Features Regulated Converters Descritption ● ● ● ● ● ● ● POWERLINE Universal Input 80-264VAC or 115-370VDC Operating Temperature Range of -25°C to +85°C Isolated Output 3kVAC / 1 min Short Circuit and Overcurrent Protection Low Output Ripple & Noise Low Cost AC/DC Power Supply EN, UL and CE certified AC/DC-Converter with 3 year Warranty The new RAC04-SC modules are available with output voltages of 3.3, 5, 9, 12, 15, and 24V, and the input-to-output isolation is approximately 3kVAC/1min. With a standby consumption of typical 100mW, the mini power supplies are particularly suitable for energy-saving sleep mode and standby applications. Because of its compact design (height <17 mm), it is a versatile solution for home automation and other similar applications. Complete with an integrated input filter, the series has enhanced EMI performance and complies with EN55022, class B. The mini power supplies are also protected against short circuit with fully automatic restart after the error has been solved. The converters are EN/UL60950-1 certified and come complete with a 3 year warranty. 4 Watt Single Output Selection Guide Part Number RAC04-3.3SC Input Voltage (VAC) 80-264 Output Voltage (VDC) 3.3 Output Current max. (mA) 1200 Efficiency Typ. (%) 67 Max. Capacitive Load (1+2) 5600µF RAC04-05SC 80-264 5 800 72 2000µF RAC04-09SC 80-264 9 444 76 1500µF RAC04-12SC 80-264 12 333 74 560µF RAC04-15SC 80-264 15 267 77 470µF RAC04-24SC 80-264 24 167 77 150µF RoHS 2011/65/EU 6/6 Input Voltage Range (with Derating) 80-264VAC or 115-370VDC Input Frequency (for AC Input) 47-63Hz Input Current (Full Load) 115VAC / 230VAC 110mA / 72mA max. Inrush Current 115VAC / 230VAC 30A / 60A max. External Input Fuse Required Recommended Value 1A - 1.5A / Slow Blow Type No Load Power Consumption 80-264VAC 100mW typ. / 200mW max. Output Voltage (Vout nom.) 3.3V-24V Output Current Range 167mA - 1200mA Output Voltage Tolerance ±2% typ. / ±5% max. Minimum Load 10% min. Output Ripple & Noise (3) (Full Load)115VAC / 230VAC @ 20MHz limited 200mVp-p max. Line Voltage Regulation LL-HL at full Load ±0.5% typ. / ±1% max. Load Voltage Regulation 10%-100% Load ±1.5% typ. / ±5% max. Overcurrent LImit 105% - 155% Switching Frequency at Full Load 40kHz typ. Isolation Voltage Input-Output 3kVAC / 1 minute Leakage Current 0.85mA max. Isolation Resistance Input-Output 1G Ω min Isolation Capacitance Input-Output 1000pF typ. Short Circuit Protection Hiccup, Auto Restart Over Voltage Category OVC II (4) Operating Temperature Range natural convection, without derating -20°C to +60°C natural air convection, with derating -25°C to +85°C Storage Temperature Range -40°C to +100°C Case Material UL94V-0 black plastic Potting Material Silicone Relative Humidity 95% RH max. Package Weight 39g typ. Package Quantity 12 pcs continued on next page PA-16 REV: 1/2015 E224736 IEC-60950-1 certified UL-60950-1 certified RAC04-C Derating-Graph (Ambient Temperature) 120 100 Output Power (%) RAC04-C Specifications (measured at TA 25°C, nominal input voltage, full load after warm-up) 75 50 25 80 60 Safe Operating Area 40 20 0 -25 -20 0 20 40 60 70 80 100 85 Ambient Temperature Range (°C) www.recom-power.com RAC04-xxC Series POWERLINE AC/DC-Converter Specifications (measured at TA 25°C, nominal input voltage, full load after warm-up) Physical MTBF (+25°C) EMI Dimension (LxWxH) MIL-HDBK-217F Conducted and Radiated Noise Immunity Safety Standard CB UL General Safety 37.80 x 23.90 x 16.40 mm 500 * 103 hours EN55022, Class B EN55024 Report Number: 1111070-CB Report Number: E224736-A5-UL 115VAC IEC-60950-1, 2nd Edition UL-60950-1, 2nd Edition 230VAC 115VAC in (%) Input Voltage Derating Graph 230VAC in (%) 24V 80% 75% 5V 5V 70% 70% 90% 80V, 85% 80% 70% 3.3V 3.3V 65% 264V, 100% 90V, 100% 12V 12V 75% 100% 24V Load (%) 80% 65% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% Load (%) Load (%) 80 180 130 230 280 Input Voltage (VAC) Ta=25°C Notes: 1. Measured @230VAC / 50Hz 2. If used @ 115VAC / 60Hz with full load, please contact RECOM for detailed information. 3. To measure the output ripple & noise with short runs by 0.1uF/50V@20MHz, nominal input and full load. 4. Start up only is guaranteed at temperatures down to -25°C. Other specifications may not be met. Fuse 1-1.5A L VAC(L) RAC04-C Application Note Vout+ MOV Vout- VAC(N) N Recommended external input fuse 1.0 - 1.5A / slow blow type. An external MOV is required for 230VAC operation. (MOV model: shall comply with IEC61051-2, e.g. Epcos S14 Series) Package Style and Pinning 23.90 37.80 16.40+0.25 - 15.65 5.0 6.10 5.08 0.75+0.25 17.78 1.0 2.54 1.20 1 Pin Connections 13 8.89 11.95 3 Bottom View 16 14 8.89 Leave Clear of PCB Traces +0.2/-0.1 16 14 13 1 3 Recommendend Footprint Details 2.54 Pin # Single Out 1 VAC in (L) 3 VAC in (N) 13 NC 14 -VDC out 16 +VDC out Tolerance ±0.5mm Unless otherwise specified The product information and specifications are subject to change without prior notice. RECOM products are not authorized for use in safety-critical applications (such as life support) without RECOM’s explicit written consent. A safety-critical application is defined as an application where a failure of a RECOM product may reasonably be expected to endanger or cause loss of life, inflict bodily harm or damage property. The buyer shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized use of RECOM products in such safety-critical applications. www.recom-power.com REV: 1/2015 PA-17