Spec

MF series : (MINI SIZE)
1. Features : A. Quick response
B. Small capacitance (1PE max.) and excellent insulstion resistance (100M Ω min.)
C. Low limiting voltage
D. Stable against repeated surges
E. No polarity
2. Applications : A. Devices connecting telecommunication telephone, fax, modem PBX ect…
B. Devices connecting antenna or signal line booster, radio cassette recorder, car
radio, wireless set.
C. Devices that need protection against electrostatic display units, monitor TV.
3. Part Number System :
MF——————201—————————M—————————2———————— A
SERIES
DC SPARK-OVER
VOLTAGE
DC SPAK-OVER
VOLTAGE TOLERANCE
141
140V
721
750V
L
201
200V
102
1000V
301
300V
122
1200V
M ±20%
N ±30%
401
400V
152
1500V
501
500V
±15%
SIZE
TAPING FORM
2 DO-35
4 DO-41
A AXIAL TAPING
R RIDAIL TAPING
4. Initial Characteristics :
TYPE
DISCHARGE VOLT
(DC) 1mA/LESS 1 SEC
VS (V)
INSULATION
RESISTANCE IR Ω
CAPACITANCE
1KHZ/LESS 6V
MF- 141N
140 ( 98 ~ 182 )
100MΩ≦( DC 50V )
< 1pF
MF- 201M
200 ( 160 ~ 240 )
100MΩ≦( DC 100V )
< 1pF
MF- 301N
300 ( 210 ~ 390 )
100MΩ≦( DC 100V )
< 1pF
MF- 401N
400 ( 280 ~ 520 )
100MΩ≦( DC 250V )
< 1pF
MF- 501N
500 ( 350 ~ 650 )
100MΩ≦( DC 250V )
< 1pF
MF- 751N
750 ( 525 ~ 975 )
100MΩ≦( DC 250V )
< 1pF
MF-102N
1000 ( 700 ~ 1300 )
100MΩ≦( DC 500V )
< 1pF
MF- 122N
1200 ( 840 ~ 1560 )
100MΩ≦( DC 500V )
< 1pF
MF- 152N
1500 ( 1050 ~ 1950 )
100MΩ≦( DC 500V )
< 1pF
5. Characteristics and Test Methods :
ITEM
STATIC LIFE
COLD
RESISTANCE
HEAT
RESISTANCE
HUMIDITY
RESISTANCE
TEST METHOD
10KV WITH 1500pF CONDENSER IS
DISCHARGED THROUGH 2K Ω
RESISTOR 200 TIMES AT AN
INTERVAL OF 10 SEC.
STANDARD
RATE-OF-CHANGE, WITHIN
±30%. INSULATION
RES-ISTANCE &
CAPACITANCE, CONFORMED
TO RATED SPEC
MEASUREMENT AFTER -40℃/1000
HRS & NORMAL TEMPERATURE/2
HRS.
MEASUREMENT AFTER -125℃/1000
HRS & NORMAL TEMPERATURE/2
HRS.
FEATURES ARE CONFORMED
MEASUREMENT AFTER HUMIDITY
TO RATED SPEC.
90~95℃ (45℃)/1000 HRS & NORMAL
TEMP/2 HRS.
10 TIMES REPETITION OF CYCLE -40
TEMPERATURE ℃/30 MIN→NORMAL TEMP/2 MIN→
125℃/30 MIN, MEASUREMENT
CYCLE
AFTER NORMAL TEMP/2 HRS.
APPLY FLUX AND IMMERSE IN
MOLTEN SOLDER260±5℃ SOLDER
SOLDERABLITY FOR 3 SEC UP TO THE POINT OF
1.5MM FROM DODY. CHECK FOR
SOLDER ADHESION.
SOLDER HEAT
LEAD WIRE IS EVENLY
COVERED BY SOLDER.
MEASUREMENT AFTER LEAD WIRE
IS DIPPED UP TO THE POINT OF
CONFORMED TO RATED
1.5MM FROM DODY INTO 260±5℃
SPEC.
SOLDER ADHESION.
PULL STRENGTH APPLY O.5KG LOAD FOR 10 SEC.
FLEXURAL
STRENGTH
LEAD SEALL NOT PULL OUT
BEND LEAD WIRE AT THE POINT OF
OR SNAP.
2MM FROM BODY UNDER 0.25
LOAD AND BACK TO ITS ORIGINAL
POINT. REPEAT 1 TIME.
6.SCOPE :
This specification covers the MF.SURGE SUPPRESSOR series for manufacturing gas tube
arrestors with the micro-gap system.
7.PERFORMANCE :
No
1
Item
Standard test
condition
Test condition
Standard condition/temperature: 5~35℃
Best condition
Requirements
humidity : 45~85%RH.
/temperature: 25℃
humidity : 65%RH.
2
Appearance
Outer appearance shall be visually examined.
No visual damage
3
DC Sparkover
voltage
Measure starting discharge voltage by gradually
increasing applied DC voltage. Test current is
1mA max. and test period is 1 second max.
Meet specified value
4
Insulation resistance Measure the insulation resistance across the
terminal at regulated voltage.
5
Electrostatic
capacitance
6
Cold resistance
7
Heat resistance
100MΩ
Measure the electrostatic capacitance by applying 1pF or less
a voltage of less than 6V (at 1KHZ) between
terminals.
The specimen shall be subjected to -55±3℃ for Meet specified value
1000 hours without load and then stored at room
temperature and humidity for 4 hours.
Thereafter, the characteristics of items 2,3,4 and 5
shall be measured.
(in accordance with JIS C 0020)
The specimen shall be subjected to 125±2℃ for Meet specified value
1000 hours without load and then stored at room
temperature and humidity for 4 hours.
Thereafter, the characteristics of items 2,3,4 and 5
shall be measured.
(in accordance with JIS C 0021)
No
8
9
Item
Test condition
Requirements
Humidity resistance The specimen shall be subjected to 85±2℃ for
Meet specified value
1000 hours without load and then strored at room
temperature and humidity for 4 hours.
Thereafter, the characteristics of items 2,3,4 and 5
shall be measured.
(in accordance with JIS C 0021)
Temperature cycle
Repeat the temperature cycle shown below 25
Meet specified value
times then store parts at room temperature and
humidity for 4 hours.
Thereafter, the characteristics of items 2,3,4 and 5
shall be measured.
Step
1
2
Temperature
-55±3℃
Period
30minutes
3
Room Temp.
125±2℃
3minutes
30minutes
4
Room Temp
3minutes
(in accordance with JIS C 0025)
10 Vibration
The specimen shall be vibrated by its lead wires
Meet specified value
with a total amplitude of 1.5mm and a varying
frequency of 10~55~10HZ (each minute) for a
period of 60 minutes
respectively in each X,Y and Z directions.
Thereafter, the characteristics of items 2,3,4 and 5
shall be measured.
(in accordance with JIS C 0040)
11 Lead wire pull
strength
After gradually applying a 0.51kgf load, keep the Meet specified value
unit fixed for 30 seconds.
Thereafter, the characteristics of items 2,3,4 and 5
shall be measured.
(in accordance with JIS C 0051)
No
Item
Test condition
Requirements
12 Lead wire bending The unit shall be second with its lead wire kept
Meet specified value
strength
vertical and a 0.25kgf weight applied below in the
axial direction. The lead wire shall gradually be
bent to 90℃ in one direction at a point of 3mm from
the body along the radius of curvature
(0.75~0.80mm), and again back to the original'
position.
This shall be repeated 2 times.
Thereafter, the characteristics of item 2,3,4 and shall
be measured.
(in accordance with JIS C 0051)
13 Solderability
After dipping the lead wire within 3mm of the body Lead wire is almost
in 260±5℃ solder for 5±0.5 seconds, the lead wire evenly covered with
shall be visually examined.
solder.
(in accordance with JIS C 0050, 4-6)
14 Resistance to
soldering heat
After dipping the lead wire within 3mm of the body Meet specified value
in 350±10℃ solder for 3±1 seconds, the
characteristics of items 2,3,4 and 5 shall be
measured.
(in accordance with JIS C 0050)
15 Surge life test
Apply a standard impulse voltage (10×1000)µ sec.)
of 1000V for 6 times with an interval of 30 seconds.
Then change the polarity of the surge and apply the
impulse again for another 6 times. And similarly,
apply a impulse voltage ((100×1000) µ sec.) of
1000 V.
Total number of a impulse voltage applied is 24
times. Thereafter, the characteristics of items 2,3,4
and 5 shall be measured.
(See figure 1)
16 Surge current
capacity
Apply standard impulse current (8×20)µ sec) of
500A for 3 times with an interval of 5 minutes
between each impulse.
|ΔVs/Vs|≤30%
Characteristics of
items 1,3 and 4 must
meet the specified
value.
No cracks and wire
breaking
8. Dimensions: UNIT mm :
( 102 、122、152 )
9.Marking :
Color CODE
Part number
141 Brown + Yellow
141N
201 Red
201N
301 Orange
301N
401 Yellow
401N
501 Green
501N
102 Brown + Black
102N
122 10
Brown + rED
Red
122N
152 Brown + Green
152N