● ● ● ● ● ● ● Features Description 4:1 Wide Input Voltage Range 10 Watts Output Power 1.6kVDC Isolation Fixed Operating Frequency Six-Sided Continuous Shield Standard 50.8 x25.4x10.2mm Package Efficiency to 84 % The RP10-EW series wide input range DC/DC converters are certified to UL 60950-1 and cUL 60950-1. This makes them ideal for all telecom and industrial applications where approved safety standards are required. The industry standard 2” x 1” package meets military standards for thermal shock and vibration tolerance and is available with an optional remote on/off control pin. This series is also available with the /M2 option which is particularly suitable for extended temperature range applications. POWERLINE DC/DC-Converter with 3 year Warranty 10 Watt 2” x 1” Single & Dual Output Selection Guide 24V and 48V Input Types Input Range VDC Output Voltage VDC Output Current mA Input (4) Current mA RP10-2405SEW 9-36 5 2000 548 80 4700µF RP10-2412SEW 9-36 12 830 532 82 690µF RP10-2415SEW 9-36 15 670 551 80 470µF RP10-4805SEW 18-75 5 2000 274 80 4700µF RP10-4812SEW 18-75 12 830 259 84 690µF RP10-4815SEW 18-75 15 670 262 84 470µF RP10-2405DEW 9-36 ±5 ±1000 548 80 ±680µF RP10-2412DEW 9-36 ±12 ±416 547 80 ±330µF RP10-2415DEW 9-36 ±15 ±333 548 80 ±110µF RP10-4805DEW 18-75 ±5 ±1000 271 81 ±680µF RP10-4812DEW 18-75 ±12 ±416 281 78 ±330µF RP10-4815DEW 18-75 ±15 ±333 270 81 ±110µF Part Number Efficiency (5) Capacitive (6) Load max. % RoHS 2011/65/EU 6/6 UL-60950-1 Certified E196683 RP10-EW * add suffix /M2 for higher efficiencies and extended temperature range. * add suffix /P for CTRL function with Positive Logic (1=ON, 0=OFF) * add suffix /N for CTRL function with Negative Logic (0=ON, 1=OFF) * add suffix -HC for premounted heatsink and clips Ordering Examples RP10-2405SE/P = 24V 4:1 Input, 5V Output, Standard Temp. Range, Positive Logic CTRL pin fitted RP10-4805DE/M1-HC = 48V 4:1Input, ±5V Output, Extended Temp. Range, No CTRL, Heatsink fitted Refer to Application Notes P-14 REV: 0/2015 www.recom-power.com RP10-S_DEW Series POWERLINE DC/DC-Converter Derating Graph (Ambient Temperature) RP10-2405SEW With Heat Sink RP10-2405SEW 125 125 100 100 75 Natural Convection 50 25 0 -25 -10 0 50 60 70 80 90 100 Output Power (%) Output Power (%) 75 Ambient Temperature Range (°C) -10 0 50 60 70 80 90 100 Ambient Temperature Range (°C) 75 100 100 75 75 25 0 -25 Natural Convection -10 0 50 60 70 80 90 100 Ambient Temperature Range (°C) 74 Output Power (%) Output Power (%) 0 -25 125 50 25 0 -25 100 100 75 75 Output Power (%) 25 0 -40 -25 -10 0 50 60 70 Ambient Temperature Range (°C) 80 90 100 50 0 -40 -25 -10 0 RP10-2405DEW/M2 With Heat Sink 125 100 100 25 0 -40 -25 -10 0 75 Output Power (%) 50 Natural Convection 25 125 Natural Convection 80 90 100 78 50 60 70 80 90 100 Ambient Temperature Range (°C) 75 RP10-2405DEW/M2 75 50 60 70 RP10-EW 125 50 -10 0 RP10-2405SEW/M2 With Heat Sink 125 Natural Convection Natural Convection Ambient Temperature Range (°C) RP10-2405SEW/M2 Output Power (%) 25 125 50 Natural Convection RP10-2405DEW With Heat Sink RP10-2405DEW Output Power (%) 50 50 60 70 80 90 100 Ambient Temperature Range (°C) 74 50 Natural Convection 25 0 -40 -25 -10 0 50 60 70 Ambient Temperature Range (°C) 80 90 100 78 Derating graphs are valid only for the shown part numbers. If you need detailed derating-information about a part-number not shown here please contact our technical support service at [email protected] www.recom-power.com REV: 0/2015 P-15 RP10-S_DEW Series POWERLINE DC/DC-Converter Specifications (typical at nominal input and 25°C unless otherwise noted) Input Voltage Range 24V nominal input 9-36VDC 48V nominal input 18-75VDC Input Filter Pi Type Input Surge Voltage (100 ms max.) 24V Input 50VDC 48V Input 100VDC Input Reflected Ripple (nominal Vin and full load) 30mAp-p Start Up Time (nominal Vin and constant resistor load) 20ms typ. Remote ON/OFF (7) (Positive logic) (Negative logic) Remote OFF input current DC-DC ON Open or 3.5V < Vr < 12V DC-DC OFF Short or 0V < Vr < 1.2V DC-DC ON Short or 0V < Vr < 1.2V DC-DC OFF Open or 3.5V < Vr < 12V Nominal input Output Power 10W max. Output Voltage Accuracy (full Load and nominal Vin) Minimum Load ±2% (1) 10% of full load Line Regulation (low line, high line at full load) Load Regulation (25% to 100% full load) ±1% Single ±1% Dual ±2% Cross Regulation (asymmetrical 25%<>100% load) Ripple and Noise (20MHz bandwidth, with 1µF MLCC on output) RP10-EW 20mA ±5% Single 50mVp-p Dual 75mVp-p Temperature Coefficient ±0.02%/°C max. Transient Response (25% load step change) Over Voltage Protection Zener diode clamp 500µs 5V output 6.2V 12V output 15V 15V output 18V Over Load Protection (% of full load at nominal Vin) 150% typ Undervoltage Lockout none Short Circuit Protection Hiccup, automatic recovery Efficiency see „Selection Guide“ table Isolation Voltage (rated for one minute) 1600VDC Isolation Resistance 1 GΩ min. Isolation Capacitance 300pF max. Operating Frequency Operating Temperature Range (Reference Derating Curve) 300kHz typ. (9) Standard -25°C to +85°C(with derating) M2 -40°C to +85°C(with derating) Maximum Case Temperature +100°C Storage Temperature Range -55°C to +125°C Thermal Impedance (8) Natural convection 12°C/Watt Natural convection with Heat Sink 10°C/Watt Thermal Shock MIL-STD-810D Vibration 10-55Hz, 10G, 30 Min. along X, Y and Z continued on next page P-16 REV: 0/2015 www.recom-power.com RP10-S_DEW Series POWERLINE DC/DC-Converter Specifications (typical at nominal input and 25°C unless otherwise noted) Relative Humidity 5% to 95% RH Case Material Nickel plated copper Base Material Non-conductive black plastic Potting Material Conducted Emissions (10) Radiated Emissions ESD Radiated Immunity Fast Transient Surge Conducted Immunity Epoxy (UL94-V0 Level A Level A Perf. Criteria B Perf. Criteria B Perf. Criteria B Perf. Criteria B Perf. Criteria B EN55022 EN55022 EN61000-4-2 EN61000-4-3 EN61000-4-4 EN61000-4-5 EN61000-4-6 Weight 27g Packing Quantity Refer to App Notes for tube dimensions 9pcs per Tube Dimensions 50.8 x 25.4 x 10.2mm MTBF (2) BELLCORE TR-NWT-000332 1976 x 103 hours MIL-HDBK-217F 1416 x 103 hours Package Style and Pinning (mm) 50.80 25.40 10.20 dia. 1.0 5.6 2.50 5.10 20.30 15.20 1 2 6 10.20 4 10.20 5 12.70 RP10-EW Pin # Single 1 +Vin 2 -Vin 3 +Vout 4 No Pin 5 -Vout 6* CTRL* * Optional. See Note 7 3 Bottom View Pin Connections Dual +Vin -Vin +Vout Com -Vout CTRL* Pin Pitch Tolerance ±0.35 mm Notes : 1. The RP10 (W) series required a minimum 10% loading on the output to maintain specified regulation. Operation under no-load condition will not damage these devices, however they may not meet all listed specification. 2. BELLCORE TR-NWT-000332. Case I: 50% Stress, Temperature at 40ºC. (Ground fixed and controlled environment). 3. Simulated source impedance of 12µH. 12µH inductor in series with +Vin. 4. Maximum value at nominal input voltage and full load of standard type. 5. Typical value at nominal input voltage and full load. 6. Test by minimum Vin and constant resistor load. 7. The ON/OFF control function can be positive or negative logic. The pin voltage is referenced to negative input. Positive logic ON/OFF is marked with suffix-P (eg. RP10-2405SEW/P) Negative logic ON/OFF is marked with suffix-N (eg. RP10-2405SEW/N). If no suffix is specified, the control pin will be omitted. 8. Heat sink is optional and P/N: 7G-0020C. Powerline DC/DC Converters can be ordered with pre-mounted heatsinks including antivibration fixing clips (add suffix -HC). See Application Notes for heatsink details. 9. M2 version is more efficient, therefore, it can be operated in a more extensive temperature range than standard version. 10. See application notes for EMI-filtering. The product information and specifications are subject to change without prior notice. RECOM products are not authorized for use in safety-critical applications (such as life support) without RECOM’s explicit written consent. A safety-critical application is defined as an application where a failure of a RECOM product may reasonably be expected to endanger or cause loss of life, inflict bodily harm or damage property. The buyer shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized use of RECOM products in such safety-critical applications. www.recom-power.com REV: 0/2015 P-17