Full Datasheet (english)

AC/DC Power Supplies
TOP 100 Series, 100 Watt
CB
Scheme
Features
◆ 100 W power supply in 2.0”x 4.0“ footprint!
◆ Full load operation up to +50°C with
CSA C22.2
UL 60950-1
convection cooling
◆ Highest efficiency, 90 % typ.
◆ EMI filter meets EN 55022, level B
◆ Compliance with EN 61000-3-2
◆ Low leakage current
◆ Safety class l and class ll operation
◆ 3-year product warranty
The new TOP-100 Series AC/DC Power Supplies feature the highest power rating
in the industry standard 2.0” x 4.0” (50.8 x 101.6 mm) footprint. They can supply
up to 100 W output power with convection cooling over an industrial operating
temperature range of –25°C to +50°C. This performance could be realized by a state
of the art design providing an extremely high efficiency of >90 % which eliminates
the need for a dedicated power supply cooling fan.
Also see: www.tracopower.com/products/top100_article_e1.pdf
Compliance with global safety and EMC standards qualify these power supplies for
worldwide markets. Approved for Class l and Class ll applications, these switchers
are suitable for industrial and IT systems but also for consumer products. High reliability is provided by use of industrial quality grade components and an excellent
thermal management. This product offers an interesting power supply solution for
many space and cost critical applications in commercial and industrial electronic
equipment.
Models
Order Code
Output Voltage
(Adjustment Range)
Output Current
max.
TOP 100-105
5.0 VDC
(5.0 - 5.2)
20.0 A
TOP 100-112
12 VDC
(12.0 - 13.0)
8.3 A
TOP 100-115
15 VDC
(15.0 - 16.0)
6.7 A
TOP 100-124
24 VDC
(24.0 - 26.0)
4.2 A
TOP 100-148
48 VDC
(48.0 - 52.0)
2.1 A
On demand (not for new design in) : TOP 100-103 with Output 3.3 VDC (3.3–3.5) / 20.0 A
http://www.tracopower.com
Page 1 of 4
AC/DC Power Supplies
TOP-100 Series
100 Watt
Input Specifications
Input voltage range 90 – 132 / 187 – 264 VAC autorange
power derating at low input voltage: 50 % at 90 VAC – 0 % at 103 VAC
20 % at 187 VAC – 0 % at 207 VAC
Input frequency 47 – 63 Hz
Input protection T4 A/250 V internal fuse in both line & neutral
Harmonic limits EN 61000-3-2, class A
Zero load power consumption 3.6 W
Recommended circuit breaker 6 A (characteristic C) or slow blow fuse
Output Specifications
Regulation
– Input and Load variation 1.0 % max.
Output voltage adjustment with internal potentiometer
(for range see model table)
Ripple and noise (20Mhz Bandwidth) <100 mVp-p
48 VDC model: <200 mVp-p
Overvoltage protection 3.3
5.0
12
15
24
48
VDC
VDC
VDC
VDC
VDC
VDC
model:
model:
model:
model:
model:
model:
5.0 V
6.0 V
16 V
20 V
30 V
60 V
Power back immunity
3.3
5
12
15
24
48
VDC
VDC
VDC
VDC
VDC
VDC
model:
model:
model:
model:
model:
model:
5.0 V (6.0 V for 1 sec)
6.3 V (7.0 V for 1 sec)
16 V (18 V for 1 sec)
20 V (23 V for 1 sec)
35 V (40 V for 1 sec)
63 V (68 V for 1 sec)
Overload protection by current limit at 150 % Iout max.
Short circuit protection foldback (automatic recovery)
Capacitive load 10’000 µF max.
General Specifications
Operating temperature –25°C to +70°C with derating
Power derating depending on temperature
Convection Cooling
Forced Air Cooling 5 CFM (300 LFM)
80
80
tnput Power [W]
100
Output Power [W]
100
60
40
20
0
-25
0
20
40
60
80
60
40
20
0
-25
Ambient Temperature [°C]
For horizontal mounting
http://www.tracopower.com
0
20
40
60
80
Ambient Temperature [°C]
3.3 VDC model
5 VDC model
other models
Page 2 of 4
AC/DC Power Supplies
TOP-100 Series
100 Watt
General Specifications
Temperature coefficient 0.02 %/K
Humidity (non condensing) 0 – 95 % rel. H max.
Efficiency
– Vin = 115 VAC 89 – 91 %
– Vin = 230 VAC 90 – 92 %
Switching frequency 100 kHz typ. (pulse width modulation)
Hold-up time – Vin = 115 VAC 10 ms typ.
– Vin = 230 VAC 15 ms typ.
Start-up time – Vin = 115 VAC <3.5s
– Vin = 230 VAC<2s
Isolation voltage– Input / Output 3000 VAC
– Input / Field Ground 1500 VAC
– Output / Field Ground 500 VAC
Isolation resistance (at 500 VDC) 100 Mohm min.
Earth leakage current 250 µA max.
Reliability, calculated MTBF at +25°C acc. to IEC 61709 www.tracopower.com/products/top100-mtbf.pdf
Isolation class class II double isolation
EMC emissions
– Conducted input RI suppression EN 55022, class B (conductive plane to be
connected to safety earth)
– Harmonic current emissions IEC / EN 61000-3-2, class A
EMC immunity
–
–
–
–
–
–
Electrostatic discharge ESD RF field immunity Electrical fast transients/burst immunity Surge
Conducted RF Voltage dip IEC / EN 61000-4-2
IEC / EN 61000-4-3
IEC / EN 61000-4-4
IEC / EN 61000-4-5
IEC / EN 61000-4-6
IEC / EN 61000-4-11
Safety approvals and
certifications
– CB certificate (IEC 60950-1) www.tracopower.com/products/top100-cb.pdf
– SIQ certificate (EN 60950-1) www.tracopower.com/products/top100-siq.pdf
– UL coc (UL 60950-1) www.tracopower.com/products/top100-ul.pdf
www.tracopower.com/products/top100-csa.pdf
– CSA certificate (CSA C22.2 No. 60950-1-03)
Environment – Vibration acc. IEC 60068-2-6; 3 axis, sine sweep, 10–55Hz, 1g, 1oct/min
– Shock acc. IEC 60068-2-27 3 axis, 10g half sine, 11msShock
20 G (3 directions each 3 times)
Environmental compliance
– Reach www.tracopower.com/products/top100-reach.pdf
– RoHS RoHS directive 2011/65/EU
Connection pin connector (Molex)
Weight
Installation instructions :
140 g (4.9 oz)
www.tracopower.com/products/top100-inst.pdf
All specifications valid at nominal input voltage, full load and +25°C after warm-up time unless otherwise stated.
http://www.tracopower.com
Page 3 of 4
AC/DC Power Supplies
TOP-100 Series
100 Watt
Dimensions
4.0 (101.6)
2.0 (50.8)
OUT
Field Ground
4x ø 0.157 (4.0)
1.25 (31.8)
J2 1
1.75 (44.5)
1
J1
AC IN
0.14 (3.6)
3.75 (95.3)
6
Dimensions in Inch, () = mm
4x Pillars (not included) for connection to safety earth:
Height: 0.2 min. (5.0), Diam.: 0.25 max. (6.0)
To comply with EN 55022 class B:
Field ground (FG) is to be connected to chassis
Input
Output
Pin
J1
Pin
J2
1
AC in
1
– Vout
2
AC in
2
– Vout
3
– Vout
4
+ Vout
5
+ Vout
6
+ Vout
J1: Molex Series 41791
mates with Molex crimp terminal: 08-52-0072
and terminal housing: 09-50-3031
J2: Molex Series 41791
mates with Molex crimp terminal: 08-52-0072
and terminal housing: 09-50-3061
Specifications can be changed without notice! Make sure you are using the latest documentation, downloadable at www.tracopower.com
Rev. April 29. 2014
www.tracopower.com
Page 4 of 4