Data Sheets - Skyworks Solutions, Inc.

PRELIMINARY DATA SHEET
SKY13488: 0.4-3.8 GHz SP12T MIPI® Antenna Switch Module
Applications
• 2G/3G/4G multimode cellular handsets (LTE, UMTS, CDMA2000,
EDGE, GSM, TDD-LTE, TD-SCDMA)
• Embedded data cards
Features
• Dedicated Band 7 TRX ports: 0.7 dB insertion loss @ 2.7 GHz
• High isolation and linearity
• Broadband frequency range: 0.4 to 3.8 GHz
• Ten linear TRX ports: B13 2fo <–81 dBm
• Integrated low and high band GSM harmonic filters
• Integrated MIPI interface
• External MIPI select pin to enable multiple trigger controls
• Small MCM (20-pin, 2.5 x 2.5 x 0.8 mm) package (MSL3,
260 °C per JEDEC J-STD-020)
Figure 1. SKY13488 Block Diagram
Description
The SKY13488 is a Single Pole, Twelve Throw (SP12T) antenna
switch with an integrated Mobile Industry Processor Interface
(MIPI) controller. Using an advanced switching technology, the
SKY13488 maintains low insertion and high isolation, which
makes it an ideal choice for UMTS, CDMA2000, EDGE, GSM, and
LTE applications.
The design features two dedicated GSM transmit ports and three
dedicated ultra low-loss TRX ports. The switch also has an
excellent triple beat ratio and 2nd/3rd Order Intermodulation
Distortion (IMD2/IMD3) performance.
Switching is controlled by the MIPI decoder. There is an external
MIPI select pin that enables how the switch responds to power
mode triggers. When this pin is grounded, the switch responds to
any of the power mode triggers. When this pin is left open, the
switch responds to individual power mode triggers.
No external DC blocking capacitors are required on the RF paths
as long as no DC voltage is applied.
Figure 2. SKY13488 Pinout – 20-Pin MCM
(Top View)
The SKY13488 is manufactured in a compact,
2.5 x 2.5 x 0.8 mm, 22-pin surface mount Multi-Chip Module
(MCM) package.
A functional block diagram is shown in Figure 1. The pin
configuration and package are shown in Figure 2. Signal pin
assignments and functional pin descriptions are provided in
Table 1.
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
202709B • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • May 6, 2013
1
PRELIMINARY DATA SHEET • SKY13488 SP12T ANTENNA SWITCH WITH MIPI INTERFACE
Table 1. SKY13488 Signal Descriptions
Pin #
Description
Pin #
Name
Description
1
ANT
Antenna port
11
TRX2
Ultra low-loss 3G WCDMA transmit/receive
port 2. This pin either connected directly to
or is disconnected from pin 1, depending on
the applied control data.
2
TRX6
3G WCDMA transmit/receive port 6. This pin
either connected directly to or is
disconnected from pin 1, depending on the
applied control data.
12
TRX1
Ultra low-loss 3G WCDMA transmit/receive
port 1. This pin either connected directly to
or is disconnected from pin 1, depending on
the applied control data.
3
TRX5
3G WCDMA transmit/receive port 5. This pin
either connected directly to or is
disconnected from pin 1, depending on the
applied control data.
13
TRX10
3G WCDMA transmit/receive port 10. This
pin either connected directly to or is
disconnected from pin 1, depending on the
applied control data.
4
TRX4
Ultra low-loss 3G WCDMA transmit/receive
port 4. This pin either connected directly to
or is disconnected from pin 1, depending on
the applied control data.
14
TRX9
3G WCDMA transmit/receive port 9. This pin
either connected directly to or is
disconnected from pin 1, depending on the
applied control data.
5
TRX3
Ultra low-loss 3G WCDMA transmit/receive
port 3. This pin either connected directly to
or is disconnected from pin 1, depending on
the applied control data.
15
TRX8
3G WCDMA transmit/receive port 8. This pin
either connected directly to or is
disconnected from pin 1, depending on the
applied control data.
6
MIPI_SELECT
MIPI interface select. When this pin is
grounded, the switch responds to any of the
power mode triggers. When this pin is left
open, the switch is RFFE MIPI compliant and
responds to individual power mode triggers.
16
TRX7
3G WCDMA transmit/receive port 7. This pin
either connected directly to or is
disconnected from pin 1, depending on the
applied control data.
7
VDD
DC power supply
17
GND
Ground
8
VIO
MIPI decoder enable/reference voltage
18
TXHB
GSM transmit high band. This pin either
connected directly to or is disconnected
from pin 1, depending on the applied control
data.
9
SDATA
Data input/output
19
TXLB
GSM transmit low band. This pin either
connected directly to or is disconnected
from pin 1, depending on the applied control
data.
SCLK
Clock signal
20
GND
Ground
10
Note:
Name
Bottom ground paddles must be connected to ground.
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
2
May 6, 2013 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 202709B
PRELIMINARY DATA SHEET • SKY13488 SP12T ANTENNA SWITCH WITH MIPI INTERFACE
Table 2. SKY13488 Absolute Maximum Ratings
Parameter
Symbol
Minimum
Maximum
Units
2.5
6.0
V
Supply voltage
VDD
MIPI decoder enable/reference voltage
VIO
2
V
Clock signal voltage
SCLK
VIO
V
Data signal voltage
SDATA
VIO
V
RF input power, all TRXx pins
PIN
+31
dBm
Storage temperature
TSTG
–55
+150
°C
Operating temperature
TOP
–30
+90
°C
Note:
Exposure to maximum rating conditions for extended periods may reduce device reliability. There is no damage to device with only one parameter set at the limit and all other
parameters set at or below their nominal value. Exceeding any of the limits listed here may result in permanent damage to the device.
CAUTION: Although this device is designed to be as robust as possible, Electrostatic Discharge (ESD) can damage this device. This device
must be protected at all times from ESD. Static charges may easily produce potentials of several kilovolts on the human body
or equipment, which can discharge without detection. Industry-standard ESD precautions should be used at all times.
Electrical and Mechanical Specifications
The absolute maximum ratings of the SKY13488 are provided in
Table 2. Electrical specifications are provided in Tables 3 and 4.
IMD2 and IMD3 test conditions for various frequencies are listed in
Tables 5 and 6, respectively.
Triple Beat Ratio (TBR) test conditions for bands 2 and 5 are listed
in Table 7.
Figure 3 illustrates the test setup used to measure intermodulation
products. This industry standardized test is used to simulate the
WCDMA Band 1 linearity of the antenna switch. A +20 dBm
Continuous Wave (CW) signal, fFUND, is sequentially applied to the
TRX1 through TRX10 ports, while a –15 dBm CW blocker signal,
fBLK, is applied to the ANT port.
The resulting 3rd Order Intermodulation Distortion (IMD3), fRX, is
measured over all phases of fFUND. The SKY13488 exhibits
exceptional performance for all TRXx ports.
Table 8 describes the register content and programming
read/write sequences. Refer to the MIPI Alliance Specification for
RF Front-End Control Interface (RFFE), v1.10 (26 July 2011) for
additional information on MIPI programming sequences and MIPI
bus specifications.
Figures 4 and 5 provide the timing diagrams for register write
commands and read commands, respectively.
Table 9 provides the Register_0 logic. Table 10 describes the
register parameters and bit values.
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
202709B • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • May 6, 2013
3
PRELIMINARY DATA SHEET • SKY13488 SP12T ANTENNA SWITCH WITH MIPI INTERFACE
Table 3. SKY13488 DC Electrical Specifications (Note 1)
(VDD = 2.85 V, TOP = +25 °C, Characteristic Impedance [ZO] = 50 Ω, Unless Otherwise Noted)
Parameter
Symbol
Supply voltage
VDD
Supply current, active mode
IDD
Interface supply voltage
VIO
Interface signal:
High
Low
SDATA
Test Condition
Min
Typical
Max
2.50
2.85
6.00
V
45
80
μA
1.80
1.95
V
0.2 × VIO
V
V
10
5
μA
μA
Max
Units
2.7
GHz
1.65
0.8 × VIO
Control current:
High
Low
Units
Note 1: Performance is guaranteed only under the conditions listed in this Table.
Table 4. SKY13488 RF Electrical Specifications (Note 1) (1 of 2)
(VDD = 2.85 V, TOP = +25 °C, Characteristic Impedance [ZO] = 50 Ω, Unless Otherwise Noted)
Parameter
Symbol
Operating frequency
f
Insertion loss
IL
Isolation (TRXx to any off TRXx port
[non-adjacent ports])
Iso
Isolation (TRXx to any off TRXx port
[adjacent ports])
Iso
On state match
VSWR
GSM harmonics:
High band
2fo, 3fo
Low band
TRXx harmonics
2fo, 3fo
Test Condition
Min
Typical
0.7
TXLB, 824 to 915 MHz
1.25
dB
TXHB, 1710 to 1910 MHz
1.25
dB
TRXx ports:
824 to 915 MHz
1710 to 2170 MHz
0.50
0.65
dB
dB
TRX4 to TRX10 ports,
1880 to 2690 MHz
0.90
dB
TRX1/2/3 ports:
1880 to 2690 MHz
3500 to 3800 MHz
0.7
1.1
dB
35
dB
Up to 2.0 GHz
30
dB
Up to 2.7 GHz
25
dB
Up to 1.0 GHz
26
dB
Up to 2.0 GHz
23
dB
Up to 2.7 GHz
20
dB
Up to 2.7 GHz
1.5:1
–
PIN = +33 dBm, 50 Ω
PIN = +33 dBm, 5:1 VSWR
–55
–45
dBm
dBm
PIN = +35 dBm, 50 Ω
PIN = +35 dBm, 5:1 VSWR
–55
–45
dBm
dBm
PIN = +27 dBm, 50 Ω,
f = 704 to 2700 MHz
–55
dBm
–55
dBm
PIN = +27 dBm,
5:1 VSWR,
f = 704 to 2700 MHz
TRX1 through TRX10, band 13 2nd
harmonics
2fo
dB
Up to 1.0 GHz
PIN = +25 dBm,
f = 787 MHz
–81
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
4
May 6, 2013 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 202709B
dBm
PRELIMINARY DATA SHEET • SKY13488 SP12T ANTENNA SWITCH WITH MIPI INTERFACE
Table 4. SKY13488 RF Electrical Specifications (Note 1) (2 of 2)
(VDD = 2.85 V, TOP = +25 °C, Characteristic Impedance [ZO] = 50 Ω, Unless Otherwise Noted)
Parameter
Symbol
nd
Test Condition
Min
Typical
Max
Units
2 Order Intermodulation Distortion
IMD2
See test conditions in
Table 5
–110
–105
dBm
3rd Order Intermodulation Distortion
IMD3
See test conditions in
Table 6
–110
–105
dBm
Triple Beat Ratio:
650 to 900 MHz
1710 to 2155 MHz
TBR
See test conditions in
Table 7
Turn-on time
tON
From application of VDD
and VIO
Switching speed
tS
Port to port
+85
+85
dBc
dBc
20
μs
5
μs
2
Note 1: Performance is guaranteed only under the conditions listed in this Table.
Table 5. IMD2 Test Conditions
Band
Transmit
Frequency
(MHz)
Transmit Power
(dBm)
Frequency
Blocker, Low
(MHz)
Frequency
Blocker, High
(MHz)
190
4090
1
1950.0
2
1880.0
80
3840
1960.0
4
1732.0
400
3864
2132.0
5
836.5
45
1718
7
2535.0
120
5187
2655.0
8
897.0
45
1839
942.0
+20
Power Blocker
(dBm)
Receive Frequency
(MHz)
2140.0
–15
881.5
Table 6. IMD3 Test Conditions
Band
Transmit Frequency
(MHz)
Transmit Power
(dBm)
1
1950.0
1760.0
2140.0
2
1880.0
1800.0
1960.0
4
1732.0
5
836.5
7
2535.0
2415.0
2655.0
8
897.0
852.0
942.0
+20
Frequency Blocker
(MHz)
Power Blocker
(dBm)
1332.0
Receive Frequency
(MHz)
2132.0
–15
791.5
881.5
Table 7. Triple Beat Ratio Test Conditions
Band
Transmit
Frequency 1
(MHz)
2
1880.0
5
836.5
Transmit Power 1
(dBm)
+21.5
Transmit
Frequency 2
(MHz)
1881.0
881.5
Transmit Power 2
(dBm)
+21.5
Frequency
Blocker @ ANT
(MHz)
1960.0
881.5
Power
Blocker
(dBm)
–30
TBR Product
Frequency
(MHz)
1960.0 ± 1
881.5 ± 1
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
202709B • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • May 6, 2013
5
PRELIMINARY DATA SHEET • SKY13488 SP12T ANTENNA SWITCH WITH MIPI INTERFACE
Figure 3. 3rd Order Intermodulation Test Setup
Table 8. Command Sequence Bit Definitions
Extended Operation
Type
SSC
C11C8
Reg0
Write
Y
SA[3:0]
1
Data[6:5]
Data[4]
Data{3:0]
Y
Y
–
–
–
–
–
–
Reg
Write
Y
SA[3:0]
0
10
Addr[4]
Addr[3:0]
Y
–
Data[7:0]
–
–
–
Y
Y
Reg
Read
Y
SA[3:0]
0
11
Addr[4]
Addr[3:0]
Y
Y
Data[7:0]
–
–
–
Y
Y
Legend:
SSC = Sequence start command
C = Command frame bits
C7
C6-C5
C4
DA = Data/address frame bits
BPC = Bus park cycle
C3-C0
Parity
Bits
BPC
DA7(1)DA0(1)
Parity
Bits
BPC
DA7(n)DA0(n)
Parity
Bits
BPC
BC = Byte count (# of consecutive addresses)
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
6
May 6, 2013 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 202709B
PRELIMINARY DATA SHEET • SKY13488 SP12T ANTENNA SWITCH WITH MIPI INTERFACE
Figure 4. Register Write Command Timing Diagram
Figure 5. Register Read Command Timing Diagram
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
202709B • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • May 6, 2013
7
PRELIMINARY DATA SHEET • SKY13488 SP12T ANTENNA SWITCH WITH MIPI INTERFACE
Table 9. Register_0 Truth Table
Register_0 Bits
Antenna Path
Bit[7]
Bit[6]
Bit[5]
Bit[4]
Bit[3]
Bit[2]
Bit[1]
Bit[0]
Sleep mode (standby)
X
0
0
0
0
0
0
0
2G transmit low band
X
0
0
0
1
0
1
0
2G transmit high band
X
0
0
0
1
0
0
0
TRX1
X
0
0
0
0
1
0
0
TRX2
X
0
0
0
0
1
0
1
TRX3
X
0
0
0
0
1
1
0
TRX4
X
0
0
0
0
1
1
1
TRX5
X
0
0
0
1
0
0
1
TRX6
X
0
0
0
1
0
1
1
TRX7
X
0
0
0
1
1
0
0
TRX8
X
0
0
0
0
0
0
1
TRX9
X
0
0
0
0
0
1
0
TRX10
X
0
0
0
0
0
1
1
Isolation mode (warm-up)
X
1
1
1
1
1
1
1
Table 10. Register Description and Programming (1 of 3)
Register
Name
Address
(Hex)
Register_0
0000
Parameter
MODE_CTRL
Default
(Binary)
Description
Bits[7:0]:
–
Switch control. See Table 8 for logic
SOFTWARE RESET
Bit[7]:
0
Resets all data to default values except for USID, GSID, or the
contents of the PM_TRIG Register.
0 = Normal operation
1 = Software reset
COMMAND_FRAME_PARITY_ERR
Bit[6]:
0
Command sequence received with parity error – discard command.
COMMAND_LENGTH_ERR
Bit[5]:
0
Command length error.
ADDRESS_FRAME_PARITY_ERR
RFFE_STATUS
001A
Bit[4]:
0
Address frame parity error =1.
DATA_FRAME_PARITY_ERR
Bit[3]:
0
Data frame with parity error.
READ_UNUSED_REG
Bit[2]:
0
Read command to an invalid address.
WRITE_UNUSED_REG
Bit[1]:
0
Write command to an invalid address.
BID_GID_ERR
Bit[0]:
Read command with a BROADCAST_ID (refer to the MIPI Alliance
Specification) or GSID.
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
8
May 6, 2013 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 202709B
0
PRELIMINARY DATA SHEET • SKY13488 SP12T ANTENNA SWITCH WITH MIPI INTERFACE
Table 10. Register Description and Programming (2 of 3)
Register
Name
GROUP_SID
Parameter
Address
(Hex)
001B
Default
(Binary)
Description
Reserved
Bits[7:4]: Reserved
0000
GSID
Bits[3:0]:
0000
Group slave ID
PWR_MODE
Bits[7:6]:
01
00 = Normal operation (active)
01 = Default settings (startup)
10 = Low power (low power)
11 = Reserved
Trigger_Mask_2
Bit[5]:
0
If this bit is set, trigger 2 is disabled. When all triggers are disabled,
if writing to a register that is associated with trigger 2, the data goes
directly to the destination register.
Trigger_Mask_1
PM_TRIG
(Note 1)
001C
Bit[4]:
0
If this bit is set, trigger 1 is disabled. When all triggers are disabled,
if writing to a register that is associated with trigger 1, the data goes
directly to the destination register.
Trigger_Mask_0
Bit[3]:
0
If this bit is set, trigger 0 is disabled. When all triggers are disabled,
if writing to a register that is associated with trigger 0, the data goes
directly to the destination register.
Trigger_2
Bit[2]:
0
If this bit is set, data is loaded into the trigger 2 registers.
Trigger_1
Bit[1]:
0
If this bit is set, data is loaded into the trigger 1 registers
(unsupported).
Trigger_0
Bit[0]:
0
If this bit is set, data is loaded into the trigger 0 registers
(unsupported).
PRODUCT_ID
001D
PRODUCT_ID
Bits[7:0]:
01011111
This is a read-only register. However, during the programming of the
Unique Slave Identifier (USID), a write command sequence is
performed on this register but the value is not changed.
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
202709B • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • May 6, 2013
9
PRELIMINARY DATA SHEET • SKY13488 SP12T ANTENNA SWITCH WITH MIPI INTERFACE
Table 10. Register Description and Programming (3 of 3)
Register
Name
Address
(Hex)
MANUFACTURER_ID
001E
Parameter
MANUFACTURER_ID
Default
(Binary)
Description
Bits[7:0]:
10100101
Read-only register
Reserved
Bits[7:6]:
MANUFACTURER_ID
Bits[5:4]:
00
Reserved
MAN_USID
001F
01
Read-only register
USID
Bits[3:0]:
1011
Programmable USID. A write to these bits programs the USID.
Note 1: Unlike the complete independence between triggers 0, 1, and 2, and also between the associated trigger masks 0, 1, and 2, respectively, as described in the MIPI RFFE Specification,
this device uses additional interactions between the provided trigger functions.
The delayed application of updated data to all triggerable registers in this device may be accomplished using any of the three triggers (0, 1, or 2), provided that the particular trigger
used is not currently masked off. If multiple triggers are enabled, any or all of those are sufficient to cause the data to be transferred from shadow registers to destination registers for
all triggerable registers in the device.
It is also necessary to disable all three triggers (i.e., set all three trigger masks) to ensure that data written to any triggerable register will immediately be written to the destination
register at the conclusion of the RFFE command sequence where the data is written.
Evaluation Board Description
Package and Handling Information
The SKY13488 Evaluation Board is used to test the performance
of the SKY13488 SP12T Switch. An Evaluation Board schematic
diagram is provided in Figure 6. A recommended ESD protection
circuit diagram is provided in Figure 7. An assembly drawing for
the Evaluation Board is shown in Figure 8.
Since the device package is sensitive to moisture absorption, it is
baked and vacuum packed before shipping. Instructions on the
shipping container label regarding exposure to moisture after the
container seal is broken must be followed. Otherwise, problems
related to moisture absorption may occur when the part is
subjected to high temperature during solder assembly.
Package Dimensions
The PCB layout footprint for the SKY13488 is provided in Figure 9.
Typical case markings are shown in Figure 10. Package
dimensions for the 20-pin MCM are shown in Figure 11, and tape
and reel dimensions are provided in Figure 12.
The SKY13488 is rated to Moisture Sensitivity Level 3 (MSL3) at
260 °C. It can be used for lead or lead-free soldering. For
additional information, refer to the Skyworks Application Note,
PCB Design and SMT Assembly/Rework Guidelines for MCM-L
Packages, document number 101752.
Care must be taken when attaching this product, whether it is
done manually or in a production solder reflow environment.
Production quantities of this product are shipped in a standard
tape and reel format.
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
10
May 6, 2013 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 202709B
PRELIMINARY DATA SHEET • SKY13488 SP12T ANTENNA SWITCH WITH MIPI INTERFACE
*** TBD ***
Figure 6. SKY13488 Evaluation Board Schematic
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
202709B • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • May 6, 2013
11
PRELIMINARY DATA SHEET • SKY13488 SP12T ANTENNA SWITCH WITH MIPI INTERFACE
Figure 7. SKY13488 Recommended ESD Protection Circuits
Figure 8. SKY13488 Evaluation Board Assembly Diagram
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
12
May 6, 2013 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 202709B
PRELIMINARY DATA SHEET • SKY13488 SP12T ANTENNA SWITCH WITH MIPI INTERFACE
Figure 9. SKY13488 PCB Layout Footprint
(Top View)
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
202709B • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • May 6, 2013
13
PRELIMINARY DATA SHEET • SKY13488 SP12T ANTENNA SWITCH WITH MIPI INTERFACE
*** TBD ***
Figure 10. Typical Part Markings
(Top View)
Figure 11. SKY13488 20-Pin MCM Package Dimensions
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
14
May 6, 2013 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 202709B
PRELIMINARY DATA SHEET • SKY13488 SP12T ANTENNA SWITCH WITH MIPI INTERFACE
Figure 12. SKY13488 Tape and Reel Dimensions
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
202709B • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • May 6, 2013
15
PRELIMINARY DATA SHEET • SKY13488 SP12T ANTENNA SWITCH WITH MIPI INTERFACE
Ordering Information
Model Name
SKY13488 0.4-3.8 GHz SP12T Antenna Switch with MIPI
Interface
Manufacturing Part Number
SKY13488
Evaluation Board Part Number
*** TBD ***
Copyright © 2013 Skyworks Solutions, Inc. All Rights Reserved.
Information in this document is provided in connection with Skyworks Solutions, Inc. (“Skyworks”) products or services. These materials, including the information contained herein, are provided by
Skyworks as a service to its customers and may be used for informational purposes only by the customer. Skyworks assumes no responsibility for errors or omissions in these materials or the
information contained herein. Skyworks may change its documentation, products, services, specifications or product descriptions at any time, without notice. Skyworks makes no commitment to
update the materials or information and shall have no responsibility whatsoever for conflicts, incompatibilities, or other difficulties arising from any future changes.
No license, whether express, implied, by estoppel or otherwise, is granted to any intellectual property rights by this document. Skyworks assumes no liability for any materials, products or
information provided hereunder, including the sale, distribution, reproduction or use of Skyworks products, information or materials, except as may be provided in Skyworks Terms and Conditions of
Sale.
THE MATERIALS, PRODUCTS AND INFORMATION ARE PROVIDED “AS IS” WITHOUT WARRANTY OF ANY KIND, WHETHER EXPRESS, IMPLIED, STATUTORY, OR OTHERWISE, INCLUDING FITNESS FOR A
PARTICULAR PURPOSE OR USE, MERCHANTABILITY, PERFORMANCE, QUALITY OR NON-INFRINGEMENT OF ANY INTELLECTUAL PROPERTY RIGHT; ALL SUCH WARRANTIES ARE HEREBY EXPRESSLY
DISCLAIMED. SKYWORKS DOES NOT WARRANT THE ACCURACY OR COMPLETENESS OF THE INFORMATION, TEXT, GRAPHICS OR OTHER ITEMS CONTAINED WITHIN THESE MATERIALS. SKYWORKS
SHALL NOT BE LIABLE FOR ANY DAMAGES, INCLUDING BUT NOT LIMITED TO ANY SPECIAL, INDIRECT, INCIDENTAL, STATUTORY, OR CONSEQUENTIAL DAMAGES, INCLUDING WITHOUT LIMITATION,
LOST REVENUES OR LOST PROFITS THAT MAY RESULT FROM THE USE OF THE MATERIALS OR INFORMATION, WHETHER OR NOT THE RECIPIENT OF MATERIALS HAS BEEN ADVISED OF THE
POSSIBILITY OF SUCH DAMAGE.
Skyworks products are not intended for use in medical, lifesaving or life-sustaining applications, or other equipment in which the failure of the Skyworks products could lead to personal injury,
death, physical or environmental damage. Skyworks customers using or selling Skyworks products for use in such applications do so at their own risk and agree to fully indemnify Skyworks for any
damages resulting from such improper use or sale.
Customers are responsible for their products and applications using Skyworks products, which may deviate from published specifications as a result of design defects, errors, or operation of
products outside of published parameters or design specifications. Customers should include design and operating safeguards to minimize these and other risks. Skyworks assumes no liability for
applications assistance, customer product design, or damage to any equipment resulting from the use of Skyworks products outside of stated published specifications or parameters.
Skyworks, the Skyworks symbol, and “Breakthrough Simplicity” are trademarks or registered trademarks of Skyworks Solutions, Inc., in the United States and other countries. Third-party brands
and names are for identification purposes only, and are the property of their respective owners. Additional information, including relevant terms and conditions, posted at www.skyworksinc.com,
are incorporated by reference.
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
16
May 6, 2013 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 202709B