OMRON S8JX

New Product
Switch Mode Power Supply
S8JX (15/35/50/100/150/300/600-W Models)
Wide Variety of Output Voltage
Variations: 48 V for 15 to 150 W,
and 5 or 12 V for 150 W
• Easy Mounting:
Mounting Bracket provided as a standard feature.
(except for DIN Rail-mounting models)
Mounts to DIN Rail. (except 600-W model)
Screw-mount at the top. (except 300-/600-W models)
• Safety standards:
UL 508/60950-1
cUL CSA C22.2 No. 107.1
cUR CSA C22.2 No. 60950-1
EN 50178 (= VDE 0160)
EN 60950-1 (= VDE 0805 Teil 1)
• EMC: Conforms to EN 61204-3 Class A.
EMI: EN55011
EMS: EN61000-4
• Input conditions:
The input voltage range of 15-W, 35-W,
50-W, 100-W, and 150-W models has been
increased to 80 to 370 VDC (EC Directives
and safety standards do not apply.).
(
)
Note: Refer to Safety Precautions on page 24.
Model Number Structure
Model Number Legend
Note: 1. Not all combinations are possible. Refer to List of Models in Ordering Information on page 2.
2. Estimates can be provided for coatings and other specifications that are not given in the datasheet. Ask your OMRON representative for
details.
15-/35-/50-/100-/150-W Models
S8JX-G@@@@@@@
1
1. Power Ratings
015: 15 W
035: 35 W
050: 50 W
100: 100 W
150: 150 W
2. Output Voltage
05: 5 V
12: 12 V
15: 15 V
24: 24 V
48: 48 V
2
3 4
3. Configuration (15/35/50/100/150 W model)
None: Open-frame
C: Covered
4. Configuration/mounting
None: Front-mounting
D: DIN Rail-mounting
300-/600-W Models
S8JX-G@@@@@@
1
1. Power Ratings
300: 300 W
600: 600 W
2
3
2. Output Voltage
24: 24 V
3. Configuration/mounting (covered type)
C: Front-mounting
CD: DIN Rail-mounting
Note: Estimates can be provided for coatings and other specifications that are not given in the datasheet. Ask your OMRON representative for
details.
1
S8JX
Ordering Information
List of Models
Note: For details on normal stock models, contact your nearest OMRON representative.
Configuration
Input voltage
Power ratings
15 W
35 W
Front-mounting *1
50 W
100 W
100 to 240 VAC
(free)
(80 to 370 VDC *3)
S8JX-G15005@:
Switchable between
100 to 120 VAC and
200 to 240 VAC. (DC
power cannot be
input.)
Open-frame Power
Supplies
150 W
15 W
35 W
DIN Rail-mounting *2
50 W
100 W
150 W
Output voltage (VDC)
5V
12 V
15 V
24 V
48 V
5V
12 V
15 V
24 V
48 V
5V
12 V
24 V
48 V
5V
12 V
24 V
48 V
5V
12 V
24 V
48 V
5V
12 V
15 V
24 V
48 V
5V
12 V
15 V
24 V
48 V
5V
12 V
24 V
48 V
5V
12 V
24 V
48 V
5V
12 V
24 V
48 V
Output current
3A
1.3 A
1A
0.65 A
0.35 A
7A
3A
2.4 A
1.5 A
0.75 A
10 A
4.2 A
2.1 A
1.1 A
20 A
8.5 A
4.5 A
2.1 A
30 A
13 A
6.5 A
3.3 A
3A
1.3 A
1A
0.65 A
0.35 A
7A
3A
2.4 A
1.5 A
0.75 A
10 A
4.2 A
2.1 A
1.1 A
20 A
8.5 A
4.5 A
2.1 A
30 A
13 A
6.5 A
3.3 A
*1. The front-mounting bracket is included as standard with the product.
*2. A front-mounting bracket is not included with the product.
*3. The range for compliance with EC Directives and safety standards (UL, EN, etc.) is 100 to 240 VAC (85 to 264 VAC).
2
Model
S8JX-G01505
S8JX-G01512
S8JX-G01515
S8JX-G01524
S8JX-G01548
S8JX-G03505
S8JX-G03512
S8JX-G03515
S8JX-G03524
S8JX-G03548
S8JX-G05005
S8JX-G05012
S8JX-G05024
S8JX-G05048
S8JX-G10005
S8JX-G10012
S8JX-G10024
S8JX-G10048
S8JX-G15005
S8JX-G15012
S8JX-G15024
S8JX-G15048
S8JX-G01505D
S8JX-G01512D
S8JX-G01515D
S8JX-G01524D
S8JX-G01548D
S8JX-G03505D
S8JX-G03512D
S8JX-G03515D
S8JX-G03524D
S8JX-G03548D
S8JX-G05005D
S8JX-G05012D
S8JX-G05024D
S8JX-G05048D
S8JX-G10005D
S8JX-G10012D
S8JX-G10024D
S8JX-G10048D
S8JX-G15005D
S8JX-G15012D
S8JX-G15024D
S8JX-G15048D
S8JX
Configuration
Input voltage
Power ratings
15 W
35 W
Front-mounting *1
50 W
100 W
100 to 240 VAC
(free)
(80 to 370 VDC *3)
S8JX-G15005@@:
Switchable between
100 to 120 VAC and
200 to 240 VAC. (DC
power cannot be
input.)
Covered Power
Supplies
150 W
15 W
35 W
DIN Rail-mounting *2
50 W
100 W
150 W
Front-mounting *1
DIN Rail-mounting *2
100 to 120 VAC
200 to 240 VAC
(Swichable)
300 W
600 W
300 W
Output voltage (VDC)
5V
12 V
15 V
24 V
48 V
5V
12 V
15 V
24 V
48 V
5V
12 V
24 V
48 V
5V
12 V
24 V
48 V
5V
12 V
24 V
48 V
5V
12 V
15 V
24 V
48 V
5V
12 V
15 V
24 V
48 V
5V
12 V
24 V
48 V
5V
12 V
24 V
48 V
5V
12 V
24 V
48 V
24 V
Output current
3A
1.3 A
1A
0.65 A
0.35 A
7A
3A
2.4 A
1.5 A
0.75 A
10 A
4.2 A
2.1 A
1.1 A
20 A
8.5 A
4.5 A
2.1 A
30 A
13 A
6.5 A
3.3 A
3A
1.3 A
1A
0.65 A
0.35 A
7A
3A
2.4 A
1.5 A
0.75 A
10 A
4.2 A
2.1 A
1.1 A
20 A
8.5 A
4.5 A
2.1 A
30 A
13 A
6.5 A
3.3 A
14 A
27 A
14 A
*1. The front-mounting bracket is included as standard with the product.
*2. A front-mounting bracket is not included with the product.
*3. The range for compliance with EC Directives and safety standards (UL, EN, etc.) is 100 to 240 VAC (85 to 264 VAC).
3
Model
S8JX-G01505C
S8JX-G01512C
S8JX-G01515C
S8JX-G01524C
S8JX-G01548C
S8JX-G03505C
S8JX-G03512C
S8JX-G03515C
S8JX-G03524C
S8JX-G03548C
S8JX-G05005C
S8JX-G05012C
S8JX-G05024C
S8JX-G05048C
S8JX-G10005C
S8JX-G10012C
S8JX-G10024C
S8JX-G10048C
S8JX-G15005C
S8JX-G15012C
S8JX-G15024C
S8JX-G15048C
S8JX-G01505CD
S8JX-G01512CD
S8JX-G01515CD
S8JX-G01524CD
S8JX-G01548CD
S8JX-G03505CD
S8JX-G03512CD
S8JX-G03515CD
S8JX-G03524CD
S8JX-G03548CD
S8JX-G05005CD
S8JX-G05012CD
S8JX-G05024CD
S8JX-G05048CD
S8JX-G10005CD
S8JX-G10012CD
S8JX-G10024CD
S8JX-G10048CD
S8JX-G15005CD
S8JX-G15012CD
S8JX-G15024CD
S8JX-G15048CD
S8JX-G30024C
S8JX-G60024C
S8JX-G30024CD
S8JX
Ratings, Characteristics, and Functions
Input specification
100 to 240 V input
Power ratings *1
Item
Efficiency
15 W
35 W
68% min.
73% min.
100 to 240 VAC (allowable range: 85 to 264 VAC)
Voltage *2
80 to 370 VDC *9
Note: This range is not applicable for the safety standards.
Frequency *2
Current *3
Input
50/60 Hz (47 to 450 Hz)
100 V input
0.4 A max.
200 V input
0.25 A max.
Power factor
Inrush current (for a
cold start at 25°C) *3
Output *4
0.6 A max.
---
Harmonic current emissions
Leakage current *3
1 A max.
---
100 V input
0.5 mA max.
200 V input
1 mA max.
100 V input
20 A max.
200 V input
40 A max.
Noise filter
Yes
Voltage adjustment range *5
−10% to 15% (with V. ADJ) (48-V models: ±10%)
Ripple *3
2% (p-p) max.
Input variation influence
0.4% max. with AC input voltage
Load variation influence
0.8% max. (0 to 100% load, rated input voltage)
Temperature variation influence
0.05%/°C max. (at rated input and output)
Startup time
500 ms max. (up to 90% of output voltage at rated input and output)
Hold time *3
20 ms min.
Overload protection *6
105% to 175% of rated load current, voltage drop, intermittent, automatic reset
Overvoltage protection *7
Yes
Additional Overheat protection
functions Parallel operation
No
No
Series operation
Yes (For up to two Power Supplies; external diodes required.)
Protective circuit operation indicator
No
Ambient operating temperature
Refer to the derating curve in Engineering Data on page 13 (with no icing or
condensation).
Storage temperature
−25 to 65°C (with no icing or condensation)
Ambient operating humidity
25% to 85% (Storage humidity: 25% to 90%)
Dielectric strength
3.0 kVAC for 1 min. (between all inputs and outputs; detection current: 20 mA)
2.0 kVAC for 1 min. (between all inputs and PE terminals; detection current: 20 mA)
1.0 kVAC for 1 min. (between all outputs and PE terminals; detection current: 20 mA)
Insulation resistance
100 MΩ min. (between all outputs and all inputs/PE terminals) at 500 VDC
Vibration resistance
10 to 55 Hz, 0.375-mm single amplitude for 2 h each in X, Y, and Z directions
Shock resistance
150 m/s2, 3 times each in ±X, ±Y, ±Z directions
Output indicator
EMI
Other
EMS
Yes (Color: Green)
Conducted Emissions
Conforms to EN 55011 Group 1 Class A and based on FCC Class A
Radiated Emissions
Conforms to EN 55011 Group 1 Class A
Electrostatic Discharge
Confirms to EN61000-4-2
Radiated Electromagnetic Field
Confirms to EN61000-4-3
Electrical Fast Transient/Burst
Confirms to EN61000-4-4
Surge
Confirms to EN61000-4-5
Conducted Disturbance
Confirms to EN61000-4-6
Voltage Dips/Short Interruptions Confirms to EN61000-4-11
UL Listed: UL 508 (Listing), UL UR: UL 60950-1 (Recognition)
Approved standards *9
cUL Listed: CSA C22.2 No.107.1
cUR: CSA C22.2 No. 60950-1
EN/VDE: EN50178 (= VDE 0160), EN 60950-1 (= VDE 0805 Teil 1)
(Terminal block: Based on DIN 50274 (VDE 0660-514))
SEMI
SEMI F47-0200 (200-VAC input)
Weight *8
250 g max.
*1. When a load is connected that has a built-in DC-DC converter, the overload protection may operate at startup and the Power Supply may not
start. Refer to Overload Protection on page 15.
*2. Do not use an Inverter output for the Power Supply. Inverters with an output frequency of 50/60 Hz are available, but the rise in the internal
temperature of the Power Supply may result in ignition or burning.
*3. Rated input voltage: 100 or 200 VAC at 100% load.
*4. Output characteristics: Specified at power supply output terminals.
*5. If the output voltage adjuster (V. ADJ) is turned, the voltage will increase by more than the allowable voltage range. When adjusting the output
voltage, confirm the actual output voltage from the Power Supply and be sure that load is not damaged.
*6. For details, refer to Overload Protection on page 15.
*7. To reset the protection, turn OFF the input power for seven minutes or longer and then turn it back ON.
*8. The weight indicated is a for Front-mounting, Open-frame Power Supply.
*9. The range for compliance with EC Directives and safety standards (UL, EN, etc.) is 100 to 240 VAC (85 to 264 VAC).
4
S8JX
Input specification
100 to 240 V input
Power ratings *1
Item
Efficiency
50 W
100 W
76% min.
100 to 240 VAC (allowable range: 85 to 264 VAC)
Voltage *2
80 to 370 VDC *9
Note: This range is not applicable for the safety standards.
Frequency *2
Current *3
Input
50/60 Hz (47 to 450 Hz)
100 V input
1.4 A max.
200 V input
0.8 A max.
Power factor
Inrush current (for a
cold start at 25°C) *3
Output *4
1.5 A max.
---
Harmonic current emissions
Leakage current *3
2.5 A max.
---
100 V input
0.5 mA max.
200 V input
1 mA max.
100 V input
20 A max.
200 V input
40 A max.
Noise filter
Yes
Voltage adjustment range *5
−10% to 15% (with V. ADJ) (48-V models: ±10%)
Ripple *3
2% (p-p) max.
Input variation influence
0.4% max. (with AC input voltage)
Load variation influence
0.8% max. (0 to 100% load, rated input voltage)
Temperature variation influence
0.05%/°C max. (at rated input and output)
Startup time
500 ms max. (up to 90% of output voltage at rated input and output)
Hold time *3
20 ms min.
Overload protection *6
105% to 175% of rated load current, voltage drop, intermittent, automatic reset
Overvoltage protection *7
Yes
Additional Overheat protection
functions Parallel operation
No
No
Series operation
Yes (For up to two Power Supplies; external diodes required.)
Protective circuit operation indicator
No
Ambient operating temperature
Refer to the derating curve in Engineering Data on page 13 (with no icing or
condensation).
Storage temperature
−25 to 65°C (with no icing or condensation)
Ambient operating humidity
25% to 85% (Storage humidity: 25% to 90%)
Dielectric strength
3.0 kVAC for 1 min. (between all inputs and outputs; detection current: 20 mA)
2.0 kVAC for 1 min. (between all inputs and PE terminals; detection current: 20 mA)
1.0 kVAC for 1 min. (between all outputs and PE terminals; detection current: 20 mA)
Insulation resistance
100 MΩ min. (between all outputs and all inputs/PE terminals) at 500 VDC
Vibration resistance
10 to 55 Hz, 0.375-mm single amplitude for 2 h each in X, Y, and Z directions
Shock resistance
150 m/s2, 3 times each in ±X, ±Y, ±Z directions
Output indicator
EMI
Other
EMS
Yes (Color: Green)
Conducted Emissions
Conforms to EN 55011 Group 1 Class A and based on FCC Class A
Radiated Emissions
Conforms to EN 55011 Group 1 Class A
Electrostatic Discharge
Confirms to EN61000-4-2
Radiated Electromagnetic Field
Confirms to EN61000-4-3
Electrical Fast Transient/Burst
Confirms to EN61000-4-4
Surge
Confirms to EN61000-4-5
Conducted Disturbance
Confirms to EN61000-4-6
Voltage Dips/Short Interruptions Confirms to EN61000-4-11
UL Listed: UL 508 (Listing), UL UR: UL 60950-1 (Recognition)
Approved standards *9
cUL Listed: CSA C22.2 No.107.1
cUR: CSA C22.2 No. 60950-1
EN/VDE: EN50178 (= VDE 0160), EN 60950-1 (= VDE 0805 Teil 1)
(Terminal block: Based on DIN 50274 (VDE 0660-514))
SEMI
SEMI F47-0200 (200-VAC input)
Weight *8
300 g max.
550 g max.
*1. When a load is connected that has a built-in DC-DC converter, the overload protection may operate at startup and the Power Supply may not
start. Refer to Overload Protection on page 15.
*2. Do not use an Inverter output for the Power Supply. Inverters with an output frequency of 50/60 Hz are available, but the rise in the internal
temperature of the Power Supply may result in ignition or burning.
*3. Rated input voltage: 100 or 200 VAC at 100% load.
*4. Output characteristics: Specified at power supply output terminals.
*5. If the output voltage adjuster (V. ADJ) is turned, the voltage will increase by more than the allowable voltage range. When adjusting the output
voltage, confirm the actual output voltage from the Power Supply and be sure that load is not damaged.
*6. For details, refer to Overload Protection on page 15.
*7. To reset the protection, turn OFF the input power for seven minutes or longer and then turn it back ON.
*8. The weight indicated is a for Front-mounting, Open-frame Power Supply.
*9. The range for compliance with EC Directives and safety standards (UL, EN, etc.) is 100 to 240 VAC (85 to 264 VAC).
5
S8JX
Input specification
Efficiency
Voltage *2
Frequency *2
Current *3
Input
Inrush current (for a
cold start at 25°C) *3
78% min.
79% min.
Switchable between 100 to
120 VAC (allowable range:
85 to 132 VAC) and 200 to
240 VAC (allowable range:
170 to 264 VAC).
100 to 240 VAC (allowable range: 85 to 264 VAC)
85% min.
80 to 370 VDC *9
50/60 Hz (47 to 450 Hz)
3.5 A max.
3.6 A max.
3.5 A max.
200 V input
2.1 A max.
2.2 A max.
2.1 A max.
Power factor
Leakage current *3
100 to 240 V input
150 W at 12 V
150 W at 24 or 48 V
150 W at 5 V
100 V input
---
Harmonic current emissions
Output *4
100/200 V switchable
Power ratings *1
Item
---
100 V input
0.5 mA max.
200 V input
1 mA max.
100 V input
20 A max.
200 V input
40 A max.
Noise filter
Yes
Voltage adjustment range *5
−10% to 15% (with V. ADJ) (48-V models: ±10%)
Ripple *3
2% (p-p) max.
Input variation influence
0.4% max. (with AC input voltage)
Load variation influence
0.8% max. (0 to 100% load, rated input voltage)
Temperature variation influence
0.05%/°C max. (at rated input and output)
Startup time
500 ms max. (up to 90% of output voltage at rated input and output)
Hold time *3
20 ms min.
Overload protection *6
105% to 175% of rated load
current, voltage drop,
automatic reset
Overvoltage protection *7
Additional
functions Overheat protection
Parallel operation
105% to 175% of rated load current, voltage drop,
intermittent, automatic reset
Yes
No
No
Series operation
Yes (For up to two Power Supplies; external diodes required.)
Protective circuit operation indicator
No
Ambient operating temperature
Refer to the derating curve in Engineering Data on page 13 (with no icing or
condensation).
Storage temperature
−25 to 65°C (with no icing or condensation)
Ambient operating humidity
25% to 85% (Storage humidity: 25% to 90%)
Dielectric strength
3.0 kVAC for 1 min. (between all inputs and outputs; detection current: 20 mA)
2.0 kVAC for 1 min. (between all inputs and PE terminals; detection current: 20 mA)
1.0 kVAC for 1 min. (between all outputs and PE terminals; detection current: 20 mA)
Insulation resistance
100 MΩ min. (between all outputs and all inputs/PE terminals) at 500 VDC
Vibration resistance
10 to 55 Hz, 0.375-mm single amplitude for 2 h each in X, Y, and Z directions
Shock resistance
150 m/s2, 3 times each in ±X, ±Y, ±Z directions
Output indicator
EMI
Other
EMS
Yes (Color: Green)
Conducted Emissions
Conforms to EN 55011 Group 1 Class A and based on FCC Class A
Radiated Emissions
Conforms to EN 55011 Group 1 Class A
Electrostatic Discharge
Confirms to EN61000-4-2
Radiated Electromagnetic Field
Confirms to EN61000-4-3
Electrical Fast Transient/Burst
Confirms to EN61000-4-4
Surge
Confirms to EN61000-4-5
Conducted Disturbance
Confirms to EN61000-4-6
Voltage Dips/Short Interruptions Confirms to EN61000-4-11
UL Listed: UL 508 (Listing), UL UR: UL 60950-1 (Recognition)
Approved standards *9
cUL Listed: CSA C22.2 No.107.1
cUR: CSA C22.2 No. 60950-1
EN/VDE: EN50178 (= VDE 0160), EN 60950-1 (= VDE 0805 Teil 1)
(Terminal block: Based on DIN 50274 (VDE 0660-514))
SEMI
---
Weight *8
800 g max.
SEMI F47-0200 (200-VAC input)
700 g max.
600 g max.
*1. When a load is connected that has a built-in DC-DC converter, the overload protection may operate at startup and the Power Supply may not
start. Refer to Overload Protection on page 15.
*2. Do not use an Inverter output for the Power Supply. Inverters with an output frequency of 50/60 Hz are available, but the rise in the internal
temperature of the Power Supply may result in ignition or burning.
*3. Rated input voltage: 100 or 200 VAC at 100% load.
*4. Output characteristics: Specified at power supply output terminals.
*5. If the output voltage adjuster (V. ADJ) is turned, the voltage will increase by more than the allowable voltage range. When adjusting the output
voltage, confirm the actual output voltage from the Power Supply and be sure that load is not damaged.
*6. For details, refer to Overload Protection on page 15.
*7. To reset the protection, turn OFF the input power for seven minutes or longer and then turn it back ON.
*8. The weight indicated is a for Front-mounting, Open-frame Power Supply.
*9. The range for compliance with EC Directives and safety standards (UL, EN, etc.) is 100 to 240 VAC (85 to 264 VAC).
6
S8JX
Input specification
Efficiency
300 W
Current *3
50/60 Hz (47 to 450 Hz)
100 V input
8 A max.
200 V input
4.5 A max.
Power factor
Inrush current (for a
cold start at 25°C) *3
14 A max.
8 A max.
---
Harmonic current emissions
Leakage current *3
80% min.
100 to 120 VAC (allowable range: 85 to 132 VAC)
200 to 240 VAC (allowable range: 170 to 264 VAC)
(Switchable)
Frequency *2
---
100 V input
0.5 mA max.
200 V input
1 mA max.
100 V input
25 A max.
30 A max.
200 V input
50 A max.
60 A max.
Noise filter
Output *4
600 W
82% min.
Voltage *2
Input
100/200 V (Selected)
Power ratings *1
Item
Yes
Voltage adjustment range *5
−10% to 15% (with V. ADJ)
Ripple *3
2% (p-p) max.
Input variation influence
0.4% max.
Load variation influence
0.8% max. (0 to 100% load, rated input voltage)
Temperature variation influence
0.05%/°C max.
Startup time
650 ms max.
Hold time *3
20 ms min.
Overload protection *6
105% to 175% of rated load current,
voltage drop, intermittent, automatic reset
Overvoltage protection *7
Additional
functions Overheat protection
Parallel operation
Series operation
500 ms max.
105% to 175% of rated load current, Inverted
L voltage drop, the circuit will be shut OFF
when the overload exceeds 5 s. *9
Yes
Yes *9
No
Yes *9
Yes (up to 5 units)
Yes (For up to two Power Supplies; external diodes required.)
Protective circuit operation indicator
No
Ambient operating temperature
Refer to the derating curve in Engineering Data on page 13 (with no icing or condensation).
Storage temperature
−25 to 65°C (with no icing or condensation)
Ambient operating humidity
25% to 85% (Storage humidity: 25% to 90%)
Dielectric strength
3.0 kVAC for 1 min. (between all inputs and outputs; detection current: 25 mA)
2.0 kVAC for 1 min. (between all inputs and PE terminals; detection current: 25 mA)
1.0 kVAC for 1 min. (between all outputs and PE terminals; detection current: 25 mA)
Insulation resistance
100 MΩ min. (between all outputs and all inputs/PE terminals) at 500 VDC
Vibration resistance
10 to 55 Hz, 0.375-mm single amplitude for 2 h each in X, Y, and Z directions
Shock resistance
150 m/s2, 3 times each in ±X, ±Y, ±Z directions
Output indicator
EMI
Other
EMS
Yes (color: red)
Yes (Color: Green)
Conducted Emissions *3
Conforms to EN 55011 Group 1 Class A and based on FCC Class A
Radiated Emissions
Conforms to EN 55011 Group 1 Class A
Electrostatic Discharge
Confirms to EN61000-4-2
Radiated Electromagnetic Field
Confirms to EN61000-4-3
Electrical Fast Transient/Burst
Confirms to EN61000-4-4
Surge
Confirms to EN61000-4-5
Conducted Disturbance
Confirms to EN61000-4-6
Voltage Dips/Short Interruptions Confirms to EN61000-4-11
UL UR: UL 508 (Recognition), UL UR: UL 60950-1 (Recognition)
Approved standards *10
cUL Listed: CSA C22.2 No.107.1
cUR: CSA C22.2 No. 60950-1
EN/VDE: EN50178 (= VDE 0160), EN 60950-1 (= VDE 0805 Teil 1)
(Terminal block: Based on DIN 50274 (VDE 0660-514))
SEMI
SEMI F47-0200 (200-VAC input)
Weight *8
1,600 g max.
2,500 g max.
*1. When a load is connected that has a built-in DC-DC converter, the overload protection may operate at startup and the Power Supply may not
start. Refer to Overload Protection on page 15.
*2. Do not use an Inverter output for the Power Supply. Inverters with an output frequency of 50/60 Hz are available, but the rise in the internal
temperature of the Power Supply may result in ignition or burning.
*3. Rated input voltage: 100 or 200 VAC at 100% load.
*4. Output characteristics: Specified at power supply output terminals.
*5. If the output voltage adjuster (V. ADJ) is turned, the voltage will increase by more than the allowable voltage range. When adjusting the output
voltage, confirm the actual output voltage from the Power Supply and be sure that load is not damaged.
*6. For details, refer to Overload Protection on page 15.
*7. To reset the protection, turn OFF the input power for three minutes or longer and then turn it back ON.
*8. The weight indicated is a for Front-mounting, Open-frame Power Supply.
*9. The protection-ON alarm indicator will light as soon as the output is interrupted. For resetting, turn OFF the input power, leave for more than
three minutes , and then turn it back ON again.
*10.The range for compliance with EC Directives and safety standards (UL, EN, etc.) is 100 to 240 VAC (85 to 264 VAC).
7
S8JX
Connections
Block Diagrams
S8JX-G01505@@ (15 W)
S8JX-G01512@@ (15 W)
S8JX-G01515@@ (15 W)
S8JX-G01524@@ (15 W)
AC (L)
INPUT
+V
Fuse
2.0 A
Noise
filter
DC OUTPUT
−V
AC (N)
Inrush current
protection
Rectifier
Smoothing
circuit
Rectifier/
Smoothing circuit
Drive control
Circuit
Overcurrent
detection
circuit
Voltage
detection
Overvoltage
detection circuit
Photocoupler
S8JX-G01548@@ (15 W)
+V
AC (L)
INPUT
Fuse:
2.0 A
Noise
filter
DC OUTPUT
−V
AC (N)
Inrush current
protection
Rectifier
Smoothing
circuit
Rectifier/
smoothing circuit
Drive control
circuit
Overcurrent
detection
circuit
Voltage
detection circuit
Overvoltage
detection circuit
Photocoupler
S8JX-G03505@@ (35 W)
S8JX-G03512@@ (35 W)
S8JX-G03515@@ (35 W)
S8JX-G03524@@ (35 W)
AC (L)
INPUT
+V
Fuse
3.15 A
Noise
filter
DC OUTPUT
−V
AC (N)
Inrush current
protection
Rectifier
Smoothing
circuit
Rectifier/
Smoothing circuit
Drive control
Circuit
Overcurrent
detection
circuit
Voltage
detection
Overvoltage
detection circuit
Photocoupler
S8JX-G03548@@ (35 W)
+V
AC (L)
INPUT
Fuse:
3.15 A
Noise
filter
DC OUTPUT
−V
AC (N)
Rectifier
Inrush current
protection
Smoothing
circuit
Rectifier/
smoothing circuit
Drive control
circuit
Overcurrent
detection
circuit
Voltage
detection circuit
Overvoltage
detection circuit
Photocoupler
8
S8JX
S8JX-G05005@@ (50 W)
S8JX-G05012@@ (50 W)
S8JX-G05024@@ (50 W)
AC (L)
INPUT
+V
Fuse
6.3 A
Noise
filter
DC OUTPUT
−V
AC (N)
Inrush current
protection
Rectifier
Smoothing
circuit
Rectifier/
Smoothing circuit
Drive control
Circuit
Overcurrent
detection
circuit
Voltage
detection
Overvoltage
detection circuit
Photocoupler
S8JX-G05048@@ (50 W)
+V
AC (L
INPUT
Fuse:
6.3 A
Noise
filter
DC OUTPUT
−V
AC (N)
Inrush current
protection
Rectifier
Smoothing
circuit
Rectifier/
smoothing circuit
Drive control
circuit
Overcurrent
detection
circuit
Voltage
detection circuit
Overvoltage
detection circuit
Photocoupler
S8JX-G100@@@@ (100 W)
AC (L)
INPUT
+V
Fuse
8A
Noise
filter
DC OUTPUT
−V
AC (N)
Inrush current
protection
Rectifier
Smoothing
circuit
Rectifier/
Smoothing circuit
Drive control
Circuit
Overcurrent
detection
circuit
Voltage
detection
Overvoltage
detection circuit
Photocoupler
9
S8JX
S8JX-G15005@@ (150 W)
Rectifier/
smoothing circuit
㧗V
AC (L)
INPUT
Fuse:
8A
Noise
filter
DC OUTPUT
㧙V
AC (N)
Rectifier/
smoothing circuit
Inrush current protection
Drive control
circuit
Overcurrent
detection
circuit
Voltage
detection circuit
Overvoltage
detection circuit
Photocoupler
Input voltage switch
100/200 V switching
Note: Set the input voltage switch to "115V" for 100 to 120 VAC and to "230V" for 200 to 240 VAC.
S8JX-G15012@@ (150 W)
S8JX-G15024@@ (150 W)
S8JX-G15048@@ (150 W)
+V
AC (L)
INPUT
Fuse
10 A
Noise
filter
DC OUTPUT
−V
AC (N)
Inrush current
protection
Rectifier
Smoothing
circuit
Rectifier/
Smoothing circuit
Drive control
Circuit
Overcurrent
detection
circuit
Voltage
detection
Overvoltage
detection circuit
Photocoupler
10
S8JX
S8JX-G30024@@ (300 W)
Rectifier/
Smoothing circuit
+V
AC (L)
Fuse
10 A
INPUT
Noise
filter
DC OUTPUT
−V
AC (N)
Inrush current protection
Rectifier/
Smoothing circuit
100/200V (Selectable)
Drive control
Circuit
Overcurrent
detection
circuit
Voltage
detection
Overvoltage
detection circuit
Photocoupler
Parallel operation selector
Note: Short-circuit the input voltage selector terminals if the input is 100 to 120 VAC.
Keep the terminals open if the input is 200 to 240 VAC.
S8JX-G60024@@ (600 W)
Rectifier/
Smoothing circuit
+V
AC (L)
Fuse
10 A
INPUT
Noise
filter
DC OUTPUT
−V
AC (N)
Inrush current protection
Rectifier/
Smoothing circuit
Fan
100/200V (Selectable)
Drive control
Circuit
Overcurrent
detection
circuit
Voltage
detection
Overheat
detection
circuit
Overvoltage
detection circuit
Photocoupler
Parallel operation selector
Note: Short-circuit the input voltage selector terminals if the input is 100 to 120 VAC.
Keep the terminals open if the input is 200 to 240 VAC.
11
S8JX
Construction and Nomenclature
Nomenclature
15-/35-/50-/100-/150-W Models
No.
D
E
D
E
A
+V
−V
−V
C
C
AC (L)
B
B
AC (N)
2
AC Input Terminals
(L), (N)
Connect the input lines to these terminals. *1
3
Protective Earth
Terminal (PE) (
Connect the ground line to these terminals. *2
4
Output Voltage
Adjuster (V. ADJ)
Use to adjust the voltage.
5
Output Indicator
(DC ON: Green)
Lights green while a direct current (DC) output is ON.
6
Input voltage switch
Switches the internal circuits according to the input
voltage.
"115V": 100 to 120 VAC
"230V": 200 to 240 VAC
AC (L)
AC (N)
Function
1
+V
A
Name
DC Output
Connect the load lines to these terminals.
Terminals (−V), (+V)
F
)
Bottom
100 to 120 VAC
Note: The S8JX-G05024CD is
shown above.
200 to 240 VAC
*1. The fuse is located on the (L) side. It is NOT user-replaceable. For a DC
power input, connect the low side to the positive (+) terminal.
Note: The S8JX-G15005C is shown
*2. This is the protective earth terminal specified in the safety standards.
above.
Always ground this terminal.
300-W Model
600-W Model
A
E
F
A
AC (L)
+V
AC (N)
+V
FE G
−V −V +V +V
B
Side
D
−V
−V
C
H
Bottom
H
AC (L)
AC (N)
D
No.
1
Name
2
AC Input Terminals (L), (N)
Protective Earth Terminal (PE) (
C
Function
DC Output Terminals (+V), (−V)
3
B
Connect the load lines to these terminals.
Connect the input lines to these terminals. *1
)
Connect the ground line to these terminals. *2
4
Input Voltage Selector Terminals
Short-circuit the terminals if the input is 100 to 120 VAC and open the terminals if the input is 200 to 230 VAC.
5
Output Indicator (DC ON: Green)
Lights while a Direct Current (DC) output is ON.
6
Output Voltage Adjuster (V. ADJ)
It is possible to increase or decrease the output voltage.
7
Protection-ON Alarm Indicator
(DC ON: Red)
The red indicator will be lit if the overvoltage (for a 600-W model) or overheat protection (for a 600-W model)
circuit is triggered. This indicator will also be lit when overload (for a 600-W model) is detected.
8
Selector of Parallel Operation
Set the selector to PARALLEL if the Units are in parallel operation.
*1. The fuse is located on the (L) side. It is NOT user-replaceable.
*2. This is the protective earth terminal specified in the safety standards. Always ground this terminal.
Reference Values
Reliability (MTBF)
12
S8JX-G15012@@ and S8JX-G15005@@
Other models
240,000 hrs
250,000 hrs
Definition
MTBF stands for Mean Time Between Failures, which is calculated according to the probability of accidental device
failures, and indicates reliability of devices.
Therefore, it does not necessarily represent a life of the product.
Life expectancy
10 yrs. min.
Definition
The life expectancy indicates average operating hours under the ambient temperature of 40°C and a load rate of 50%.
Normally this is determined by the life expectancy of the built-in aluminum electrolytic capacitor.
S8JX
Engineering Data
Derating Curves (Standard Mounting)
15-/35-/50-/100-/150-W Models
Covered Power Supplies
120
100
A
Load rate (%)
Load rate (%)
Open-frame Power Supplies
120
100
80
80
60
60
40
40
20
20
0
−20 −10
0
10
20
0
−20 −10
30 40 50 60 70 80
Ambient Temperature (°C)
A
0
10
20
30 40 50 60 70 80
Ambient Temperature (°C)
Note: 1. Internal parts may occasionally deteriorate or be damaged. Do not use the Power Supply in areas outside the derating curve (i.e., the
area shown by shading A in the above graph).
2. If there is a derating problem, use forced air-cooling.
3. For Customers Using a DC Input
When using an input voltage of less than 100 VDC, reduce the load calculated with the above derating curve by at least the following
coefficients.
35-W and 100-W (5-V or 12-V output) models: 0.8
50-W/150-W models:
0.85 (DC power cannot be input only to the S8JX-G15005@@.)
15-W and 100-W (24-V or 48-V output):
0.9
300-/600-W Models
Parallel Operation
120
100
A
Load rate (%)
Load rate (%)
Single Unit Operation
120
100
80
80
60
60
40
40
20
20
A
Solid line
0
−20 −10
0
10
20
30 40 50 60 70 80
Ambient Temperature (°C)
0
−20 −10
Dotted line
0
10
20
Front-mounting,
Bottom-mounting,
DIN Rail mounting,
Side mounting (600W)
Side mounting (300W)
30 40 50 60 70 80
Ambient Temperature (°C)
Note: 1. Internal parts may occasionally deteriorate or be damaged. Do not use the Power Supply in areas outside the derating curve (i.e., the
area shown by shading A in the above graph).
2. If there is a derating problem, use forced air-cooling.
13
S8JX
Mounting
15-/35-/50-/100-/150-W Models
The following three mounting methods are possible.
A. Front-mounting: Refer to Mounting Bracket Provided with Front-mounting Power Supplies a on page 20.
B. Bottom-mounting
C. Side-mounting
Note: Additional mounting methods are also available using DIN Rail-mounting models.
B
C
Standard Mounting
15-/35-/50-/100-/150-W Models
Front-mounting
Bottom-mounting
DIN Rail-mounting
Vertical Side-mounting
Horizontal Side-mounting
*
*
*
*
Note: 1. Improper mounting will interfere with heat dissipation and may occasionally result in deterioration or damage of internal parts. Use the
standard mounting method only.
2. When mounting the Power Supply, mounting it to a metal plate (*) is recommended.
3. Install the Power Supply so that the air flow circulates around the Power Supply, as the Power Supply is designed to radiate heat by
means of natural air flow.
300-W Model
Bottom-mounting
Front-mounting
20mm min.
20mm min.
Side-mounting
20mm min.
20mm min.
DIN Rail mounting
Note: 1. Improper mounting will interfere with heat dissipation and may occasionally result in deterioration or
damage of internal parts. Use the standard mounting method only.
2. When mounting the Power Supply, mounting it to a metal plate (*) is recommended.
3. Install the Power Supply so that the air flow circulates around the Power Supply, as the Power Supply
is designed to radiate heat by means of natural air flow.
600-W Model
Front-mounting
Bottom-mounting
20mm min.
Side-mounting
14
20mm min.
20mm min.
20mm min.
Note: 1. Improper mounting will interfere with heat dissipation and may occasionally
result in deterioration or damage of internal parts. Use the standard mounting
method only.
2. When mounting the Power Supply, mounting it to a metal plate (*) is
recommended.
3. Install the Power Supply so that the air flow circulates around the Power
Supply, as the Power Supply is designed to radiate heat by means of natural
air flow.
S8JX
Overload Protection
The Power Supply is provided with an overload protection function that protects the power supply from possible damage by overcurrent. When the
output current rises above 105% to 175% min. of the rated current, the protection function is triggered, decreasing the output voltage. When the
output current falls within the rated range, the overload protection function is automatically cleared.
(Reference value)
600-W Model
Output voltage (V)
Output voltage (V)
15-/35-/50-/100-/150-W (12-/24-/48-V) Models
Intermittent operation
Output interrupted
0
50
100
Load rate (%)
Output voltage [V]
150-W, 5-V Models
0
50
100
Load rate (%)
Output voltage (V)
300-W Model
Intermittent operation
0
15
50
100
Load rate (%)
0
50
100
Load rate (%)
If an excessive current flows for 5 s or more, the output will be turned
OFF and simultaneously the protection-ON alarm indicator will be lit.
To reset the S8JX, turn OFF the power, leave the S8JX for at least
three minutes, and then turn it ON again.
Note: 1. When a load is connected that has a built-in DC-DC
converter, the overload protection may operate at startup
and the power supply may not start.
2. Internal parts may occasionally deteriorate or be damaged
if a short-circuited or overcurrent state continues during
operation.
3. Internal parts may possibly deteriorate or be damaged if the
Power Supply is used for applications with frequent inrush
current or overloading at the load end. Do not use the Power
Supply for such applications.
S8JX
Overvoltage Protection
15-/35-/50-/100-/150-W Models
Consider the possibility of an overvoltage and design the system so that the load will not be subjected to an excessive voltage even if the feedback
circuit in the power supply fails. When an excessive voltage that is approximately 130% of the rated voltage or more is output, the output voltage
is shut OFF, preventing damage to the load due to overvoltage. Reset the input power by turning it OFF for at least seven minutes and then turning
it back ON again.
300-/600-W Models
Consider the possibility of an overvoltage and design the system so that the load will not be subjected to an excessive voltage even if the feedback
circuit in the Power Supply fails. When an excessive voltage that is approximately 120% of the rated voltage or more is output, the output voltage
is shut OFF, preventing damage to the load due to overvoltage. Reset the input power by turning it OFF for at least three minute and then turning
it back ON again.
Output voltage (V)
(Reference value)
Overvoltage protection
Operating
Rated output
Voltage
Variable range
0V
Note: Do not turn ON the power again until the cause of the overvoltage has been removed.
Overheat Protection
600-W Model
If the internal temperature rises excessively as a result of fan failure or any other reason, the overheat protection circuit will be triggered to shut
OFF the output voltage and simultaneously the protection-ON alarm indicator will be lit. Reset the input power by turning it OFF for at least three
minutes and then turning it back ON again.
Inrush Current, Startup Time, Output Hold Time
Input ON
Input OFF
AC input
voltage
Inrush current on input application
AC input
current
96.5%
90%
Output
voltage
Startup time
Hold time (20 ms min.)
Note: A maximum startup time of 500 ms is required (650 ms for 300 W). Construct a system configuration that considers the startup time of other
devices.
16
S8JX
Dimensions
(Unit: mm)
Front-mounting Models
S8JX-G015@@ (15 W)
S8JX-G015@@C (15 W)
S8JX-G035@@ (35 W)
S8JX-G035@@C (35 W)
Panel mounting holes dimensions
5 max.
90±1
10 max.
Surface screw mounting
Label
9.5
Two, M3
3.5
8.2
Side
Mounting
91±1
75±0.5
75±0.5
82±0.5
Five, M3.5
3.5 dia.
Two, M3
Cover
35.5±1
39.5±1
4.5
82±0.5
8.5
78±0.5
Bottom
Mounting
7.5
78±0.5
3.5
3.5 dia.
26.5
17.5
Two, M3 (Depth 4 mm max.)
50±0.5
15
S8JX-G050@@ (50 W)
S8JX-G050@@C (50 W)
5 max.
100±1
10 max.
Panel mounting holes dimensions
Label
9.5
Surface screw mounting
Two, M3
3.5
8.2
Side
Mounting
75±0.5
92±1
92±0.5
Five, M3.5
3.5 dia.
Cover
Two, M3
36±1
4.5
92±0.5
40±1
4.5
92±0.5
92±0.5
3.5
Two, M3
(Depth 4 mm max.)
20
S8JX-G100@@ (100 W)
S8JX-G100@@C (100 W)
S8JX-G15024 (150 W)
S8JX-G15024C (150 W)
S8JX-G15048 (150 W)
S8JX-G15048C (150 W) Label
Bottom
Mounting
8
3.5 dia.
9.5
75±0.5
10 max.
100 W
26.5
20
65±0.5
150±1
150 W
5 max.
100·150 W
Panel mounting holes dimensions
Surface screw mounting
Two, M3
3.5
8.2
75±0.5
Side
Mounting
75±0.5
92±1
Five, M3.5
141±0.5
3.5 dia.
Cover
Two, M3
48±1
5
141±0.5
5
141±0.5
8
50±1
Bottom
Mounting
141±0.5
Two, M3
(Depth 4 mm max.)
3.5
3.5 dia.
28
16
122±0.5
17
S8JX
S8JX-G15005 (150 W)
S8JX-G15005C (150 W)
Panel mounting holes dimensions
12max.
2-M4
Label
5max.
178±1
Surface screw mounting
10
Two, M3
3.5
13
9.5
8.2
92±1
Side
Mounting
68±0.5
68±0.5
3-M3.5
169±0.5
3.5 dia.
Two, M3
Cover
60±1
5
169±0.5
5
169±0.5
8
Bottom
Mounting
169±0.5
Two, M3
(Depth: 4 mm max.)
3.5 dia.
3.5
33.5 36
14
140±0.5
Input voltage switch
S8JX-G15012 (150 W)
S8JX-G15012C (150 W)
Panel mounting holes dimensions
10max.
178±1
5max.
Surface screw mounting
Label
Two, M3
9.5
8.2
3.5
92±1
Side
Mounting
68±0.5
68±0.5
169±0.5
3.5 dia.
5-M3.5
Two, M3
Cover
60±1
5
169±0.5
5
169±0.5
8
Bottom
Mounting
169±0.5
Two, M3
(Depth: 4 mm max.)
3.5
3.5 dia.
33.5 36
14
18
140±0.5
S8JX
S8JX-G30024C (300 W)
Eight, M4 holes
(depth: 8 max. on both sides)
20 max.
4 max.
Panel mounting holes dimensions
167.1±1
Nine, M4 terminal screws
Surface screw mounting
Four, 4.5 dia.
10
8.6
92±1
50±0.5
Side
Mounting
50±0.5
136±0.5
21
19
110±1
Four, 4.5 dia.
136±0.5
Bottom
Mounting
90±0.5
136±0.5
90±0.5
Four, M4 holes
(depth: 8 max.)
10
19
136±0.5
S8JX-G60024C (600 W)
Eight, M4 holes
(depth: 8 max. on both sides)
150±1
8.6
Nine, M4 terminal screws
10
24.4±0.5
159.8±1
92±1
50±0.5
20.9
8.6
10
124±0.5
11
Panel mounting holes dimensions
Surface screw mounting
Four, 4.5 dia.
Side
Mounting
Four, M4 holes
(depth: 8 max.)
50±0.5
100±0.5
124±0.5
Four, 4.5 dia.
Bottom
Mounting
137±0.5
19
42
100±0.5
137±0.5
14.8
S8JX
Mounting Bracket Provided with Front-mounting Power Supplies a
15-/35-/50-/100-/150-W Models
S82Y-J00F Front-mounting
Bracket
Front-mounting Method
Mounting
dimensions
Dimensions
1.5
4.6 15±0.2
11
9
Two, M3
Note: Mounting screws are
not provided.
Temporarily attach the enclosed mounting
bracket as shown in the illustration on the right,
hook the holes (parts a) in the Power Supply on
hooks on the mounting bracket (parts b), and
secure the Power Supply with two mounting
screws.
b
a
60
60
Two, 3.5 dia.
Mounting bracket
Power Supply
74
4.6
5
b
20
11
20
31.5
4.7
15
t = 1.0
a
20.5
Material: Stainless steel
300-/600-W Models
Front-mounting Bracket (S82Y-J30F)
10 dia.
Attaching the Mounting Brackets
Dimensions with
Mounting Brackets
300-W Model
R2.5
300-W Model
15
7.5
30
7.5
145±0.3
160
Two, 5 dia.
92
t = 1.6
145±0.3
48
Note: To provide ventilation space, the body
will shift forward by 21.6 mm from the
mounting surface.
32±0.2
Note: Mounting Brackets are provided in a set, one
for the right side and one for the left side.
80±0.5
Four, M4
600-W Model
600-W Model
145±0.3
Note: To provide ventilation space, the body
will shift forward by 23.6 mm from the
mounting surface.
120±0.5
20
Four, M4
S8JX
DIN Rail-mounting Models
S8JX-G015@@D (15 W)
S8JX-G015@@CD (15 W)
S8JX-G035@@D (35 W)
S8JX-G035@@CD (35 W)
14.5 max.
6 max.
44±1
90±1
10 max.
Label
5 max.
9.5
8.2
91±1
Five, M3.5
47
Cover
98.6
7 (Sliding: 16.6 max.)
S8JX-G050@@D (50 W)
S8JX-G050@@CD (50 W)
6 max.
44±1
14.5 max.
100±1
10 max.
Label
9.5
5 max.
8.2
92±1
47
Five, M3.5
Cover
36±1
108.6
7 (Sliding: 16.6 max.)
40±1
S8JX-G100@@D (100 W)
S8JX-G100@@CD (100 W)
S8JX-G15024D (150 W)
S8JX-G15024CD (150 W)
S8JX-G15048D (150 W)
S8JX-G15048CD (150 W)
10 max.
6 max.
50±1
100 W
150±1
150 W
14.5 max.
100·150 W
5 max.
Label
9.5
8.2
92±1
Five, M3.5
47
Cover
48±1
158.6
7 (Sliding: 16.6 max.)
50±1
21
S8JX
S8JX-G15005D (150 W)
S8JX-G15005CD (15 W)
6 max.
2-M4
14.5 max.
60±1
12 max.
5 max.
178±1
Label
10
13
9.5
8.2
92±1
47
3-M3.5
Cover
7 (Sliding: 16.6 max.)
186.6
Input voltage switch
S8JX-G15012D (150 W)
S8JX-G15012CD (150 W)
6 max.
14.5 max.
60±1
10 max.
178±1
5 max.
Label
9.5
8.2
92±1
47
5-M3.5
Cover
186.6
22
7 (Sliding: 16.6 max.)
S8JX
S8JX-G30024CD (300 W)
(17.7)
4 max.
Nine, M4 terminal screws
20 max.
10.2
167.1±1
10
8.6
92±1
46.6
4.4 (Sliding: 10 max.)
4.6 max.
4.6 max.
110±1
181.3
Note: Use a metal DIN Rail when mounting a 300-W model to a DIN Rail.
DIN Rail (Order Separately)
Mounting Rail
(Material: Aluminum)
7.3±0.15
4.5
35±0.3
15
25
10
25
25
1,000 (500) ∗
15 (5) *
25
10
27±0.15
Model
PFP-100N
PFP-50N
1
* Value in parentheses are for PFP-50N.
Mounting Rail
(Material: Aluminum)
16
4.5
35±0.3 27
24
29.2
Model
PFP-100N2
15
25
25
10
25
1,000
10
25
End Plate
15
1
1.5
10
6.2
M4 × 8
panhead
screw
1.8
1
50
1.8
35.5 35.5
Model
11.5
PFP-M
10
M4 spring
washer
1.3
4.8
Note: 1. If there is a possibility that the Unit will be subject to vibration or shock, use a steel DIN Rail. Otherwise, metallic filings may result from
aluminum abrasion.
2. If the Unit may be subjected to sliding to either side, attach an End Plate (model PFP-M) on each side of the Unit.
23
S8JX
Safety Precautions
Refer to Safety Precautions for All Power Supplies.
CAUTION
Minor electric shock, fire, or Product failure may
occasionally occur. Do not disassemble, modify, or
repair the Product to touch the interior of the
Product.
15-/35-/50-/100-/150-W Models
Standard Mounting
(Front-mounting and DIN Rail-mounting)
Standard Mounting
(Bottom-mounting)
*1
*1
Minor burns may occasionally occur. Do not touch
the Product while power is being supplied or
immediately after power is turned OFF.
*1
Fire may occasionally occur. Tighten terminal screws
to the specified torque of 1.13 N·m.
For the 5-V output terminal, tighten the terminal
screw to 1.56 N·m.
*2
*3
*1
Standard Mounting
(Horizontal Mounting)
*1
Minor injury due to electric shock may occasionally
occur. Do not touch the terminals while power is
being supplied. Always close the terminal cover after
wiring.
*1
*2
*3
300-W Model
Minor electric shock, fire, or Product failure may
occasionally occur. Do not allow any pieces of metal
or conductors or any clippings or cuttings resulting
from installation work to enter the Product.
Standard Mounting
(Front-mounting and DIN Rail-mounting)
*1
Precautions for Safe Use
Mounting
• Take adequate measures to ensure proper heat dissipation to
increase the long-term reliability of the Product.
• Be sure to allow convection in the atmosphere around devices when
mounting. Do not use in locations where the ambient temperature
exceeds the range of the derating curve. (except 600 W)
• The S8JX-@60024@ is designed to radiate heat by means of
forced air-flow. Do not cover the air holes (provided at fan mounted
side and the opposite side) to have enough air-cooling.
• The screws must not protrude beyond the following values inside
the Power Supply when screw holes provided on the chassis are
used.
15 W, 35 W, 50 W, 100 W, or 150 W: 4 mm min.
300 W or 600 W: 8 mm min.
Mounting screw tightening torque (recommended value) : 0.54 N·m.
• Rear mounting is possible using provided mounting bracket.
• When cutting out holes for mounting, make sure that cuttings do
not enter the interior of the Products.
• Improper mounting will interfere with heat dissipation and may
occasionally result in deterioration or damage of internal parts. Use
the standard mounting method only.
• The internal parts may occasionally deteriorate and be broken due
to adverse heat radiation. Do not loosen the screw on the side face
of the main body.
• When mounting two or more Power Supplies side-by-side, allow at
least 20 mm spacing between them.
• Provide a space of at least 20 mm back and forth when mounting
300-W and 600-W models as well.
• Use the metal plate as the mounting panel.
• Minor fire may occasionally occur. Set the input voltage switch to
the input voltage that is to be used (150-W, 5-V models only).
24
*2
*1
Standard Mounting
(Bottom-mounting)
*1
*3
*2
600-W Model
*1
*1
*3
*1. Convection of air
*2. 20 mm max.
*3. Use a metal plate as the mounting surface.
*2
S8JX
Wiring
DIN Rail-mounting
• Connect the ground completely. A protective earthing terminal
stipulated in safety standards is used. Electric shock or malfunction
may occur if the ground is not connected completely.
• Minor fire may possibly occur. Ensure that input and output
terminals are wired correctly.
• Do not apply more than 75 N force to the terminal block when
tightening it.
• Be sure to remove the sheet covering the Product for machining
before power-ON so that it does not interfere with heat dissipation.
• Use the following material for the wires to be connected to the
S8JX to prevent smoking or ignition caused by abnormal loads.
Recommended Wire Type
15 W, 35 W
AWG12 to AWG20 (a cross section of 0.517 to
3.309 mm2)
UL-certified temperature of at least 75°C
50W, 100W,
150 W (except
for 5 V)
AWG12 to AWG16 (a cross section of 1.309 to
3.309 mm2)
UL-certified temperature of at least 60°C or
60/75°C
Input
side
150 W
at 5 V
300 W,
600 W
AWG12 to AWG16 (a cross-section of 1.309
to 3.309 mm2)
UL-certified temperature of at least 60°C or
60/75°C
AWG8 to AWG14 (a cross-section of 2.081 to
Output 8.368 mm2)
side
UL-certified temperature of at least 60°C or
60/75°C
AWG12 to AWG20 (a cross section of 0.517 to
3.309 mm2)
UL-certified temperature of at least 60°C or
60/75°C
Installation Environment
• Do not use the Power Supply in locations subject to shocks or
vibrations. In particular, install the Power Supply as far away as
possible from contactors or other devices that are a vibration
source.
• Install the Power Supply well away from any sources of strong,
high-frequency noise and surge.
Ambient Operating and Storage Environments
• Store the Power Supply at a temperature of −25 to 65°C and a
humidity of 25% to 90%.
• The Internal parts may occasionally deteriorate or be damaged.
Do not use the Power Supply outside the derating range (i.e., the
area shown by shading A in the derating curve diagram on
page 13.)
• Use the Power Supply at a humidity of 25% to 85%.
• Do not use the Power Supply in locations subject to direct sunlight.
• Do not use locations where liquids, foreign matter, or corrosive
gases may enter the interior of the Product.
To mount the Power Supply to a DIN
Rail, pull down the rail stopper until
you hear it clicks open, hook portion
(A) of the Power Supply onto the DIN
Rail, press the Power Supply in
direction (B), and then push up the rail
stopper to lock the Power Supply in
place.
To dismount the Power Supply, pull
down portion (C) with a flat-blade
screwdriver and pull out the Power
Supply.
(C)
Track stopper
Series Operation
Two power supplies can be connected in series. The (±) voltage
output can be accomplished with two Power Supplies.
Series Operation
Correct
Output Voltage (±)
Correct
AC (L)
+V
AC (L)
+V
AC (N)
−V
AC (N)
−V
AC (L)
+V
AC (L)
+V
AC (N)
−V
AC (N)
−V
Note: 1. If the load is short-circuited, a reverse voltage will be
generated inside the Power Supply. If this occurs the Power
Supply may possibly deteriorate or be damaged. Always
connect a diode as shown in the figure. Select a diode
having the following ratings.
Type
Schottky Barrier diode
Dielectric strength (VRRM)
Twice the rated output voltage or above
Forward current (IF)
Twice the rated output current or above
2. Although Products having different specifications can be
connected in series, the current flowing through the load
must not exceed the smaller rated output current.
Parallel Operation
15-/35-/50-/100-/150-W Models
The Product is not designed for parallel operation.
Parallel Operation
Incorrect
AC (L)
AC (N)
AC (L)
Overload Protection
Charging a Battery
When connecting a battery at the load, connect an overcurrent
limiting circuit and overvoltage protection circuit.
Output Voltage Adjuster (V.ADJ)
• The output voltage adjuster (V.ADJ) may possibly be damaged if it
is turned with unnecessary force. Do not turn the adjuster with
excessive force.
• After completing output voltage adjustment, be sure that the output
capacity or output current does not exceed the rated output
capacity or rated output current.
(B)
30 mm min.
AC (N)
• Internal parts may possibly deteriorate or be damaged if a shortcircuited or overload state continues during operation.
• Internal parts may possibly deteriorate or be damaged if the Power
Supply is used for applications with frequent inrush current or
overloading at the load end. Do not use the Power Supply for such
applications.
(A)
+V
−V
+V
−V
300-/600-W Models
Parallel operation is possible under 80% of the rated value.
• To operate in parallel, set the switch to the "PARALLEL" side.
• The length and thickness of each wire connected to the load must
be the same so that there is no difference in voltage drop value
between the load and the output terminals of each Power Supply.
• It is desirable to set the same value on the voltage adjuster of each
Power Supply.
Parallel Operation
Correct
AC (L)
AC (N)
AC (L)
AC (N)
+V
−V
+V
−V
25
S8JX
In Case There Is No Output Voltage
The possible cause for no output voltage may be that the overcurrent
or overvoltage protection has operated. The internal protection may
operate if a large amount of surge voltage such as a lightening surge
occurs while turning ON the Power Supply.
In case there is no output voltage, please check the following points
before contacting us:
• Checking overcurrent protected status:
Check whether the load is in overcurrent status or is shortcircuited. Remove wires to load when checking.
• Checking overvoltage or internal protection:
Turn the power supply OFF once, and leave it OFF for at least
7 minutes. Then turn it ON again to see if this clears the condition.
Fan Replacement
600-W Model
The service life of the fan is approximately 50,000 hours (at 25°C).
The service life varies, however, depending on the ambient
temperature or other surrounding environmental conditions such as
dust. As a preventive maintenance measure, replace the fan within
approx. two years if it is used at an ambient temperature of 40°C.
Fans (S82Y-JXFAN) are available as replacements.
Switching the AC Input Voltage between 100 and 200 VAC
150-W, 5-V Models
The input voltage can be switched between 100 V and 200 V by using
the input voltage switch. Make the setting shown in the following
figure for the voltage that will be used. (The input voltage is factoryset to 200 V.)
Fan Set:
Fan (above), instruction sheet, and packing case
Replace the fan as shown in the following illustration.
"115V": 100 to 120 VAC
The input voltage switch is at the back
on the bottom of the Power Supply.
"230V": 200 to 240 VAC
300-/600-W Models
The input voltage can be switched between 100 and 200 V by shorting
or opening the input voltage selection terminals. Set the required
voltage as shown below. (The voltage is factory-set to 200 V.)
100-V input
200-V input
L
L
N
N
VOLTAGE SELECT
SHORT 100-120V
OPEN 200-230V
VOLTAGE SELECT
SHORT 100-120V
OPEN 200-230V
SHORT BAR
SHORT BAR
Short with the short bar.
Remove the short bar
and leave the terminals open.
Note: A 300-W model is shown above.
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
In the interest of product improvement, specifications are subject to change without notice.
26
Read and Understand this Catalog
Please read and understand this catalog before purchasing the product. Please consult your OMRON representative if you have
any questions or comments.
Warranty and Limitations of Liability
WARRANTY
OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year
(or other period if specified) from date of sale by OMRON.
OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT,
MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER
ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET
THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR
IMPLIED.
LIMITATIONS OF LIABILITY
OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS,
OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON
CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY.
In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted.
IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE
PRODUCTS UNLESS OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED,
INSTALLED, AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE
MODIFICATION OR REPAIR.
Application Considerations
SUITABILITY FOR USE
OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of
products in the customer's application or use of the products.
Take all necessary steps to determine the suitability of the product for the systems, machines, and equipment with which it will
be used.
Know and observe all prohibitions of use applicable to this product.
NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT
ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON
PRODUCTS ARE PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR
SYSTEM.
PROGRAMMABLE PRODUCTS
OMRON shall not be responsible for the user’s programming of a programmable product, or any consequence thereof.
Disclaimers
CHANGE IN SPECIFICATIONS
Product specifications and accessories may be changed at any time based on improvements and other reasons.
It is our practice to change model numbers when published ratings or features are changed, or when significant construction
changes are made. However, some specifications of the products may be changed without any notice. When in doubt, special
model numbers may be assigned to fix or establish key specifications for your application on your request. Please consult with
your OMRON representative at any time to confirm actual specifications of purchased products.
DIMENSIONS AND WEIGHTS
Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown.
PERFORMANCE DATA
Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a
warranty. It may represent the result of OMRON’s test conditions, and the users must correlate it to actual application
requirements. Actual performance is subject to the OMRON Warranty and Limitations of Liability.
OMRON Corporation
Industrial Automation Company
Authorized Distributor:
Tokyo, JAPAN
Contact: www.ia.omron.com
Regional Headquarters
OMRON EUROPE B.V.
Wegalaan 67-69-2132 JD Hoofddorp
The Netherlands
Tel: (31)2356-81-300/Fax: (31)2356-81-388
OMRON ELECTRONICS LLC
One Commerce Drive Schaumburg,
IL 60173-5302 U.S.A.
Tel: (1) 847-843-7900/Fax: (1) 847-843-7787
OMRON ASIA PACIFIC PTE. LTD.
No. 438A Alexandra Road # 05-05/08 (Lobby 2),
Alexandra Technopark,
Singapore 119967
Tel: (65) 6835-3011/Fax: (65) 6835-2711
OMRON (CHINA) CO., LTD.
Room 2211, Bank of China Tower,
200 Yin Cheng Zhong Road,
PuDong New Area, Shanghai, 200120, China
Tel: (86) 21-5037-2222/Fax: (86) 21-5037-2200
© OMRON Corporation 2009 All Rights Reserved.
In the interest of product improvement,
specifications are subject to change without notice.
Printed in Japan
CSM_9_1_0211
Cat. No. T041-E1-04
1110