Authorized Distributor: Total Power International, Inc. Toll Free: 877-646-0900(US) PH# (978) 453-7272 www.total-power.com MSP-100 100W Single Output Medical Type series ■ Features : ‧Universal AC input / Full range ‧Built-in active PFC function ‧High efficiency up to 90% ‧Withstand 300VAC surge input for 5 seconds ‧Protections: Short circuit / Overload / Over voltage ‧Protections: Over temperature (optional) ‧Cooling by free air convection ‧1U low profile 38mm ‧Medical safety approved (MOOP level) ‧Built-in remote ON-OFF control ‧No load power consumption<0.5W (Note.6) ‧All using 105℃ long life electrolytic capacitors ‧5 years warranty SPECIFICATION MODEL OUTPUT MSP-100-3.3 MSP-100-5 MSP-100-7.5 MSP-100-12 MSP-100-15 MSP-100-24 MSP-100-36 DC VOLTAGE 3.3V 5V 7.5V 12V 15V 24V 36V 48V RATED CURRENT 20A 17A 13.5A 8.5A 7A 4.5A 2.9A 2.2A CURRENT RANGE 0 ~ 20A 0 ~ 17A 0 ~ 13.5A 0 ~ 8.5A 0 ~ 7A 0 ~ 4.5A 0 ~ 2.9A 0 ~ 2.2A RATED POWER 66W 85W 101.3W 102W 105W 108W 104.4W 105.6W RIPPLE & NOISE (max.) Note.2 80mVp-p 80mVp-p 100mVp-p 120mVp-p 150mVp-p 150mVp-p 200mVp-p 240mVp-p VOLTAGE ADJ. RANGE 4.75 ~ 5.8V +2.5,-3.5% 7.1 ~ 9V ±2.5% 11.4 ~ 13.8V ±1.5% 14.25 ~ 18V ±1.5% 22.8 ~ 28.8V ±1.5% 34.2 ~ 39.6V ±1.5% 45.6 ~ 55.2V ±1.5% 3.1 ~ 3.8V VOLTAGE TOLERANCE Note.3 +2.5,-3.5% LINE REGULATION ±0.5% ±0.5% ±0.5% ±0.3% ±0.3% ±0.2% ±0.2% ±0.2% LOAD REGULATION ±2.0% ±2.0% ±1.5% ±0.8% ±0.8% ±0.5% ±0.5% ±0.5% SETUP, RISE TIME 2500ms, 100ms/230VAC HOLD UP TIME (Typ.) 50ms/230VAC 88% 88.5% 89% 90% PF>0.95/230VAC EFFICIENCY (Typ.) 78% AC CURRENT (Typ.) INRUSH CURRENT (Typ.) 1.2A/115VAC 35A/115VAC FUNCTION PF>0.98/115VAC at full load 83% 84% 87.5% 0.6A/230VAC 65A/230VAC Note.7 Earth leakage current < 300μA/264VAC , Touch leakage current < 100μA/264VAC OVERLOAD PROTECTION 120 ~ 370VDC POWER FACTOR (Typ.) LEAKAGE CURRENT 2500ms, 100ms/115VAC at full load 20ms/115VAC at full load Note.5 85 ~ 264VAC VOLTAGE RANGE FREQUENCY RANGE 47 ~ 63Hz INPUT MSP-100-48 OVER VOLTAGE OVER TEMPERATURE REMOTE CONTROL 105 ~ 135% rated output power Protection type : Constant current limiting for Vo=50 ~ 100% of rated voltage, recovers automatically after fault condition is removed 6 ~ 7V 9.4 ~ 10.9V 14.4 ~ 16.8V 18.8 ~ 21.8V 30 ~ 34.8V 41.4 ~ 48.6V 57.6 ~ 67.2V 3.96 ~ 4.62V Protection type : Shut down o/p voltage, re-power on to recover Shut down o/p voltage, recovers automatically after temperature goes down RC+/RC- : 0 ~ 0.8V= power on ; 4 ~ 10V = power off -40 ~ +60℃ (Refer to "Derating Curve") WORKING TEMP. 20 ~ 90% RH non-condensing WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY -40 ~ +85℃ , 10 ~ 95% RH ±0.04%/℃ (0 ~ 50℃) TEMP. COEFFICIENT VIBRATION SAFETY STANDARDS SAFETY & WITHSTAND VOLTAGE ISOLATION RESISTANCE EMC (Note 4) EMC EMISSION EMC IMMUNITY OTHERS NOTE 10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes ANSI/AAMI ES60601-1, IEC60601-1 approved I/P-O/P:4KVAC I/P-FG:2KVAC Compliance to EN61000-4-2,3,4,5,6,8,11, EN60601-1-2 MIL-HDBK-217F (25℃) MTBF 295.7K hrs min. DIMENSION 159*97*38mm (L*W*H) PACKING 0.38Kg; 24pcs/10.1Kg/0.76CUFT 1. 2. 3. 4. 5. 6. 7. 8. O/P-FG:0.5KVAC I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃ / 70% RH Compliance to EN55011 (CISPR11) Class B, EN61000-3-2,-3 All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. Tolerance : includes set up tolerance, line regulation and load regulation. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on http://www.meanwell.com) Derating may be needed under low input voltages. Please check the derating curve for more details. No load power consumption<0.5W when RC+ & RC- (CN100 pin1,2) 0 ~ 8V or short. Touch current was measured from primary input to DC output. When the input voltage is less than 40VAC, the SPS may exhibit degradation of performance. The final product manufacturers must re-confirm this deviation that does not affect basic safety or essential performance. File Name:MSP-100-SPEC 2014-02-12 Authorized Distributor: Total Power International, Inc. Toll Free: 877-646-0900(US) PH# (978) 453-7272 www.total-power.com MSP-100 100W Single Output Medical Type Mechanical Specification Case No.901I series Unit:mm 152.5 1 2 3 4 5 6 7 CN100 SVR1 4.5 Terminal Pin No. Assignment Pin No. 1 2 3 Assignment AC/L AC/N 24 Pin No. Assignment 4,5 DC OUTPUT -V 6,7 DC OUTPUT +V 78 159 6.5 150 FG 10 max. Remote ON/OFF (CN100) : JST B-XH or equivalent Pin No. 1 2 Assignment RCRC+ Mating Housing Terminal JST XHP or equivalent JST SXH-001T or equivalent 6-M3(Both Sides) L=6 22 117 Block Diagram ACTIVE INRUSH CURRENT LIMITING EMI FILTER I/P RECTIFIERS & PFC POWER SWITCHING O.T.P. O.L.P. RECTIFIERS & FILTER DETECTION CIRCUIT FG PFC CONTROL O.V.P. PWM CONTROL Derating Curve +V -V RC+ REMOTE CONTROL RC- Output Derating VS Input Voltage 100 100 90 80 80 70 60 60 40 50 20 -40 40 0 10 20 30 40 50 AMBIENT TEMPERATURE (℃) 60 70 (HORIZONTAL) 85 100 125 135 155 264 INPUT VOLTAGE (V) 60Hz File Name:MSP-100-SPEC 2014-02-12