DATA SHEET

FERROXCUBE
DATA SHEET
Cable shields
EMI-suppression products
Supersedes data of September 2004
2008 Sep 01
Ferroxcube
EMI-suppression products
Cable shields
CABLE SHIELDS FOR EMI-SUPPRESSION
Tubular cable shields
D
d
handbook, halfpage
L
For dimensions
see Table 1.
CBW153
Fig.1 Tubular cable shield.
Table 1
Type numbers, dimensions and parameters; see Fig.1
TYPE NUMBER
CST7.8/5.3/9.8-3S4
CST8/5.3/10-3S4
CST8.3/3.5/10-3S4
CST9.5/4.8/4.8-4S2
CST9.5/4.8/6.4-4S2
CST9.5/4.8/9.5-4S2
CST9.5/4.8/10-4S2
CST9.5/4.8/13-4S2
CST9.5/4.8/19-4S2
CST9.5/5.1/15-3S4
CST9.5/5.1/15-4S2
CST9.7/5/5.1-4S2
CST14/6.4/5.3-4S2
CST14/6.4/10-4S2
CST14/6.4/14-4S2
CST14/6.4/15-4S2
CST14/6.4/29-4S2
CST14/7.3/29-4S2
CST16/7.9/14-4S2
CST16/7.9/29-4S2
CST17/9.5/13-3S4
CST17/9.5/13-4S2
2008 Sep 01
| Z typ |(1) (Ω) at
DIMENSIONS
D
d
L
7.8 ±0.2
8 −0.4
8.3 −0.4
9.5 ±0.25
9.5 ±0.25
9.5 ±0.25
9.5 ±0.25
9.5 ±0.25
9.5 ±0.25
9.5 ±0.3
9.5 ±0.3
9.65 ±0.25
14.3 ±0.45
14.3 ±0.45
14.3 ±0.45
14.3 ±0.45
14.3 ±0.45
14.3 ±0.45
16.25 −0.75
16.25 −0.75
17.45 ±0.35
17.45 ±0.4
5.3 +0.3
5.3 +0.3
3.5 +0.3
4.75 ±0.25
4.75 ±0.25
4.75 ±0.15
4.75 ±0.15
4.75 ±0.15
4.75 ±0.15
5.1 ±0.15
5.1 ±0.15
5 ±0.2
6.35 ±0.25
6.35 ±0.25
6.35 ±0.25
6.35 ±0.25
6.35 ±0.25
7.25 ±0.15
7.9 ±0.25
7.9 ±0.25
9.53 ±0.25
9.5 ±0.25
9.8 ±0.2
10 −0.4
10 −0.6
4.8 ±0.2
6.35 ±0.35
9.5 ±0.3
10.4 ±0.25
12.7 ±0.5
19.05 ±0.7
14.5 ±0.45
14.5 ±0.45
5.05 −0.45
5.3 −0.45
10.1 ±0.4
13.8 ±0.4
15 ±0.45
28.6 ±0.75
28.6 ±0.75
14.3 ±0.35
28.6 ±0.75
12.7 ±0.5
12.7 ±0.5
1381
25 MHz
33
36(2)
70
18
23
40
53
60
100
66
66
26
35
70
90
100
170
143
70
130
55
55
100 MHz
50
50
96
35
50
70
80
95
145
110
110
43
60
105
150
170
250
215
113
213
90
88
Ferroxcube
EMI-suppression products
TYPE NUMBER
CST17/9.5/29-3S4
CST17/9.5/29-4S2
CST17/11/60-3S4
CST19/10/15-4S2
CST19/10/29-4S2
CST19/11/12-3S4
CST26/13/21-4S2
CST26/13/29-4S2
CST29/19/7.5-4S2
Cable shields
D
d
L
17.45 ±0.35
17.45 ±0.35
17.2 −1.2
19 −0.65
19 −0.65
19 ±0.4
25.9 ±0.75
25.9 ±0.75
29 ±0.75
9.53 ±0.25
9.53 ±0.25
11 ±0.5
10.15 ±0.25
10.15 ±0.25
10.6 ±0.3
12.8 ±0.25
12.8 ±0.25
19 ±0.5
28.55 ±0.75
28.55 ±0.75
60 −2.5
14.65 −0.75
28.6 ±0.75
11.5 ±0.4
21.3 ±0.5
28.6 ±0.8
7.5 ±0.25
Note
1. Minimum guaranteed impedance is Ztyp −20%.
2. At 30 MHz.
2008 Sep 01
| Ztyp |(1) (Ω) at
DIMENSIONS
1382
25 MHz
100 MHz
125
125
200
70
128
50
110
145
28
200
250
320
110
196
75
180
225
47
Ferroxcube
EMI-suppression products
Cable shields
Round cable shields (split)
A
E
handbook, halfpage
A
B
C
C
handbook, halfpage
D
B
CBW154
D
CBW155
For dimensions see Table 2.
For dimensions see Table 2.
Fig.3 Nylon case.
Fig.2 Shield (CSA) outline.
handbook, halfpage
D
C
CE
handbook, halfpage
A
B
A
B
CBW156
D
CBW157
For dimensions see Table 2.
For dimensions see Table 2.
Fig.4 Shield (CSC) outline.
2008 Sep 01
Fig.5 Nylon case.
1383
Ferroxcube
EMI-suppression products
Cable shields
General data
ITEM
SPECIFICATION
Case material polyamide (PA66), glass reinforced, flame retardant in accordance with “UL94V-0” ,
grade A82, colour black
Table 2
Type numbers, dimensions and parameters; see Figs 2 to 5
| Ztyp |(1) (Ω) at
DIMENSIONS
TYPE NUMBER
FIG.
A
B
C
D
E
25 MHz 100 MHz
Round cable shields
CSA15/7.5/29-4S2
2
CSA19/9.4/29-4S2
2
15 ±0.25
6.6 ±0.3
28.6 ±0.8
7.5 ±0.15
−
165
275
18.65 ±0.4
10.15 ±0.3
28.6 ±0.8
9.4 ±0.15
−
140
225
CSA26/13/29-4S2
2
25.9 ±0.5
13.05 ±0.3
28.6 ±0.8
12.8 ±0.25
−
155
250
CSC16/7.9/14-4S2
4
15.9 ±0.4
7.9 ±0.3
14.3 ±0.4
7.95 ±0.2
−
50
113
7.0
32.3
165
275
Round cable shields in matching nylon cases
CSA15/7.5/29-4S2-EN
Nylon case
CSA19/9.4/29-4S2-EN
Nylon case
CSA26/13/29-4S2-EN
Nylon case
CSC16/7.9/14-4S2-EN
Nylon case
2+3
17.9
9.0
3
17.9
7.0
32.3
9.2
9.0
−
−
2+3
22.1
10.2
32.3
11.7
9.0
140
225
3
22.1
10.2
32.3
11.7
9.0
−
−
2+3
29
13.4
32.5
14.8
18.0
155
250
3
29
13.4
32.5
14.8
18.0
−
−
4+5
24.7
7.6
22.8
10.2
17.8
50
5
24.7
7.6
22.8
10.2
17.8
−
Note
1. Minimum guaranteed impedance is Ztyp −20%.
2008 Sep 01
9.2
1384
113
−
Ferroxcube
EMI-suppression products
Cable shields
Flat cable shields (split)
D
D
C
C
E
B
A
C
A
D
handbook, halfpage
A B
E
B
E
MFP074
a.
b.
For dimensions see Table 3.
Fig.6 Outlines of flat cable shields (split) and accessories.
2008 Sep 01
1385
c.
Ferroxcube
EMI-suppression products
Cable shields
General data
ITEM
SPECIFICATION
Case material polyamide (PA66), glass reinforced, flame retardant in accordance with “UL94V-0” ,
grade A82, colour black
Clip material
Table 3
spring steel (0.5 mm), zinc plated
Type numbers, dimensions and parameters;
see Fig.6
TYPE NUMBER
FIG.
| Ztyp |(1) (Ω) at
DIMENSIONS
A
B
C
D
E
25 MHz 100 MHz
Flat cable shields (split)
CSU45/6.4/29-4S2
6a
45.1 ±0.75 34.4 ±0.7 28.6 ±0.7 6.35 ±0.25 0.85 ±0.2
96
225
CSU76/6.4/13-3S4
6a
76.2 ±1.5
65.3 ±1.3 12.7 ±0.4 6.35 ±0.25 0.85 ±0.2
36
110
CSU76/6.4/15-3S4
6a
76.2 ±1.5
65.3 ±1.3 15.0 ±0.6 6.35 ±0.25 0.85 ±0.2
50
159
CSU76/6.4/29-4S2
6a
76.2 ±1.5
65.3 ±1.3 28.6 ±0.8 6.35 ±0.25 0.85 ±0.2
75
215
CSU76/6.4/29-3S4
6a
76.2 ±1.5
65.3 ±1.3 28.6 ±0.8 6.35 ±0.25 0.85 ±0.2
CLI-CSU6.4
6c
16.1
70
235
11.0
12.7
11.4
8.0
−
−
96
225
Flat cable shields in matching nylon cases
CSU45/6.4/29-4S2-EN
Nylon case
CSU76/6.4/29-4S2-EN
Nylon case
6a+b
49.5
34.3
32.3
8.1
20
6b
49.5
34.3
32.3
8.1
20
−
−
6a+b
80.8
65.5
32.3
8.1
50.8
75
215
6b
80.8
65.5
32.3
8.1
50.8
−
−
Note
1. Minimum guaranteed impedance is Ztyp −20%.
2008 Sep 01
1386
Ferroxcube
EMI-suppression products
Cable shields
Flat cable shields
A
A
D
handbook, halfpage
A
handbook, halfpage
C
B
A
D
C
B E
E
CBW161
CBW162
A–A
For dimensions see Table 4.
For dimensions see Table 4.
Fig.7 CSF38/12/25 outline.
Table 4
Fig.8 CSF38/12/25-S outline.
Type numbers, dimensions and parameters;
see Figs 7 and 8
TYPE NUMBER
| Ztyp |(1) (Ω) at
DIMENSIONS
FIG.
A
B
C
D
E
25 MHz 100 MHz
Flat cable shields
CSF38/12/25-3S4
7
38.1 ±1.0 12.1 ±0.35 25.4 ±0.75 26.7 ±0.75 1.9 ±0.35
CSF38/12/25-3S4-S
8
38.5 ±0.6 12.1 ±0.4
Note
1. Minimum guaranteed impedance is Ztyp −20%.
2008 Sep 01
1387
25.4 ±0.8
26.8 ±0.8
1.9 ±0.4
110
215
98
196
Ferroxcube
EMI-suppression products
Cable shields
DATA SHEET STATUS DEFINITIONS
DATA SHEET
STATUS
PRODUCT
STATUS
DEFINITIONS
Preliminary
specification
Development
This data sheet contains preliminary data. Ferroxcube reserves the right to
make changes at any time without notice in order to improve design and
supply the best possible product.
Product specification
Production
This data sheet contains final specifications. Ferroxcube reserves the right
to make changes at any time without notice in order to improve design and
supply the best possible product.
DISCLAIMER
Life support applications  These products are not designed for use in life support appliances, devices, or systems
where malfunction of these products can reasonably be expected to result in personal injury. Ferroxcube customers
using or selling these products for use in such applications do so at their own risk and agree to fully indemnify Ferroxcube
for any damages resulting from such application.
PRODUCT STATUS DEFINITIONS
STATUS
INDICATION
DEFINITION
Prototype
These are products that have been made as development samples for the purposes of
technical evaluation only. The data for these types is provisional and is subject to
change.
Design-in
These products are recommended for new designs.
Preferred
These products are recommended for use in current designs and are available via our
sales channels.
Support
These products are not recommended for new designs and may not be available
through all of our sales channels. Customers are advised to check for availability.
2008 Sep 01
1388