RAC10-C/277 Series - recom

Features
Regulated
Converters
●
●
●
●
●
●
●
●
POWERLINE
Very Compact Low AC/DC Power Supply
High Efficiency
Single & Dual Output Options
Continuous Short Circuit Protection
Isolated Output 3.75kVAC/1 min
EN55022 Class B Compliant
High Operating Temperature
Low Standby Power Consumption
AC/DC-Converter
with 3 year Warranty
10 Watt
Single / Dual
Output
Selection Guide
Part
Number
Input
Range
(VAC)
Output
Voltage
(VDC)
Output
Current
(mA)
Efficiency
(typ.)
(%)
Max.
Capacitive Load
(1+2)
(µF)
RAC10-3.3SC/277
80-305
3.3
2500
75
50000
RAC10-05SC/277
80-305
5
2000
78
36000
RAC10-12SC/277
80-305
12
840
80
8600
RAC10-15SC/277
80-305
15
670
78
6000
RAC10-24SC/277
80-305
24
420
80
2700
RAC10-05DC/277
80-305
±5
±1000
77
±21000
RAC10-12DC/277
80-305
±12
±420
79
±3700
RAC10-15DC/277
80-305
±15
±340
79
±2900
RoHS
Specifications (measured at TA 25°C, full load after warm-up)
Input Voltage Range (with Derating)
2011/65/EU
6/6
80-305VAC or 113-430VDC
Rated Power
10 Watts
Input Frequency Range (for AC Input)
47-63Hz
115VAC
250mA typ.
230VAC
160mA typ.
No Load Power Consumption
230VAC
300mW max.
Inrush Current (cold Start-Up)
115VAC
15A max.
230VAC
Leakage Current
Output Voltage Accuracy
0.25mA max.
1.5A slow blow type
3.3V
±3% typ.
all others
±2% typ.
Line Voltage Regulation
(low line, high line at full load)
±0.3% typ.
Load Voltage Regulation
3.3V, 5V
-1.5% typ.
12V
±1% typ.
(0 -100% Load)
all others
±0.5% typ.
Minimum Load
Output Ripple and Noise
(with 0.1µF across outputs
@20mHz bandwidth)
0%
3.3V / 5V
50mVp-p typ.
12V / 15V / 24V
125mVp-p typ.
±5
200mVp-p typ.
±12
125mVp-p typ.
±15
200mVp-p typ.
Operating Frequency
Hold-up time
Isolation Voltage (input to output)
Short Circuit Protection
RAC10-C/277
30A max.
250VAC/50Hz
External Fuse Recommended
EN60950-1 Certified
UL60950-1 Certified
CE marked
Derating-Graph
(Ambient Temperature)
100
80
Load %
Input Current (full load)
E224736
60
40
20
0
-20
0
20
40
60
Temperature °C
70
80
100
100kHz
230VAC/50Hz
60ms min.
3.75kVAC / 1minute
Hiccup, Automatic Restart
continued on next page
Refer to Application Notes
www.recom-power.com
REV: 1/2015
PA-39
RAC10-xxS_DC
/277 Series
POWERLINE
AC/DC-Converter
Specifications (measured at TA 25°C, full load after warm-up)
Output Overvoltage Protection
Latch off
Over Voltage Category
OVC II
Overcurrent Protection
Automatic Recovery
Operating Temperature Range
(free air convection, with derating)
Input Voltage vs Load
-20°C to +70°C
Storage Temperature Range
-40°C to +7 5°C
100
Case Material
Epoxy with Fibreglass (UL94V-0)
80
Dimension (L x W x H)
52.4 x 27.4 x 23.5mm
Package Weight
62g±5g
Certifications
UL General Safety
IEC/EN General Safety
EMC
Report: E224736-A20
UL60950-1, 2nd Edition
Report: SPCLVD1210109
EN60950-1, 2nd Edition
Report: T121026N02-E
Output Power %
95% RH max.
Humidity
60
40
20
0
80
90 100 115
Input Voltage (VAC)
EN 55022 Class B
Report: T121026N02-E
EN 55024
MTBF (+25°C)
using MIL-HDBK-217F
320 x 103 hours
(+70°C)
using MIL-HDBK-217F
120 x 10³ hours
230 264 277 305
Notes:
Note1: Measured @ 230VAC / 50Hz / Ta=25°C with constant resistant mode at full load.
Note2: If used @ 115VAC / 60Hz with full load, max. capacitive load is less, please contace RECOM for detailed information.
Characteristics (measured @ 115/230VAC, 50/60Hz after warm up)
RAC10-xxDC/277
100
80
80
60
60
Efficiency (%)
100
Efficiency (%)
RAC10-C/277
RAC10-xxSC/277
40
RAC10-12SC/277
RAC10-15SC/277
RAC10-05SC/277
RAC10-3.3SC/277
RAC10-24SC/277
20
0
0
40
20
60
80
0
100
0
2
1,5
1,5
Deviation (%)
24V
0
-0,5
5V
-1
0
20
40
80
100
±15V
60
±5V
0,5
0
±12V
-0,5
-1
12V
-1,5
-2
60
1
3.3V
0,5
40
20
Load (%)
2
1
Deviation (%)
RAC10-12SC/277
RAC10-15SC/277
RAC10-05SC/277
20
Load (%)
-1,5
80
-2
100
Load (%)
PA-40
40
0
20
40
60
80
100
Load (%)
REV: 1/2015
www.recom-power.com
RAC10-xxS_DC
/277 Series
POWERLINE
AC/DC-Converter
Application Notes
Fuse
VAC in (L)
VDC out +
VAC in (N)
VDC out -
0.1uF/50V
1.5-2A Slow blow type
Ground Ring
Fuse
1. Recommended external input fuse 1.5A / slow blow type.
2. Do not use scope ground lead to measure the output
ripple & noise.
0.1uF/50V
VAC in (L) VDC out +
VDC out +
1.5-2A Slow blow type
COM
VDC out -
VAC in (N) VDC out -
0.1uF/50V
Standard Application Circuit
Fuse
L
VAC in (L)
VDC out +
LOAD
1.5-2A slow blow type
LOAD
COM
LOAD
N
VAC in (N)
VDC out -
DUAL
100VAC
115VAC
230VAC
277VAC
SINGLE
RAC10/277
Standard Package Style and Pinning
RAC10-xxSC/277
52.5
51.5
27.4
26.7
23.5
6.0
45.75
Æ1.0mm
10.16
2.54
1.2ø+0.2/-0.1
2
13.7 10.16
Bottom View
Top View
3
10.16
10.16
1
4
2.54
Recommended Footprint Details
www.recom-power.com
REV: 1/2015
Pin ConnectionsPin #
Single Out
1
VAC in (N)
2
VAC in (L)
3
-VDC out
4
+VDC out
XX.X ± 0.5 mm
XX.XX ± 0.25 mm
PA-41
RAC10-xxS_DC
/277 Series
POWERLINE
AC/DC-Converter
Standard Package Style and Pinning
RAC10-xxDC/277
52.5
51.5
27.4
26.7
23.5
6.0
10.16
45.75
Æ1.0mm
10.16
2.54
1.2ø+0.2/-0.1
3
2
13.7 10.16
10.16
Bottom View
Top View
4
10.16
10.16
1
5
Pin ConnectionsPin #
Single Out
1
VAC in (N)
2
VAC in (L)
3
-VDC out
4
COM
5
+VDC out
XX.X ± 0.5 mm
XX.XX ± 0.25 mm
2.54
RAC10/277
Recommended Footprint Details
The product information and specifications are subject to change without prior notice. RECOM products are not authorized for use in safety-critical applications (such as life support) without RECOM’s explicit
written consent. A safety-critical application is defined as an application where a failure of a RECOM product may reasonably be expected to endanger or cause loss of life, inflict bodily harm or damage property. The buyer
shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized use of RECOM products in such safety-critical applications.
PA-42
REV: 1/2015
www.recom-power.com