RP20 (F) - Recom International Power Gmbh

●
●
●
●
●
●
●
●
Features
Description
2:1 Wide Input Voltage Range
20 Watts Output Power
1.6kVDC Isolation
UL Certified
Fixed Operating Frequency
Six-Sided Continuous Shield
Standard 50.8 x25.4x10.2mm Package
Efficiency to 89%
The RP20-F series DC/DC converters are certified to UL 60950-1 and to cUL 609501. This makes them ideal for all telecom and industrial applications where approved
safety standards are required. The industry standard 2” x 1” package meets military
standards for thermal shock and vibration tolerance.
Selection Guide 12V, 24V and 48V Input Types
POWERLINE
DC/DC-Converter
with 3 year Warranty
20 Watt
2” x 1”
Single &
Dual Output
Input (4) Efficiency (5) Capacitive (6)
Current
Load max.
mA
%
Part Number
Input
Range
VDC
Output
Voltage
VDC
Output
Current
mA
RP20-123.3SF
9-18
3.3
5000
1719
84
13000µF
RP20-1205SF
9-18
5
4000
2008
87
6800µF
RP20-1212SF
9-18
12
1670
2062
85
2200µF
RP20-1215SF
9-18
15
1330
2052
85
755µF
RP20-243.3SF
18-36
3.3
5000
838
86
13000µF
RP20-2405SF
18-36
5
4000
980
89
6800µF
RP20-2412SF
18-36
12
1670
1006
87
2200µF
RP20-2415SF
18-36
15
1330
1002
87
755µF
RP20-483.3SF
36-75
3.3
5000
414
87
13000µF
RP20-4805SF
36-75
5
4000
490
89
6800µF
RP20-4812SF
36-75
12
1670
497
88
2200µF
RP20-4815SF
36-75
15
1330
500
87
755µF
RP20-1212DF
9-18
±12
±833
2032
86
±680µF
RP20-1215DF
9-18
±15
±667
2034
86
±450µF
RP20-2412DF
18-36
±12
±833
1004
87
±680µF
Derating-Graph
RP20-2415DF
18-36
±15
±667
1005
87
±450µF
(Ambient Temperature)
RP20-4812DF
36-75
±12
±833
496
88
±680µF
RP20-4815DF
36-75
±15
±667
502
87
±450µF
RoHS
2011/65/EU
6/6
UL-60950-1 Certified
E196683
RP20-F
125
RP20-2405SF
Ordering Examples
Output Power (%)
100
* no suffix for CTRL function with Positive Logic (1=ON, 0=OFF), this is standard
* add /N for CTRL function with Negative Logic (0=ON, 1=OFF)
* add suffix -HC for premounted heatsink and clips
75
50
Natural Convection
25
0
-40 -25 -10 0
50 60
80 90 100
70
Ambient Temperature Range (°C)
RP20-2405SF = 24V Input, 5V Output, Positive Logic CTRL pin fitted
RP20-4812DF/N-HC = 48V Input, ±12V Output, Negative Logic CTRL pin fitted, Heatsink fitted
RP20-2405SF With Heat Sink
125
Output Power (%)
100
Derating graphs are valid only for the shown part numbers.
If you need detailed derating-information about a part-number
not shown here please contact our technical support service
at [email protected]
P-56
REV: 0/2015
75
50
Natural Convection
25
0
-40 -25 -10 0
50 60 70 80 90 100
75
Ambient Temperature Range (°C)
Refer to Application Notes
www.recom-power.com
RP20-S_DF
Series
POWERLINE
DC/DC-Converter
Typical Characteristics
RP20-2405SF
Efficiency VS Output Load
Efficiency (%)
93
92
91
90
89
88
87
86
85
84
83
82
Efficiency (%)
Efficiency VS Input Voltage
18
20
22
24
26
28
30
32
34
36
95
90
85
80
75
70
65
60
Input Voltage (V)
10
20
30 40
50 60 70
Output Load (%)
80
90
100
Specifications (typical at nominal input and 25°C unless otherwise noted)
Input Voltage Range
Input Filter
12V nominal input
9-18VDC
24V nominal input
18-36VDC
48V nominal input
36-75VDC
(9)
L-C Type
(Complies with ETS300 132 part 4.4)
Input Surge Voltage (100 ms max.)
12V Input
36VDC
24V Input
50VDC
48V Input
100VDC
Input Reflected Ripple (nominal Vin and full load)
(3)
20mAp-p
Start Up Time (nominal Vin and constant resistor load)
Remote ON/OFF
(7)
Remote OFF input current
10ms typ.
DC-DC ON
Open or 3.0V < Vr < 12V
DC-DC OFF
Short or 0V < Vr < 1.2V
Nominal input
Output Power
2.5mA
20W max.
Output Voltage Accuracy (full Load and nominal Vin)
±1%
Voltage Adjustability
Minimum Load
5V/ms max
(1)
±10%
Single
Dual
0%
10% of full load
Line Regulation (low line, high line at full load)
±0.2%
Load Regulation (25% to 100% full load)
±0.5%
Cross Regulation (asymmetrical 25% <>100% load)
Dual
±5%
Ripple and Noise (20MHz bandwidth, with 1µF MLCC on output)
Single 1.5, 1.8, 2.5, 3.3V
60mVp-p
(Measured with a 1004pF/50V MLCC)
Single 5, 12, 15V
75mVp-p
Dual 5, 12, 15V
100mVp-p
continued on next page
www.recom-power.com
REV: 0/2015
P-57
RP20-F
Input Voltage Variation dv/dt
RP20-S_DF
Series
POWERLINE
DC/DC-Converter
Specifications (typical at nominal input and 25°C unless otherwise noted)
Temperature Coefficient
±0.02%/°C max.
Transient Response (25% load step change)
500µs
Over Voltage Protection
1.5, 1.8, 2.5, 3.3V
3.9V
Zener diode clamp (only single)
5V
6.2V
12V
15V
15V
18V
Over Load Protection (% of full load at nominal Vin)
150% typ
Undervoltage Lockout
none
Short Circuit Protection
Hiccup, automatic recovery
Efficiency
see „Selection Guide“ table
Isolation Voltage
Input to Output
1600VDC
(rated for one minute)
Input (Output) to case
1600VDC
Isolation Resistance
1 GΩ min.
Isolation Capacitance
1000pF max.
Operating Frequency
500kHz typ.
Operating Temperature Range
-40°C to +85°C(with derating)
Maximum Case Temperature
+100°C
Storage Temperature Range
-55°C to +125°C
Thermal Impedance
(8)
Natural convection
12°C/Watt
Natural convection with Heat Sink
10°C/Watt
RP20-F
Thermal Shock
MIL-STD-810D
Vibration
10-55Hz, 10G, 30 Min. along X, Y and Z
Relative Humidity
5% to 95% RH
Case Material
Nickel plated copper
Base Material
Non-conductive black plastic
Potting Material
Conducted Emissions
Radiated Emissions
Epoxy (UL94-V0)
(9, 10)
EN55022
Class A
EN55022
Class A
ESD
EN61000-4-2
Perf. Criteria B
Radiated Immunity
EN61000-4-3
Perf. Criteria B
Fast Transient
EN61000-4-4
Perf. Criteria B
Surge
EN61000-4-5
Perf. Criteria B
Conducted Immunity
EN61000-4-6
Perf. Criteria B
Weight
Packing Quantity
27g
Refer to App Notes for tube dimensions
Dimensions
MTBF
P-58
9 pcs per Tube
50.8 x 25.4 x 10.2mm
1791 x 103 hours
(2)
REV: 0/2015
www.recom-power.com
RP20-S_DF
Series
POWERLINE
DC/DC-Converter
Notes :
1. The RP20-S_DF series requires a minimum of 10% loading on the output to maintain specified regulation. Operation under
no-load condition will not damage these devices, however they may not meet all listed specification.
2. BELLCORE TR-NWT-000332. Case l: 50% Stress, Temperature at 40°C (Ground fixed and controlled environment).
3. Simulated source impedance of 12µH. 12µH inductor in series with +Vin.
4. Maximum value at nominal input voltage and full load of standard type.
5. Typical value at nominal input voltage and full load.
6. Test by minimum Vin and constant resistor load.
7. The ON/OFF control function can be positive or negative logic. The pin voltage is referenced to negative input.
Positive logic ON/OFF is standard, no suffix (Ex. RP20-2405SF)
Negative logic ON/OFF is marked with suffix-N (Ex. RP20-2405SF/N).
8. Heat sink is optional and P/N: 7G-0020-C. Powerline DC/DC Converters can be ordered with pre-mounted heatsinks including antivibration fixing clips
(add suffix -HC). See Application Notes for heatsink details.
9. An external filter capacitor is required for normal operation. The capacitor should be capable of handling 1A ripple current for 48V/24V models.
RECOM suggest: Nippon chemi-con KY series, 220µF/100V, ESR 90m Ω.
10.See application notes for Class B common mode filter suggestion.
Package Style and Pinning (mm)
50.80
25.40
10.20
dia.
1.0
5.6
RP20-F
2.50
5.10
20.30
15.20
Pin Connections
Pin #
1
2
3
4
5
6
3
1
2
6
Bottom View
10.20
4
10.20
5
Dual
+Vin
-Vin
+Vout
Com
-Vout
CTRL
Pin Pitch Tolerance ±0.35 mm
12.70
External Output Trimming
Single
+Vin
-Vin
+Vout
Trim
-Vout
CTRL
5
Trim Up
4
RD
RU
Output can be externally trimmed by using the method
shown below. See Application Notes for details.
4
Trim Down
3
The product information and specifications are subject to change without prior notice. RECOM products are not authorized for use in safety-critical applications (such as life support) without RECOM’s explicit
written consent. A safety-critical application is defined as an application where a failure of a RECOM product may reasonably be expected to endanger or cause loss of life, inflict bodily harm or damage property. The buyer
shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized use of RECOM products in such safety-critical applications.
www.recom-power.com
REV: 0/2015
P-59