DC/DC Converters
TRA 1 Series, 1 Watt
CB
Scheme
Features
◆ Semi-regulated output (load)
◆ Industry standard pinout
◆ High efficiency up to 88%
◆ Single and dual output models
◆ I/O isolation voltage 1000 VDC
◆ Operationally reliable up to 5‘000m UL 60950-1
altitude
◆ Operating temperature range
–40°C to +85°C
◆ 3-year product warranty
The TRA 1 series are miniature, I/O-isolated 1W DC/DC-converters with a semi
load regulation. They are the ideal solution to power drivers and circuits where
unregulated DC/DC converters do not meet the input voltage range at load change.
Models
Order code
Input voltage
Output voltage
Output current
max.
Load regulation
max.
Efficiency typ.
TRA 1- 0511
5 VDC
200 mA
6.5 %
84 %
TRA 1- 0519
9 VDC
110 mA
5%
87 %
TRA 1- 0512
12 VDC
84 mA
5.2 %
87 %
15 VDC
67 mA
5%
87 %
TRA 1- 0513
5 VDC ±10%
TRA 1- 0521
±5 VDC
±100 mA
5.2 %
84 %
TRA 1- 0522
±12 VDC
±42 mA
4.6 %
86 %
TRA 1- 0523
±15 VDC
±34 mA
4.5 %
86 %
TRA 1- 1211
5 VDC
200 mA
5%
84 %
TRA 1- 1219
9 VDC
110 mA
3.4 %
86 %
12 VDC
84 mA
3.4 %
88 %
15 VDC
67 mA
2.7 %
88 %
TRA 1- 1221
±5 VDC
±100 mA
3.9 %
84 %
TRA 1- 1222
±12 VDC
±42 mA
2.9 %
88 %
TRA 1- 1223
±15 VDC
±34 mA
2.6 %
87 %
TRA 1- 2411
5 VDC
200 mA
3.7 %
84 %
TRA 1- 2419
9 VDC
110 mA
2.5 %
86 %
TRA 1- 2412
12 VDC
84 mA
2.4 %
87 %
15 VDC
67 mA
2.3 %
87 %
TRA 1- 1212
TRA 1- 1213
TRA 1- 2413
12 VDC ±10%
24 VDC ±10%
TRA 1- 2421
±5 VDC
±100 mA
3.7 %
83 %
TRA 1- 2422
±12 VDC
±42 mA
2.4 %
87 %
TRA 1- 2423
±15 VDC
±34 mA
2.3 %
87 %
http://www.tracopower.com
Page 1 of 3
DC/DC Converters
TRA 1 Series
1 Watt
Input Specifications
Input current no load / full load 5 Vin models 30 mA / 240 mA typ.
12 Vin models 12 mA / 100 mA typ.
24 Vin models 11 mA / 50 mA typ.
Surge voltage (1 sec. max.)
5 Vin models 9 V max.
12 Vin models 18 V max.
24 Vin models 30 V max.
Reflected input ripple current
12 Vin models 4 mA typ.
other models 8 mA typ.
Input filter internal capacitor
Reverse voltage protection 0.3 A max.
Recommended input fuse (slow blow type)
5 Vin models: 500 mA
12 Vin models: 200 mA
24 Vin models: 100 mA
Output Specifications
Voltage balance (dual output models) 1 % max.
Regulation
– Input variation 1.05 % / 1 % change of Vin
– Load variation see graph 1 on page 3
Ripple and noise (20 MHz Bandwidth) 60 mV pk-pk max.
Temperature coefficient ± 0.02 %/K
Short circuit limited 0.5 sec. max.
Capacitive load
single output models:220 µF max.
dual output models:100 µF max. (each output)
General Specifications
Temperature ranges
– Operating –40°C to +85°C (without derating)
– Case temperature +105°C max.
– Storage –50°C to +125°C
Humidity (non condensing) 95 % rel H max.
Reliability, calculated MTBF (MIL-HDBK-217F, at +25°C, ground benign) >2’000’000 h
Isolation voltage (60 sec.)
Input/Output 1‘000 VDC
Isolation capacitance
Input/Output 60 pF typ.
Isolation resistance
Input/Output >1‘000 Mohm
Switching frequency 100 kHz typ. (frequency modulation)
Frequency change over line and load –50 / +20 kHz max.
Altitude during operation up to 5‘000 m (16‘400 ft) approved
Safety standards IEC 60950-1:2005 (2nd edition) + Am 1:2009
EN 60950-1:2006 + Am 1:2010 + Am 11:2009
Safety approvals
– CB scheme (IEC 60950-1)
www.tracopower.com/products/tra-cb.pdf
– CSA certification (UL 60950-1, CSA 60950-1-07)www.tracopower.com/products/tra-csa.pdf
All specifications valid at nominal input voltage, full load and +25°C after warm-up time unless otherwise stated.
http://www.tracopower.com
Page 2 of 3
DC/DC Converters
TRA 1 Series
1 Watt
Physical Specifications
Casing material non conductive plastic (UL 94V-0 rated)
Weight
– 5 & 12 VDC models 2.2 g (0.07 oz)
– 24 VDC models 2.6 g (0.09 oz)
Soldering temperature max. 260°C, 10 sec, 1.5 mm from case
Environmental compliance
– Reach www.tracopower.com/products/tra1-reach.pdf
– RoHS RoHS directive 2002/95/EC
Graph 1: Load regulation
+20%
+20%
+15%
+15%
Output Voltage(%)
+10%
+10%
Max.
+5%
+5%
T yp.
Vnom
Vnom
Min .
-5%
-5%
-10%
-10%
0%
20%
40%
60%
80%
100%
Output Load Current (%)
Application note: www.tracopower.com/products/tra1-application.pdf
Outline Dimensions
10.2 (0.4)
3.2 (0.13)
0.5 (0.02)
Pin-Out
0.5
(0.02)
2.3
±0.4
(0.09
±0.02)
2.54
5.08
(0.1)
(0.2)
2.54 2.54
(0.1)
0.5 (0.02)
(0.1)
Pin
Single
Dual
1
+Vin (Vcc)
+Vin (Vcc)
2
–Vin (GND)
–Vin (GND)
4
–Vout
–Vout
5
No pin
Common
6
+Vout
+Vout
0.5 (0.02)
6
7.1 (0.28)
5
24 V Models
4
6.1 (0.24)
2
Dimensions in [mm], () = Inch
Pin pitch tolerances: ±0.13 (±0.005)
Case tolerances: ±0.25 (±0.01)
(0.05)
1
1.3
Bottom view
0.25 (0.01)
19.5 (0.77)
Specifications can be changed any time without notice.
Rev. 07/12
Jenatschstrasse 1 · CH-8002 Zurich · Switzerland
Tel. +41 43 311 45 11 · Fax +41 43 311 45 45 · [email protected] · www.tracopower.com