X3PM,X3HM Data sheet Pre-amplified/3V Excitation/Gauge Features . . . . . Applications . Industrial instrumentation . Pressure switch, Pneumatic device . Medical device 3V excitation, Battery operation available Volt level output On-chip amplification and temperature compensations Pre-calibration of offset voltage and span Non-corrosive liquid measurable (X3PMC, X3HMC only) Part number for ordering X3PM C - 050KP G R Terminal leads direction(See Outline Diagram) No mark : Rated pressure (Pa) Model X3PM X3HM Available pressure media No mark : Non-corrosive gas only C : Non-corrosive gas and liquid (Contact us about availability) Pressure type R : Pressure type G : Gauge (Positive pressure) GV : Gauge (Negative pressure) GW : Gauge (Bipolar pressure) Gauge pressure X3PM X3HM Dual-In-line-Package (DIP) Horizontal pressure port DIP Model Package configuration Measurable pressure range (kPa) 100 100 0 100 0 50 0 100 0 200 0 1000 X3PM-100KPGW X3PM-100KPGV X3PM-050KPG X3PM-100KPG X3PM-200KPG X3PM-001MPG Part number for ordering X3PM-100KPGWR X3PM-100KPGVR X3PM-050KPGR X3PM-100KPGR X3PM-200KPGR X3PM-001MPGR X3HM-100KPGWR X3HM-100KPGVR X3HM-050KPGR X3HM-100KPGR X3HM-200KPGR X3HM-001MPGR Specifications Model/Rated pressure 100KPGW 100KPGV 050KPG 100KPG 200KPG 001MPG Recommended operating conditions Pressure type Gauge pressure 100 100 50 100 200 1000 Rated pressure 1.020 1.020 0.510 1.020 2.040 10.20 Measurable pressure range 100 100 0 100 0 50 0 100 0 200 0 1000 Pressure media 1 XFPM, XFHM : Non-corrosive gas only, XFPMC, XFHMC : Non-corrosive gas and liquid Excitation voltage 3.0 0.15 Absolute maximum rating 1.5times of rated pressure Maximum load pressure Twice of rated pressure Maximum excitation voltage 6 Operating temperature 10 80 Storage temperature 20 100 Operating humidity 30 80 (No dew condensation) Electric performances/characteristics (Excitation voltage Vcc=3.0V constant, Ambient temperature Ta=25 ) Current consumption less than 6 Output impedance less than 10 Source current less than 0.1 Sink current less than 1.0 Mechanical response time 2 (For the reference) Full scale span voltage 1.5 Offset voltage 1.2 0.5 0.075 Full scale span voltage 1.2 2.0 0.075 Accuracy 1.2 5.0 Note ; 1) Please consult us available when you choose the C models. 2) Excluding input voltage error. 1 Unit kPa kg/cm2 kPa VDC VDC RH mA mA mA msec V V V FS/0 50 X3PM,X3HM Data sheet Pre-amplified/3V Excitation/Gauge Outline dimensions unit (mm) X3PM 4 5 6 3 2 1 C0.5 3 2 4 3 14 1 4.5 0.6 Vent hole R1.5 15.24(600mil) 5 Pressure port 0.8 max 15 2.2 0.5 6 8 5 0.2 4 12 Terminal leads Labelled faceplate 6.8 2.8 Recommended footprint for PCB 6- 1.8(Diameter of lands) 2.54 2.54 0.5 60 1.2 2.54 2.54 6- 0.9(Diameter of through holes) 15.2 unit (mm) unit (mm) X3PM-R 4 0.2 8 0.8 Pressure port 2.2 0.5 3 14 R1.5 4 5 6 3 2 4.5 1 15.24(600mil) 5 max 15 6 4 5 12 C0.5 1 2 0.6 Vent hole 3 Terminal leads Recommended footprint for PCB 2.54 2.54 6- 0.9(Diameter of through holes) 6- 1.8(Diameter of lands) 2.54 2.54 60 1.2 0.5 Labelled faceplate 2.8 6.8 15.2 2 unit (mm) X3PM,X3HM Data sheet Pre-amplified/3V Excitation/Gauge Outline dimensions unit (mm) 2.54 2.54 X3HM-R 2 3 6 5 4 5.5 1 Pressure port (14) 1.2 4.7 2.6 3.4 (7.6) 1.55 3.2 1 6 0.6 0.25 Recommended footprint for PCB 8 Labelled faceplate 6 5 4 6- 1(Diameter of through holes) 2.54 2.54 8 6- 1.8(Diameter of lands) 1 15 Vent hole 10.16 1 2 3 10 3 unit (mm) X3PM,X3HM Data sheet Pre-amplified/3V Excitation/Gauge Connection diagram X3PM, X3HM Vcc(DC5V) Vcc Vout Vout GND C2 C1 Remarks : 1) C1 : Connect 680pF capacitor within 2cm distance from leads. GND 2) C2 : Connect 0.01 F or more capacitor within 2cm distance from leads. 3) 4 and 5 pins must be No Connection. Open them as floating ones completely, and do NOT connect to other line or each other. Transfer Function Vout=Vs (P + ) (Pressure Error Temperature Error Multiplier Vs) Vs=3.0volts Notes ; The output voltage (Vout) is no perfect ratiometric with the power supply voltage. P=Input Pressure(kPa) Model 050KPG(D) 100KPG(D) 100KPGV(DV) 100KPGW(DW) 200KPG(D) 001MPG(D) 115KPA pressure range 0 50kPa 0 100kPa 0 100kPa 100 +100kPa 0 200kPa 0 1MPa 15 115kPa.abs 0.01 0.005 0.005 0.0025 0.0025 0.0005 0.005 Temperature Error Multiplier=1 Note ; Please read instruction “Notes” before using the sensor. Fujikura reserves the right to change specifications without notice. If you have any questions regarding technical issues or specifications, please contact us. Sensor Engineering Department 5-1 Kiba 1-chome, Koto-ku, Tokyo 135-8512, Japan Phone +81-(0)3-5606-1072 Fax. +81-(0)3-5606-1538 4 E-mail : [email protected] 0.1667 0.1667 0.1667 0.4167 0.1667 0.1667 0.09167 Pressure Error(kPa) 2.5 5.0 5.0 10.0 10.0 50.0 5.0