OMRON G3VM-S5

MOS FET Relays
G3VM-S5
Analog-Switching MOS FET Relay in 200-V Load
Voltage Series, SOP Package.
• Ideal replacement for the dial-pulse relay or hook relay for
modems and facsimile machines.
• Ideal for application to the line interface blocks of PBX and
telephone exchange systems.
• Can be applied to hybrid IC circuits and card-type modems
conforming to PCMCIA standards.
• Peak load voltage of 200 V.
• Approved standards: UL1577 (File No. E80555)
• RoHS Compliant.
Note: The actual product is marked differently from the image shown
here.
■ Application Examples
• PBX subscriber interfaces
• Multi-functional telephones
• Card-type modems and fax modems
• Built-in modems in personal computers
■ List of Models
Contact form
SPST-NO
Terminals
Surface-mounting
terminals
Load voltage (peak value)
200 VAC
Model
Number per stick
Number per tape
G3VM-S5
100
---
G3VM-S5(TR)
---
2,500
■ Dimensions
Note: All units are in millimeters unless otherwise indicated.
G3VM-S5
4.4±0.25
3.9±0.2
2.1 max.
0.15
Note: The actual product is marked
differently from the image
shown here.
0.4±0.1
0.1±0.1
0.6±0.3
7±0.4
2.54±0.25
Weight: 0.1 g
■ Terminal Arrangement/Internal Connections
(Top View)
■ Actual Mounting Pad Dimensions
(Recommended Value, Top View)
G3VM-S5
G3VM-S5
4
3
6 to 6.3
1.2
1
2
0.8
2.54
MOS FET Relays
G3VM-S5
157
■ Absolute Maximum Ratings (Ta = 25°C)
Item
Input
Output
Symbol
Rating
Unit
Measurement conditions
Note:
LED forward current
IF
50
mA
Repetitive peak LED
forward current
IFP
1
A
100 μs pulses, 100 pps
LED forward current
reduction rate
Δ IF/°C
−0.5
mA/°C
Ta ≥ 25°C
LED reverse voltage
VR
5
V
Connection temperature
Tj
125
°C
Load voltage (AC peak/DC) VOFF
200
V
Continuous load current
IO
150
mA
ON current reduction rate
Δ ION/°C −1.5
mA/°C
Connection temperature
Tj
Ta ≥ 25°C
125
°C
Dielectric strength between input and VI-O
output (See note 1.)
1,500
Vrms
AC for 1 min
Operating temperature
−40 to +85
°C
With no icing or condensation
With no icing or condensation
Ta
Storage temperature
Tstg
−55 to +100 °C
Soldering temperature (10 s)
---
260
1. The dielectric strength between the input and
output was checked by applying voltage between all pins as a group on the LED side and
all pins as a group on the light-receiving side.
°C
10 s
Minimum
Typical
■ Electrical Characteristics (Ta = 25°C)
Item
Input
Symbol
Maximum
Unit
Measurement
conditions
LED forward voltage
VF
1.0
1.15
1.3
V
IF = 10 mA
Reverse current
IR
---
---
10
μA
VR = 5 V
Capacity between terminals
CT
---
30
---
pF
V = 0, f = 1 MHz
---
1
3
mA
IO = 150 mA
RON
---
5
8
Ω
IF = 5 mA,
IO = 500 mA
Current leakage when the relay is open ILEAK
---
0.00045 1.0
μA
VOFF = 200 V
Capacity between terminals
COFF
---
100
---
pF
V = 0, f = 1MHz
Capacity between I/O terminals
CI-O
---
0.8
---
pF
f = 1 MHz, Vs = 0 V
Insulation resistance
RI-O
1,000
---
---
MΩ
VI-O = 500 VDC,
RoH ≤ 60%
Turn-ON time
tON
---
0.6
1.5
ms
Turn-OFF time
tOFF
---
0.1
1.0
ms
IF = 5 mA, RL = 200 Ω,
VDD = 20 V (See note 2.)
■ Recommended Operating Conditions
Use the G3VM under the following conditions so that the Relay will operate properly.
Item
Symbol
Minimum
Typical
Maximum
Unit
Load voltage (AC peak/DC)
VDD
---
150
200
V
Operating LED forward current
IF
5
7.5
25
mA
Continuous load current (AC peak/DC) IO
---
---
120
mA
Operating temperature
− 20
---
65
°C
158
Ta
MOS FET Relays
G3VM-S5
2. Turn-ON and Turn-OFF
Times
IF
IFT
Trigger LED forward current
Output Maximum resistance with output ON
Note:
1
4
2
3
RL
VDD
VOUT
IF
VOUT
10%
t ON
90%
t OFF
■ Engineering Data
LED forward current vs.
Ambient temperature
Continuous load current vs.
Ambient temperature
100
80
60
40
20
0
20
60
40
80
350
300
250
200
150
100
0
− 20
100
0
Ambient temperature Ta (ഒ)
A Connection
IF = 5mA
100
0
− 100
40
80
60
0
1
2
IF = 5mA
8
t < 1s
6
4
0
1000
300
100
tOFF
30
50
100
LED forward current IF (mA)
300 500
Turn ON, Turn OFF time tON, tOFF (μS)
tON
30
40
80
60
t < 1s
3
2
1
− 20
t ON
300
100
0
20
40
80
100
60
100
120
100
VOFF= 200V
30
10
3
t OFF
− 20
60
I LEAK - Ta
IF= 5mA
10
− 40
40
Current leakage vs.
Ambient temperature
VDD= 20V
30
20
0
Ambient temperature Ta (ഒ)
RL= 200Ω
1000
1.8
4
0
− 40
100
Turn ON, Turn OFF time vs.
Ambient temperature
3000
1.6
1.4
1.2
IO = 200mA
tON, tOFF - Ta
Ta = 25°C
VDD= 20V
RL= 200Ω
10
20
5
Ambient temperature Ta (ഒ)
tON, tOFF - IF
3000
5
1.0
0.8
IFT - Ta
IO = 200mA
0
− 20
3
Turn ON, Turn OFF time vs.
LED forward current
3
1
Trigger LED forward current vs.
Ambient temperature
10
On-state voltage VON (V)
10
1
3
LED forward voltage VF (V)
Current leakage ILEAK (nA)
− 1
10
0.1
0.6
100
2
−2
30
RON - Ta
On-state resistance RON (Ω)
Continuous load current IO (mA)
IO - VON
Turn ON, Turn OFF time tON, tOFF (μS)
20
On-state resistance vs.
Ambient temperature
Ta= 25°C
− 200
−3
Ta = 25°C
Ambient temperature Taഒ
Continuous load current vs.
On-state voltage
200
100
0.3
50
Trigger LED forward current I F T (mA)
0
− 20
IF - VF
LED forward current I F (mA)
IO - Ta
Continuous load current I O (mA)
LED forward current IF (mA)
IF - Ta
LED forward current vs.
LED forward voltage
80
100
1
− 20
Ambient temperature Ta (ഒ
0
20
40
60
80
Ambient temperature Ta (ഒ)
MOS FET Relays
G3VM-S5
159
All sales are subject to Omron Electronic Components LLC standard terms and conditions of sale, which
can be found at http://www.components.omron.com/components/web/webfiles.nsf/sales_terms.html
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
OMRON ON-LINE
OMRON ELECTRONIC
COMPONENTS LLC
Global - http://www.omron.com
USA - http://www.components.omron.com
55 E. Commerce Drive, Suite B
Schaumburg, IL 60173
847-882-2288
Cat. No. X302-E-1
MOS FET Relays
12/10
Specifications subject to change without notice
G3VM-S5
Printed in USA