● ● ● ● ● ● ● ● Features Description 2:1 Wide Input Voltage Range 10 Watts Output Power 1.6kVDC Isolation UL Certified Fixed Operating Frequency Six-Sided Continuous Shield Standard 50.8 x25.4x10.2mm Package Efficiency to 86 % The RP10-E series DC/DC converters are certified to UL 60950-1 and cUL 60950-1. This makes them ideal for all telecom and industrial applications where approved safety standards are required. The industry standard 2” x 1” package meets military standards for thermal shock and vibration tolerance and is available with an optional remote on/off control pin. This series is also available with the /M1 option which is particularly suitable for extended temperature range applications. POWERLINE DC/DC-Converter with 3 year Warranty 10 Watt 2” x 1” Single & Dual Output Selection Guide 12V, 24V and 48V Input Types Part Number Input Range VDC Output Voltage VDC Output Current mA Input (4) Current mA Efficiency (5) Capacitive (6) Load max. % RP10-1205SE 9-18 5 2000 1082 81 4700µF RP10-1212SE 9-18 12 830 1064 82 690µF RP10-1215SE 9-18 15 670 1088 81 470µF RP10-2405SE 18-36 5 2000 534 82 4700µF RP10-2412SE 18-36 12 830 519 84 690µF RP10-2415SE 18-36 15 670 523 84 470µF RP10-4805SE 36-75 5 2000 260 84 4700µF RP10-4812SE 36-75 12 830 253 86 690µF RP10-4815SE 36-75 15 670 258 85 470µF RP10-1205DE 9-18 ±5 ±1000 1068 82 ±680µF RP10-1212DE 9-18 ±12 ±416 1053 83 ±330µF RP10-1215DE 9-18 ±15 ±333 1041 84 ±110µF RP10-2405DE 18-36 ±5 ±1000 548 80 ±680µF RP10-2412DE 18-36 ±12 ±416 520 84 ±330µF RP10-2415DE 18-36 ±15 ±333 520 84 ±110µF RP10-4805DE 36-75 ±5 ±1000 267 82 ±680µF RP10-4812DE 36-75 ±12 ±416 254 86 ±330µF RP10-4815DE 36-75 ±15 ±333 260 84 ±110µF RoHS 2011/65/EU 6/6 UL-60950-1 Certified E196683 RP10-E * add suffix /M1 for higher efficiencies and extended temperature range. * add suffix /P for CTRL function with Positive Logic (1=ON, 0=OFF) * add suffix /N for CTRL function with Negative Logic (0=ON, 1=OFF) * add suffix -HC for premounted heatsink and clips Ordering Examples RP10-1205SE/P = 12V Input, 5V Output, Standard Temp. Range, Positive Logic CTRL pin fitted RP10-4805DE/M1-HC = 48V Input, ±5V Output, Extended Temp. Range, No CTRL pin, Heatsink fitted Refer to Application Notes P-10 REV: 0/2015 www.recom-power.com RP10-S_DE Series POWERLINE DC/DC-Converter Derating Graph (Ambient Temperature) RP10-2405SE With Heat Sink RP10-2405SE 125 125 100 100 50 75 Natural Convection Output Power (%) Output Power (%) 75 25 0 -25 -10 0 50 60 70 Ambient Temperature Range (°C) 80 90 100 79 100 100 50 75 Natural Convection 25 0 -25 -10 0 50 60 70 80 90 100 79 50 0 -25 100 75 75 Output Power (%) Natural Convection 25 80 90 100 50 25 0 -40 -25 -10 0 125 100 100 75 Output Power (%) Natural Convection 25 0 -40 -25 -10 0 50 60 70 Ambient Temperature Range (°C) 50 60 70 80 90 100 85 RP10-2405SE_DE/M1 With Heat Sink 125 50 Natural Convection Ambient Temperature Range (°C) RP10-4805SE/M1 75 50 60 70 80 90 100 83 RP10-E 100 50 60 70 Ambient Temperature Range (°C) -10 0 RP10-2405SE_DE/M1 125 -10 0 Natural Convection 25 125 0 -25 50 60 70 80 90 100 81 Ambient Temperature Range (°C) RP10-4805SE 50 -10 0 RP10-2405DE With Heat Sink Output Power (%) Output Power (%) 0 -25 125 Ambient Temperature Range (°C) Output Power (%) 25 125 75 Natural Convection Ambient Temperature Range (°C) RP10-2405DE Output Power (%) 50 80 90 100 85 50 Natural Convection 25 0 -40 -25 -10 0 50 60 70 Ambient Temperature Range (°C) 80 90 100 88 Derating graphs are valid only for the shown part numbers. If you need detailed derating-information about a part-number not shown here please contact our technical support service at [email protected] www.recom-power.com REV: 0/2015 P-11 RP10-S_DE Series POWERLINE DC/DC-Converter Specifications (typical at nominal input and 25°C unless otherwise noted) Input Voltage Range 12V nominal input 9-18VDC 24V nominal input 18-36VDC 48V nominal input 36-75VDC Input Filter Pi Type Input Surge Voltage (100 ms max.) Input Reflected Ripple (nominal Vin and full load) 12V Input 36VDC 24V Input 50VDC 48V Input 100VDC (3) 30mAp-p Start Up Time (nominal Vin and constant resistor load) Remote ON/OFF 20ms typ. (7) (Positive logic) (Negative logic) Remote OFF input current DC-DC ON Open or 3.5V < Vr < 12V DC-DC OFF Short or 0V < Vr < 1.2V DC-DC ON Short or 0V < Vr < 1.2V DC-DC OFF Open or 3.5V < Vr < 12V Nominal input Output Power 10W max. Output Voltage Accuracy (full Load and nominal Vin) Minimum Load ±2% (1) 10% of full load Line Regulation (low line, high line at full load) Load Regulation (25% to 100% full load) ±1% Single ±1% Dual ±2% Cross Regulation (asymmetrical25% <>100% load) RP10-E 20mA Ripple and Noise (20MHz bandwidth, with 1µF MLCC on output) ±5% Single 50mVp-p Dual 75mVp-p Temperature Coefficient ±0.02%/°C max. Transient Response (25% load step change) 500µs Over Voltage Protection 3.3V output 3.9V Zener diode clamp 5V output 6.2V 12V output 15V 15V output 18V Over Load Protection (% of full load at nominal Vin) 150% typ Undervoltage Lockout none Short Circuit Protection Hiccup, automatic recovery Efficiency see „Selection Guide“ table Isolation Voltage (rated for one minute) 1600VDC Isolation Resistance 1 GΩ min. Isolation Capacitance 300pF max. Operating Frequency 300kHz typ. Approved to Safety Standards (9) Operating Temperature Range (Reference Derating Curve) (10) UL 1950, EN60950 Standard -25°C to +85°C(with derating) M1 -40°C to +85°C(non derating) Maximum Case Temperature +100°C Storage Temperature Range -55°C to +125°C continued on next page P-12 REV: 0/2015 www.recom-power.com RP10-S_DE Series POWERLINE DC/DC-Converter Specifications (typical at nominal input and 25°C unless otherwise noted) Thermal Impedance (8) Natural convection 12°C/Watt Natural convection with Heat Sink 10°C/Watt Thermal Shock MIL-STD-810D Vibration 10-55Hz, 10G, 30 Min. along X, Y and Z Relative Humidity 5% to 95% RH Case Material Nickel plated copper Base Material Non-conductive black plastic Potting Material Conducted Emissions Radiated Emissions ESD Radiated Immunity Fast Transient Surge Conducted Immunity Epoxy (UL94-V0) (11) EN55022 EN55022 EN61000-4-2 EN61000-4-3 EN61000-4-4 EN61000-4-5 EN61000-4-6 Level A Level A Perf. Criteria B Perf. Criteria B Perf. Criteria B Perf. Criteria B Perf. Criteria B Weight 27g Packing Quantity Refer to App Notes for tube dimensions Dimensions MTBF 9 pcs per Tube 50.8 x 25.4 x 10.2mm 1976 x 103 hours (2) Package Style and Pinning (mm) 50.80 25.40 10.20 dia. 1.0 5.6 RP10-E 2.50 5.10 20.30 15.20 Pin Connections 3 1 2 6 Bottom View 10.20 4 10.20 5 12.70 Pin # Single 1 +Vin 2 -Vin 3 +Vout 4 No Pin 5 -Vout 6* CTRL* *Optional. See Note 7. Dual +Vin -Vin +Vout Com -Vout CTRL* Pin Pitch Tolerance ±0.35 mm Notes : 1. The RP10 (W) series required a minimum 10% loading on the output to maintain specified regulation. Operation under no-load condition will not damage these devices, however they may not meet all listed specification. 2. BELLCORE TR-NWT-000332. Case I: 50% Stress, Temperature at 40ºC. (Ground fixed and controlled environment). 3. Simulated source impedance of 12µH. 12µH inductor in series with +Vin. 4. Maximum value at nominal input voltage and full load of standard type. 5. Typical value at nominal input voltage and full load. 6. Test by minimum Vin and constant resistor load. 7. The ON/OFF control function can be positive or negative logic. The pin voltage is referenced to negative input. Positive logic ON/OFF is marked with suffix-P (eg. RP10-2405SE/P), Negative logic ON/OFF is marked with suffix-N (eg. RP10-2405SE/N). If no suffix is specified, the control pin will be omitted. 8. Heat sink is optional and P/N: 7G-0020C. Powerline DC/DC Converters can be ordered with pre-mounted heatsinks including antivibration fixing clips (add suffix -HC). See Application Notes for heatsink details. 9. The M1 version (RP10-xxxxSE/M1, RP10-xxxxDE/M1) does not carry the UL certification. 10. M1 version is more efficient, therefore, it can be operated in a more extensive temperature range than standard version. 11. See application notes for EMI-filtering. The product information and specifications are subject to change without prior notice. RECOM products are not authorized for use in safety-critical applications (such as life support) without RECOM’s explicit written consent. A safety-critical application is defined as an application where a failure of a RECOM product may reasonably be expected to endanger or cause loss of life, inflict bodily harm or damage property. The buyer shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized use of RECOM products in such safety-critical applications. www.recom-power.com REV: 0/2015 P-13