● ● ● ● ● ● ● ● Features Unregulated Converters UL/CSA and EN-60950-1 Safety certified EN-61010 for Test, Measurement and Lab Use UL/CSA and EN-60601 for Medical Applications 6.4kVDC or 8kV Reinforced Isolation Optional Continuous Short Circuit Protection Efficiency to 88% Space Saving „Skinny DIP“ Package Very Low Isolation Capacitance ECONOLINE DC/DC-Converter with 3 year Warranty 2 Watt DIP24 Miniature Single & Dual Output Very high isolation in a small size are the main features of this miniature DIP24 converter, ideal for highly sophisticated industrial, test and measurement and medical designs where board space is at a premium. Description Selection Guide Part Number SIP 7 Reinforced Isolation (kVDC) Input Voltage (VDC) Output Voltage (VDC) Output Current (mA) Efficiency Std (%) Max Capacitive Load(1) RV-xx3.3S /R6.4 & /R8 3.3, 5, 12, 15, 24 3.3 600 70-78 3300µF RV-xx05S /R6.4 & /R8 3.3, 5, 12, 15, 24 5 400 76-80 1200µF RV-xx09S /R6.4 & /R8 3.3, 5, 12, 15, 24 9 222 78-85 1200µF RV-xx12S /R6.4 & /R8 3.3, 5, 12, 15, 24 12 167 78-85 680µF RV-xx15S /R6.4 & /R8 3.3, 5, 12, 15, 24 15 132 78-88 680µF RV-xx3.3D /R6.4 & /R8 3.3, 5, 12, 15, 24 ±3.3 ±300 70-78 ±1500µF RV-xx05D /R6.4 & /R8 3.3, 5, 12, 15, 24 ±5 ±200 75-82 ±470µF RV-xx09D /R6.4 & /R8 3.3, 5, 12, 15, 24 ±9 ±111 76-84 ±470µF RV-xx12D /R6.4 & /R8 3.3, 5, 12, 15, 24 ±12 ±85 78-86 ±220µF RV-xx15D /R6.4 & /R8 3.3, 5, 12, 15, 24 ±15 ±66 78-86 ±220µF xx = Input Voltage. Other input and output voltage combinations available on request. * add Suffix “P” for Continuous Short Circuit Protection, e.g. RV-0505S/P, RV-0505D/P * add Suffix “/R6.4”or “/R8” for Reinforced Isolation, e.g. RV-0505S/R6.4, RV-0505D/P/R8 For functional isolation, please refer to RV sereis datasheet RoHS 2011/65/EU 6/6 E-314885 EN-60950-1 Certified EN-60601-1 Certified UL/CSA 60950-1 Certified UL-60601-1 Certified EN-61010-1 Certified IEC-60601-1 CB Report RV/R Specifications (measured at TA = 25°C, nominal input voltage, full load and after warm-up) Input Voltage Range ±10% Output Voltage Accuracy ±5% Line Voltage Regulation Load Voltage Regulation (10% to 100% full load) 1.2%/1% of Vin typ. 20% max. 15% max. 10% max. 3.3V output types 5V output type 9V, 12V, 15V, 24V output types Output Ripple and Noise (20MHz limited) (Ambient Temperature) 200mVp-p max. 20kHz min. / 50kHz typ. / 85kHz max. Efficiency at Full Load 70% min. / 75% typ. Minimum Load = 0% Isolation Voltage Specifications valid for 10% minimum load only. (tested for 1 second) 6400VDC (rated for 1 minute**) 3200VAC / 60Hz (tested for 1 second) 8000VDC (rated for 1 minute**) 4000VAC / 60Hz /R6.4 /R8 Isolation Capacitance 2pF min. / 12pF max. Isolation Resistance 15 GΩ min. Short Circuit Protection P-Suffix Operating Temperature Range (free air convection) 1 Second Continuous -40°C to +85°C (see Graph) 100 80 Output Power (%) Operating Frequency Storage Temperature Range Derating-Graph 60 40 Safe Operating Area 20 0 -40 0 50 85 Operating Temperature °C 100 150 **Any data referred to in this datasheet are of indicative nature and based on our practical experience only. For further details, please refer to our Application Notes. -55°C to +125°C continuned on next page Refer to Application Notes www.recom-power.com REV: 0/2015 E-113 RV/R Series ECONOLINE DC/DC-Converter Specifications (measured at TA = 25°C, nominal input voltage, full load and after warm-up) Relative Humidity 95% RH Package Weight 9g Packing Quantity 15 pcs per Tube MTBF (+25°C) (+85°C) } Detailed Information see Application Notes chapter "MTBF" Reinforced Isolation using MIL-HDBK 217F 1154 x 103 hours using MIL-HDBK 217F 168 x 103 hours Transformer Creepage /R6.4 Types 5.5 mm min. Transformer Clearance /R6.4 Types 5.5 mm min. PCB Creepage & Clearance /R6.4 Types 4.8 mm min. Certifications Measurement, Control and Laboratory Use Safety Report: T1301251-313 CSA General Safety EN 61010-1 : 2010 UL 60950-1 1st Edition C22.2 No. 60950-1-03 UL/cUL Medical Safety Report: E314885-A4 CSA Medical Safety Report: 2207629 EN General Safety Report: SPCLVD1310079-1 EN Medical Safety Report: CA-10168-A1-UL UL60601-1 3rd Edition CAN/CSA-22.2 No 601.1-M90 EN60950-1 : 2006 IEC/EN 60601-1 3rd Edition Notes Maximum capacitive load is defined as the capacitive load that will allow start up in under 1 second without damage to the converter. Tolerance Envelope +10% Typica l +6% V Nom. Load Line Output Voltage RV /R Note 1 10% 50% +5% 2.5% 5% 100% Output Load Current (%) E-114 REV: 0/2015 www.recom-power.com RV/R Series ECONOLINE DC/DC-Converter Typical Characteristics RV-xx05S/R6.4 RV-xx05S/R8 Deviation / Load Efficiency / Load 25.000 100 RV-1205S/R6.4 20.000 60 RV-0505S/R6.4 40 Efficiency % Deviation from Nominal (%) 80 RV-2405S/R6.4 20 0 0% 20% 40% 60% 80% 15.000 RV-0505S/R6.4 10.000 RV-2405S/R6.4 5.000 0.000 -5.000 -10.000 100% Total Output current (%) RV-1205S/R6.4 0% 20% 40% 60% Total Output current (%) 80% 100% Deviation / Load Efficiency / Load 100 25.000 RV-1205D/R6.4 20.000 60 Efficiency % Deviation from Nominal (%) 80 RV-0505D/R6.4 40 RV-2405D/R6.4 20 0 0% 20% 40% 60% 80% 15.000 10.000 5.000 0.000 -5.000 -10.000 100% Total Output current (%) www.recom-power.com RV/R RV-xx05D/R6.4 RV-xx05D/R8 REV: 0/2015 RV-0505D/R6.4 RV-2405D/R6.4 RV-1205D/R6.4 0% 20% 40% 60% Total Output current (%) 80% 100% E-115 RV/R Series ECONOLINE DC/DC-Converter Package Style and Pinning (mm) 24 PIN DIP Miniature Package Style Single & Dual Output 14.40 2.54 x 11 17 16 15 14 13 24 23 RECOM RV-0505D/R6.4 11.40 4.10 0.60 0.25 2.2 15.24 0.50±0.05 **** 16.95 max. 8 9 10 11 12 1 2 Recommended Footprint Details 32.35 1 2 1.0ø+0.15/0 2.54 8 9 10 11 12 24 23 2.54 Pin # Dual 1 +Vin 2 -Vin 2 -Vin NC 8, 17 -Vout 10, 15 -Vout 9, 11, 14,16, 23, 24 NC 12 & 13 +Vout 10 & 15 Com NC 12, 13 +Vout 16, 17, 23, 24 Top View Single +Vin 8, 9, 11, 14 17 16 15 14 13 Pin Connections 1 Pin # Bottom View 16.10 Pin Connections NC = No Connection NC = No Connection RV /R XX.X ± 0.5 mm XX.XX ± 0.25 mm The product information and specifications are subject to change without prior notice. RECOM products are not authorized for use in safety-critical applications (such as life support) without RECOM’s explicit written consent. A safety-critical application is defined as an application where a failure of a RECOM product may reasonably be expected to endanger or cause loss of life, inflict bodily harm or damage property. The buyer shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized use of RECOM products in such safety-critical applications. E-116 REV: 0/2015 www.recom-power.com