Solid State Relays G3@-VD G3H/G3HD CSM_G3H_G3HD_DS_E_6_2 New Models with International Standards Added to G3H Series (-VD in model number). Same Profile as LY1 and LY2 Bi-power Relays • Certified by UL, CSA, and VDE (models numbers with a suffix of “-VD”). • Socket type, same size as LY Power Relays. • Operation indicator provided to confirm input (models numbers with “N” before the suffix). Refer to Safety Precautions for All Solid State Relays. Note: The socket is optional. For the most recent information on models that have been certified for safety standards, refer to your OMRON website. Model Number Structure ■ Model Number Legend G3H-@@@@@@-@ 2 3 4 5 6 7 1 1. 8 Basic Model Name G3H: Solid State Relay Rated Load Power Supply Voltage 2: 200 VAC 2. 6. 7. 3, 4. Rated Load Current 03: 5. 3A Terminal Type S: Plug-in terminals 8. Zero Cross Function Blank: Equipped with zero cross function L: Not equipped with zero cross function Operation Indicator Blank: Not equipped with operation indicator N: Equipped with operation indicator Certification VD: Certified by UL, CSA, and VDE standards G3HD-@@@@-@ 1 1. 2. 3. 4. 2 3 4 5 6 7 Basic Model Name G3H: Solid State Relay Load Power Supply Type D: DC Rated Load Power Supply Voltage X: 50 VDC Rated Load Current 03: 3A 5. 6. 7. Terminal Type S: Plug-in terminals Operation Indicator Blank: Not equipped with operation indicator N: Equipped with operation indicator Certification VD: Certified by UL, CSA, VDE 1 G3H/G3HD Ordering Information ■ List of Models Isolation Zero cross function Photocoupler Yes Phototriac coupler No Indicator Rated output load Rated input voltage 3 A at 100 to 240 VAC *1 Yes Model 5 to 24 VDC G3H-203SN-VD 5 VDC G3H-203SLN-VD 12 VDC 24 VDC Photocoupler --- Photocoupler Yes Phototriac coupler No No 3 A at 4 to 48 VDC *2 5 to 24 VDC G3HD-X03SN-VD 3 A at 100 to 240 VAC *1 4 to 24 VDC G3H-203S-VD 5 VDC G3H-203SL-VD 12 VDC 24 VDC Photocoupler --- Photovoltaic coupler --- Yes 3 A at 4 to 48 VDC *2 4 to 24 VDC G3HD-X03S-VD 2.5 A at 24 to 240 VDC *3 *4 12 to 24 VDC G3HD-202SN-VD Note: Add “-V” to the end of the model number to order a Relay for an AC inductive load with a full-wave rectifier. However, “-V” can be added only to models that do not have the zero cross function.(Example: G3H-203SL-V) *1 Product is labelled “240 VAC”. *2 Product is labelled “48 VDC”. *3 Product is labelled “240 VDC”. *4 Application is possible for a half-wave rectification load between 19.2 and 264 VAC. ■ Accessories (Order Separately) Connecting Sockets/Hold-Down Clips Front-mounting Sockets Back-mounting Sockets Socket PTF08A(-E) PT08 PT08-0 PT08QN Hold-down Clip PYC-A1 PYC-P PYC-S PYC-P PYC-P PYC-S Specifications ■ Ratings (at an Ambient Temperature of 25°C) Input Model Rated voltage Operating voltage Impedance Voltage level Must operate voltage G3H-203SN-VD 5 to 24 VDC 4 to 28 VDC 15 mA max. (See note 2.) 1 VDC min. 1 VDC min. 4 to 6 VDC 390 Ω±20% 4 VDC max. 12 VDC 9.6 to 14.4 VDC 900 Ω±20% 9.6 VDC max. 24 VDC 19.2 VDC max. G3H-203SLN-VD 5 VDC Must release voltage 4 VDC max. 19.2 to 28.8 VDC 2 kΩ±20% G3HD-X03SN-VD 5 to 24 VDC 4 to 28 VDC 1.5 kΩ +20%/–10% (See note 1.) 4 VDC max. G3H-203S-VD 4 to 24 VDC 3 to 28 VDC 15 mA max. (See note 2.) 3 VDC max. 1 VDC min. G3H-203SL-VD 5 VDC 4 to 6 VDC 390 Ω±20% 4 VDC max. 1 VDC min. G3HD-X03S-VD 12 VDC 9.6 to 14.4 VDC 900 Ω±20% 9.6 VDC max. 24 VDC 19.2 to 28.8 VDC 2 kΩ±20% 19.2 VDC max. 4 to 24 VDC 3 to 28 VDC 1.5 kΩ 9.6 to 28.8 VDC 25 mA max. (at 24 VDC) (See note 2.) G3HD-202SN-VD 12 to 24 VDC /–10% (See note 1.) 3 VDC max. +20% 9.6 VDC max. 1 VDC min. 1 VDC min. 1 VDC min. Note: 1. The input impedance is given for the maximum operating voltage. For details, refer to the Technical Guide for Solid State Relays. 2. With constant current input system. 2 G3H/G3HD Output Model Applicable load Rated load voltage G3H-203SN-VD G3H-203S-VD Load voltage range Load current Inrush current 100 to 240 VAC 75 to 264 VAC 0.1 to 3 A at 40°C 45 A 60 Hz, 1 cycle G3HD-X03SN-VD G3HD-X03S-VD 4 to 48 VDC 3 to 52.8 VDC 0.1 to 3 A at 40°C 18 A (10 ms) G3HD-202SN-VD 24 to 240 VDC 19.2 to 264 VDC 0.001 to 2.5 A at 40°C 20 A (10 ms) G3H-203SLN-VD G3H-203SL-VD ■ Characteristics Model G3H-203SN-VD/203S-VD G3H-203SLN-VD/203SL-VD G3HD-X03SN-VD/X03S-VD Operate time 1/2 cycle of load power source + 1 ms max. 1 ms max. Release time 1/2 cycle of load power source + 1 ms max. 0.5 ms max. G3HD-202SN-VD 5 ms max. 2 ms max. 10 ms max. Output ON voltage drop 1.6 V (RMS) max. 3 V max. (output ON-resistance: 1.25 Ω max.) Leakage current 5 mA max. (at 100 VAC); 2.5 mA max. (at 100 VAC); 10 mA max. (at 200 VAC) 5 mA max. (at 200 VAC) Insulation resistance 100 MΩ min. (at 500 VDC) Dielectric strength 2,000 VAC, 50/60 Hz for 1 min Vibration resistance Destruction: 10 to 55 to 10 Hz, 0.75-mm single amplitude Shock resistance Destruction: 1,000 m/s2 Ambient temperature Operating: –30°C to 80°C (with no icing) Storage: –30°C to 100°C (with no icing) Ambient humidity 45% to 85% Certified standards G3H: UL508, CSA C22.2 No. 14, EN60947-4-3 G3HD: UL508, CSA C22.2 No. 14, EN60950-1 EMC Emission: EN55011 Group 1 Class B Immunity: EN61000-6-2 Weight Approx. 50 g 5 mA max. (at 50 VDC) 0.1 mA max. (at 200 VDC) 1,500 VAC, 50/60 Hz for 1 min Engineering Data One Cycle Surge Current: Non-repetitive G3H-203SN-VD/203S-VD/203SLN-VD/ 203SL-VD G3HD-X03SN-VD/X03S-VD G3HD-202SN-VD G3H-203SN-VD/203S-VD/203SLN-VD/ G3H-203SL-VD Non-repetitive (Keep the inrush current to half the rated value if it occurs repetitively.) G3H-203SN-VD, G3H-203S-VD G3H-203SLN-VD, G3H-203SL-VD G3HD-X03SN-VD, G3HD-X03S-VD 3 2.5 G3HD-X03SN-VD/X03S-VD G3HD-202SN-VD Inrush current (A) 4 Inrush current (A, Peak) Load current (A) Load Current vs. Ambient Temperature Characteristics 50 40 30 28 26 24 22 20 G3HD-202SN-VD 18 30 16 2 G3HD-X03SN-VD G3HD-X03S-VD 14 G3HD-202SN-VD 20 1.5 12 10 8 1 6 10 4 0 −30 −20 0 20 40 60 80 100 Ambient temperature (°C) 0 10 30 50 100 200 500 1,000 5,000 Energized time (ms) 2 0 10 20 30 50 70 100 200 300 500 1,000 2,000 Energized time (ms) 3 G3H/G3HD Dimensions Note: All units are in millimeters unless otherwise indicated. (Bottom View) 28 max. 1 2 3 4(+) Load 5 (+) ( ) (−) 36.5 max. 42.5 max. 21.5 max. 6(−) Load Load power supply 7 Input − − 8 + + Input voltage Note: 1. The plus and minus symbols shown in the parentheses are for DC loads. 2. The coil has no polarity. 3. The load is possible to connect either + side or - side. Safety Precautions ■ Precautions for Correct Use EMC Directive Compliance Please observe the following precautions to prevent failure to operate, malfunction, or undesirable effect on product performance. 1. AC-switching models comply with EMC Directives under the following conditions ("-VD" models only). Less than 3 m Load Connection Input The SSR for DC switching use can connect to a load regardless of the polarity of the positive and negative output terminals. Close Mounting of Multiple Relays If multiple Relays are mounted side by side, be aware that the outer wall of each SSR works as a heat sink. The SSR casing serves to dissipate heat. Install the Relays so that they are adequately ventilated. If poor ventilation is unavoidable, reduce the load current by half. Protective Terminal No overvoltage absorption element is built in. (The G3HD-202SN has a built-in varistor.) Be sure to connect an overvoltage absorption element when using the G3H or G3HD with an inductive load. G3H-VD Output Varistor: 470 V, 0.6 W Film capacitor: 1 μF, 250 VAC Varistor Film Capacitor • Connect a varistor between the output terminals. • Connect a film capacitor to the load power supply. • The input cable must be less than 3 m. 2. DC-switching models comply with EMC Directives under the following conditions ("-VD" models only). Less than 10 m Load Input G3HD-VD Output • The input cable must be less than 10 m. ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. In the interest of product improvement, specifications are subject to change without notice. 4 Terms and Conditions Agreement Read and understand this catalog. Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranties. (a) Exclusive Warranty. Omron’s exclusive warranty is that the Products will be free from defects in materials and workmanship for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron). Omron disclaims all other warranties, express or implied. (b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS. BUYER ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the Products or otherwise of any intellectual property right. (c) Buyer Remedy. Omron’s sole obligation hereunder shall be, at Omron’s election, to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or replacement thereof) the non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount equal to the purchase price of the non-complying Product; provided that in no event shall Omron be responsible for warranty, repair, indemnity or any other claims or expenses regarding the Products unless Omron’s analysis confirms that the Products were properly handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate modification. Return of any Products by Buyer must be approved in writing by Omron before shipment. Omron Companies shall not be liable for the suitability or unsuitability or the results from the use of Products in combination with any electrical or electronic components, circuits, system assemblies or any other materials or substances or environments. Any advice, recommendations or information given orally or in writing, are not to be construed as an amendment or addition to the above warranty. See http://www.omron.com/global/ or contact your Omron representative for published information. Limitation on Liability; Etc. OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY. Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted. Suitability of Use. Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the combination of the Product in the Buyer’s application or use of the Product. At Buyer’s request, Omron will provide applicable third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine, system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product with respect to Buyer’s application, product or system. Buyer shall take application responsibility in all cases. NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. Programmable Products. Omron Companies shall not be responsible for the user’s programming of a programmable Product, or any consequence thereof. Performance Data. Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of Omron’s test conditions, and the user must correlate it to actual application requirements. Actual performance is subject to the Omron’s Warranty and Limitations of Liability. Change in Specifications. Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change part numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers may be assigned to fix or establish key specifications for your application. Please consult with your Omron’s representative at any time to confirm actual specifications of purchased Product. Errors and Omissions. Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical or proofreading errors or omissions. 2015.7 In the interest of product improvement, specifications are subject to change without notice. OMRON Corporation Industrial Automation Company http://www.ia.omron.com/ (c)Copyright OMRON Corporation 2015 All Right Reserved.