MBU80 SERIES 80W Open Frame Switching Power Supplies For Medical Equipment. Description: The MBU80 series of compact, open frame constructed, AC/DC switching mode power supplies provide 80 Watts of continuous output power.They are suited for use in hospital instrument and many other applications. All models meet FCC Part-18 class B and CISPR-11 EN55011 class B emission Limits and are designed to comply with UL/c-UL(UL 60601-1:2ndEdition) ,TUV/T-mark(EN 60601-1:2ndEdition) and new CE requirements. All units are 100% burned in and tested. Features: Wide Operating Voltage 90 to 260 VAC,47 to 63 Hz Internal EMI filter Single Output Input connector mates with Molex housing 09-50-3031 and Molex 2478 series crimp terminal Output connector mates with screw terminal (Terminal Block)(16-22AWG) or Molex housing 09-50-3121and Molex 2478 series crimp terminal Input Surge Current, Over Voltage and Over Load protection Output Voltage Protection(Crowbar Design) Active Power Factor Correction Size: 3"x5"x1.1" Class I 3 year warranty Safety Approvals : EN 60601-1 IEC 60601-1 Electrical Characteristics: Sym. Parameter fin PF Po Vo Io Iil Iih Safety Approvals Input Voltage Range Operate Voltage Range Input Frequency Power Factor Correction Output Power Range Output Voltage Range Output Current Range Input Current (Low Line) Input Current (High Line) I rl Low Line Inrush Current Vin I rh Eff REG-i REG -o OVP OCP Ttr Thold Ts Vp-p Ilk TC High Line Inrush Current Efficiency Line Regulation Load Regulation Over Voltage Protection Over Current Protection Time of Transient Response Hold-Up Time Start Up Time Ripple & Noise (Peak to Peak) Safety Ground Leakage Current Temperature Coefficient Test Conditions Min. Typ. Max. Unit 240 100 Io=Full load, Vin=100~240VAC Vin=90 to 260 VAC Io=Full load, Io=Full load, Io=Full load, Vin=115VAC Io=Full load, Vin=230VAC Io=Full load, Io=Full load Vin=230VAC Vin=100VAC Vin=240VAC 25 C,Cool start, 90 260 47 63 0.95 0.97 1.0 80 0 See rating Chart See rating Chart 1.2 0.4 VAC Hz 15 18 A 30 34 A 80 0.5 3 85 1 7 132 150 4 % % % % % mS mS S % mA %/ C 25 C,Cool start, Vin=230VAC VAC 70 112 110 Io=Full load to Half Load, Vin=100VAC 16 Io=Full load, Vin=110VAC Io=Full load, Vin=100VAC 1 2 0.3 Full load, Vin=90VAC 0.5 1 Io=Full load, Vin=240VAC 0.1 All output -0.04 0.04 W V A A A Environmental : Sym. Toper Parameter T e s t Conditions Operating Temperature Min. Typ. Max. Unit 50 70 C Storage Temperature -40 85 C Operating Humidity 0 95 % 0 75 Tstg Ho Hr Storage Humidity MTBF Operating Temperature at 25 C, Calculated per MIL-HDBK-217F Pd Derate linearly from 100% load at 50 C to 50% load at 70 C 0 0.1M % Hrs MBU80 SERIES 80W Open Frame Switching Power Supplies For Medical Equipment. Safety Specifications: Sym. Parameter Min. Typ. Max. Unit Primary to secondary 5656 VDC Primary to ground 2828 VDC 50 B B M CLASS CLASS T e s t Conditions Dielectric Withstanding Voltage for Primary to secondary Dielectric Withstanding Voltage Vpg for Primary to Ground Ris Isolation Resistance CISPR EMI requirements for CISPR-11 FCC EMI requirements for FCC PART-18 Vps Test Voltage=500VDC Vin=220VAC Vin=110VAC Output Voltage And Current Rating Chart (Single Output) : Model Number Ou tpu t Voltage Outpu t Current Total Regulation Maximum Output Power MBU80-102 5 VDC 14.00 A 5% 70W MBU80-103 7 VDC 11.43 A 5% 80W MBU80-104 9 VDC 8.89 A 4% 80W MBU80-105 12 VDC 6.66 A 3% 80W MBU80-106 15 VDC 5.33 A 3% 80W MBU80-107 18 VDC 4.44 A 3% 80W MBU80-108 24 VDC 3.33 A 2% 80W MBU80-109 30 VDC 2.66 A 2% 80W MBU80-110 36 VDC 2.22 A 2% 80W PIN CHART PIN MODEL 1 MBU80-1XX-12PIN RTN 2 3 4 5 6 7 8 9 10 11 12 PIN MODEL 1 2 3 4 5 6 RTN RTN RTN RTN RTN Vout Vout Vout Vout Vout Vout MBU80-1XX-6PIN RTN RTN RTN Vout Vout Vout Mechanical Specifications : Note: 1. Dimensions are shown in inches or mm. 2. Weight: 300gs approx. 3. Input connector mates with Molex housing 09-50-3031 and Molex 2478 series crimp terminal. 4. Output connector mates with screw terminal (Terminal Block)(16-22AWG) or Molex housing 09-50-3121 and Molex 2478 series crimp terminal (Optional)