MOS FET Relays G3VM-61VY Special SOP4-pin package with Dielectric Strength of 3.75 kVAC • Trigger LED forward current of 2 mA (maximum) facilitates power saving design and prolonged battery life. • Continuous load current of 70 mA. • RoHS Compliant. ■ Application Examples • Battery-driven devices • Measurement devices and Industrial equipment • Communication equipment and Security systems • Amusement equipment Note: The actual product is marked differently from the image shown here. ■ List of Models Package Type Contact form SOP4 (Special) SPST-NO Terminals Load voltage (peak value) Surface-mounting 60 VAC or VDC terminals Model G3VM-61VY Number per stick 150 Number per tape --- G3VM-61VY(TR) --- 3,000 ■ Dimensions Note: All units are in millimeters unless otherwise indicated. G3VM-61VY 4.4±0.25 3.6±0.2 2.5±0.2 0.15 Note: The actual product is marked differently from the image shown here. 0.4±0.1 0.5 min. 0.1±0.1 7.0±0.4 Weight: 0.1 g 2.54±0.25 ■ Terminal Arrangement/Internal Connections (Top View) G3VM-61VY 4 3 OMRON logo Pin 1 mark 1 932 Model name LOT.No. 2 ■ Actual Mounting Pad Dimensions (Recommended Value, Top View) G3VM-61VY 6 to 6.3 1.2 0.8 2.54 MOS FET Relays G3VM-61VY 1 ■ Absolute Maximum Ratings (Ta = 25° C) Item Input Symbol Rating Unit Measurement conditions LED forward current IF 50 mA Repetitive peak LED forward current IFP 1 A 100 μs pulses, 100 pps LED forward current reduction rate Δ IF/° C -0.5 mA/° C Ta ≥ 25° C LED reverse voltage VR 5 V Connection temperature Tj 125 °C Output Load voltage (AC peak/DC) VOFF 60 V Continuous load current IO 70 ON current reduction rate Δ ION/° C -0.7 mA/° C Connection temperature Tj Note: mA Ta ≥ 25° C 125 °C Dielectric strength between input and VI-O output (See note 1.) 3,750 Vrms AC for 1 min Ambient Operating temperature -40 to +85 °C With no icing or condensation Ta 1. The dielectric strength between the input and output was checked by applying voltage between all pins as a group on the LED side and all pins as a group on the light-receiving side. Ambient Storage temperature Tstg -55 to +125 ° C Soldering temperature (10 s) --- 260 With no icing or condensation °C 10 s ■ Electrical Characteristics (Ta = 25° C) Item Minimum Symbol Typical Maximum Measurement conditions Unit LED forward voltage VF 1.0 1.15 1.3 V IF = 10 mA Reverse current IR --- --- 10 μA VR = 5 V Capacity between terminals CT --- 30 --- pF V = 0, f = 1 MHz IFT --- 0.6 2 mA IO = 70 mA RON --- 25 50 Ω IF = 3 mA, IO = 70 mA Current leakage when the relay is open ILEAK --- 1 1,000 nA VOFF = 60 V Capacity between terminals COFF --- 10 --- pF V = 0, f = 1MHz CI-O --- 0.4 --- pF f = 1 MHz, Vs = 0 V Insulation resistance RI-O 1,000 --- Turn-ON time tON --- 1 Turn-OFF time tOFF --- 0.5 Input Trigger LED forward current Output Maximum resistance with output ON Capacity between I/O terminals --- Note: IF MΩ VI-O = 500 VDC, RoH ≤ 60% 5 ms 5 ms IF = 3 mA, RL = 200 Ω, VDD = 10 V (See note 2.) ■ Recommended Operating Conditions Use the G3VM under the following conditions so that the Relay will operate properly. Item Symbol Minimum Typical Maximum Unit Load voltage (AC peak/DC) VDD --- --- 48 V Operating LED forward current IF --- 3 25 mA Continuous load current (AC peak/DC) IO --- --- 60 mA Operating temperature −20 --- 65 °C 2 Ta MOS FET Relays G3VM-61VY 2. Turn-ON and Turn-OFF Times 1 4 2 3 RL VDD VOUT IF VOUT 10% t ON 90% t OFF ■ Engineering Data Continuous load current vs. Ambient temperature IO - Ta 50 40 30 20 10 0 -20 20 40 60 80 80 70 60 50 40 30 20 0 -40 100 -20 IF=3mA 40 20 40 60 80 0 -20 -40 -60 1.0 2.0 10 LED forward current IF (mA) 60 80 100 Turn ON, Turn OFF time tON, tOFF (mS) 100 1 t OFF VDD = 10V RL = 200Ω IF = 3mA -20 0 20 40 1.4 IO=70mA 2.0 1.6 1.2 0.8 0.4 0 -40 -20 60 0 20 40 60 80 100 Current leakage vs. Ambient Temperature I LEAK᧩T a t ON 0.1 -40 1.3 Ambient temperature Ta (ഒ) 10 t ON 1 40 1.2 2.4 Turn ON, Turn OFF time vs. Ambient temperature tON, tOFF - Ta 0.1 0.01 0.1 20 0 1.1 2.8 Ambient temperature Ta (ഒ) t OFF VDD=10V RL=200Ω Ta=25°C -20 1.0 Trigger LED forward current vs. Ambient temperature IFT - Ta 10 0 -40 Turn ON, Turn OFF time vs. LED forward current tON, tOFF - IF 1 0.9 LED forward voltage VF (V) Current leakage ILEAK (nA) 0 1 0.1 0.8 100 20 On-state voltage VON ( V ) Turn ON, Turn OFF time tON, tOFF (mS) 20 IO = 70mA IF = 3mA Ta=25°C 10 0 30 80 -1.0 10 On-state resistance vs. Ambient temperature RON - Ta On-state resistance RON (Ω) Continuous load current IO (mA) Continuous load current vs. On-state voltage IO - VON -80 -2.0 Ta=25°C Ambient temperature Taഒ Ambient temperature Ta (ഒ) 60 100 10 Trigger LED forward current I F T (mA) 0 -40 LED forward current vs. LED forward voltage IF - VF LED forward current I F (mA) 60 Continuous load current I O (mA) LED forward current IF (mA) LED forward current vs. Ambient temperature IF - Ta 80 100 10 VOFF=60V 1 0.1 0.01 0.001 -40 -20 Ambient temperature Ta (ഒ 0 20 40 60 80 100 Ambient temperature Ta (ഒ MOS FET Relays G3VM-61VY 3 All sales are subject to Omron Electronic Components LLC standard terms and conditions of sale, which can be found at http://www.components.omron.com/components/web/webfiles.nsf/sales_terms.html ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. OMRON ON-LINE OMRON ELECTRONIC COMPONENTS LLC Global - http://www.omron.com USA - http://www.components.omron.com 55 E. Commerce Drive, Suite B Schaumburg, IL 60173 847-882-2288 Cat. No. K154-E-01 MOS FET Relays 01/13 Specifications subject to change without notice G3VM-61VY Printed in USA