Industrial Power Supplies TSP-Series CB Innovative and Powerful Features! ◆ Rugged metal case for EMC LVD harsh industrial environments Scheme IEC 60950-1 UL 60950-1 UL 508 UL 60079-15 ATEX II3G ◆ Shock and vibration proof ◆ Worlwide Safety approval package. ◆ ATEX certification tested in accordance to IECEX (opt. EX) ◆ Model TSP 090-124N meets NEC class 2 ◆ Industrial operating temperature range: –25°C to +70°C ◆ Adjustable output voltage ◆ Protection against short-circuit, overvoltage and over-temperature ◆ Power OK signal, Remote On/Off ◆ Wall mounting (opt.) ◆ 3-year product warranty Function Modules (see page 5) The TSP series comprises high performance DIN-rail mount power supplies designed for reliable operation under difficult factory floor conditions. High immunity against electrical disturbances and rugged metal casing make these modules the best choice to power sensitive loads in industrial process control systems, machine tools or other demanding industrial applications. They provide a DC-OK signal and external shut down function. Detachable screw terminal blocks make the connection easy. This power supply line is accompanied by a wide range of function modules for reliable system solutions: Redundancy modules for true current sharing in parallel operation and for redundant systems. Battery controller modules to configure high reliable UPS systems for 12, 24 and 48 VDC. Selection of battery packs available. Buffer modules for protection against short time AC power loss. Maintenance free! No batteries required. Models Order Code Output Power (Pmax) **Output Voltage (Vnom) ***Output Current (Imax) TSP 070–112* 72 W 12 VDC 6.0 A TSP 090–124* 90 W 24 VDC 3.75 A TSP 090–124N 90 W 24 VDC 3.75 A TSP 090–148* 96 W 48 VDC 2.0 A TSP 140–112* 144 W 12 VDC 12.0 A TSP 180–124* 180 W 24 VDC 7.5 A TSP 180–148* 192 W 48 VDC 4.0 A TSP 360–124* 24 VDC 15.0 A TSP 360–148* 48 VDC 7.5 A TSP 600–124* 24 VDC 25.0 A TSP 600–136 36 VDC 16.5 A TSP 600–148* 48 VDC 12.5 A 360 W 600 W * For ATEX compliant models add appendix -EX to order code. ** Output voltage adjustable 12–14 VDC, 24–28 VDC and 48–56VDC *** Max. current at nominal output voltage and operating temperature up to +40°C max. http://www.tracopower.com Page 1 of 9 Industrial Power Supplies TSP Series 70–600 Watt Input Specifications Input voltage range TSP 070/090 85 – 264 VAC universal input other models: 85 – 132 / 187 – 264 VAC autoselect output current derating at operation below 100 VAC see graph B, page 4 Input voltage frequency 47 – 63 Hz Harmonic limits EN 61000-3-2, Class A (for limited output power) Holdup time 230 VAC 20 ms 115 VAC 10 ms at full load, 20 ms at 66% load Inrush current TSP 070/090 TSP 140/180 TSP 360 TSP 600 115 VAC < 12 A < 13 A < 16 A < 25 A 230 VAC < 20 A < 25 A < 25 A < 30 A Recommended circuit breaker, TSP 070/090/140/180 6.0 – 16.0 A characteristic B TSP 360 10.0 – 16.0 A TSP 600 16.0 – 25.0 A Efficiency 87 % typ. Output Specifications Output voltage adj. range 12 VDC models: 12 – 14 VDC 24 VDC models: 24 – 28 VDC 36 VDC model: 36 – 42 VDC 48 VDC models: 48 – 56 VDC At output voltage higher than nominal output voltage max. output current has to be reduced accordingly, in order not to exceed max. output power. Regulation – Input variation 0.5 % max. – Load variation (10–100 %) 0.5 % max. Ripple and Noise (20MHz bandwidth) 100 mV pk-pk typ. (200 mV pk-pk max. at Imax) Electronic short circuit protection current limitation at Imax. constant current, automatic recovery Output overvoltage protection 12 VDC models: 24 VDC models: 36 VDC model: 48 VDC models: 20 V 35 V 43 V 60 V Overload protection electronic overload protection Overtemperature protection switch off at overtemperature, automatic restart Power back immunity 12 VDC models: 24 VDC models: 36 VDC model: 48 VDC models: 16 V 35 V 48 V 63 V Status indicator dual color LED (green: DC ok, red: DC off) Power OK signal – trigger threshold: 12 VDC models: 9 – 11 V 24 VDC models: 18 – 22 V 36 VDC model: 27 – 34 V 48 VDC models: 36 – 46 V – active output signal: 12 VDC models: 11.0 V ±1.0 V (reference to –Vout) (20 mA max. for TSP 070, 40 mA max. for TSP 140) 24 VDC models: 22.0 V ±2.0V / 20 mA max. (10 mA max. for TSP 090, 20mA max. for others) 36 VDC model: 34.0 V ±2.0 V / 20 mA max. 48 VDC models: 44.0 V ±4.0 V / 15 mA max. – relay output DC OK = contact closed rated: 30 VDC/1.0 A for 12/24 VDC models rated: 30 VDC/2.0 A for 36 VDC model rated: 48 VDC/0.5 A for 48 VDC models http://www.tracopower.com Page 2 of 9 Industrial Power Supplies TSP Series 70–600 Watt General Specifications Max. capacitive load unlimited Temperature range – Operating –25°C to +70°C max. (for derating see graph A on page 4) – Storage –25°C to +85°C Cooling convection cooling, no internal fan Humidity (non condensing) 95 % rel. H max. Pollution degree 2 Temperature coefficient 0.02 %/K Reliability, calculated MTBF (at +25°C acc. to IEC 61709) – TSP 070/090 >1.8 Mio h – TSP 140 >1.2 Mio h – TSP 180/360/600 >0.9 Mio h Remote On/Off by ext. contact. DC on: -S contact open DC off: -S connectetd via 1Kohm to -Vout Isolation according to IEC/EN 60950-1, UL 60950-1, UL 508 IEC/EN 60950-1, UL 60950-1, CSA-C22.2 No. 60950-1-03 Safety standards – Information technology equipment – Industrial control equipment UL 508, CSA-C22.2 No. 107 – Electrical equipment for machines EN 60204 – Electronic equipment for power installation EN 50178 – Safety transformers for SMPS EN 61558-2-16 – Limited power source (model TSP 090-124N) EN 60950 sect. 2.5 and NEC Class 2 – Control equipment for hazardous location UL 60079-15 (Class I, Division 2, Groups A,B,C,D AEx n C II C T4 U) IEC/EN 60079-15 (Class I, Zone 2, EEx nC II C T4 U), ( II3G EEX nAC IIC T4 (T3 with limited power) Safety approvals and – CB report for IEC/EN 60950-1 certifications www.tracopower.com/products/tsp-cb.pdf – UL approvals UL 60950-1 rec. File: e181381, UL 508C listed File: e210002 www.ul.com -> certifications – CSA certification (file no. 219759) for UL 60950-1, UL 508, UL 60079-15-02, ANSI/ISA 12.12.01, CSA-22.2 No. 60950-1-03, CSA C22.2 No. 107, CSA 60079-15-02 www.tracopower.com/products/tsp-csa.pdf II3G ATEX 94/9/EC certificate no. EPS 12 ATEX 1 424 X (option -EX only) – www.tracopower.com/products/tsp-atex.pdf – BG certification EN 60950-1, EN 60204-1, EN 61558-2-16, EN 50178 www.tracopower.com/products/tsp-bg.pdf Class of protection safety class I (IEC 536) Degree of protection IP 20 (IEC/EN 60529) Electromagnetic compatibility (EMC), Emissions EN 61000-6-3, EN 61204-3 – Conducted RI suppression on input EN 55011 class B, EN 55022 class B, – Radiated RI suppression EN 55011 class B, EN 55022 class B, Electromagnetic compatibility (EMC), Immunity EN 61000-6-2, EN 61204-3 – Electrostatic discharge (ESD) IEC / EN 61000-4-2 4 kV / 8 kV criteria B – Radiated RF field immunity IEC / EN 61000-4-3 10 V / m criteria A – Electrical fast transient / burst immunity IEC / EN 61000-4-4 2 kV criteria B – Surge immunity IEC / EN 61000-4-5 1 kV / 2 kV criteria B – Immunity to conducted RF disturbances IEC / EN 61000-4-6 10 V criteria A – Power frequency field immunity IEC / EN 61000-4-8 30 A / m criteria A – Mains voltage dips and interruptions IEC / EN 61000-4-11 criteria B/C – Voltage sag immunity SEMI F47 www.tracopower.com/products/TSP_SemiF47.pdf http://www.tracopower.com Page 3 of 9 Industrial Power Supplies TSP Series 70–600 Watt General Specifications Environment – Vibration acc. IEC 60068-2-6; 3 axis, sine sweep, 10 – 55 Hz, 1 g, 1 oct/min – Shock acc. IEC 60068-2-27 3 axis, 15 g half sine, 11 ms Enclosure material aluminium (chassis) / stainless steel (cover) Mounting – DIN-rail mounting for DIN-rails as per EN 50022-35x15/7.5 (snap-on with self-locking spring) – Wall mounting (option) with wall mounting bracket - see page 9 Connection detachable screw terminals (plugs included) 2 terminals per output Remote On/Off connection – 2 pin molex male terminal KK series mating connector information (cable not included) www.tracopower.com/products/tsp-rc-cable.pdf Installation instructions www.tracopower.com/products/tsp-inst.pdf Output Power Derating A) B) Output Power Derating vs Ambient Temperature 100 100 90 80 TSP 600 70 TSP 070 TSP 140 TSP 090 TSP 180 TSP 360 60 50 40 50 Temperature [°C] 60 70 Output Power [% Pmax] Output Power [% Pmax] 90 40 -25 Output Power Derating vs Input Voltage 80 70 60 50 40 85 90 100 110 115 132 187 Input Voltage [VAC] 230 264 All specifications valid at nominal input voltage, full load and +25°C after warm-up time unless otherwise stated. http://www.tracopower.com Page 4 of 9 Industrial Power Supplies TSP Series 70–600 Watt Function Modules Overview Redundancy Module: With this module and two power supplies of the TSP series a highly reliable, true redundant power system can be configured without any additional components. This module provides: TSP-REM360 – Operation with true current sharing – Alarm outputs and redundancy OK signal – Hot swappable inputs can be loaded up to 15 A each (resp. 25 A with model TSP REM600) TSP-REM600 Models Order Code Output Voltage adj. Output Power TSP–REM360 24 VDC (24 – 27 VDC) 360 W TSP–REM600 600 W TSP-REM datasheet: www.tracopower.com/products/tsp-rem.pdf Battery Controller Modules + Batteries: This module provides a professional battery controller to charge and monitor an external lead-acid battery. Together with a power supply of the TSP series and a battery pack a perfect DC-UPS system can be configured. This module provides: - Battery protection for over voltage, deep discharge, short circuit and reverse connection - Remote On/Off for battery and power supply - Alarm outputs for input, output and battery condition - Controlled end of charge voltage by temperature sensor - Redundant inputs for two indepedant sources (TSP-BCMU360 only) TSP-BCM12 TSP-BCM24 TSP-BCM48 TSP-BCM24A TSP-BCM48A Models Order Code Output Voltage Output Power TSP-BCM12 12 VDC 180 W TSP–BCM24 TSP-BCM24A TSP–BCM48 TSP-BCM48A TSP-BCMU360 24 VDC 48 VDC 24/48 VDC 360 W TSP-BCMU360 600 W 360 W 600 W TSP-BCM datasheet: www.tracopower.com/products/tsp-bcm.pdf 360 W TSP-BCMU datasheet: www.tracopower.com/products/tsp-bcmu.pdf Buffer Module: This module will maintain the output voltage of a 24 VDC power supply during typical mains faults, short time blackouts or voltage dips of up to ten full 50 Hz cycles. During this buffer period no deterioration of the 24 VDC output voltage will occur. This module provides: TSP-BFM24 - Capacitor bank for energy storage, no battery needed! - Maintenance free, long lifetime, high performance also at low temperature. - Guaranteed Hold-up-time 200 ms/25 A to 4 s/1.2 A max. - Output 24 to 28 VDC, 600 W max. - Active ready and inhibit signals Models Order Code Output Voltage Output Power TSP–BFM24 24 – 28VDC 600 W http://www.tracopower.com TSP-BFM datasheet: www.tracopower.com/products/tsp-bfm.pdf Page 5 of 9 Industrial Power Supplies TSP Series 70–600 Watt Outline Dimensions 110.0 (1.38) (4.33) DC OK DC ON 80.0 (3.15) 110.0 (4.33) O/P ADJ. PE N L 25.0 (0.20) Fuction Modules: TSP-REM360 TSP-BCM12 TSP-BCM24 TSP-BCM48 35.0 38.5 (1.52) Models: TSP 070/090 5.0 5.0 (0.98) (0.20) P/S P S Remote Weight: 0.5kg (1.0lb) 110.0 (2.13) DC OK DC ON (4.33) 80.0 (3.15) 110.0 (4.33) O/P ADJ. L 25.0 5.0 (0.98) Remote 14.5 (0.57) S P PE N (0.20) Fuction Modules: TSP-REM600 TSP-BCM24A TSP-BCM48A TSP-BCMU360 TSP-BFM24 54.0 38.5 (1.52) Models: TSP 140/180 P/S Weight: 0.7kg (1.4lb) http://www.tracopower.com Dimensions in [mm], () = inch Tolerances: ±0.5 mm (±0.02) Page 6 of 9 Industrial Power Supplies TSP Series 70–600 Watt Outline Dimensions Models: TSP 360 125.0 (3.15) (4.92) 45.0 (1.77) 80.0 DC OK DC ON 86.5 (3.41) 125.0 (4.92) O/P ADJ. PE N L 46.0 5.0 (0.20) (1.81) 25.0 (0.98) 17.0 (0.67) 25.0 (0.98) Remote P S P/S Weight: 1.1kg (2.4lb) Dimensions in [mm], () = inch Tolerances: ±0.5 mm (±0.02) http://www.tracopower.com Page 7 of 9 Industrial Power Supplies TSP Series 70–600 Watt Outline Dimensions Models: TSP 600 P/S Remote P S 25.0 25.0 (0.98) (0.98) 21.0 123.0 (4.84) 125.0 (6.50) (4.92) DC ON DC OK PE N 86.5 (3.41) 125.0 (4.92) 45.0 (1.77) 165.0 (0.83) O/P ADJ. L Weight: 2.8kg (6.0lb) Dimensions in [mm], () = inch Tolerances: ±0.5 mm (±0.02) http://www.tracopower.com Page 8 of 9 Industrial Power Supplies TSP Series 70–600 Watt Outline Dimensions mm (inches) TSP–WMK Wall Mounting Bracket Ordercode of Kit For Models Content of Kit TSP-WMK03 TSP-WMK02 TSP 070, TSP 090, TSP 140, TSP 180 1 bracket TSP 360, TSP 600 2 brackets TSP-WMK03 85.0 (3.35) 42.5 (1.67) 34.5 (1.36) 34.5 (1.36) R 2.12 (0.083) 7.0 (0.28) 15.0 (0.59) 37.0 (1.45) 25.0 (0.98) 25.0 (0.98) 74.0 (2.91) 2.0 (0.08) 55.0 (2.16) 4 x positioning holes 2.0 (0.08) 2.0 (0.08) R 2.12 (0.083) TSP 070 TSP 090 TSP 140 TSP 180 2.0 (0.08) ø 4.25 (0.17) R 2.12 (0.083) ø 4.25 (0.17) R 2.12 (0.083) ø 4.25 (0.17) 15.0 (0.59) Material: 2 mm Mild Steel Tolerance: ±0.1mm (± 0.004) TSP-WMK02 46.0 (1.81) TSP 360 33.0 (1.30) 96.0 (3.78) 62.5 (2.46) 50.0 (1.97) ø 4.3 (0.17) 2x ø4.3 (0.17) 2.0 (0.08) 30.0 (1.18) 2.0 (0.08) 25 (0.98) 4 x positioning holes TSP 600 Material: 2 mm Mild Steel Tolerance: ±0.1mm (± 0.004) 62.5 (2.46) 15.0 (0.59) 7.0 (0.28) 173.0 (6.81) Dimensions: [mm] ( ) = Inch Dimensions in [mm], ( ) = Inch Tolerances: ±0.5 mm (±0.02) Specifications can be changed without notice! Make sure you are using the latest documentation, downloadable at www.tracopower.com www.tracopower.com Rev. August 17. 2015 Page 9 of 9