HBU60 SERIES 60W Open frame type medical power supplies for health care applications Description: The HBU60 series of compact, open frame constructed, AC/DC switching mode power supplies provide 60 Watts of continuous output power .They are suited for use in health care applications. All models meet FCC Part-18 class B and CISPR-11 EN55011 class B emission limits and are designed to comply with UL/c-UL(UL 60601-1:2ndEdition) ,TUV/T-mark(EN 60601-1:2ndEdition) and new CE requirements. All units are 100% burned in and tested. Features: Wide Operating voltage 90 to 264 VAC,47 to 63 Hz Single output Input connector mates with molex housing 09-50-3031/35977-0300 and molex 2478/ 35922 series crimp terminal. Output connector mates with molex housing 09-50-3061/35977-0600 and molex 2478/ 35922 series crimp terminal. Input surge current, over voltage and over load protection Size: 2"x4”x1” Class I 2 year warranty Safety approvals : CB Electrical characteristics: Sym. Parameter fin Po Vo Io Iil Iih Safety Approvals Input Voltage Range Operate Voltage Range Input Frequency Output Power Range Output Voltage Range Output Current Range Input Current (Low Line) Input Current (High Line) I rl Low Line Inrush Current Vin I rh Eff REG-i REG -o OVP OCP Ttr Thold Ts Vp-p Ilk TC High Line Inrush Current Efficiency Line Regulation Load Regulation Over Voltage Protection Over Current Protection Time of Transient Response Hold-Up Time Start Up Time Ripple & Noise (Peak to Peak) Safety Ground Leakage Current Temperature Coefficient Test Conditions Io=Full load, Io=Full load, Io=Full load, Vin=115VAC Io=Full load, Vin=230VAC Io=Full load, Io=Full load Vin=230VAC Vin=115VAC Vin=230VAC 25 C,Cool start, IEC 60601-1 Min. Typ. Max. Unit 100 Vin=90 to 264 VAC EN 60601-1 240 264 90 47 63 60 0 See rating Chart See rating Chart 1.62 0.72 26 30 25 C,Cool start, 43 47 Vin=230VAC 85 VAC VAC Hz W V A A A A A Io=Full load to Half Load, Vin=100VAC 12 16 Io=Full load, Vin=110VAC Io=Full load, Vin=100VAC 0.3 1 2 Full load, Vin=90VAC 1 Io=Full load, Vin=240VAC 0.1 0.3 All output -0.04 0.04 % % % % % mS mS S % mA %/ C Min. Typ. Max. Unit 40 70 C 1 5 132 150 4 112 110 Environmental : Sym. Parameter T e s t Conditions Toper Operating Temperature Tstg Storage Temperature -40 85 C Ho Operating Humidity 0 95 % Hr Storage Humidity 0 75 % MTBF Operating Temperature at 25 C, Calculated per MIL-HDBK-217F Pd Derate linearly from 100% load at 40 C to 50% load at 70 C 0 0.1M Hrs HBU60 SERIES 60W Open frame type medical power supplies for health care applications Safety specifications: Sym. Parameter Dielectric Withstanding Voltage Vps for Primary to secondary Dielectric Voltage Vpg for Primary Withstanding to Ground Ris Isolation Resistance CISPR EMI requirements for CISPR-11 FCC EMI requirements for FCC PART-18 Min. Typ. Max. Unit Primary to secondary 5656 VDC Primary to ground 2828 VDC 50 B B M CLASS CLASS T e s t Conditions Test Voltage=500VDC Vin=220VAC Vin=110VAC Output voltage and current rating chart (Single output) : Model Number Output Voltage Output Current Total Regulation Maximum Output Power HBU60-105 012 ~ 13 VDC 5.00 ~ 4.61 A 5% 60W HBU60-106 013 ~ 16 VDC 4.61 ~ 3.75 A 5% 60W HBU60-107 16 ~ 21 VDC 3.75 ~ 2.85 A 5% 60W HBU60-108 21 ~ 27 VDC 2.85 ~ 2.22 A 3% 60W HBU60-109 27 ~ 33 VDC 2.22 ~ 1.81 A 3% 60W HBU60-110 33 ~ 40 VDC 1.81 ~ 1.50 A 3% 60W Mechanical specifications : Pin Char t PIN MODEL HBU60-1XX 1 2 3 4 5 6 OUT OUT OUT RTN RTN RTN Note: 1. Dimensions are shown in inches or mm. 2. Weight: 140gs approx. 3. Input connector mates with Molex housing 09-50-3031/35977-0300 and Molex 2478/ 35922 series crimp terminal. 4. Output connector mates with Molex housing 09-50-3061/35977-0600 and Molex 2478/ 35922 series crimp terminal.