RKE-0505S/H

●
●
●
●
Features
Unregulated
Converter
●
●
ECONOLINE
Low Cost 1W Converter
4kVDC / 1 sec High Isolation
Low Output Ripple
Wide Operating Temperature Range of
-40°C to +85°C
Industry Standard Pinout
UL Certified
DC/DC-Converter
with 3 year Warranty
Selection Guide
Part
Number
SIP 7
Input
Voltage
(VDC)
Output
Voltage
(VDC)
Output
Current
(mA)
Efficiency
(%)
Max
Capacitive
Load (1)
5
5
200
70
1200µf
RKE-0505S/H
1 Watt
SIP7 Single
Output
Specifications (measured at TA = 25°C, nominal input voltage, full load and after warm-up)
Input Voltage Range
±10%
Output Voltage Accuracy
-2% typ. / ±5% max.
Efficiency (@ Full Load)
65% min. / 70% typ.
Operating Frequency
50kHz min / 65kHz typ. / 105kHz
Output Ripple & Noise
55mVp-p typ. / 100mVp-p max.
Line Voltage Regulation
Low Line to High Line @ max. Load
1.2% typ. of 1% Vin
Load Voltage Regulation
(10% to 100% Load)
12% typ. / 15% max.
Isolation Voltage
(tested for 1 second*)
4kVDC
(rated for 1 minute*)
3kVDC
Isolation Capacitance
75pF max.
Isolation Resistance
Viso=500V
RoHS
2011/65/EU
6/6
1GΩ min.
Short Circuit Protection
E-358085
1 sec.
Operating Temperature Range
-40°C to +85°C
Storage Temperature Range
-55°C to 125°C
Humidity
UL-60950-1 Certified
95% max.
Size
19.60mm x 10.20mm x 7.05mm
Weight
RKE-0505S/H
2.7g
MTBF (25°C)
using MIL-HDBK 217F
850 x 10³ hours
(85°C)
using MIL-HDBK 217F
123 x 10³ hours
Certification
UL General Safety
Report: E358085-A4
UL60950-1
*Any data referred to in this datasheet are of indicative nature and based on our practical experience only. For further details, please refer
to our Application Notes.
(Ambient Temperature)
Maximum capacitive load is defined as the capacitive load that will allow start up in under 1second without
damage to the converter.
100
Tolerance Envelopes
Output Voltage
+15%
+12%
+5%
-2%
VNOM
-5%
Typical Load Line
Output Power (%)
Notes
Note1:
Derating-Graph
Safe Operating Area
30
0
-40
0
50
Operating Temperature °C
10%
50%
125
100%
+Vout load current (%)
E-60
100
85
Refer to Application Notes
REV: 1/2015
www.recom-power.com
ECONOLINE
RKE-0505S/H
DC/DC-Converter
Typical Characteristics
Efficiency vs Load
Deviation vs Load
Deviation from Nominal %
100
Efficiency %
80
60
40
20
0
0
20
60
40
80
30
25
20
15
10
5
0
-5
0
20
40
80
60
100
Load %
100
Load %
Package Style and Pinning (mm)
RECOM
RKE-0505S/H
xxxx
10.20
4.10
1
2
Pin Connections
RKE-0505S/H
Pin #
0.51 typ.
Pb
1
7
5
0.25 typ.
0.51 typ.
RKE
7.05
Single
+Vin
2
-Vin
5
-Vout
7
+Vout
XX.X ± 0.5 mm
XX.XX ± 0.25 mm
Recommended Footprint Details
Top View
19.60
Bottom View
1.27
1
2
5
7
7.05
1.00 ø+0.15/–0
2.54
2.54
2.0
2.54*6=15.24
2.54
The product information and specifications are subject to change without prior notice. RECOM products are not authorized for use in safety-critical applications (such as life support) without RECOM’s explicit
written consent. A safety-critical application is defined as an application where a failure of a RECOM product may reasonably be expected to endanger or cause loss of life, inflict bodily harm or damage property. The buyer
shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized use of RECOM products in such safety-critical applications.
www.recom-power.com
REV: 1/2015
E-61