RxxP2xx/R - recom

Features
Unregulated
Converters
Description
●
●
●
●
●
●
●
●
●
UL/CSA and EN Safety certified
EN-61010 for Test, Measurement and Lab Use
EN-60601 for Medical Applications
Reinforced Isolation 6.4kVDC or 8kVDC
Optional Continuous Short Circuit Protected
Compact SIP7 Package
Efficiency to 88%
Very Low Isolation Capacitance
/X2 Version with >9mm Input/Output Clearance
ECONOLINE
DC/DC-Converter
with 3 year Warranty
2 Watt
SIP 7 Single &
Dual Output
The RxxP2xxS_D Series of DC/DC Converters are certified to UL/CSA-60950 and UL/CSA
60601. This makes them ideal for medical and safety applications where approved or reinforced
isolation is required. The reinforced versions are also EN61010-1 certified for Lab Equipment.
The /X2 version has an input/output clearance of more than 9mm.
Selection Guide
Part
Number
SIP 7
Reinforced
Isolation
(kVDC)
Input
Voltage
(VDC)
Output
Voltage
(VDC)
Output
Current
(mA)
Efficiency
Std
(%)
Max
Capacitive
Load(1)
RxxP23.3S
/R6.4 & /R8
5, 12, 15, 24
3.3
600
72-78
3300µF
RxxP205S
/R6.4 & /R8
5, 12, 15, 24
5
400
79-84
1200µF
RxxP209S
/R6.4 & /R8
5, 12, 15, 24
9
222
80-87
1200µF
RxxP212S
/R6.4 & /R8
5, 12, 15, 24
12
167
80-87
680µF
RxxP215S
/R6.4 & /R8
5, 12, 15, 24
15
132
80-88
680µF
RxxP23.3D
/R6.4 & /R8
5, 12, 15, 24
±3.3
±300
73-80
±1500µF
RxxP205D
/R6.4 & /R8
5, 12, 15, 24
±5
±200
79-85
±470µF
RxxP209D
/R6.4 & /R8
5, 12, 15, 24
±9
±111
80-87
±470µF
RxxP212D
/R6.4 & /R8
5, 12, 15, 24
±12
±85
80-87
±330µF
RxxP215D
/R6.4 & /R8
5, 12, 15, 24
±15
±66
80-88
±330µF
xx = Input Voltage. Other input and output voltage combinations available on request.
* add Suffix “P” for Continuous Short Circuit Protection, e.g. R05P205S/P, R05P205D/P
* add Suffix “/X2” for single output with alternative pinout, e.g. R05P205S/X2, R05P205S/P/X2
* add Suffix “/R6.4” or “/R8” for Reinforced Isolation, e.g. R05P205D/R6.4, R05P205S/P/X2/R8
RoHS
2011/65/EU
6/6
E-314885
EN-60950-1 Certified
EN-60601-1 Certified
UL/CSA 60950-1 Certified
UL-60601 Certified
EN-61010-1 Certified
IEC-60601-1 CB Report
RxxP2xx/R
Specifications (measured at TA = 25°C, nominal input voltage, full load and after warm-up)
Input Voltage Range
±10%
Output Voltage Accuracy
±5%
Line Voltage Regulation
1.2%/1% of Vin typ.
Load Voltage Regulation
3.3, 5V output types
15% max.
(10% to 100% full load)
other output types
10% max.
Output Ripple and Noise (20MHz BW)
Derating-Graph
(Ambient Temperature)
200mVp-p max.
Operating Frequency
20kHz min. / 50kHz typ. / 85kHz max.
65% min. / 80% max.
100
Minimum Load = 0%
Specifications valid for 10% minimum load only.
80
Isolation Voltage
Isolation Capacitance
/R6.4 (tested for 1 second)
6400VDC
(rated for 1 minute**)
3200VAC / 60Hz
/R8 (tested for 1 second)
8000VDC
(rated for 1 minute**)
4000VAC / 60Hz
1.5pF min. / 10pF max.
Isolation Resistance
15 GΩ min.
Short Circuit Protection
Output Power (%)
Efficiency at Full Load
60
40
Safe Operating Area
20
0
-40
0
50
85
Operating Temperature °C
100
1 Second
P-Suffix
Continuous
continued on next page
**Any data referred to in this datasheet are of indicative nature and based on our practical experience only. For further details, please refer
to our Application Notes.
Refer to Application Notes
E-100
REV: 1/2015
www.recom-power.com
150
RxxP2xxS_D
/Rx Series
ECONOLINE
DC/DC-Converter
Specifications (measured at TA = 25°C, nominal input voltage, full load and after warm-up)
Operating Temperature Range (free air convection)
-40°C to +85°C (see Graph)
Storage Temperature Range
-55°C to +125°C
Relative Humidity
95% RH
Package Weight
4.3g
Packing Quantity
25 pcs per Tube
Potting Material
MTBF (+25°C)
Detailed Information see
Application Notes chapter "MTBF"
.
(+85°C)
Reinforced
Reinforced Isolation
Transformer Creepage
Transformer Clearance
PCB Creepage & Clearance
Certifications
Measurement, Control and Laboratory Use Safety
CSA General Safety
}
/R6.4 Types
/R6.4 Types
/R6.4 Types
Report: T1301251-313
Report: 2207629
UL/cUL Medical Safety
CSA Medical Safety
EN General Safety
CB/EN Medical Safety
ANSI/AAMI Medical Safety
Report: 314885-A5
Report: 2207629
Report: SPCLVD1310079-1
Report: CA-10169-A1-UL
Report: E314885-A5
Silicone Rubber Compound (UL94V-0)
1154 x 103 hours
168 x 103 hours
5.5 mm min.
5.5 mm min.
4.6 mm min.
EN 61010-1 : 2010
UL 60950-1 1st Edition
C22.2 No. 60950-1-03
UL60601-1 1st Edition
CAN/CSA-22.2 No 601.1-M90
EN60950-1 : 2006
IEC/EN 60601-1 3rd Edition
ES60601-1 3rd Edition
Notes
Note 1
Maximum capacitive load is defined as the capacitive load that will allow start up in under 1 second without damage to the converter.
Tolerance Envelope
RxxP2xx/R
+10%
Typical L
o
+5%
V Nom.
+5%
ad Line
– 1.5%
Output Voltage
– 5%
10%
50%
100%
Output Load Current (%)
www.recom-power.com
REV: 1/2015
E-101
RxxP2xxS_D
/Rx Series
ECONOLINE
DC/DC-Converter
Typical Characteristics
RxxP205S/R6.4
RxxP205S/R8
Deviation / Load
Efficiency / Load
25.000
100
R05P205S/R6.4
20.000
Deviation from Nominal (%)
R12P205S/R6.4
80
60
R24P205S/R6.4
Efficiency %
40
20
0
0%
20%
40%
80%
60%
100%
10.000
5.000
0.000
-5.000
-10.000
Total Output current (%)
RxxP2xx/R
R12P205S/R6.4
R24P205S/R6.4
15.000
R05P205S/R6.4
0% 20%
40%
60%
Total Output current (%)
80%
100%
RxxP205D/R6.4
RxxP205D/R8
Efficiency / Load
Deviation / Load
100
80
25.000
R05P205D/R6.4
20.000
Deviation from Nominal (%)
R12P205D/R6.4
60
Efficiency %
40
R24P205D/R6.4
20
0
0%
20%
40%
60%
80%
100%
15.000
10.000
R24P205D/R6.4
5.000
0.000
-5.000
-10.000
Total Output current (%)
E-102
R12P205D/R6.4
REV: 1/2015
R05P205D/R6.4
0% 20%
40%
60%
Total Output current (%)
80%
100%
www.recom-power.com
RxxP2xxS_D
/Rx Series
ECONOLINE
DC/DC-Converter
Package Style and Pinning (mm)
7 PIN SIP Package
9.8
12.5
4.1
RECOM
R05P205D/R6.4 or
R05P205D/R8
****
7.62
clearance
0.5
Bottom View
Single Output
RECOM
RxxP2xxD/R6.4 or
RxxP2xxD/R8
****
RECOM
RxxP2xxS/R6.4 or
RxxP2xxS/R8
****
1 2
0.5
1 2
5 6 7
Recommended Footprint Details
RECOM
RxxP2xxS/X2/R6.4 or
RxxP2xxS/X2/R8
****
0.25
1 2
2.4
1.9
15.24
2.54
Pin #
1
2
5
6
7
0.25
2.4
1.9
10.16
clearance
Pin Connections
2.54
/X2 Top View
Single
+Vin
-Vin
–Vout
No Pin
+Vout
Dual
+Vin
-Vin
–Vout
Com
+Vout
/X2
+Vin
-Vin
No Pin
-Vout
+Vout
XX.X ± 0.5 mm
XX.XX ± 0.25 mm
The product information and specifications are subject to change without prior notice. RECOM products are not authorized for use in safety-critical applications (such as life support) without RECOM’s explicit
written consent. A safety-critical application is defined as an application where a failure of a RECOM product may reasonably be expected to endanger or cause loss of life, inflict bodily harm or damage property. The buyer
shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized use of RECOM products in such safety-critical applications.
www.recom-power.com
REV: 1/2015
E-103
RxxP2xx/R
/X2 Bottom View
6 7
Top View
1.00ø+0.15/–0
2.54
19.5
7
5
/X2 Single Output
1.00ø+0.15/–0
2.54
19.5
Dual Output