PDF Download

■ SSR Internal Circuit Configuration Examples
Yes (See
note 1.)
Photocoupler
No
Phototriac
Circuit configuration
Photocoupler
Input
terminals
Input
circuit
Trigger
circuit
AC load
Isolation
Zero cross
circuit
Load
Zero cross
specifications function
Model
Triac
Snubber Output
circuit
terminals
G3NE
G3J
G3F
G3H
G3TA-OA
Input
circuit
Input
terminals
Phototriac
Phototriac
coupler
Trigger
circuit
Zero cross
circuit
Trigger
circuit
Trigger
circuit
Zero cross
circuit
AC/DC load
No
Photodiode
coupler
Input
terminals
Input
circuit
Trigger
circuit
Trigger
circuit
Output
transistor
Counter
electromotive
force
protective
diode
Input
terminals
Input
circuit
Output
terminals
G3HD-202SN
Varistor
Output
terminals
Photodiode
coupler
Input
terminals
Input
circuit
G3NA-4@@B
G3PH
G3PA-4@@B
G3FD, G3HD-X03
G3BD
G3TA-OD
G3NA-D
Photodiode
coupler
G3FM
Output
circuit
Photodiode
coupler
Snubber Output
circuit
terminals
Photocoupler
Drive
circuit
Photocoupler
Snubber Output
circuit
terminals
Drive
circuit
---
Snubber Output
circuit
terminals
Thyristor module
Drive
circuit
DC load
Input
circuit
G3PE-3(N) (three
phases) (See note 2.)
Snubber Output
circuit
terminals
Trigger
circuit
Input
terminals
Snubber Output
terminals
circuit
Thyristor module
Zero cross
circuit
Photocoupler
Snubber Output
circuit
terminals
Thyristor module
Phototriac coupler
Zero cross
circuit
Photocoupler
G3PA-VD
G3PE (single phase)
G3NA (DC input)
G3NE
G3PE-2(N) (three
phases) (See note 2.)
Thyristor module
Phototriac coupler
Yes (See
note 1.)
Snubber Output
circuit
terminals
Thyristor module
Phototriac coupler
Input
terminals
Triac
Thyristor module
Zero cross
circuit
Yes (See
note 1.)
Snubber Output
circuit
terminals
Trigger
circuit
Phototriac
coupler
Zero cross
circuit
Phototriac
Zero cross
circuit
Photocoupler
Input circuit
Yes (See
note 1.)
Input
terminals
Triac
Phototriac
Input circuit
Yes (See
note 1.)
Input
circuit
Trigger
circuit
Phototriac coupler
Input
terminals
G3H
G3B
G3F
G3NA (AC input)
Varistor
Output
terminals
Note: 1. The zero cross function turns ON the SSR when the AC load voltage is 0 V or close to 0 V. SSRs
with the zero cross function are effective in the following ways.
• Clicking noise when a load is turned ON is reduced.
• Effects on the power supply are reduced by suppressing inrush current with loads, such as
lamps, heaters, and motors, thereby reducing inrush current protection circuits.
Output
(load voltage)
2. For 200-V models, use a triac on the output switching elements.
Input
ON
OFF
4