MBU30 SERIES 30W Open Frame Switching Power Supplies For Medical Equipment. Description: The MBU30 series of compact, open frame constructed, AC/DC switching mode power supplies provide 30 Watts of continuous output power .They are suited for use in hospital instrument and many other applications. All models meet FCC Part-18 class B and CISPR-11 EN55011 class B emission Limits and are designed to comply with UL/c-UL(UL 60601-1:2ndEdition) ,TUV/T-mark(EN 60601-1:2ndEdition) and new CE requirements. All units are 100% burned in and tested. Features: Wide Operating Voltage 90 to 264 VAC,47 to 63 Hz Internal EMI filter Single Output Input connector mates with Molex housing 09-50-3031 and Molex 2478 series crimp terminal Output connector mates with Molex housing 09-50-3061 and Molex 2478 series crimp terminal Input Surge Current, Over Voltage and Over Load protection Output Voltage Protection(Crowbar Design) Size: 2"x4" Class I 3 year warranty Safety Approvals : EN 60601-1 IEC 60601-1 Electrical Characteristics: Sym. Parameter Vin Safety Approvals Input Voltage Range fin Po Vo Io Iil Iih Operate Voltage Range Input Frequency Output Power Range Output Voltage Range Output Current Range Input Current (Low Line) Input Current (High Line) I rl Low Line Inrush Current I rh High Line Inrush Current Eff REG-i REG -o OVP OCP Ttr Thold Ts Vp-p Ilk TC Efficiency Line Regulation Load Regulation Over Voltage Protection Over Current Protection Time of Transient Response Hold-Up Time Start Up Time Ripple & Noise (Peak to Peak) Safety Ground Leakage Current Temperature Coefficient Test Conditions Min. Typ. Max. Unit 100 Vin=90 to 264 VAC Io=Full load, Io=Full load, Io=Full load, Vin=115VAC Io=Full load, Vin=230VAC Io=Full load, Io=Full load Vin=230VAC Vin=115VAC Vin=230VAC 25 C,Cool start, VAC 264 90 47 63 30 0 See rating Chart See rating Chart 0.7 0.3 0.5 VAC Hz W V A A A 15 18 A 21 25 A 80 0.5 3 85 1 7 132 150 4 % % % % % mS mS S % mA %/ C 25 C,Cool start, Vin=230VAC 240 70 112 110 Io=Full load to Half Load, Vin=100VAC 10 12 Io=Full load, Vin=110VAC Io=Full load, Vin=100VAC 1 2 0.3 Full load, Vin=90VAC 0.5 1 Io=Full load, Vin=240VAC 0.1 0.3 All output -0.04 0.04 Environmental : Sym. Parameter T e s t Conditions Min. Typ. Max. Unit 50 70 C Toper Operating Temperature Tstg Storage Temperature -40 85 C Ho Operating Humidity 0 95 % Hr Storage Humidity 0 75 % MTBF Operating Temperature at 25 C, Calculated per MIL-HDBK-217F Pd Derate linearly from 100% load at 50 C to 50% load at 70 C 0 0.1M Hrs MBU30 SERIES 30W Open Frame Switching Power Supplies For Medical Equipment. Safety Specifications: Sym. Parameter Min. Typ. Max. Unit Primary to secondary 5656 VDC Primary to ground 2828 VDC 50 B B M CLASS CLASS 1 T e s t Conditions ○ Dielectric Withstanding Voltage Vps for Primary to secondary Dielectric Withstanding Voltage Vpg for Primary to Ground Ris Isolation Resistance CISPR EMI requirements for CISPR-11 FCC EMI requirements for FCC PART-18 Test Voltage=500VDC Vin=220VAC Vin=110VAC 1 Recommend to be used on the metal chassis. ○ Output Voltage And Current Rating Chart (Single Output) : Model Number Output Voltage Output Current Total Regulation Maximum Output Power MBU30-102 5 VDC 6.00 A 5% 30W MBU30-103 7 VDC 4.28 A 5% 30W MBU30-104 9 VDC 3.33 A 5% 30W MBU30-105 12 VDC 2.50 A 5% 30W MBU30-106 15 VDC 2.00 A 5% 30W MBU30-107 18 VDC 1.66 A 5% 30W MBU30-108 24 VDC 1.25 A 5% 30W MBU30-109 30 VDC 1.00 A 5% 30W MBU30-110 36 VDC 0.83 A 3% 30W Mechanical Specifications : PIN CHART PIN 1 2 3 4 5 6 MODEL MBU30-1XX RTN RTN RTN Vout Vout Vout Note: 1. Dimensions are shown in inches or mm. 2. Weight: 200gs approx. 3. Input connector mates with Molex housing 09-50-3031 and Molex 2478 series crimp terminal. 4. Output connector mates with Molex housing 09-50-3061 and Molex 2478 series crimp terminal.