Data Sheet

Solid State Relays G3@-VD
G3F/G3FD
CSM_G3F_G3FD_DS_E_5_1
International Standards for G3F Series,
Same Profile as MY Power Relays
• Shape-compatible with mechanical relays.
• Certified by UL, CSA, and VDE (model numbers with a suffix of
“-VD”).
• Socket type, same size as MY Power Relays.
• Operation indicator provided to confirm input (model numbers
with “N” before the suffix).
Refer to Safety Precautions on page 6.
Note: The socket is optional.
For the most recent information on models that have been certified for
safety standards, refer to your OMRON website.
Model Number Structure
■ Model Number Legend
G3F-@@@@@-@
1
2 3 4 5 6
7
1. Basic Model Name
G3F:
Solid State Relay
2. Rated Load Power Supply Voltage
2:
200 VAC
3. Rated Load Current
02:
2A
03:
3A
4. Terminal Type
S:
Plug-in terminals
5. Zero Cross Function
Blank:
Equipped with zero cross functions
L:
Not equipped with zero cross function
6. Operation Indicator
Blank:
Not equipped with operation indicator
N:
Equipped with operation indicator
7. Certification
VD:
Certified by UL, CSA, and VDE
G3FD-@@@@-@
1
2
3 4 5 6
7
1. Basic Model Name
G3F:
Solid State Relay
2. Load Power Supply Type
D:
DC
3. Rated Load Power Supply Voltage
X:
50 VDC
1:
100 VDC
4. Rated Load Current
02:
2A
03:
3A
5. Terminal Type
S:
Plug-in terminals
6. Operation Indicator
Blank:
Not equipped with operation indicator
N:
Equipped with operation indicator
7. Certification
VD:
Certified by UL, CSA, and VDE
1
G3F/G3FD
Ordering Information
■ List of Models
Isolation
Photocoupler
Zero cross
function
Yes
Indicator
Yes
Rated output load
Rated input voltage
Model
3 A at 100 to 240 VAC (See note 1.)
5 to 24 VDC
G3F-203SN-VD
2 A at 100 to 240 VAC (See note 1.)
100/110 VAC
G3F-202SN-VD
200/220 VAC
Phototriac coupler
No
3 A at 100 to 240 VAC (See note 1.)
5 VDC
G3F-203SLN-VD
12 VDC
24 VDC
Photocoupler

3 A at 4 to 48 VDC (See note 2.)
5 to 24 VDC
G3FD-X03SN-VD
2 A at 5 to 110 VDC
100/110 VAC
G3FD-102SN-VD
200/220 VAC
5 to 24 VDC
Photocoupler
Yes
Phototriac coupler
No
No
3 A at 100 to 240 VAC (See note 1.)
4 to 24 VDC
G3F-203S-VD
5 VDC
G3F-203SL-VD
12 VDC
24 VDC
Photocoupler

3 A at 4 to 48 VDC (See note 2.)
4 to 24 VDC
2 A at 5 to 110 VDC
G3FD-X03S-VD
G3FD-102S-VD
Note: 1. Product is labelled “240 VAC”.
2. Product is labelled “48 VDC”.
3. When ordering, specify the rated input voltage.
■ Accessories (Order Separately)
Connecting Sockets/Hold-Down Clips
Front-mounting Sockets
Back-mounting Sockets
Socket
PYF08A(-E)
PYF08M
PY08-02
PY08(QN)
Hold-down Clip
PYC-A1
PYC
PYC-P
PYC-P
PYC-P
PYC-S
2
G3F/G3FD
Specifications
■ Ratings (at an Ambient Temperature of 25C)
Input
Model
Rated voltage
Operating voltage
Impedance
Voltage level
Must operate voltage
G3F-203SN-VD
G3F-202SN-VD
5 to 24 VDC
4 to 28 VDC
Must release voltage
15 mA max. (See note.) 4 VDC max.
1 VDC min.
20 VAC min.
100/110 VAC
75 to 125 VAC
41 k20%
75 VAC max.
200/220 VAC
150 to 250 VAC
72 k20%
150 VAC max.
40 VAC min.
5 VDC
4 to 6 VDC
390 20%
4 VDC max.
1 VDC min.
12 VDC
9.6 to 14.4 VDC
900 20%
9.6 VDC max.
24 VDC
19.2 to 28.8 VDC
2 k20%
19.2 VDC max.
G3FD-X03SN-VD
5 to 24 VDC
4 to 28 VDC
1.5 k+20%/–10%
4 VDC max.
G3FD-102SN-VD
5 to 24 VDC
4 to 28 VDC
1.5 k+20%/–10%
4 VDC max.
100/110 VAC
75 to 125 VAC
41 k20%
75 VAC max.
200/220 VAC
150 to 250 VAC
72 k20%
150 VAC max.
G3F-203S-VD
4 to 24 VDC
3 to 28 VDC
15 mA max. (See note.) 3 VDC max.
G3F-203SL-VD
5 VDC
4 to 6 VDC
390 20%
12 VDC
9.6 to 14.4 VDC
900 20%
9.6 VDC max.
24 VDC
19.2 to 28.8 VDC
2 k20%
19.2 VDC max.
4 to 24 VDC
3 to 28 VDC
1.5 k+20%/–10%
3 VDC max.
G3F-203SLN-VD
G3FD-X03S-VD
20 VAC min.
40 VAC min.
1 VDC min.
4 VDC max.
G3FD-102S-VD
Note: 1. The input impedance is given for the maximum operating range. For details, refer to the Technical Guide for Solid State Relays.
2. Constant-current input circuit.
Output
Model
G3F-203SN-VD
G3F-203SLN-VD
G3F-203S-VD
G3F-203SL-VD
Rated load
voltage
100 to 240 VAC
Applicable load
Load voltage range
75 to 264 VAC
Load current
Inrush current
0.1 to 3 A at 40C
45 A (60 Hz, 1 cycle)
G3F-203SN-VD
100 to 240 VAC
75 to 264 VAC
0.1 to 2 A at 40C
45 A (60 Hz, 1 cycle)
G3FD-X03SN-VD
G3FD-X03S-VD
4 to 48 VDC
3 to 52.8 VDC
0.1 to 3 A at 40C
18 A (10 ms)
G3FD-102SN-VD
G3FD-102S-VD
5 to 110 VDC
3 to 125 VDC
0.1 to 2 A at 40C
10 A (10 ms)
3
G3F/G3FD
■ Characteristics
Item
G3F-203SN-VD
G3F-202SN-VD
G3F-203S-VD
G3F-203SLN-VD
G3F-203SL-VD
G3FD-X03SN-VD
G3FD-X03S-VD
Operate time
1/2 of load power
source cycle + 1 ms
max. (DC input)
3/2 of load power
source cycle + 1 ms
max. (AC input)
1 ms max.
Release time
1/2 of load power
source cycle + 1 ms
max. (DC input)
3/2 of load power
source cycle + 1 ms
max. (AC input)
1/2 of load power
2 ms max.
source cycle + 1 ms
max.
Output ON voltage drop 1.6 V (RMS) max.
0.5 ms max.
G3FD-102SN-VD
G3FD-102S-VD
0.5 ms max. (DC input) 0.5 ms max.
20 ms max. (AC input)
2.5 ms max. (DC input) 2.5 ms max.
20 ms max. (AC input)
1.5 V max.
Leakage current
5 mA max.
(at 100 VAC)
10 mA max.
(at 200 VAC)
2.5 mA max.
(at 100 VAC)
5 mA max.
(at 200 VAC)
5 mA max.
(at 50 VDC)
Insulation resistance
100 M min. (at 500 VDC)
Dielectric strength
2,000 VAC, 50/60 Hz for 1 min
Vibration resistance
Destruction: 10 to 55 to 10 Hz, 0.75-mm single amplitude
Shock resistance
Destruction: 1,000 m/s2
Ambient temperature
Operating: –30C to 80C (with no icing or condensation)
Storage: –30C to 100C (with no icing or condensation)
Ambient humidity
Operating: 45% to 85%
Certified standards
G3F: UL508, CSA C22.2 No. 14, EN60947-4-3
G3FD: UL508, CSA C22.2 No. 14, EN60950-1
EMC
Emission: EN55011 Group 1 Class B
Immunity: EN61000-6-2
Weight
Approx. 50 g
0.1 mA max.
(at 100 VDC)
0.1 mA max.
(at 100 VDC)
1,500 VAC, 50/60 Hz for 1 min
4
G3F/G3FD
Engineering Data
Load Current vs. Ambient Temperature Characteristics
G3F-202SN-VD
G3FD-102SN-VD/102S-VD
Load current (A)
Load current (A)
G3F-203SN-VD/203S-VD/203SLN-VD/
203SL-VD
G3FD-X03SN-VD/X03S-VD
Ambient temperature (°C)
Ambient temperature (°C)
One Cycle Surge Current: Non-repetitive
Non-repetitive (Keep the inrush current to half the rated value if it occurs repetitively.)
Inrush current (A. Peak)
Inrush current (A. Peak)
G3FD-102SN-VD/102S-VD
Inrush current (A. Peak)
G3FD-X03SN-VD/X03S-VD
G3F-203SN-VD/203S-VD/202SN-VD/
203SLN-VD/203SL-VD
10 20
Energized time (ms)
Energized time (ms)
Energized time (ms)
Dimensions
Note: All units are in millimeters unless otherwise indicated.
Terminal Arrangement/
Internal Connections
28 max.
1
4
5
8(+)
9
Load
Load
(+)
Load power
supply
12(−)
(
)
(−)
21.5 max.
13
36.5 max.
Input
14
−
42.5 max.
−
+
Input voltage
+
Note: The plus and minus symbols shown
in parentheses are for DC loads.
The load is possible to connect
either + side or - side.
5
G3F/G3FD
Safety Precautions
Refer to Safety Precautions for All Solid State Relays.
■ Precautions for Correct Use
Please observe the following precautions to prevent failure to
operate, malfunction, or undesirable effect on product performance.
Connection
The SSR for DC switching use can connect to a load regardless of
the polarity of the positive and negative output terminals.
Close Mounting of Multiple Relays
If multiple Relays are mounted side by side, be aware that the outer
wall of each SSR works as a heat sink.
The SSR casing serves to dissipate heat. Install the Relays so that
they are adequately ventilated. If poor ventilation is unavoidable,
reduce the load current by half.
Protective Terminal
When using for AC inductive loads, connect the load terminals of the
SSR to an inrush absorber (varistor).
EMC Directive Compliance
1. AC-switching models comply with EMC Directives under the
following conditions ("-VD" models only).
Less than 3 m
Load
Input
G3F-VD
Output
Varistor: 470 V, 0.6 W
Film capacitor: 1 µF, 250 VAC
Varistor
Film Capacitor
• Connect a varistor between the output terminals.
• Connect a film capacitor to the load power supply.
• The input cable must be less than 3 m.
2. DC-switching models comply with EMC Directives under the
following conditions ("-VD" models only).
Less than 10 m
Load
Input
G3FD-VD
Output
• The input cable must be less than 10 m.
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
In the interest of product improvement, specifications are subject to change without notice.
6
Terms and Conditions Agreement
Read and understand this catalog.
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you
have any questions or comments.
Warranties.
(a) Exclusive Warranty. Omron’s exclusive warranty is that the Products will be free from defects in materials and workmanship
for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron). Omron
disclaims all other warranties, express or implied.
(b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT
NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS. BUYER
ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE
PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE.
Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the
Products or otherwise of any intellectual property right. (c) Buyer Remedy. Omron’s sole obligation hereunder shall be, at
Omron’s election, to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or
replacement thereof) the non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount
equal to the purchase price of the non-complying Product; provided that in no event shall Omron be responsible for warranty,
repair, indemnity or any other claims or expenses regarding the Products unless Omron’s analysis confirms that the Products
were properly handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate
modification. Return of any Products by Buyer must be approved in writing by Omron before shipment. Omron Companies shall
not be liable for the suitability or unsuitability or the results from the use of Products in combination with any electrical or
electronic components, circuits, system assemblies or any other materials or substances or environments. Any advice,
recommendations or information given orally or in writing, are not to be construed as an amendment or addition to the above
warranty.
See http://www.omron.com/global/ or contact your Omron representative for published information.
Limitation on Liability; Etc.
OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES,
LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS,
WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY.
Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted.
Suitability of Use.
Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the
combination of the Product in the Buyer’s application or use of the Product. At Buyer’s request, Omron will provide applicable
third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself
is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine,
system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product
with respect to Buyer’s application, product or system. Buyer shall take application responsibility in all cases.
NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE
QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS,
AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE
OVERALL EQUIPMENT OR SYSTEM.
Programmable Products.
Omron Companies shall not be responsible for the user’s programming of a programmable Product, or any consequence
thereof.
Performance Data.
Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining
suitability and does not constitute a warranty. It may represent the result of Omron’s test conditions, and the user must correlate
it to actual application requirements. Actual performance is subject to the Omron’s Warranty and Limitations of Liability.
Change in Specifications.
Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our
practice to change part numbers when published ratings or features are changed, or when significant construction changes are
made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers
may be assigned to fix or establish key specifications for your application. Please consult with your Omron’s representative at
any time to confirm actual specifications of purchased Product.
Errors and Omissions.
Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is
assumed for clerical, typographical or proofreading errors or omissions.
2014.1
In the interest of product improvement, specifications are subject to change without notice.
OMRON Corporation
Industrial Automation Company
http://www.ia.omron.com/
(c)Copyright OMRON Corporation 2014 All Right Reserved.