RAC04-C - recom

Features
Regulated
Converters
Descritption
●
●
●
●
●
●
●
POWERLINE
Universal Input 80-264VAC or 115-370VDC
Operating Temperature Range of -25°C to +85°C
Isolated Output 3kVAC / 1 min
Short Circuit and Overcurrent Protection
Low Output Ripple & Noise
Low Cost AC/DC Power Supply
EN, UL and CE certified
AC/DC-Converter
with 3 year Warranty
The new RAC04-SC modules are available with output voltages of 3.3, 5, 9, 12, 15, and
24V, and the input-to-output isolation is approximately 3kVAC/1min. With a standby
consumption of typical 100mW, the mini power supplies are particularly suitable for
energy-saving sleep mode and standby applications. Because of its compact design
(height <17 mm), it is a versatile solution for home automation and other similar
applications. Complete with an integrated input filter, the series has enhanced EMI
performance and complies with EN55022, class B. The mini power supplies are also
protected against short circuit with fully automatic restart after the error has been solved.
The converters are EN/UL60950-1 certified and come complete with a 3 year warranty.
4 Watt
Single
Output
Selection Guide
Part
Number
RAC04-3.3SC
Input
Voltage
(VAC)
80-264
Output
Voltage
(VDC)
3.3
Output
Current max.
(mA)
1200
Efficiency
Typ.
(%)
67
Max.
Capacitive
Load (1+2)
5600µF
RAC04-05SC
80-264
5
800
72
2000µF
RAC04-09SC
80-264
9
444
76
1500µF
RAC04-12SC
80-264
12
333
74
560µF
RAC04-15SC
80-264
15
267
77
470µF
RAC04-24SC
80-264
24
167
77
150µF
RoHS
2011/65/EU
6/6
Input Voltage Range (with Derating)
80-264VAC or 115-370VDC
Input Frequency (for AC Input)
47-63Hz
Input Current (Full Load)
115VAC / 230VAC
110mA / 72mA max.
Inrush Current
115VAC / 230VAC
30A / 60A max.
External Input Fuse Required
Recommended Value
1A - 1.5A / Slow Blow Type
No Load Power Consumption
80-264VAC
100mW typ. / 200mW max.
Output Voltage (Vout nom.)
3.3V-24V
Output Current Range
167mA - 1200mA
Output Voltage Tolerance
±2% typ. / ±5% max.
Minimum Load
10% min.
Output Ripple & Noise (3)
(Full Load)115VAC / 230VAC @ 20MHz limited
200mVp-p max.
Line Voltage Regulation
LL-HL at full Load
±0.5% typ. / ±1% max.
Load Voltage Regulation
10%-100% Load
±1.5% typ. / ±5% max.
Overcurrent LImit
105% - 155%
Switching Frequency
at Full Load
40kHz typ.
Isolation Voltage
Input-Output
3kVAC / 1 minute
Leakage Current
0.85mA max.
Isolation Resistance
Input-Output
1G Ω min
Isolation Capacitance
Input-Output
1000pF typ.
Short Circuit Protection
Hiccup, Auto Restart
Over Voltage Category
OVC II
(4)
Operating Temperature Range
natural convection, without derating
-20°C to +60°C
natural air convection, with derating
-25°C to +85°C
Storage Temperature Range
-40°C to +100°C
Case Material
UL94V-0 black plastic
Potting Material
Silicone
Relative Humidity
95% RH max.
Package Weight
39g typ.
Package Quantity
12 pcs
continued on next page
PA-16
REV: 1/2015
E224736
IEC-60950-1 certified
UL-60950-1 certified
RAC04-C
Derating-Graph
(Ambient Temperature)
120
100
Output Power (%)
RAC04-C
Specifications (measured at TA 25°C, nominal input voltage, full load after warm-up)
75
50
25
80
60
Safe Operating Area
40
20
0
-25
-20
0
20
40
60 70 80 100
85
Ambient Temperature Range (°C)
www.recom-power.com
RAC04-xxC
Series
POWERLINE
AC/DC-Converter
Specifications (measured at TA 25°C, nominal input voltage, full load after warm-up)
Physical
MTBF (+25°C)
EMI
Dimension (LxWxH)
MIL-HDBK-217F
Conducted and Radiated
Noise Immunity
Safety Standard
CB
UL General Safety
37.80 x 23.90 x 16.40 mm
500 * 103 hours
EN55022, Class B
EN55024
Report Number: 1111070-CB
Report Number: E224736-A5-UL
115VAC
IEC-60950-1, 2nd Edition
UL-60950-1, 2nd Edition
230VAC
115VAC in (%)
Input Voltage Derating Graph
230VAC in (%)
24V
80%
75%
5V
5V
70%
70%
90%
80V, 85%
80%
70%
3.3V
3.3V
65%
264V, 100%
90V, 100%
12V
12V
75%
100%
24V
Load (%)
80%
65%
10% 20% 30% 40% 50% 60% 70% 80% 90% 100%
10% 20% 30% 40% 50% 60% 70% 80% 90% 100%
Load (%)
Load (%)
80
180
130
230
280
Input Voltage (VAC) Ta=25°C
Notes:
1. Measured @230VAC / 50Hz
2. If used @ 115VAC / 60Hz with full load, please contact RECOM for detailed information.
3. To measure the output ripple & noise with short runs by 0.1uF/50V@20MHz, nominal input and full load.
4. Start up only is guaranteed at temperatures down to -25°C. Other specifications may not be met.
Fuse 1-1.5A
L
VAC(L)
RAC04-C
Application Note
Vout+
MOV
Vout-
VAC(N)
N
Recommended external input fuse 1.0 - 1.5A / slow blow type.
An external MOV is required for 230VAC operation. (MOV model: shall comply with IEC61051-2, e.g. Epcos S14 Series)
Package Style and Pinning
23.90
37.80
16.40+0.25
-
15.65
5.0
6.10
5.08
0.75+0.25
17.78
1.0
2.54
1.20
1
Pin Connections
13 8.89 11.95
3
Bottom View
16
14 8.89
Leave
Clear
of PCB
Traces
+0.2/-0.1
16
14
13
1
3
Recommendend Footprint Details
2.54
Pin #
Single Out
1
VAC in (L)
3
VAC in (N)
13
NC
14
-VDC out
16
+VDC out
Tolerance ±0.5mm
Unless otherwise specified
The product information and specifications are subject to change without prior notice. RECOM products are not authorized for use in safety-critical applications (such as life support) without RECOM’s explicit
written consent. A safety-critical application is defined as an application where a failure of a RECOM product may reasonably be expected to endanger or cause loss of life, inflict bodily harm or damage property. The buyer
shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized use of RECOM products in such safety-critical applications.
www.recom-power.com
REV: 1/2015
PA-17