RAM - Recom International Power Gmbh

Features
●
●
●
●
●
●
Unregulated
Converters
ECONOLINE
1:1 Input Range
Efficiency up to 80%
3kVDC and 4kVDC Isolation Option
Approved for Medical Applications
-40°C to +100°C Operating Temperature Range
Continuous Short Circuit Protection
DC/DC-Converter
Selection Guide
Part
Number
SMD
Isolation
Voltage
(kV)
Input
Voltage
(VDC)
Output
Voltage
(VDC)
Output
Current
(mA)
Efficiency
(typ.)
Capacitive
Load
(max.)
RAM-0505S*
3
5
5
200
78%
1000µF
RAM-1205S*
3
12
5
200
80%
1000µF
RAM-2405S*
3
24
5
200
80%
1000µF
1 Watt SMD
Single Output
* add Suffix “/H“ for Isolation 4kVDC/1min. e.g. RAM-0505S/H
* add Suffix “-R“ for tape&reel packing e.g. RAM-1205S-R or RAM-2405S/H-R
Specifications (measured at TA = 25°C, nominal input voltage and rated output current unless otherwise specified)
Input Voltage Range
±10%
Output Voltage Accuracy
-1% typ., ±5% max.
Line Voltage Regulation
(low line to high line at max. load)
Load Voltage Regulation
(10% to 100% full load)
Output Ripple and Noise (20MHz BW limited)
10% typ., 15% max.
50mVp-p typ., 100mVp-p max.
Operating Frequency (Vin=nominal input)
20kHz min. / 50kHz typ. / 90kHz max.
Efficiency
see Selection Guide
Minimum Load = 0%
(tested for 1 second)
Isolation Voltage
3750 VDC
(rated for 1 minute**)
3000 VDC
H-Suffix
(tested for 1 second)
5000 VDC
H-Suffix
(rated for 1 minute**)
4pF typ., 10pF max.
Isolation Resistance
(Viso=500V)
15GΩ min.
Short-Circuit Protection
continuous
Operating Temperature Range
-40°C to +100°C
Storage Temperature
-55°C to +125°C
Reflow Temperature
RoHS compliant
Vapor Phase Process
(for more details see Application Notes)
Derating-Graph
(Ambient Temperature)
245°C (30 sec.), Peak 255°C (5sec.) max.
230°C (90 sec.) max.
Relative Humidity
100
95% RH
80
Packing Quantity
All Types
27 pcs per Tube
60
All Types
500 pcs per Reel
Detailed Information see
Application Notes chapter "MTBF"
using MIL-HDBK 217F
4780 x 10³ hours
using MIL-HDBK 217F
1310 x 10³ hours
Certifications
EN Medical Safety
Report: MDD1112018 + RM1112018
IEC/EN 60601-1 3rd Edition
Medical Report + ISO14971 Risk Assessment
EN General Safety
Report: SPCLVD1112018
Output Power (%)
1.3g
Package Weight
}
RAM
4000 VDC
Isolation Capacitance
MTBF (+85°C)
EN-60601-1 Certified
EN-60950-1 Certified
Specifications valid for 10% minimum load only
Isolation Voltage
MTBF (+25°C)
RoHS
2011/65/EU
6/6
1.2% typ., 1.5% max.
40
Safe Operating Area
20
0
-40
0
50
100
150
Operating Temperature °C
EN60950-1, 2nd Edition
**Any data referred to in this datasheet are of indicative nature and based on our practical experience only. For further details, please refer
to our Application Notes.
Refer to Application Notes
E-62
REV: 0/2015
www.recom-power.com
RAM Series
ECONOLINE
DC/DC-Converter
Typical Characteristics
RAM-xx05S
Tolerance Envelope
+10%
Efficiency / Load
+5%
ad Line
Output Voltage
V Nom.
+5%
100
– 1%
80
– 5%
60
1205
Efficiency %
50%
0505
20
2405
40
10%
Deviation / Load
25
Deviation from Nominal (%)
Typical L
o
20
0
100%
0% 20%
40%
60%
Total Output current (%)
80%
100%
0505
1205
15
10
5
0
2405
-5
-10
0% 20%
40%
60%
Total Output current (%)
80%
100%
Output Load Current (%)
Notes
Note 1: Maximum capacitive load is defined as the capacitive load tha will allow start up in under 1 second without damage to the converter
EMC Filtering - Suggestion for EN55022 Class B
470pF/6kVDC
Input
Voltage
DC
Input
+
Output
C1
5V
10µF
12V
4.7µF
24V
22µF
RAM
DC
GND
Inductance/
Capacitance (C1)
GND
Package Style and Pinning
8.70
18.00
6.70
4.05 max.
Pin Connections
Pin #
Function
10.65
1.27x13
1
28 27
17 16 15
TOP VIEW
Pb
1 2
12 13 14
-Vin
12
-Vout
13
+Vout
14~17
NC
27,28
NC
NC = No Connection
1.27
11.80
RECOM
RAM-xx05S
9.00
1.40
Recommended Footprint Details
+Vin
2
Unit:
Tolerance:
mm
± 0.25 mm
0.90
13*1.27= 16.51
The product information and specifications are subject to change without prior notice. RECOM products are not authorized for use in safety-critical applications (such as life support) without RECOM’s explicit
written consent. A safety-critical application is defined as an application where a failure of a RECOM product may reasonably be expected to endanger or cause loss of life, inflict bodily harm or damage property. The buyer
shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized use of RECOM products in such safety-critical applications.
www.recom-power.com
REV: 0/2015
E-63