RP10 (E) - Recom International Power Gmbh

●
●
●
●
●
●
●
●
Features
Description
2:1 Wide Input Voltage Range
10 Watts Output Power
1.6kVDC Isolation
UL Certified
Fixed Operating Frequency
Six-Sided Continuous Shield
Standard 50.8 x25.4x10.2mm Package
Efficiency to 86 %
The RP10-E series DC/DC converters are certified to UL 60950-1 and cUL 60950-1.
This makes them ideal for all telecom and industrial applications where approved
safety standards are required.
The industry standard 2” x 1” package meets military standards for thermal shock and
vibration tolerance and is available with an optional remote on/off control pin.
This series is also available with the /M1 option which is particularly suitable for
extended temperature range applications.
POWERLINE
DC/DC-Converter
with 3 year Warranty
10 Watt
2” x 1”
Single &
Dual Output
Selection Guide 12V, 24V and 48V Input Types
Part Number
Input
Range
VDC
Output
Voltage
VDC
Output
Current
mA
Input (4)
Current
mA
Efficiency (5) Capacitive (6)
Load max.
%
RP10-1205SE
9-18
5
2000
1082
81
4700µF
RP10-1212SE
9-18
12
830
1064
82
690µF
RP10-1215SE
9-18
15
670
1088
81
470µF
RP10-2405SE
18-36
5
2000
534
82
4700µF
RP10-2412SE
18-36
12
830
519
84
690µF
RP10-2415SE
18-36
15
670
523
84
470µF
RP10-4805SE
36-75
5
2000
260
84
4700µF
RP10-4812SE
36-75
12
830
253
86
690µF
RP10-4815SE
36-75
15
670
258
85
470µF
RP10-1205DE
9-18
±5
±1000
1068
82
±680µF
RP10-1212DE
9-18
±12
±416
1053
83
±330µF
RP10-1215DE
9-18
±15
±333
1041
84
±110µF
RP10-2405DE
18-36
±5
±1000
548
80
±680µF
RP10-2412DE
18-36
±12
±416
520
84
±330µF
RP10-2415DE
18-36
±15
±333
520
84
±110µF
RP10-4805DE
36-75
±5
±1000
267
82
±680µF
RP10-4812DE
36-75
±12
±416
254
86
±330µF
RP10-4815DE
36-75
±15
±333
260
84
±110µF
RoHS
2011/65/EU
6/6
UL-60950-1 Certified
E196683
RP10-E
* add suffix /M1 for higher efficiencies and extended temperature range.
* add suffix /P for CTRL function with Positive Logic (1=ON, 0=OFF)
* add suffix /N for CTRL function with Negative Logic (0=ON, 1=OFF)
* add suffix -HC for premounted heatsink and clips
Ordering Examples
RP10-1205SE/P = 12V Input, 5V Output, Standard Temp. Range, Positive Logic CTRL pin fitted
RP10-4805DE/M1-HC = 48V Input, ±5V Output, Extended Temp. Range, No CTRL pin, Heatsink fitted
Refer to Application Notes
P-10
REV: 0/2015
www.recom-power.com
RP10-S_DE
Series
POWERLINE
DC/DC-Converter
Derating Graph (Ambient Temperature)
RP10-2405SE With Heat Sink
RP10-2405SE
125
125
100
100
50
75
Natural Convection
Output Power (%)
Output Power (%)
75
25
0
-25
-10 0
50 60 70
Ambient Temperature Range (°C)
80 90 100
79
100
100
50
75
Natural Convection
25
0
-25
-10 0
50 60 70
80 90 100
79
50
0
-25
100
75
75
Output Power (%)
Natural Convection
25
80 90 100
50
25
0
-40 -25 -10 0
125
100
100
75
Output Power (%)
Natural Convection
25
0
-40 -25 -10 0
50 60 70
Ambient Temperature Range (°C)
50 60 70
80 90 100
85
RP10-2405SE_DE/M1 With Heat Sink
125
50
Natural Convection
Ambient Temperature Range (°C)
RP10-4805SE/M1
75
50 60 70 80 90 100
83
RP10-E
100
50 60 70
Ambient Temperature Range (°C)
-10 0
RP10-2405SE_DE/M1
125
-10 0
Natural Convection
25
125
0
-25
50 60 70 80 90 100
81
Ambient Temperature Range (°C)
RP10-4805SE
50
-10 0
RP10-2405DE With Heat Sink
Output Power (%)
Output Power (%)
0
-25
125
Ambient Temperature Range (°C)
Output Power (%)
25
125
75
Natural Convection
Ambient Temperature Range (°C)
RP10-2405DE
Output Power (%)
50
80 90 100
85
50
Natural Convection
25
0
-40 -25 -10 0
50 60 70
Ambient Temperature Range (°C)
80 90 100
88
Derating graphs are valid only for the shown part numbers. If you need detailed derating-information about a part-number not shown here
please contact our technical support service at [email protected]
www.recom-power.com
REV: 0/2015
P-11
RP10-S_DE
Series
POWERLINE
DC/DC-Converter
Specifications (typical at nominal input and 25°C unless otherwise noted)
Input Voltage Range
12V nominal input
9-18VDC
24V nominal input
18-36VDC
48V nominal input
36-75VDC
Input Filter
Pi Type
Input Surge Voltage (100 ms max.)
Input Reflected Ripple (nominal Vin and full load)
12V Input
36VDC
24V Input
50VDC
48V Input
100VDC
(3)
30mAp-p
Start Up Time (nominal Vin and constant resistor load)
Remote ON/OFF
20ms typ.
(7)
(Positive logic)
(Negative logic)
Remote OFF input current
DC-DC ON
Open or 3.5V < Vr < 12V
DC-DC OFF
Short or 0V < Vr < 1.2V
DC-DC ON
Short or 0V < Vr < 1.2V
DC-DC OFF
Open or 3.5V < Vr < 12V
Nominal input
Output Power
10W max.
Output Voltage Accuracy (full Load and nominal Vin)
Minimum Load
±2%
(1)
10% of full load
Line Regulation (low line, high line at full load)
Load Regulation (25% to 100% full load)
±1%
Single
±1%
Dual
±2%
Cross Regulation (asymmetrical25% <>100% load)
RP10-E
20mA
Ripple and Noise (20MHz bandwidth, with 1µF MLCC on output)
±5%
Single
50mVp-p
Dual
75mVp-p
Temperature Coefficient
±0.02%/°C max.
Transient Response (25% load step change)
500µs
Over Voltage Protection
3.3V output
3.9V
Zener diode clamp
5V output
6.2V
12V output
15V
15V output
18V
Over Load Protection (% of full load at nominal Vin)
150% typ
Undervoltage Lockout
none
Short Circuit Protection
Hiccup, automatic recovery
Efficiency
see „Selection Guide“ table
Isolation Voltage (rated for one minute)
1600VDC
Isolation Resistance
1 GΩ min.
Isolation Capacitance
300pF max.
Operating Frequency
300kHz typ.
Approved to Safety Standards (9)
Operating Temperature Range
(Reference Derating Curve)
(10)
UL 1950, EN60950
Standard
-25°C to +85°C(with derating)
M1
-40°C to +85°C(non derating)
Maximum Case Temperature
+100°C
Storage Temperature Range
-55°C to +125°C
continued on next page
P-12
REV: 0/2015
www.recom-power.com
RP10-S_DE
Series
POWERLINE
DC/DC-Converter
Specifications (typical at nominal input and 25°C unless otherwise noted)
Thermal Impedance (8)
Natural convection
12°C/Watt
Natural convection with Heat Sink
10°C/Watt
Thermal Shock
MIL-STD-810D
Vibration
10-55Hz, 10G, 30 Min. along X, Y and Z
Relative Humidity
5% to 95% RH
Case Material
Nickel plated copper
Base Material
Non-conductive black plastic
Potting Material
Conducted Emissions
Radiated Emissions
ESD
Radiated Immunity
Fast Transient
Surge
Conducted Immunity
Epoxy (UL94-V0)
(11)
EN55022
EN55022
EN61000-4-2
EN61000-4-3
EN61000-4-4
EN61000-4-5
EN61000-4-6
Level A
Level A
Perf. Criteria B
Perf. Criteria B
Perf. Criteria B
Perf. Criteria B
Perf. Criteria B
Weight
27g
Packing Quantity
Refer to App Notes for tube dimensions
Dimensions
MTBF
9 pcs per Tube
50.8 x 25.4 x 10.2mm
1976 x 103 hours
(2)
Package Style and Pinning (mm)
50.80
25.40
10.20
dia.
1.0
5.6
RP10-E
2.50
5.10
20.30
15.20
Pin Connections
3
1
2
6
Bottom View
10.20
4
10.20
5
12.70
Pin #
Single
1
+Vin
2
-Vin
3
+Vout
4
No Pin
5
-Vout
6*
CTRL*
*Optional. See Note 7.
Dual
+Vin
-Vin
+Vout
Com
-Vout
CTRL*
Pin Pitch Tolerance ±0.35 mm
Notes :
1. The RP10 (W) series required a minimum 10% loading on the output to maintain specified regulation.
Operation under no-load condition will not damage these devices, however they may not meet all listed specification.
2. BELLCORE TR-NWT-000332. Case I: 50% Stress, Temperature at 40ºC. (Ground fixed and controlled environment).
3. Simulated source impedance of 12µH. 12µH inductor in series with +Vin.
4. Maximum value at nominal input voltage and full load of standard type.
5. Typical value at nominal input voltage and full load.
6. Test by minimum Vin and constant resistor load.
7. The ON/OFF control function can be positive or negative logic. The pin voltage is referenced to negative input.
Positive logic ON/OFF is marked with suffix-P (eg. RP10-2405SE/P), Negative logic ON/OFF is marked with suffix-N (eg. RP10-2405SE/N).
If no suffix is specified, the control pin will be omitted.
8. Heat sink is optional and P/N: 7G-0020C. Powerline DC/DC Converters can be ordered with pre-mounted heatsinks including antivibration fixing clips
(add suffix -HC). See Application Notes for heatsink details.
9. The M1 version (RP10-xxxxSE/M1, RP10-xxxxDE/M1) does not carry the UL certification.
10. M1 version is more efficient, therefore, it can be operated in a more extensive temperature range than standard version.
11. See application notes for EMI-filtering.
The product information and specifications are subject to change without prior notice. RECOM products are not authorized for use in safety-critical applications (such as life support) without RECOM’s explicit
written consent. A safety-critical application is defined as an application where a failure of a RECOM product may reasonably be expected to endanger or cause loss of life, inflict bodily harm or damage property. The buyer
shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized use of RECOM products in such safety-critical applications.
www.recom-power.com
REV: 0/2015
P-13