILITY FOR USE OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's application or use of the products. Take all necessary steps to determine the suitability of the product for the systems, machines, and equipment with which it will be used. Know and observe all prohibitions of use applicable to this product. NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. PROGRAMMABLE PRODUCTS OMRON shall not be responsible for the user’s programming of a programmable product, or any consequence thereof. Disclaimers CHANGE IN SPECIFICATIONS Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the products may be changed without any notice. When in doubt, special model numbers may be assigned to fix or establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual specifications of purchased products. DIMENSIONS AND WEIGHTS Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown. PERFORMANCE DATA Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of OMRON’s test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON Warranty and Limitations of Liability. OMRON Corporation Industrial Automation Company Authorized Distributor: Tokyo, JAPAN Contact: www.ia.omron.com Regional Headquarters OMRON EUROPE B.V. Wegalaan 67-69-2132 JD Hoofddorp The Netherlands Tel: (31)2356-81-300/Fax: (31)2356-81-388 OMRON ELECTRONICS LLC One Commerce Drive Schaumburg, IL 60173-5302 U.S.A. Tel: (1) 847-843-7900/Fax: (1) 847-843-7787 OMRON ASIA PACIFIC PTE. LTD. No. 438A Alexandra Road # 05-05/08 (Lobby 2), Alexandra Technopark, Singapore 119967 Tel: (65) 6835-3011/Fax: (65) 6835-2711 OMRON (CHINA) CO., LTD. Room 2211, Bank of China Tower, 200 Yin Cheng Zhong Road, PuDong New Area, Shanghai, 200120, China Tel: (86) 21-5037-2222/Fax: (86) 21-5037-2200 © OMRON Corporation 2009 All Rights Reserved. In the interest of product improvement, specifications are subject to change without notice. Printed in Japan CSM_9_1_0211 Cat. No. T041-E1-04 1110