TELEDYNE S114DD-6

TELEDYNE RELAYS
CENTIGRID®
SURFACE MOUNT
AEROSPACE RELAY
SERIES
S114
DPDT
SERIES
DESIGNATION
RELAY TYPE
S114
DPDT basic relay
S114D
DPDT relay with internal diode for coil suppression
S114DD
DPDT relay with internal diodes for coil transient suppression and polarity
reversal protection
INTERNAL CONSTRUCTION
DESCRIPTION
The S114 Series Surface Mount Centigrid® Relay is an ultraminiature, hermetically sealed,
armature relay. The low profile height (.360”) and .100” lead spacing make it ideal for
applications where extreme packaging density and/or close PC board spacing are required.
The specially formed leads are pre-tinned to make the relays ideal for most types of surface
mount solder reflow processes.
UNIFRAME
ARMATURE
UPPER
STATIONARY
CONTACT
The basic design and internal construction are identical to the 114 Series Centigrid® relays,
and are capable of meeting Teledyne Relays T 2R® requirements. The following unique
construction features and manufacturing techniques provide overall high reliability and
excellent resistance to environmental extremes:
MOVING
CONTACT
LOWER
STATIONARY
CONTACT
•
•
•
•
•
ENVIRONMENTAL AND
PHYSICAL SPECIFICATIONS
Temperature
(Ambient)
-65°C to +125°C
Vibration
30 g’s to 3000 Hz (Note 3)
Shock
75 g’s for 6 msec. (Note 3)
half-sine
Acceleration
50 g’s (Note 3)
Enclosure
All welded, hermetically sealed
Weight
0.07 oz (1.9 gms.) max.
Reflow
Temperature
260°C max. temp.
5 min. max. above 180°C
All welded construction.
Unique uni-frame design providing high magnetic efficiency and mechanical rigidity.
High force/mass ratios for resistance to shock and vibration.
Advanced cleaning techniques provide maximum assurance of internal cleanliness.
Precious metal alloy contact material with gold plating assures excellent high current
and dry circuit switching capabilities.
The S114D and S114DD Series utilize internal discrete silicon diodes for coil suppression
and polarity reversal protection.
By virtue of its inherently low intercontact capacitance and contact circuit losses, the S114
relay has shown itself to be an excellent ultraminiature RF switch for frequency ranges well
into the UHF spectrum. A typical RF application for the S114 relay is in hand held radio
transceivers, wherein the combined features of good RF performance, small size, low coil
power dissipation and high reliability make it a preferred method of transmit-receive
switching (see Figure 1).
56
SERIES S114
GENERAL ELECTRICAL SPECIFICATIONS
Contact Arrangement
Rated Duty
Contact Resistance (Note 4)
Contact Load Rating (DC)
(See Fig. 3 for other DC
resistive voltage/current ratings)
2 Form C (DPDT)
Continuous
0.1 ohm max. before life; 0.2 ohm max. after life at 1A/28VDC, (measured 1/8” from header along lead)
Resistive:
1 Amp/28VDC
Inductive:
200 mA/28VDC (320 mH)
Lamp:
100 mA/28VDC
Low Level: 10 to 50 µA/10 to 50 mVDC
Resistive:
250 mA/115VAC, 60 and 400Hz (Case underground)
100 mA/115VAC, 60 and 400Hz (Case grounded)
10,000,000 cycles (typical) at low level
01,000,000 cycles (typical) at 0.5A/28VDC resistive
00,100,000 cycles min. at all other loads specified above
2A/28VDC Resistive (100 cycles min.)
Contact factory
450 milliwatts typical at nominal rated voltage @ 25°C
2.0 msec max. at nominal rated coil voltage @ 25°C
S114 Series: 1.5 msec max.
S114D, S114DD Series: 4.0 msec max.
1.5 msec max.
0.4 pf typical
10,000 megohms min. between mutually isolated terminals
Atmospheric pressure: 500 VRMS/60 Hz
70,000 ft.: 125 VRMS/60Hz
100 VDC min.
1.0 VDC max.
Contact Load Ratings (AC)
Contact Life Ratings
Contact Overload Rating
Contact Carry Rating
Coil Operating Power
Operate Time
Release Time
Contact Bounce
lntercontact Capacitance
Insulation Resistance
Dielectric Strength
Diode P.I.V. S114D, S114DD
Negative Coil Transient S114D, S114DD
DETAILED ELECTRICAL SPECIFICATIONS
(-65°C to +125°C unless otherwise noted) (Note 2)
➧
BASE PART
NUMBERS
Coil Voltage (VDC)
(-65°C to +125°C unless otherwise noted) (Notes 1 & 2)
Nom.
Max.
S114, S114D
S114DD (Note 4)
Min.
(Note 4)
Max.
S114, S114D
S114DD
S114
Min.
S114D
Max.
S114DD
Min.
Max.
Coil Resistance
(Ohms ± 10% @ 25°C)
Coil Current (mADC @ 25°C)
(S114DD Series only)
Pick-up Voltage (VDC, Max.)
Dropout Voltage (VDC)
S114-5
S114D-5
S114DD-5
S114-6
S114D-6
S114DD-6
S114-9
S114D-9
S114DD-9
S114-12
S114D-12
S114DD-12
S114-18
S114D-18
S114DD-18
S114-26
S114D-26
S114DD-26
5.0
5.8
50
39
93.2
128.2
3.5
4.0
0.14
2.3
0.6
2.8
6.0
8.0
98
78
57.8
74.8
4.5
5.0
0.18
3.2
0.7
3.4
9.0
12.0
220
220
33.0
42.9
6.8
7.8
0.35
4.9
0.8
5.3
12.0
16.0
390
390
25.6
32.8
9.0
10.0
0.41
6.5
0.9
6.5
18.0
24.0
880
880
17.5
22.1
13.5
14.5
0.59
10.0
1.1
10.0
26.5
32.0
1560
1560
14.8
18.5
18.0
19.0
0.89
13.0
1.4
13.0
PERFORMANCE CURVES
(NOTE 1)
TYPICAL RF PERFORMANCE (NOTE 10)
0
TYPICAL DC CONTACT RATING (RESISTIVE)
INSE
RTIO
N
.1
LOSS
300
.2
LOAD VOLTAGE (VDC)
.3
10
1.92
R)
S (VSW
20
LOS
ETURN
1.22
R
30
40
ROSS
N AC
50
ATIO
ISOL
60
1.07
ACTS
CONT
TION
ISOLA
1.02
LES
1.01
S PO
CROS
A
VSWR
dB
.4
200
150
100
50
1.00
70
250
1.00
.01
0.5
.1
.5
1.0
0
0.1
0.2
0.3
0.4
0.5
0.6
FREQUENCY (GHz)
LOAD CURRENT (AMPS DC)
FIGURE 1
FIGURE 2
57
0.7
0.8
0.9
1.0
SERIES S114
TERMINAL LOCATIONS AND
SCHEMATIC DIAGRAMS
OUTLINE DIMENSIONS AND RECOMMENDED PAD LAYOUT (Notes 6, 7, 8 & 9)
.335 MAX
(8.51)
7
.275 MAX
(6.99)
.360 MAX
(9.14)
8
1
2
6
S114
+.030
.378 –.020 TYP
Ø.017 REF
(.43)
+.76 )
(9.60 –.51
2° ± 2° TYP
5
4
3
7
8 (–) 1
.031 REF (.79)
.035 REF
(.89)
.100 4 PL
(2.54)
4° MAX TYP
4° MAX TYP
2
6
.045 MIN 8 PL
(1.14)
S114D
.200
(5.08)
.100 TYP (2.54)
.410 MIN
(10.41)
.375 SQ MAX
(9.53)
.200
(5.08)
.200
(5.08)
5
4 (+) 3
7
8 (–) 1
2
6
S114DD
TELEDYNE PART NUMBERING SYSTEM FOR SURFACE MOUNT RELAYS
S
1
1
4
D
-2
5
6
4 (+) 3
SCHEMATICS ARE VIEWED FROM TERMINALS
SURFACE
MOUNT
SERIES NO.
DD = SUPPRESSION DIODE
DD = SUPPRESSION AND POLARITY PROTECTION DIODES
COIL VOLTAGE
NOTES:
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
Characteristics shown as “typical” are based on available data and are best estimates. No on-going verification tests are performed.
Unless otherwise specified, parameters are initial values.
Relays will exhibit no chatter in excess of 10 µsec or transfer in excess of 1 µsec.
For reference only. Coil resistance not directly measurable at relays terminals due to internal series semiconductor.
Measured at nominal voltage for 5 sec. max.
Position of leads as they emerge from relay base.
Leads will fit noted pad layout with no overhang.
Lead ends are coplanar within .008” wide tolerance zone.
Terminals coated with SN60 or SN63 solder per QQ-S-571. Kovar exposed at sheared end of leads.
RF performance curves based on 114 series relays.
©1996
TELEDYNE RELAYS
58
12525 Daphne Avenue
Hawthorne, California 90250