Mini-Com Water Resistant Faceplate Part Number: CFPWR4** INSTALLATION INSTRUCTIONS © Panduit Corp. 2011 PN282D cover gasket #6 - 32 x 1" combination head screws (2 included) base gasket #6 - 32 x 1.25" combination head screws (2 included) faceplate (cover / base) back seal gasket #6 - 32 x 1.25" hexagon button head screws (2 included) CFPWR4** Module Installation 1. 2. Place 1/8" back seal gasket on the back of the faceplate as shown above. 3. Align notch on module with tab on faceplate. 4. Rotate module downward. Snap into place. Repeat for all openings. For Technical Support: www.panduit.com/resources/install_maintain.asp Page 1 of 2 INSTALLATION INSTRUCTIONS © Panduit Corp. 2011 PN282D Faceplate Installation 5. 6. A B After modules have been installed, align #6-32 x 1" combination head screws with holes as shown above to mount faceplate. When inserting screws make sure back seal gasket is properly aligned behind the base. Press the cover gasket (A) into the cover and the base gasket (B) into the base as indicated above. 8. 7. channel Insert compatible plugs into modules. Align cables 1 per channel on the base gasket as shown above. After cables have been aligned, close cover and secure with #6-32 x 1.25" combination head screws or #6-32 x 1.25" hexagon button head screws at a max torque of 14 in-lbs. For hexagon button head screws use a 5/64" hex key tool. E-mail: [email protected] For Instructions in Local Languages and Technical Support: www.panduit.com/resources/install_maintain.asp www.panduit.com Page 2 of 2 Fax: (708) 444-6993