MBU150 SERIES 150W Open Frame Switching Power Supplies For Medical Equipment. Description: The MBU150 series of compact, open frame constructed, AC/DC switching mode power supplies provide 150 Watts of continuous output power.They are suited for use in hospital instrument and many other applications. All models meet FCC Part-18 class B and CISPR-11 EN55011 class B emission Limits and are designed to comply with UL/c-UL(UL 60601-1:2ndEdition) and new CE requirements. All units are 100% burned in and tested. Features: Wide Input Voltage 100 to 240 VAC,47 to 63 Hz Internal EMI filter Single Output Input connector mates with Molex housing 09-50-3051 and Molex 2478 series crimp terminal Output connector mates with Molex housing 09-50-3081 and Molex 2478 series crimp terminal Input Surge Current, Over Voltage and Over Load protection Output Voltage Protection(Crowbar Design) Active Power Factor Correction Size: 3"x5"x1.44” Class I 3 year warranty Safety Approvals : CB Electrical Characteristics: Sym. Parameter Vin fin PF Po Vo Io Iil Iih Input Voltage Input Frequency Power Factor Correction Output Power Range Output Voltage Range Output Current Range Input Current (Low Line) Input Current (High Line) I rl Low Line Inrush Current I rh High Line Inrush Current Eff REG-i REG -o OVP OCP Ttr Thold Ts Vp-p Ilk TC Efficiency Line Regulation Load Regulation Over Voltage Protection Over Current Protection Time of Transient Response Hold-Up Time Start Up Time Ripple & Noise (Peak to Peak) Safety Ground Leakage Current Temperature Coefficient Test Conditions Operating Voltage Io=Full load, Vin=100~240VAC Vin=100 to 240 VAC Io=Full load, Io=Full load, Io=Full load, Vin=115VAC Io=Full load, Vin=230VAC Io=Full load, Io=Full load Vin=230VAC Vin=115VAC Vin=230VAC 25 C,Cool start, IEC 60601-1 Min. Typ. Max. Unit 240 100 47 63 0.95 0.97 1.0 150 0 See rating Chart See rating Chart 2 1.2 VAC Hz 28 31 A 57 63 A 85 0.5 3 87 1 5 132 150 4 % % % % % mS mS S % mA %/ C 25 C,Cool start, Vin=230VAC EN 60601-1 82 112 110 Io=Full load to Half Load, Vin=100VAC 20 Io=Full load, Vin=110VAC Io=Full load, Vin=100VAC 2 Full load, Vin=90VAC 0.5 1 Io=Full load, Vin=240VAC 0.075 0.1 All output -0.04 0.04 W V A A A Environmental : Sym. Parameter T e s t Conditions Min. Typ. Max. Unit 50 C Toper Operating Temperature Tstg Storage Temperature -40 85 C Ho Operating Humidity 0 95 % Hr Storage Humidity 0 75 % MTBF Operating Temperature at 25 C, Calculated per MIL-HDBK-217F Pd Derate linearly from 100% load at 50 C to 50% load at 70 C 0 0.1M 70 Hrs MBU150 SERIES 150W Open Frame Switching Power Supplies For Medical Equipment. Safety Specifications: Sym. Parameter Min. Typ. Max. Unit Primary to secondary 5656 VDC Primary to ground 2828 VDC 50 B B M CLASS CLASS T e s t Conditions Dielectric Withstanding Voltage Vps for Primary to secondary Dielectric Withstanding Voltage Vpg for Primary to Ground Ris Isolation Resistance CISPR EMI requirements for CISPR-11 FCC EMI requirements for FCC PART-18 Test Voltage=500VDC Vin=220VAC Vin=110VAC Output Voltage And Current Rating Chart (Single Output) : Model Number Ou tpu t Voltage Outpu t Current Total Regulation Maximum Output Power MBU150-105 12 VDC 12.50 A 5% 150W MBU150-108 24 VDC 6.25 A 3% 150W PIN CHART Mechanical Specifications : PIN MODEL 1 2 3 4 5 6 7 8 MBU150-1XX Vout Vout Vout Vout RTN RTN RTN RTN LED 1 L P2 8 N G P1 Note: 1. Dimensions are shown in inches or mm. 2. Weight: 420gs approx. 3. Input connector mates with Molex housing 09-50-3051 and Molex 2478 series crimp terminal. 4. Output connector mates with Molex housing 09-50-3081 and Molex 2478 series crimp terminal