RV-S_D/R - recom

●
●
●
●
●
●
●
●
Features
Unregulated
Converters
UL/CSA and EN-60950-1 Safety certified
EN-61010 for Test, Measurement and Lab Use
UL/CSA and EN-60601 for Medical Applications
6.4kVDC or 8kV Reinforced Isolation
Optional Continuous Short Circuit Protection
Efficiency to 88%
Space Saving „Skinny DIP“ Package
Very Low Isolation Capacitance
ECONOLINE
DC/DC-Converter
with 3 year Warranty
2 Watt DIP24
Miniature
Single & Dual
Output
Very high isolation in a small size are the main features of this miniature DIP24 converter,
ideal for highly sophisticated industrial, test and measurement and medical designs where
board space is at a premium.
Description
Selection Guide
Part
Number
SIP 7
Reinforced
Isolation
(kVDC)
Input
Voltage
(VDC)
Output
Voltage
(VDC)
Output
Current
(mA)
Efficiency
Std
(%)
Max
Capacitive
Load(1)
RV-xx3.3S
/R6.4 & /R8
3.3, 5, 12, 15, 24
3.3
600
70-78
3300µF
RV-xx05S
/R6.4 & /R8
3.3, 5, 12, 15, 24
5
400
76-80
1200µF
RV-xx09S
/R6.4 & /R8
3.3, 5, 12, 15, 24
9
222
78-85
1200µF
RV-xx12S
/R6.4 & /R8
3.3, 5, 12, 15, 24
12
167
78-85
680µF
RV-xx15S
/R6.4 & /R8
3.3, 5, 12, 15, 24
15
132
78-88
680µF
RV-xx3.3D
/R6.4 & /R8
3.3, 5, 12, 15, 24
±3.3
±300
70-78
±1500µF
RV-xx05D
/R6.4 & /R8
3.3, 5, 12, 15, 24
±5
±200
75-82
±470µF
RV-xx09D
/R6.4 & /R8
3.3, 5, 12, 15, 24
±9
±111
76-84
±470µF
RV-xx12D
/R6.4 & /R8
3.3, 5, 12, 15, 24
±12
±85
78-86
±220µF
RV-xx15D
/R6.4 & /R8
3.3, 5, 12, 15, 24
±15
±66
78-86
±220µF
xx = Input Voltage. Other input and output voltage combinations available on request.
* add Suffix “P” for Continuous Short Circuit Protection, e.g. RV-0505S/P, RV-0505D/P
* add Suffix “/R6.4”or “/R8” for Reinforced Isolation, e.g. RV-0505S/R6.4, RV-0505D/P/R8
For functional isolation, please refer to RV sereis datasheet
RoHS
2011/65/EU
6/6
E-314885
EN-60950-1 Certified
EN-60601-1 Certified
UL/CSA 60950-1 Certified
UL-60601-1 Certified
EN-61010-1 Certified
IEC-60601-1 CB Report
RV/R
Specifications (measured at TA = 25°C, nominal input voltage, full load and after warm-up)
Input Voltage Range
±10%
Output Voltage Accuracy
±5%
Line Voltage Regulation
Load Voltage Regulation
(10% to 100% full load)
1.2%/1% of Vin typ.
20% max.
15% max.
10% max.
3.3V output types
5V output type
9V, 12V, 15V, 24V output types
Output Ripple and Noise (20MHz limited)
(Ambient Temperature)
200mVp-p max.
20kHz min. / 50kHz typ. / 85kHz max.
Efficiency at Full Load
70% min. / 75% typ.
Minimum Load = 0%
Isolation Voltage
Specifications valid for 10% minimum load only.
(tested for 1 second)
6400VDC
(rated for 1 minute**)
3200VAC / 60Hz
(tested for 1 second)
8000VDC
(rated for 1 minute**)
4000VAC / 60Hz
/R6.4
/R8
Isolation Capacitance
2pF min. / 12pF max.
Isolation Resistance
15 GΩ min.
Short Circuit Protection
P-Suffix
Operating Temperature Range (free air convection)
1 Second
Continuous
-40°C to +85°C (see Graph)
100
80
Output Power (%)
Operating Frequency
Storage Temperature Range
Derating-Graph
60
40
Safe Operating Area
20
0
-40
0
50
85
Operating Temperature °C
100
150
**Any data referred to in this datasheet are of indicative nature
and based on our practical experience only. For further details,
please refer to our Application Notes.
-55°C to +125°C
continuned on next page
Refer to Application Notes
www.recom-power.com
REV: 0/2015
E-113
RV/R
Series
ECONOLINE
DC/DC-Converter
Specifications (measured at TA = 25°C, nominal input voltage, full load and after warm-up)
Relative Humidity
95% RH
Package Weight
9g
Packing Quantity
15 pcs per Tube
MTBF (+25°C)
(+85°C)
}
Detailed Information see
Application Notes chapter "MTBF"
Reinforced Isolation
using MIL-HDBK 217F
1154 x 103 hours
using MIL-HDBK 217F
168 x 103 hours
Transformer Creepage
/R6.4 Types
5.5 mm min.
Transformer Clearance
/R6.4 Types
5.5 mm min.
PCB Creepage & Clearance
/R6.4 Types
4.8 mm min.
Certifications
Measurement, Control and Laboratory Use Safety
Report: T1301251-313
CSA General Safety
EN 61010-1 : 2010
UL 60950-1 1st Edition
C22.2 No. 60950-1-03
UL/cUL Medical Safety
Report: E314885-A4
CSA Medical Safety
Report: 2207629
EN General Safety
Report: SPCLVD1310079-1
EN Medical Safety
Report: CA-10168-A1-UL
UL60601-1 3rd Edition
CAN/CSA-22.2 No 601.1-M90
EN60950-1 : 2006
IEC/EN 60601-1 3rd Edition
Notes
Maximum capacitive load is defined as the capacitive load that will allow start up in under 1 second without damage to the converter.
Tolerance Envelope
+10%
Typica
l
+6%
V Nom.
Load
Line
Output Voltage
RV /R
Note 1
10%
50%
+5%
– 2.5%
– 5%
100%
Output Load Current (%)
E-114
REV: 0/2015
www.recom-power.com
RV/R
Series
ECONOLINE
DC/DC-Converter
Typical Characteristics
RV-xx05S/R6.4
RV-xx05S/R8
Deviation / Load
Efficiency / Load
25.000
100
RV-1205S/R6.4
20.000
60
RV-0505S/R6.4
40
Efficiency %
Deviation from Nominal (%)
80
RV-2405S/R6.4
20
0
0%
20%
40%
60%
80%
15.000
RV-0505S/R6.4
10.000
RV-2405S/R6.4
5.000
0.000
-5.000
-10.000
100%
Total Output current (%)
RV-1205S/R6.4
0% 20%
40%
60%
Total Output current (%)
80%
100%
Deviation / Load
Efficiency / Load
100
25.000
RV-1205D/R6.4
20.000
60
Efficiency %
Deviation from Nominal (%)
80
RV-0505D/R6.4
40
RV-2405D/R6.4
20
0
0%
20%
40%
60%
80%
15.000
10.000
5.000
0.000
-5.000
-10.000
100%
Total Output current (%)
www.recom-power.com
RV/R
RV-xx05D/R6.4
RV-xx05D/R8
REV: 0/2015
RV-0505D/R6.4
RV-2405D/R6.4
RV-1205D/R6.4
0% 20%
40%
60%
Total Output current (%)
80%
100%
E-115
RV/R
Series
ECONOLINE
DC/DC-Converter
Package Style and Pinning (mm)
24 PIN DIP Miniature Package Style
Single & Dual Output
14.40
2.54 x 11
17 16 15 14 13
24 23
RECOM
RV-0505D/R6.4
11.40
4.10
0.60
0.25
2.2
15.24
0.50±0.05
****
16.95 max.
8 9 10 11 12
1 2
Recommended Footprint Details
32.35
1 2
1.0ø+0.15/–0
2.54
8 9 10 11 12
24 23
2.54
Pin #
Dual
1
+Vin
2
-Vin
2
-Vin
NC
8, 17
-Vout
10, 15
-Vout
9, 11, 14,16, 23, 24
NC
12 & 13
+Vout
10 & 15
Com
NC
12, 13
+Vout
16, 17, 23, 24
Top View
Single
+Vin
8, 9, 11, 14
17 16 15 14 13
Pin Connections
1
Pin #
Bottom View
16.10
Pin Connections
NC = No Connection
NC = No Connection
RV /R
XX.X ± 0.5 mm
XX.XX ± 0.25 mm
The product information and specifications are subject to change without prior notice. RECOM products are not authorized for use in safety-critical applications (such as life support) without RECOM’s explicit
written consent. A safety-critical application is defined as an application where a failure of a RECOM product may reasonably be expected to endanger or cause loss of life, inflict bodily harm or damage property. The buyer
shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized use of RECOM products in such safety-critical applications.
E-116
REV: 0/2015
www.recom-power.com