● ● ● ● ● ● ● ● Features Description 2:1 Wide Input Voltage Range 15 Watts Output Power 1.6kVDC Isolation UL Certified Fixed Operating Frequency Six-Sided Continuous Shield Standard 50.8 x25.4x10.2mm Package Efficiency to 88 % The RP15-F series DC/DC converters are certified to UL 60950-1 and to cUL 609501. This makes them ideal for all telecom and industrial applications where approved safety standards are required. The industry standard 2” x 1” package meets military standards for thermal shock and vibration tolerance. Selection Guide 12V, 24V and 48V Input Types POWERLINE DC/DC-Converter with 3 year Warranty 15 Watt 2” x 1” Single & Dual Output Input (4) Efficiency (5) Capacitive (6) Current Load max. mA % Part Number Input Range VDC Output Voltage VDC Output Current mA RP15-123.3SF 9-18 3.3 4000 1467 79 10200µF RP15-1205SF 9-18 5 3000 1603 82 7050µF RP15-1212SF 9-18 12 1250 1524 86 1035µF RP15-1215SF 9-18 15 1000 1524 86 705µF RP15-243.3SF 18-36 3.3 4000 724 80 10200µF RP15-2405SF 18-36 5 3000 781 84 7050µF RP15-2412SF 18-36 12 1250 772 85 1035µF RP15-2415SF 18-36 15 1000 772 85 705µF RP15-483.3SF 36-75 3.3 4000 357 81 10200µF RP15-4805SF 36-75 5 3000 396 83 7050µF RP15-4812SF 36-75 12 1250 377 87 1035µF RP15-4815SF 36-75 15 1000 381 86 705µF RP15-1205DF 9-18 ±5 ±1500 1582 83 ±1020µF RP15-1212DF 9-18 ±12 ±625 1524 86 ±495µF RP15-1215DF 9-18 ±15 ±500 1563 84 ±165µF RP15-2405DF 18-36 ±5 ±1500 781 84 ±1020µF RP15-2412DF 18-36 ±12 ±625 762 86 ±495µF 125 RP15-2415DF 18-36 ±15 ±500 762 86 ±165µF 100 RP15-4805DF 36-75 ±5 ±1500 386 85 ±1020µF 75 RP15-4812DF 36-75 ±12 ±625 372 88 ±495µF 377 87 ±165µF UL-60950-1 Certified E196683 RP15-F Derating-Graph (Ambient Temperature) Output Power (%) RP15-4815DF 36-75 ±15 ±500 * add /P for CTRL function with Positive Logic (1=ON, 0=OFF) * add /N for CTRL function with Negative Logic (0=ON, 1=OFF) * add suffix -HC for premounted heatsink and clips RoHS 2011/65/EU 6/6 50 RP15-4805SF Natural Convection 25 0 -40 -25 -10 0 50 60 70 Ambient Temperature Range (°C) 80 90 100 RP15-4805SF With Heat Sink 125 Ordering Examples RP15-2405SF/P = 24V Input, 5V Output, Positive Logic CTRL pin fitted RP15-4805DF-HC = 48V Input, ±5V Output, No CTRL pin, Heatsink fitted 100 Output Power (%) 75 Derating graphs are valid only for the shown part numbers. If you need detailed derating-information about a part-number not shown here please contact our technical support service at [email protected] www.recom-power.com REV: 0/2015 50 Natural Convection 25 0 -40 -25 -10 0 50 60 Ambient Temperature Range (°C) 70 80 90 100 Refer to Application Notes P-41 RP15-S_DF Series POWERLINE DC/DC-Converter RP15-4805SF RP15-4805SF Efficiency VS Input Voltage Efficiency VS Output load 83 82 81 80 79 78 77 76 75 74 73 36 Efficiency (%) Efficiency (%) Typical Characteristics 40 45 50 60 55 65 70 75 83 82 81 80 79 78 77 76 70 65 50 0.5 1 1.5 2 2.5 3 Output Load (A) Input Voltage (V) Specifications (typical at nominal input and 25°C unless otherwise noted) Input Voltage Range 12V nominal input 9-18VDC 24V nominal input 18-36VDC 48V nominal input 36-75VDC Input Filter Pi Type RP15-F Input Surge Voltage (100 ms max.) Input Reflected Ripple (nominal Vin and full load) 12V Input 36VDC 24V Input 50VDC 48V Input 100VDC (3) 20mAp-p Start Up Time (nominal Vin and constant resistor load) Remote ON/OFF 20ms typ. (7) (Positive logic) DC-DC ON DC-DC OFF Short or 0V < Vr < 1.2V (Negative logic) DC-DC ON Short or 0V < Vr < 1.2V DC-DC OFF Open or 3.5V < Vr < 12V Remote OFF input current Nominal input Output Power ±1% Minimum Load (1) 10% of full load Line Regulation (low line, high line at full load) ±1% Single ±1% Dual ±2% Cross Regulation (asymmetrical 25% y<>100% load) Ripple and Noise (20MHz bandwidth, with 1µF MLCC on output) 20mA 15W max. Output Voltage Accuracy (full Load and nominal Vin) Load Regulation (25% to 100% full load) Open or 3.5V < Vr < 12V ±5% Single 50mVp-p Dual 75mVp-p Temperature Coefficient ±0.02%/°C max. continued on next page P-42 REV: 0/2015 www.recom-power.com RP15-S_DF Series POWERLINE DC/DC-Converter Specifications (typical at nominal input and 25°C unless otherwise noted) Transient Response (25% load step change) 500µs Over Voltage Protection 3.3V 3.9V Zener diode clamp (only single) 5V 6.2V 12V 15V 15V 18V Over Load Protection (% of full load at nominal Vin) 150% typ Undervoltage Lockout none Short Circuit Protection Hiccup, automatic recovery Efficiency see „Selection Guide“ table Isolation Voltage (rated for one minute) 1600VDC Isolation Resistance 1 GΩ min. Isolation Capacitance 300pF max. Operating Frequency Single 500kHz typ. Dual 300kHz typ. Approved to Safety Standards UL 1950, EN60950 Operating Temperature Range -40°C to +85°C(with derating) Maximum Case Temperature +100°C Storage Temperature Range -55°C to +125°C Thermal Impedance (8) Natural convection 12°C/Watt Natural convection with Heat Sink 10°C/Watt Thermal Shock MIL-STD-810D Vibration 10-55Hz, 10G, 30 Min. along X, Y and Z 5% to 95% RH Case Material Nickel plated copper Base Material Non-conductive black plastic Potting Material Conducted Emissions Epoxy (UL94-V0) (9) EN55022 Class A Radiated Emissions EN55022 ESD EN61000-4-2 Perf. Criteria B Radiated Immunity EN61000-4-3 Perf. Criteria B Fast Transient (9) EN61000-4-4 Perf. Criteria B EN61000-4-5 Perf. Criteria B EN61000-4-6 Perf. Criteria B Surge (9) Conducted Immunity Weight Packing Quantity 27g Refer to App Notes for tube dimensions Dimensions MTBF 9 pcs per Tube 50.8 x 25.4 x 10.2mm 2041 x 103 hours (2) www.recom-power.com Class A REV: 0/2015 P-43 RP15-F Relative Humidity RP15-S_DF Series POWERLINE DC/DC-Converter Notes : 1. The RP15 series requires a minimum of 10% loading on the output to maintain specified regulation. Operation under no-load condition will not damage these devices, however they may not meet all listed specification. 2. BELLCORE TR-NWT-000332. Case l: 50% Stress, Temperature at 40°C (Ground fixed and controlled environment). 3. Simulated source impedance of 12µH. 12µH inductor in series with +Vin. 4. Maximum value at nominal input voltage and full load of standard type. 5. Typical value at nominal input voltage and full load. 6. Test by minimum Vin and constant resistor load. 7. The ON/OFF control function can be positive or negative logic. The pin voltage is referenced to negative input. Positive logic ON/OFF is marked with suffix-P (eg. RP15-2405SF/P) Negative logic ON/OFF is marked with suffix-N (eg. RP15-2405SF/N). If no suffix is specified, the control pin will be omitted. 8. Heat sink is optional and P/N: 7G-0020-C. Powerline DC/DC Converters can be ordered with pre-mounted heatsinks including antivibration fixing clips (add suffix -HC). See Application Notes for heatsink details. 9. RP15-24xx meets Class A. RP15-48xx requires 1µF MLCC across input to meet Class A. An external capacitor (220µF/Low ESR) is required to meet EN61000-4-4 and -5 See application notes for Class B common mode filter suggestion. Package Style and Pinning (mm) RP15-F 50.80 25.40 10.20 dia. 1.0 5.6 2.50 5.10 20.30 15.20 Pin Connections 3 1 5.08 2.54 Bottom View 2 4 10.16 6 15.2 10.16 5 12.70 20.32 Pin # Single 1 +Vin 2 -Vin 3 +Vout 4 No Pin 5 -Vout 6* CTRL* * Optional. See Note 7. Dual +Vin -Vin +Vout Com -Vout CTRL* Pin Pitch Tolerance ±0.25 mm Pin dimension tolerance ±0.1 mm Tolerance: X.X ±0.5mm X.XX ±0.25mm The product information and specifications are subject to change without prior notice. RECOM products are not authorized for use in safety-critical applications (such as life support) without RECOM’s explicit written consent. A safety-critical application is defined as an application where a failure of a RECOM product may reasonably be expected to endanger or cause loss of life, inflict bodily harm or damage property. The buyer shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized use of RECOM products in such safety-critical applications. P-44 REV: 0/2015 www.recom-power.com