AC/DC Power Modules TMM 60 Series, 60 Watt CB Scheme Features ◆ Fully encapsulated low profile plastic UL 508 UL 60950-1 ES 60601-1 UL 60950-1 UL 60601-1 casing in PCB- or chassis mount version ◆ 2 x MOPP Medical safety according to AAMI/ANSI ES 60601-1:2005(R) and IEC/EN 60601-1 3rd edition ◆ IT and industrial safety according to IEC/UL 60950-1 and UL 508 ◆ Ready to meet ErP directive <0.5 W no load power consumption ◆ -40°C start-up temperature ◆ Safety class II prepared ◆ Protection against over-temperature overload and short circuit ◆ 3-year product warranty Also see: TMM 24 Series, 24 Watt www.tracopower.com/products/tmm24.pdf TMM 40 Series, 40 Watt www.tracopower.com/products/tmm40.pdf The TMM 60 Series of fully encapsulated 60 Watt AC/DC power supply modules feature a reinforced/double I/O isolation system according to latest medical safety standards 60601-3 3rd edition for 2 x MOPP (Means Of Patient Protection). The high efficiency and the use of highest grade components make the units suitable for an operating temperature range of –40°C to +60°C while it goes up to 75°C with 50% load derating. EMI/EMC characteristics and the safety approval package qualify these modules not only for medical devices but also for demanding applications in transportation systems and for equipment in industrial an commercial environment. Models Order code Output power max. Output Efficiency PCB mount Chassis mount TMM 60105 TMM 60105C 5.1 VDC / 10000 mA 84 % TMM 60112 TMM 60112C 12 VDC / 5000 mA 87 % TMM 60115 TMM 60115C 15 VDC / 4000 mA 87 % 60 W TMM 60124 TMM 60124C 24 VDC / 2500 mA 87 % TMM 60148 TMM 60148C 48 VDC / 1250 mA 88 % http://www.tracopower.com Page 1 of 5 AC/DC Power Modules TMM 60 Series 60 Watt Input Specifications Input voltage ranges – nominal 100 – 240 VAC – AC input 85 – 264 VAC – DC Input 120 – 370 VDC Input frequency 47 – 440 Hz Input current at full load (115 VAC / 230 VAC nominal input) 5.1 VDC model: 860 mA / 515 mA typ. other models: 1000 mA / 600 mA typ Leakage current 80 µA typ. No-Load power consumption <0.5 W External input fuse required (recommended value) 3 A slow blow type or characteristic C Output Specifications Voltage set accuracy ±1% typ. / 2.0 % max. Minimum load no minimum load required Regulation – Input variation 0.2% typ. / 1.0 % max. – Load variation (0-100%) : 0.5% typ. / 1.0 % max. Temperature coefficient 0.02 %/K Ripple and noise (20 MHz bandwidth) (measured with capacitor 0.1µF/50V MLCC and 1µ/50V e-cap) 5.1 VDC model: 3% of Vout [Vp-p] max. other models: 1.5% of Vout [Vp-p] max. Current limitation above 105 % of rated output current. hiccup, auto recovery Overvoltage protection by Zehner diode (main output only) 120 % of Vout typ. Short circuit protection continous Max. capacitive load 5.1 12 15 24 48 VDC VDC VDC VDC VDC model: model: model: model: model: 8000 µF 3900 µF 3300 µF 1500 µF 680 µF All specifications valid at nominal input voltage, full load and +25°C after warm-up time unless otherwise stated. http://www.tracopower.com Page 2 of 5 AC/DC Power Modules TMM 60 Series 60 Watt General Specifications Temperature ranges – Operating (natural convection cooling 20 LFM) –40°C to +75°C – Power derating above +60°C 3.75 %/K – Storage (non operating) –40°C to +95°C Humidity (non condensing) 95 % rel max. Altitude during operation 5000 m Switching frequency (pulse width modulation PWM) 100 kHz typ. Hold-up time 115 VAC: 20 ms typ. 230 VAC: 80 ms typ. Isolation voltage – Input/Output 4‘000 VAC Isolation resistance – at 500 VDC 1‘000 MOhm Reliability /calculated MTBF (MIL-HDBK-217F, at +25°C, ground benign) >125’000 h EMI / RFI conducted and radiated EN 55022, class B, FCC part 15, level B EN 55011 class B Electromagnets compatibility – Electrostatic discharge ESD (EMC), immunity – RF field immunity – Electrical fast transients/burst immunity – Surge – Conducted RF – Magnetic field immunity IEC / EN 61000-4-2, 8kV/4kV perf. criteria A IEC / EN 61000-4-3, 10V/m perf. criteria A IEC / EN 61000-4-4, ±2kV perf. criteria A IEC / EN 61000-4-5, ±1kV perf. criteria A IEC / EN 61000-4-6, 10 Vr.m.s perf. criteria A IEC / EN 61000-4-8, 30A/m perf. criteria A Voltage dip and interruptions according to EN 61000-4-11 30%, 10ms perf. criteria A reference: 115 VAC / 60Hz 60%, 100ms perf. criteria A 95%, 5000ms perf. criteria B Protection class II according IEC/EN 60536 Safety standards UL 60950-1, IEC/EN 60950-1, IEC/EN 60601-1 3rd edition, 2 x MOPP ANSI/AAMI ES60601-1:2005(R)2012 UL 508 for chassis mount version – Certification documents www.tracopower.com/overview/tmm60 Casing material plastic resin (UL 94V-0 rated) Environmental compliance – Reach www.tracopower.com/overview/tmm60 – RoHS RoHS directive 2011/65/EU All specifications valid at nominal input voltage, full load and +25°C after warm-up time unless otherwise stated. http://www.tracopower.com Page 3 of 5 AC/DC Power Modules TMM 60 Series 60 Watt DIN-Rail Mounting Kit Adapter for mounting on DIN-rails as per EN 50022-35 (snap-on mounting) DIN-Rail Mounting Kit Order code For models TMP-MK2 TMM 60xxxC Kit contains interface plate, DIN-rail clip and necessary screws. All specifications valid at nominal input voltage, full load and +25°C after warm-up time unless otherwise stated. http://www.tracopower.com Page 4 of 5 AC/DC Power Modules TMM 60 Series 60 Watt Outline Dimensions TMM 60: for PCB mount: 67.5 (2.66) 12.70 12.70 (0.50) (0.50) 36.45 (1.44) 88.9 (3.50) 2 x M4 THD Bottom view 81.3 (3.20) 4 17.0 (0.67) 6 34.2 (1.35) 3.85 17.5 (0.70) 27.94 (1.10) (0.15) 1 2 0.7 (0.03) 6.0 (0.24) 27.94 (1.10) 33.75 (1.33) Weight: 360 g (12.70oz) Pin diameter ø 1.0 mm (0.039) TMM 60C: for chassis mount: 67.8 (2.67) 38.0 (1.50) 50.0 (1.97) 3 4 5 6 8.9 5.0 11.8 (0.35) (0.20) (0.46) Pinout / Connection 7 4 x ø3.5 90.0 (3.54) Single 1 AC (N) 2 AC (L) 3 No Pin / NC 4 +Vout 5 No Pin / NC 6 -Vout 7 No Pin / NC NC = not to connect 11.0 Weight: 380 g (13.4oz) (0.43) 6.0 2 (0.24) 1 112.0 (4.41) Top view 100.0 (3.94) Indication LED Pin/con. Dimensions in[mm], () = Inches Tolerances = ±1.0 mm (0.04) Pin diameter ø ±0.1 mm (0.004) Specifications can be changed without notice! Make sure you are using the latest documentation, downloadable at www.tracopower.com www.tracopower.com http://www.tracopower.com Rev. April 20. 2015 Page 5 of 5