MOS FET Relays G3VM-61VY - Omron Electronic Components

MOS FET Relays
G3VM-61VY
Special SOP4-pin package with Dielectric
Strength of 3.75 kVAC
• Trigger LED forward current of 2 mA (maximum) facilitates
power saving design and prolonged battery life.
• Continuous load current of 70 mA.
• RoHS Compliant.
■ Application Examples
• Battery-driven devices
• Measurement devices and Industrial equipment
• Communication equipment and Security systems
• Amusement equipment
Note: The actual product is marked differently from the image shown
here.
■ List of Models
Package Type Contact form
SOP4
(Special)
SPST-NO
Terminals
Load voltage (peak value)
Surface-mounting 60 VAC or VDC
terminals
Model
G3VM-61VY
Number per stick
150
Number per tape
---
G3VM-61VY(TR) ---
3,000
■ Dimensions
Note: All units are in millimeters unless otherwise indicated.
G3VM-61VY
4.4±0.25
3.6±0.2
2.5±0.2
0.15
Note: The actual product is marked differently
from the image shown here.
0.4±0.1
0.5 min.
0.1±0.1
7.0±0.4
Weight: 0.1 g
2.54±0.25
■ Terminal Arrangement/Internal Connections (Top View)
G3VM-61VY
4
3
OMRON logo
Pin 1 mark
1
932
Model name
LOT.No.
2
■ Actual Mounting Pad Dimensions (Recommended Value, Top View)
G3VM-61VY
6 to 6.3
1.2
0.8
2.54
MOS FET Relays
G3VM-61VY
1
■ Absolute Maximum Ratings (Ta = 25° C)
Item
Input
Symbol
Rating
Unit
Measurement conditions
LED forward current
IF
50
mA
Repetitive peak LED
forward current
IFP
1
A
100 μs pulses, 100 pps
LED forward current
reduction rate
Δ IF/° C
-0.5
mA/° C
Ta ≥ 25° C
LED reverse voltage
VR
5
V
Connection temperature
Tj
125
°C
Output Load voltage (AC peak/DC) VOFF
60
V
Continuous load current
IO
70
ON current reduction rate
Δ ION/° C -0.7
mA/° C
Connection temperature
Tj
Note:
mA
Ta ≥ 25° C
125
°C
Dielectric strength between input and VI-O
output (See note 1.)
3,750
Vrms
AC for 1 min
Ambient Operating temperature
-40 to +85
°C
With no icing or condensation
Ta
1. The dielectric strength between the input and
output was checked by applying voltage between all pins as a group on the LED side and
all pins as a group on the light-receiving side.
Ambient Storage temperature
Tstg
-55 to +125 ° C
Soldering temperature (10 s)
---
260
With no icing or condensation
°C
10 s
■ Electrical Characteristics (Ta = 25° C)
Item
Minimum
Symbol
Typical
Maximum
Measurement
conditions
Unit
LED forward voltage
VF
1.0
1.15
1.3
V
IF = 10 mA
Reverse current
IR
---
---
10
μA
VR = 5 V
Capacity between terminals
CT
---
30
---
pF
V = 0, f = 1 MHz
IFT
---
0.6
2
mA
IO = 70 mA
RON
---
25
50
Ω
IF = 3 mA, IO = 70 mA
Current leakage when the relay is open ILEAK
---
1
1,000
nA
VOFF = 60 V
Capacity between terminals
COFF
---
10
---
pF
V = 0, f = 1MHz
CI-O
---
0.4
---
pF
f = 1 MHz, Vs = 0 V
Insulation resistance
RI-O
1,000
---
Turn-ON time
tON
---
1
Turn-OFF time
tOFF
---
0.5
Input
Trigger LED forward current
Output Maximum resistance with output ON
Capacity between I/O terminals
---
Note:
IF
MΩ
VI-O = 500 VDC,
RoH ≤ 60%
5
ms
5
ms
IF = 3 mA, RL = 200 Ω,
VDD = 10 V (See note 2.)
■ Recommended Operating Conditions
Use the G3VM under the following conditions so that the Relay will operate properly.
Item
Symbol
Minimum
Typical
Maximum
Unit
Load voltage (AC peak/DC)
VDD
---
---
48
V
Operating LED forward current
IF
---
3
25
mA
Continuous load current (AC peak/DC) IO
---
---
60
mA
Operating temperature
−20
---
65
°C
2
Ta
MOS FET Relays
G3VM-61VY
2. Turn-ON and Turn-OFF
Times
1
4
2
3
RL
VDD
VOUT
IF
VOUT
10%
t ON
90%
t OFF
■ Engineering Data
Continuous load current vs.
Ambient temperature
IO - Ta
50
40
30
20
10
0
-20
20
40
60
80
80
70
60
50
40
30
20
0
-40
100
-20
IF=3mA
40
20
40
60
80
0
-20
-40
-60
1.0
2.0
10
LED forward current IF (mA)
60
80
100
Turn ON, Turn OFF time tON, tOFF (mS)
100
1
t OFF
VDD = 10V
RL = 200Ω
IF = 3mA
-20
0
20
40
1.4
IO=70mA
2.0
1.6
1.2
0.8
0.4
0
-40
-20
60
0
20
40
60
80
100
Current leakage vs.
Ambient Temperature
I LEAK᧩T a
t ON
0.1
-40
1.3
Ambient temperature Ta (ഒ)
10
t ON
1
40
1.2
2.4
Turn ON, Turn OFF time vs.
Ambient temperature
tON, tOFF - Ta
0.1
0.01
0.1
20
0
1.1
2.8
Ambient temperature Ta (ഒ)
t OFF
VDD=10V
RL=200Ω
Ta=25°C
-20
1.0
Trigger LED forward current vs.
Ambient temperature
IFT - Ta
10
0
-40
Turn ON, Turn OFF time vs.
LED forward current
tON, tOFF - IF
1
0.9
LED forward voltage VF (V)
Current leakage ILEAK (nA)
0
1
0.1
0.8
100
20
On-state voltage VON ( V )
Turn ON, Turn OFF time tON, tOFF (mS)
20
IO = 70mA
IF = 3mA
Ta=25°C
10
0
30
80
-1.0
10
On-state resistance vs.
Ambient temperature
RON - Ta
On-state resistance RON (Ω)
Continuous load current IO (mA)
Continuous load current vs.
On-state voltage
IO - VON
-80
-2.0
Ta=25°C
Ambient temperature Taഒ
Ambient temperature Ta (ഒ)
60
100
10
Trigger LED forward current I F T (mA)
0
-40
LED forward current vs.
LED forward voltage
IF - VF
LED forward current I F (mA)
60
Continuous load current I O (mA)
LED forward current IF (mA)
LED forward current vs.
Ambient temperature
IF - Ta
80
100
10
VOFF=60V
1
0.1
0.01
0.001
-40
-20
Ambient temperature Ta (ഒ
0
20
40
60
80
100
Ambient temperature Ta (ഒ
MOS FET Relays
G3VM-61VY
3
All sales are subject to Omron Electronic Components LLC standard terms and conditions of sale, which
can be found at http://www.components.omron.com/components/web/webfiles.nsf/sales_terms.html
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
OMRON ON-LINE
OMRON ELECTRONIC
COMPONENTS LLC
Global - http://www.omron.com
USA - http://www.components.omron.com
55 E. Commerce Drive, Suite B
Schaumburg, IL 60173
847-882-2288
Cat. No. K154-E-01
MOS FET Relays
01/13
Specifications subject to change without notice
G3VM-61VY