TPIBU100 SERIES - Total Power International

Total Power International, Inc.
Tota
TPIBU100 SERIES
100W Open Frame Type
Industrial Power Supplies
Features:
Wide Operating Voltage 90 to 260 VAC,47 to 63 Hz
Internal EMI filter
Single Output
Active Power Factor Correction
Size: 3"x5"x1.18"
Operating temperature -20~70°C
Class I
3 year warranty
Electrical Characteristics:
Vin
Safety Approvals Input Voltage Range
100~240VAC
Operate Voltage Range
90~260VAC
fin
Input Frequency
PF
Power Factor Correction
Po
Output Power Range
See rating chart
Vo
Output Voltage Range
See rating chart
Io
Output Current Range
See rating chart
Iil
Input Current (Low Line)
Io=Full load, Vin=100VAC
2.0A (max.)
Iih
Input Current (High Line)
Io=Full load, Vin=240VAC
2.0A (max.)
Low Line Inrush Current
Io=Full load, 25°C, Cool start, Vin=115VAC
50A (max.)
High Line Inrush Current
Io=Full load, 25°C, Cool start, Vin=230VAC
100A (max.)
Efficiency
Io=Full Load, Vin=230VAC
70~85%
Ir
Eff
REG-i
Line Regulation
REG-o Load Regulation
47~63Hz
Io=Full load, Vin=240VAC
0.95~1
Io=Full Load
0.5~1%
Vin=230VAC
2~5%
OVP
Over Voltage Protection
Over Voltage Protection
112~132%
OCP
Over Current Protection
Over Current Protection
110~150%
Ttr
Time of Transient Response
Io=Full Load to Half Load, Vin=100VAC
4mS (max.)
Th
Hold-Up Time
Io=Full Load, Vin=110VAC
16mS (min.)
Ts
Start Up Time
Io=Full Load, Vin=100VAC
3S (max.)
Ripple & Noise(Peak to Peak)
Full Load, Vin=90VAC
1% (max.)
Ilk
Safety Ground Leakage Current
Vin=240VAC/60Hz
0.75mA (max.)
TC
Temperature Coefficient
All output
±0.04%/°C
Pno
No-Load Power Consumption
No load, Vin=230VAC
See rating chart
Primary to secondary
4242VDC (min.)
Primary to PE
2594VDC (min.)
Test Voltage=500VDC
50M
Vp-p
Vps
Vpg
Ris
Dielectric Withstanding Voltage
for Primary to secondary
Dielectric Withstanding Voltage
for Primary to PE
Isolation Resistance
Application:
- Industrial PC
- Electrical Test & Measurement
Instruments
- Communication equipment
- AV equipment
Safety Approvals:
CB
BAUART
GEPRUFT
TYPE
APPROVED
RoHS
2002/95/EC
COMPLIANT
UL/c-UL(UL 60950-1:2nd Edition)
TUV/GS(EN 60950-1:2nd Edition)
(min.)
Note: The Ripple & Noise which is under 3.3VDC at 2% max
Environmental
To
Operating Temperature
See derating curve
Ts
Storage Temperature
-40~85°C
Ho
Operating Humidity
0~95%
Storage Humidity
0~95%
Operating Temperature at 25°C,Calculated per MIL-HDBK-217F
0.1M Hrs (min.)
Hr
MTBF
Pd
Derate linearly from 100% load at 50°C to 50% load at 70°C
In
Total Power International,
Inc
Toll Free: 877-646-0900
www.total-power.com
Total Power International, Inc.
Tota
TPIBU100 SERIES
100W Open Frame Type
Industrial Power Supplies
Output Voltage And Current Rating Chart ( Single Output ) :
Output Voltage
Output Current
Total
Regulation
Max .
Output Power
Pno (max.)
TPIBU100-101
3 ~ 5 VDC
18.00 ~ 10.80 A
5%
54W
6W
TPIBU100-102
5 ~ 6 VDC
14.00 ~ 11.66 A
5%
70W
6W
TPIBU100-103
6 ~ 9 VDC
13.33 ~ 8.88 A
5%
80W
6W
TPIBU100-104
9 ~ 11 VDC
11.11 ~ 9.09 A
5%
100W
6W
TPIBU100-105
11 ~ 13 VDC
9.09 ~ 7.69 A
3%
100W
6W
TPIBU100-106
13 ~ 16 VDC
7.69 ~ 6.25 A
3%
100W
6W
TPIBU100-107
16 ~ 21 VDC
6.25 ~ 4.76 A
3%
100W
6W
TPIBU100-108
21 ~ 27 VDC
4.76 ~ 3.70 A
2%
100W
6W
TPIBU100-109
27 ~ 33 VDC
3.70 ~ 3.03 A
2%
100W
6W
TPIBU100-110
33 ~ 40 VDC
3.03 ~ 2.50 A
2%
100W
6W
TPIBU100-111
40 ~ 50 VDC
2.50 ~ 2.00 A
2%
100W
6W
Model Number
PIN CHART
PIN
MODEL
TPIBU100-1XX
1
2
3
4
5
6
7
8
9
10
11
12
13
OUT
OUT
OUT
OUT
OUT
OUT
RTN
RTN
RTN
RTN
RTN
RTN
N/C
Mechanical Specifications:
Note:
1. Dimensions are shown in mm.
2. Weight: 345gs approx.
3. Input connector mates with Molex housing
09-52-4054 and Molex 2478 series crimp terminal .
4. Output connector mates with Molex housing
09-52-4134 and Molex 2478 series crimp terminal.
Derating Cruve :
1. Operating Temperature: -20 to 70°C
2. Derate linearly from 100% load at 50°C to 50%
load at 70°C
120%
Output Watts (%)
100%
80%
60%
40%
20%
0%
-20
0
10
20
30
40
50
60
70
80
Temperature (deg c)
Total Power In
International, Inc
Toll Free: 877-646-0900
www.total-power.com