DATA SHEET SKY13550-667LF: 0.4 to 3.8 GHz DP8T (SP4T/SP4T) Main/Receive Diversity Switch with MIPI RFFE Interface for Carrier Aggregation Applications 3G/4G multimode cellular handsets (UMTS and CDMA2000) Carrier aggregation diversity TRXA1 TRXA2 ANT_A TRXA3 TRXA4 TRXB2 Excellent Band 17 3 harmonic performance TRXB3 Integrated, programmable MIPI interface using separate registers for ANT_A and ANT_B bands TRXB4 Dual antenna ports can be connected externally to a diplexer Small QFN (14-pin, 1.6 x 2.0 x 0.55 mm) package (MSL1, 260 C per JEDEC J-STD-020) Skyworks GreenTM products are compliant with all applicable legislation and are halogen-free. For additional information, refer to Skyworks Definition of GreenTM, document number SQ04–0074. Description The SKY13550-667LF is a dual single-pole, four-throw (2xSP4T) Mobile Industry Processor Interface (MIPI) controlled antenna switch designed specifically for receive diversity in carrier aggregation applications. The 2xSP4T switch is optimized for broadband performance. Using advanced switching technologies, the SKY13550-667LF maintains low insertion loss and high isolation for all switching paths. The high linearity performance and low insertion loss achieved by the SKY13550-667LF makes it an ideal choice for carrier aggregation applications. The switch also exhibits excellent second/third order intermodulation distortion (IMD2/IMD3) performance. ANT_B Bias VDD rd Logic Block GND Excellent Band 13 2nd harmonic performance TRXB1 SDATA Single, positive DC power supply (2.5 to 4.8 V) SCLK Broadband frequency range: 0.4 to 3.8 GHz VIO Features 203284D-001 Figure 1. SKY13550-667LF Block Diagram Switching is controlled by an integrated MIPI decoder. The two switches can be configured independently. There are separate registers for each SP4T. No external DC blocking capacitors are required on the RF paths as long as no DC voltage is applied to those paths. The SKY13550-667LF is manufactured in a compact, 1.6 x 2.0 x 0.55 mm, 14-pin surface-mount Quad Flat No-Lead (QFN) package. A functional block diagram is shown in Figure 1. The pin configuration and package are shown in Figure 2. Signal pin assignments and functional pin descriptions are provided in Table 1. Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com 203284E • Skyworks Proprietary and Confidential Information • Products and Product Information are Subject to Change Without Notice • January 20, 2016 1 1 TRXB2 ANT_A TRXB1 ANT_B DATA SHEET • SKY13550-667LF: DP8T MAIN/RECEIVE DIVERSITY SWITCH FOR CARRIER AGGREGATION 14 13 12 TRXA1 2 11 TRXA2 TRXB3 3 10 TRXA3 TRXB4 4 9 TRXA4 VDD 5 7 SDATA VIO 6 SCLK 8 203284D-002 Figure 2. SKY13550-667LF Pinout (Top View) Table 1. SKY13550-667LF Signal Descriptions1 Pin Name Description Pin 8 Name SCLK Description 1 TRXB1 ANT_B transmit/receive arm 1 Clock 2 TRXB2 ANT_B transmit/receive arm 2 9 TRXA4 ANT_A transmit/receive arm 4 3 TRXB3 ANT_B transmit/receive arm 3 10 TRXA3 ANT_A transmit/receive arm 3 4 TRXB4 ANT_B transmit/receive arm 4 11 TRXA2 ANT_A transmit/receive arm 2 5 VDD DC supply voltage 12 TRXA1 ANT_A transmit/receive arm 1 6 VIO MIPI interface DC voltage 13 ANT_A Antenna A port 7 SDATA Data 14 ANT_B Antenna B port 1 Bottom ground paddles must be connected to ground. Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com 2 January 20, 2016 • Skyworks Proprietary and Confidential Information • Products and Product Information are Subject to Change Without Notice • 203284E DATA SHEET • SKY13550-667LF: DP8T RECEIVE MAIN/DIVERSITY SWITCH FOR CARRIER AGGREGATION Electrical and Mechanical Specifications Table 7 describes the register content and programming read/write sequences. Refer to the MIPI Alliance Specification for RF Front-End Control Interface (RFFE), v1.10 (26 July 2011) for additional information on MIPI programming sequences and MIPI bus specifications. The absolute maximum ratings of the SKY13550-667LF are provided in Table 2. Electrical specifications are provided in Tables 3 and 4. IMD2 and IMD3 test conditions for various frequencies are listed in Tables 5 and 6, respectively. Figure 3 illustrates the test setup used to measure intermodulation products. This industry standardized test is used to simulate the WCDMA linearity of the antenna switch. A +20 dBm Continuous Wave (CW) signal, fFUND, is sequentially applied to the TRX ports, while a –15 dBm CW blocker signal, fBLK, is applied to the ANT port. Figure 4 provides the timing diagram for register write commands. Figure 5 provides the timing diagram for register read commands. Register descriptions and programming information is provided in Table 8. Tables 9 and 10 provide the Register_0 and Register_1 logic, respectively. The resulting third order intermodulation distortion (IMD3), fRX, is measured over all phases of fFUND. The SKY13550-667LF exhibits exceptional performance for all RF ports. Table 2. SKY13550-667LF Absolute Maximum Ratings1 Parameter Symbol Minimum Maximum Units 2.5 5.0 V 2 V Supply voltage VDD Digital control signal VIO SCLK port voltage SCLK VIO V SDATA port voltage SDATA VIO V LTE input power PIN +31 dBm Storage temperature TSTG –55 +150 C Operating temperature TOP –30 +90 C 1 Exposure to maximum rating conditions for extended periods may reduce device reliability. There is no damage to device with only one parameter set at the limit and all other parameters set at or below their nominal value. Exceeding any of the limits listed here may result in permanent damage to the device. CAUTION: Although this device is designed to be as robust as possible, electrostatic discharge (ESD) can damage this device. This device must be protected at all times from ESD. Static charges may easily produce potentials of several kilovolts on the human body or equipment, which can discharge without detection. Industry-standard ESD precautions should be used at all times. Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com 203284E • Skyworks Proprietary and Confidential Information • Products and Product Information are Subject to Change Without Notice • January 20, 2016 3 DATA SHEET • SKY13550-667LF: DP8T MAIN/RECEIVE DIVERSITY SWITCH FOR CARRIER AGGREGATION Table 3. SKY13550-667LF RF Electrical Specifications1 (1 of 2) (VDD = 2.85 V, TOP = +25 C, Characteristic Impedance [ZO] = 50 Ω, Unless Otherwise Noted) Parameter Symbol Operating frequency f Insertion loss IL Test Condition Min 0.4 Iso Max Units 3.8 GHz 0.55 0.6 0.7 0.8 0.95 1.6 dB dB dB dB dB dB ANT_A to any TRXA port, ANT_B to any TRXB port: 0.35 0.4 0.5 0.65 0.8 1.4 400 to 824 MHz 824 to 960 MHz 1427 to 1511 MHz 1710 to 2170 MHz 2170 to 2690 MHz 3400 to 3800 MHz Isolation Typical ANT_A to any OFF TRXA port, ANT_B to any OFF TRXB port: Up to 787 MHz Up to 960 MHz Up to 1511 MHz Up to 1990 MHz Up to 2170 MHz Up to 2690 MHz Up to 3800 MHz 33 32 25 24 23 21 17 36 34 29 27 26 23 19 dB dB dB dB dB dB dB 41 39 35 33 32 30 25 43 41 37 35 34 32 27 dB dB dB dB dB dB dB 32 28 26 23 20 34 30 28 25 22 dB dB dB dB dB ANT_A to any TRxB port, ANT_B to any TRxA port: Up to 704 MHz Up to 960 MHz Up to 1511 MHz Up to 1990 MHz Up to 2170 MHz Up to 2690 MHz Up to 3800 MHz ANT_A to ANT_B: 400 to 960 GHz 1427 to 1511 MHz 1710 to 1980 GHz 1980 to 2690 MHz 3400 to 3800 GHz Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com 4 January 20, 2016 • Skyworks Proprietary and Confidential Information • Products and Product Information are Subject to Change Without Notice • 203284E DATA SHEET • SKY13550-667LF: DP8T RECEIVE MAIN/DIVERSITY SWITCH FOR CARRIER AGGREGATION Table 3. SKY13550-667LF RF Electrical Specifications1 (2 of 2) (VDD = 2.85 V, TOP = +25 C, Characteristic Impedance [ZO] = 50 Ω, Unless Otherwise Noted) Parameter Symbol Test Condition Min Typical Max Units ON state match VSWR 400 to 2170 MHz 1.2:1 1.5:1 Second order intermodulation distortion IMD2 See Table 5 –110 –105 dBm Third order intermodulation distortion IMD3 See Table 6 –110 –105 dBm 2fo, 3fo Any TRX port, PIN = +25 dBm, f = 900 MHz –70 –65 dBm Any TRX port, PIN = +25 dBm, f0 = 900 MHz, VSWR = 5:1 –65 –60 dBm nd rd nd rd nd rd Low band 2 and 3 harmonic Low band 2 and 3 harmonic 2fo, 3fo Mid band 2 and 3 harmonic 2fo, 3fo Any TRXA and any TRXB port, PIN = +26 dBm, f1 = 1462 MHz, f2 = 1910 MHz –70 –65 dBm Mid band 2nd and 3rd harmonic 2fo, 3fo Any TRXA and any TRXB port, PIN = +26 dBm, , f1 = 1462 MHz, f2 = 1910 MHz, VSWR =5:1 –63 –60 dBm nd rd High band 2 and 3 harmonic 2fo, 3fo Any TRXA and any TRXB port, PIN = +25 dBm, fo = 2690 MHz –70 –65 dBm High band 2nd and 3rd harmonic 2fo, 3fo Any TRXA and any TRXB port, PIN = +25 dBm, fo = 2690 MHz, VSWR = 5:1 –62 –60 dBm Any TRX port, PIN = +25 dBm, f0 = 777 to 787 MHz –81 dBm Any TRX port, PIN = +25 dBm, f = 707 MHz –80 dBm nd Band 13 2 harmonic rd Band 17 3 harmonic 2fo 3fo Turn-on time tON From application of VDD and VIO, or transition from low power mode 4 10 μs Wake-up time tW From isolation state 2 5 μs Switching speed tS Any state to any other state 2 5 μs 1 Performance is guaranteed only under the conditions listed in this table. Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com 203284E • Skyworks Proprietary and Confidential Information • Products and Product Information are Subject to Change Without Notice • January 20, 2016 5 DATA SHEET • SKY13550-667LF: DP8T MAIN/RECEIVE DIVERSITY SWITCH FOR CARRIER AGGREGATION Table 4. SKY13550-667LF DC Electrical Specifications1 (VDD = 2.85 V, VIO = 1.8 V, TOP = +25 C, Characteristic Impedance [ZO] = 50 Ω, Unless Otherwise Noted) Parameter Symbol Supply voltage VDD Supply current, active mode IDD Interface supply voltage level VIO Digital data and clock signals: High Low SDATA, SCLK Interface supply current IVIO Test Condition Min Typical 2.50 2.85 4.8 V 50 100 μA 1.80 1.95 V VIO 0.2 × VIO V V 50 μA 1.65 Max 0.8 × VIO 0 5 Units 1 Performance is guaranteed only under the conditions listed in this table. Table 5. IMD2 Test Conditions Band Transmit Frequency (MHz) 1 1950.0 190 4090 2140.0 2 1880.0 80 3840 1960.0 4 1732.0 5 836.5 7 Transmit Power (dBm) Frequency Blocker, Low (MHz) Frequency Blocker, High (MHz) Power Blocker (dBm) Receive Frequency (MHz) 400 3864 45 1718 2535.0 120 5190 2655.0 8 897.0 45 1839 942.0 11/21 1452.0 2952 1500 +20 2132.0 881.5 –15 Table 6. IMD3 Test Conditions Band Transmit Frequency (MHz) Transmit Power (dBm) Frequency Blocker (MHz) Power Blocker (dBm) Receive Frequency (MHz) 1 1950.0 1760.0 2140.0 2 1880.0 1800.0 1960.0 4 1732.0 5 836.5 7 2535.0 2415.0 2655.0 8 897.0 852.0 942.0 11/21 1452 1404 1500 1332.0 +20 791.5 2132.0 –15 881.5 Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com 6 January 20, 2016 • Skyworks Proprietary and Confidential Information • Products and Product Information are Subject to Change Without Notice • 203284E DATA SHEET • SKY13550-667LF: DP8T RECEIVE MAIN/DIVERSITY SWITCH FOR CARRIER AGGREGATION fBLK 1760 MHz, –15 dBm fFUND 1950 MHz, +20 dBm fRX 2140 MHz, Measure Tone Circulator Signal Generator fFUND = 1950 MHz, +20 dBm Coupler to Monitor Input Power 1950 MHz Bandpass Filter Circulator Duplexer Skyworks Switch fFUND = +20 dBm fBLK = –15 dBm Phase Shifter Signal Generator fBLK = 1760 MHz, –15 dBm 1760 MHz Bandpass Filter Spectrum Analyzer fRX = 2140 MHz 203284D-003 Figure 3. Typical Third Order Intermodulation Test Setup Table 7. Command Sequence Bit Definitions Extended Operation Type SSC C11-C8 C7 C6-C5 C4 C3-C0 Parity Bits BPC DA7(1)DA0(1) Parity Bits BPC DA7(n)DA0(n) Parity Bits BPC Reg_0 Write, Short Command Y SA[3:0] 1b Data[6:5] Data[4] Data{3:0] Y Y – – – – – – Reg_0 Write, Long Command Y SA[3:0] 0 10b Addr[4] Addr[3:0] Y – Data[7:0] – – – Y Y Reg_1 Write Y SA[3:0] 0 10b Addr[4] Addr[3:0] Y – Data[7:0] – – – Y Y Reg Read Y SA[3:0] 0 11b Addr[4] Addr[3:0] Y Y Data[7:0] – – – Y Y Legend: SSC = Sequence start command C = Command frame bits DA = Data/address frame bits BPC = Bus park cycle BC = Byte count (number of consecutive addresses) Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com 203284E • Skyworks Proprietary and Confidential Information • Products and Product Information are Subject to Change Without Notice • January 20, 2016 7 DATA SHEET • SKY13550-667LF: DP8T MAIN/RECEIVE DIVERSITY SWITCH FOR CARRIER AGGREGATION SCLK SDATA SA3 SA2 SA1 0 SA0 SSC 1 0 A4 A3 A2 A1 A0 P Example Register Write Command Frame SCLK SDATA P D7 D6 D5 D4 D3 D2 D1 P D0 Example Data Frame 0 Bus Park Signal Driven by Master Signal Not Driven; Pull-Down Only For Reference Only 203284D-004 Figure 4. Register Write Command Timing Diagram SCLK SDATA SA3 SA2 SA1 0 SA0 1 1 A4 A3 A2 A1 A0 P Example Register Read Command Frame SSC SCLK SDATA P 0 Bus Park D7 D6 D5 D4 D3 D2 D1 Example Data Frame Signal Driven by Master Signal Not Driven; Pull-Down Only Signal Driven by Slave For Reference Only D0 P 0 Bus Park 203284D-005 Figure 5. Register Read Command Timing Diagram Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com 8 January 20, 2016 • Skyworks Proprietary and Confidential Information • Products and Product Information are Subject to Change Without Notice • 203284E DATA SHEET • SKY13550-667LF: DP8T RECEIVE MAIN/DIVERSITY SWITCH FOR CARRIER AGGREGATION Table 8. Register Description and Programming1 Register Name Address (Hex) Register_0 0000 MODE_CTRL Bits[6:0]: Register_1 0001 MODE_CTRL Bits[7:0]: PWR_MODE Bits[7:6]: Parameter Default (Binary) Description 0000000 See Table 10 for logic 00000000 See Table 11 for logic 00 00 = Normal operation (active) 01 = Default settings (startup) 10 = Low power (low power) 11 = Reserved Trigger_Mask_2 Bit[5]: 0 If this bit is set, trigger 2 is disabled. When all triggers are disabled, if writing to a register that is associated with trigger 2, the data goes directly to the destination register. Trigger_Mask_1 PM_TRIG (Note 1) Bit[4]: 0 If this bit is set, trigger 1 is disabled. When all triggers are disabled, if writing to a register that is associated with trigger 1, the data goes directly to the destination register. 001C Trigger_Mask_0 Bit[3]: 0 If this bit is set, trigger 0 is disabled. When all triggers are disabled, if writing to a register that is associated with trigger 0, the data goes directly to the destination register. Trigger_2 Bit[2]: Trigger_1 Bit[1]: 0 If this bit is set, data is loaded into the trigger 2 registers. 0 If this bit is set, data is loaded into the trigger 1 registers. Trigger_0 Bit[0]: 0 If this bit is set, data is loaded into the trigger 0 registers. PRODUCT_ID 001D PRODUCT_ID Bits[7:0]: 11010011 This is a read-only register. However, during the programming of the Unique Slave Identifier (USID), a write command sequence is performed on this register but the value is not changed. MANUFACTURER_ID 001E MANUFACTURER_ID Bits[7:0]: 10100101 Read-only register Reserved Bits[7:6]: 00 Reserved MAN_USID 001F MANUFACTURER_ID Bits[5:4]: 01 Read-only register USID Bits[3:0]: 1010 Programmable USID. A write to these bits programs the USID. 1 Unlike the complete independence between triggers 0, 1, and 2, and also between the associated trigger masks 0, 1, and 2, respectively, as described in the MIPI RFFE Specification, this device uses additional interactions between the provided trigger functions. The delayed application of updated data to all triggerable registers in this device may be accomplished using any of the three triggers (0, 1, or 2), provided that the particular trigger used is not currently masked off. If multiple triggers are enabled, any or all of those are sufficient to cause the data to be transferred from shadow registers to destination registers for all triggerable registers in the device. It is also necessary to disable all three triggers (i.e., set all three trigger masks) to ensure that data written to any triggerable register will immediately be written to the destination register at the conclusion of the RFFE command sequence where the data is written. Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com 203284E • Skyworks Proprietary and Confidential Information • Products and Product Information are Subject to Change Without Notice • January 20, 2016 9 DATA SHEET • SKY13550-667LF: DP8T MAIN/RECEIVE DIVERSITY SWITCH FOR CARRIER AGGREGATION Table 9. Register_0 Truth Table (ANT_B) Register 0 Bits ON State D7 D6 D5 D4 D3 D2 D1 D0 All isolation 0 0 0 0 0 TRXB1 0 0 0 0 1 TRXB2 0 0 0 1 0 0 0 0 1 1 TRXB4 0 0 1 0 0 Isolation 0 0 1 0 1 Isolation 0 0 1 1 0 Isolation 0 0 1 1 1 TRXB4 0 1 0 0 0 TRXB3 0 1 0 0 1 TRXB2 0 1 0 1 0 TRXB1 0 1 0 1 1 TRXB4 0 1 1 0 0 TRXB3 0 1 1 0 1 TRXB2 0 1 1 1 0 TRXB1 0 1 1 1 1 TRXB4+3 1 0 0 0 0 TRXB4+2 1 0 0 0 1 TRXB4+1 1 0 0 1 0 TRXB3+2 1 0 0 1 1 TRXB3+1 1 0 1 0 0 TRXB2+1 1 0 1 0 1 All isolation 1 0 1 1 0 All isolation 1 0 1 1 1 All isolation 1 1 0 0 0 All isolation 1 1 0 0 1 All isolation 1 1 0 1 0 All isolation 1 1 0 1 1 All isolation 1 1 1 0 0 All isolation 1 1 1 0 1 All isolation 1 1 1 1 0 All isolation 1 1 1 1 1 TRXB3 μ Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com 10 January 20, 2016 • Skyworks Proprietary and Confidential Information • Products and Product Information are Subject to Change Without Notice • 203284E DATA SHEET • SKY13550-667LF: DP8T RECEIVE MAIN/DIVERSITY SWITCH FOR CARRIER AGGREGATION Table 10. Register_1 Truth Table (ANT_A) Register 1 Bits Mode D7 D6 D5 D4 D3 D2 D1 D0 All isolation 0 0 0 0 0 TRXA1 0 0 0 0 1 TRXA2 0 0 0 1 0 TRXA3 0 0 0 1 1 TRXA4 0 0 1 0 0 Isolation 0 0 1 0 1 Isolation 0 0 1 1 0 Isolation 0 0 1 1 1 TRXA4 0 1 0 0 0 TRXA3 0 1 0 0 1 TRXA2 0 1 0 1 0 TRXA1 0 1 0 1 1 TRXA4 0 1 1 0 0 TRXA3 0 1 1 0 1 TRXA2 0 1 1 1 0 TRXA1 0 1 1 1 1 TRXA4+3 1 0 0 0 0 TRXA4+2 1 0 0 0 1 TRXA4+1 1 0 0 1 0 TRXA3+2 1 0 0 1 1 TRXA3+1 1 0 1 0 0 TRXA2+1 1 0 1 0 1 All isolation 1 0 1 1 0 All isolation 1 0 1 1 1 All isolation 1 1 0 0 0 All isolation 1 1 0 0 1 All isolation 1 1 0 1 0 All isolation 1 1 0 1 1 All isolation 1 1 1 0 0 All isolation 1 1 1 0 1 All isolation 1 1 1 1 0 All isolation 1 1 1 1 1 Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com 203284E • Skyworks Proprietary and Confidential Information • Products and Product Information are Subject to Change Without Notice • January 20, 2016 11 DATA SHEET • SKY13550-667LF: DP8T MAIN/RECEIVE DIVERSITY SWITCH FOR CARRIER AGGREGATION Evaluation Board Description Package and Handling Information The SKY13550-667LF Evaluation Board is used to test the performance of the SKY13550-667LF DP8T Switch. An Evaluation Board schematic diagram is provided in Figure 6. A recommended ESD protection circuit diagram is provided in Figure 7. An assembly drawing for the Evaluation Board is shown in Figure 8. Instructions on the shipping container label regarding exposure to moisture after the container seal is broken must be followed. Otherwise, problems related to moisture absorption may occur when the part is subjected to high temperature during solder assembly. Package Dimensions The SKY13550-667LF is rated to Moisture Sensitivity Level 1 (MSL1) at 260 C. It can be used for lead or lead-free soldering. For additional information, refer to the Skyworks Application Note, Solder Reflow Information, document number 200164. The PCB layout footprint for the SKY13550-667LF is provided in Figure 9. Typical part markings are shown in Figure 10. Package dimensions are shown in Figure 11, and tape and reel dimensions are provided in Figure 12. Care must be taken when attaching this product, whether it is done manually or in a production solder reflow environment. Production quantities of this product are shipped in a standard tape and reel format. RFC6 RFC5 15 13 RFC3 RFC2 RFC1 1 TRXB1 TRXA1 12 2 TRXB2 TRXA2 11 3 TRXB3 TRXA3 10 4 TRXB4 TRXA4 9 6 7 3 L1 0Ω 4 VIO 5 VDD RFC7 RFC8 RFC9 RFC10 SCLK 8 SDATA RFC4 ANT_A ANT_B 14 C2 100 nF 1 2 5 6 C1 100 nF DCH1 Header 203284D-006 Figure 6. SKY13550-667LF Evaluation Board Schematic Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com 12 January 20, 2016 • Skyworks Proprietary and Confidential Information • Products and Product Information are Subject to Change Without Notice • 203284E DATA SHEET • SKY13550-667LF: DP8T RECEIVE MAIN/DIVERSITY SWITCH FOR CARRIER AGGREGATION 4.7 pF To Application Antenna To SKY13550-667LF Antenna 18 nH 18 nH ESD Circuit 1 12 pF To Application Antenna To SKY13550-667LF Antenna 8.2 nH ESD Circuit 2 203284D-007 Figure 7. SKY13550-667LF Recommended ESD Protection Circuits TRXB2 TRXB3 TRXB1 RF B4 B1 RFB3 RF RFB2 TRXB4 DCH1 ANT_B C1 1 ANT_B ANT_A L1 C2 A4 RF RF A1 ANT_A RFA2 RFA3 GND VDD VIO SDATA SCLK GND TRXA4 TRXA1 TRXA3 TRXA2 203284D-008 Figure 8. SKY13550-667LF Evaluation Board Assembly Diagram Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com 203284E • Skyworks Proprietary and Confidential Information • Products and Product Information are Subject to Change Without Notice • January 20, 2016 13 DATA SHEET • SKY13550-667LF: DP8T MAIN/RECEIVE DIVERSITY SWITCH FOR CARRIER AGGREGATION 4X 0.200 Pin 14 Pin 1 Indicator 0.200 X 0.200 10X 0.500 14X Exposed Solder Area Pin 1 4X 0.700 0.600 4X 0.400 4X 0.800 14X 0.200 14X 0.300 0.500 203284D-009 Dimensions are in millimeters Figure 9. SKY13550-667LF PCB Layout Footprint (Top View) Skyworks Part Number Supplier Code (First Character) XXXX is for QYL Code Character 1 = Q/Y Code Characters 2, 3, and 4 = Lot Code Pin 1 Indicator 203284D-010 Figure 10. Typical Part Markings (Top View) Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com 14 January 20, 2016 • Skyworks Proprietary and Confidential Information • Products and Product Information are Subject to Change Without Notice • 203284E DATA SHEET • SKY13550-667LF: DP8T RECEIVE MAIN/DIVERSITY SWITCH FOR CARRIER AGGREGATION Seating Plane C Pin 1 Indicator 1.60 A B 10X 0.600 –0.004 0.046 Pin 14 Pin 1 4X 0.200 5X R0.050 Pin 1 Indicator 0.201 X 45° 0.400 Pitch 2.00 0.6 ±0.1 4X 0.400 8X 0.800 2X 0.05 C 0.110 Ref 2X 0.05 C 0.05 C 0.05 C Top View 14X 0.100 Exposed Pad 0.55 ±0.05 3 0.5 ±0.1 See Detail A 14X Side View Bottom View 0.2 ±0.05 Notes: 1. 2. 3. 4. 5. 4X R0.020 Dimensions and tolerances according to ASME Y14.5M-1994. Unless otherwise specified, all measurements are in millimeters. Coplanarity applies to the terminals and all other bottom surface metallization. Plating requirement per source control drawing (SCD) 2504. Dimension applies to metallized terminal. If the terminal has a radius on its end, the width dimension should not be measured in that radius area. Tolerances on decimals: .x = ± 0.1 .xx = ± 0.05 .xxx = ±0.025 0.2 ±0.05 0.10 M C A B 5 Detail A Tolerances on angles: Scale 100X 3X This Rotation 3X Rotated 180° 4X Rotated 90° CW 4X Rotated 90° CCW ± 0.5° 203284D-011 Ø1 .50 2.00 ±0.05 +0 –0 .10 .00 4.00 ±0.10 Pin 1 B 5° Max Ø0 0.85 ±0.05 (Ko) 4.00 ±0.10 A B A .6 0 ±0 8.00 +0.30 –0.10 3.50 ±0.05 2.25 ±0.05 (Bo) 0.25 ±0.02 1.75 ±0.10 Figure 11. SKY13550-667LF Package Dimensions .0 5 Section B 5° Max Notes: 1. 2. 3. 4. 5. 6. Carrier tape material: black conductive polystyrene or polycarbonate. Cover tape material: transparent conductive. ESD surface resistivity shall be ≤1 x 1010 Ohms/square per EIA, JEDEC TNR specification. 10-sprocket hole pitch cumulative tolerance: ±0.20 mm. Ao and Bo measured on plane 0.30 mm above the bottom of the pocket. All dimensions are in millimeters. 1.85 ±0.05 (Ao) Section A 203284D-012 Figure 12. SKY13550-667LF Tape and Reel Dimensions Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com 203284E • Skyworks Proprietary and Confidential Information • Products and Product Information are Subject to Change Without Notice • January 20, 2016 15 DATA SHEET • SKY13550-667LF: DP8T MAIN/RECEIVE DIVERSITY SWITCH FOR CARRIER AGGREGATION Ordering Information Model Name SKY13550-667LF: 0.4 to 3.8 GHz DP8T Switch Manufacturing Part Number SKY13550-667LF Evaluation Board Part Number SKY13550-667LF-EVB Copyright © 2014-2016 Skyworks Solutions, Inc. All Rights Reserved. Information in this document is provided in connection with Skyworks Solutions, Inc. (“Skyworks”) products or services. These materials, including the information contained herein, are provided by Skyworks as a service to its customers and may be used for informational purposes only by the customer. Skyworks assumes no responsibility for errors or omissions in these materials or the information contained herein. Skyworks may change its documentation, products, services, specifications or product descriptions at any time, without notice. Skyworks makes no commitment to update the materials or information and shall have no responsibility whatsoever for conflicts, incompatibilities, or other difficulties arising from any future changes. No license, whether express, implied, by estoppel or otherwise, is granted to any intellectual property rights by this document. Skyworks assumes no liability for any materials, products or information provided hereunder, including the sale, distribution, reproduction or use of Skyworks products, information or materials, except as may be provided in Skyworks Terms and Conditions of Sale. THE MATERIALS, PRODUCTS AND INFORMATION ARE PROVIDED “AS IS” WITHOUT WARRANTY OF ANY KIND, WHETHER EXPRESS, IMPLIED, STATUTORY, OR OTHERWISE, INCLUDING FITNESS FOR A PARTICULAR PURPOSE OR USE, MERCHANTABILITY, PERFORMANCE, QUALITY OR NON-INFRINGEMENT OF ANY INTELLECTUAL PROPERTY RIGHT; ALL SUCH WARRANTIES ARE HEREBY EXPRESSLY DISCLAIMED. SKYWORKS DOES NOT WARRANT THE ACCURACY OR COMPLETENESS OF THE INFORMATION, TEXT, GRAPHICS OR OTHER ITEMS CONTAINED WITHIN THESE MATERIALS. SKYWORKS SHALL NOT BE LIABLE FOR ANY DAMAGES, INCLUDING BUT NOT LIMITED TO ANY SPECIAL, INDIRECT, INCIDENTAL, STATUTORY, OR CONSEQUENTIAL DAMAGES, INCLUDING WITHOUT LIMITATION, LOST REVENUES OR LOST PROFITS THAT MAY RESULT FROM THE USE OF THE MATERIALS OR INFORMATION, WHETHER OR NOT THE RECIPIENT OF MATERIALS HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGE. Skyworks products are not intended for use in medical, lifesaving or life-sustaining applications, or other equipment in which the failure of the Skyworks products could lead to personal injury, death, physical or environmental damage. Skyworks customers using or selling Skyworks products for use in such applications do so at their own risk and agree to fully indemnify Skyworks for any damages resulting from such improper use or sale. Customers are responsible for their products and applications using Skyworks products, which may deviate from published specifications as a result of design defects, errors, or operation of products outside of published parameters or design specifications. Customers should include design and operating safeguards to minimize these and other risks. Skyworks assumes no liability for applications assistance, customer product design, or damage to any equipment resulting from the use of Skyworks products outside of stated published specifications or parameters. Skyworks and the Skyworks symbol are trademarks or registered trademarks of Skyworks Solutions, Inc., in the United States and other countries. Third-party brands and names are for identification purposes only, and are the property of their respective owners. Additional information, including relevant terms and conditions, posted at www.skyworksinc.com, are incorporated by reference. Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com 16 January 20, 2016 • Skyworks Proprietary and Confidential Information • Products and Product Information are Subject to Change Without Notice • 203284E