QB00FM - Teledyne Relays

Series QB00FM
Optically Isolated Bi-Directional & DC Output
Bi-Directional Solid-State Relay
Part Number* Relay Description
QB00FM
±7.5A @ ±150Vdc Output ,Solid State Relay
* The Y suffix denotes parameters tested to MIL-PRF-28750 specifications.
The W suffix denotes parameters tested to Teledyne specifications.
ELECTRICAL SPECIFICATIONS
(-55°C TO +105°C Ambient Temperature Unless Otherwise Specified)
INPUT (CONTROL) SPECIFICATION
(See Fig. 1 and Note 1)
Min
Max Units
Input Current @ VIN = 6 Vdc
38
mAdc
Turn-Off Voltage (Guaranteed Off)
1.5
Vdc
Turn-On Voltage (Guaranteed On)
4.5
Reverse Voltage Polarity
Input Supply Range (See Fig. 2 and Note 1)
4.5
Vdc
Min
Load Current (See Fig. 3) (No Heat Sink)
• Capable of DC or bi-directional DC
switching (AC)
• Parameters tested utilizing MIL-PRF28750 test methods
Max Units
Adc
±10 µAdc
±100 µAdc
Continuous Operating Output Voltage
±150
Vdc
Transient Blocking Voltage (See Note 3)
±180
Vdc
ON Resistance Rds (on) at TJ = 25°C
ILOAD = 100 mAdc (See Fig. 4 and Note 4)
0.10 Ohm
Turn-On Time (See Fig.5)
7.5
ms
Turn-Off Time (See Fig. 5)
2.0
ms
QB00FM 94
• Fast switching speed
Vdc
Vdc
100
Output Capacitance at 25 Vdc, 100 KHz
• Optical isolation
16
0.7
dV/dt @ +25°C
• Power FET output
• High surge current capability
Leakage Current
Output Voltage Drop @ 4.3A
• Low ON resistance
Vdc
±4.3
@ VLOAD = ±150 Vdc (25°C)
@ VLOAD = ±150 Vdc (105°C)
• High voltage output
-16
OUTPUT (LOAD) SPECIFICATIONS
Bi-directional Configuration (See Fig. 1)
FEATURES
V/µs
1600
pF
APPLICATIONS
• Ideal for Automatic Test Equipment
(ATE)
• High voltage systems
• High-speed switching with low EMI
• Squib Fire
DESCRIPTION
The QB00FM relay is an advanced solidstate bi-directional relay designed for
high-speed power switching applications.
This relay utilizes state-of-the-art
solid-state circuit technology and
manufacturing techniques to provide high
reliability, low life cycle cost and
exceptional switch performance. The
QB00FM is capable of switching AC or
DC power. The three output terminals
can be configured for DC switching with
ON resistance reduced to 25 milliohms
and a current rating of 7.5A continuous.
Other features include optical coupling to
minimize EMI generation and to protect
logic circuits from output voltage
transients. The QB00FM is packaged in
a hermetically sealed low profile package
suitable for heat sink or circuit card
mounting. Pin 6 is connected to the case
for additional safety shielding.
SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE
© 2002 TELEDYNE RELAYS
QB00FB\072002\Q1
Series QB00FM
OUTPUT (LOAD) SPECIFICATIONS
DC Configuration (See Fig. 1 and Notes 2 & 6)
Min
MECHANICAL SPECIFICATIONS
Max Units
Load Current (See Fig. 3) (No Heat Sink)
7.5
Adc
Leakage Current @ VLOAD = ±150 Vdc (25°C)
20
µAdc
Leakage Current @ VLOAD = ±150 Vdc (105°C)
200
µAdc
Output Voltage Drop @ 7.5A
0.45
Vdc
Continuous Operating Load Voltage
150
Vdc
Transient Blocking Voltage (See Note 3)
180
Vdc
ON Resistance Rds (on) at TJ = 25°C
0.035 Ohm
ILOAD = 100 mAdc (See Fig. 4 and Note 4)
Turn-On Time (See Fig.5)
8.5
ms
Turn-Off Time (See Fig. 5)
2.0
ms
3200
pF
Output Capacitance at 25 Vdc, 100 KHz
• Weight:
• Case:
• Pins:
Tolerances:
OUTPUT (LOAD) SPECIFICATIONS
All Configurations
Min
Input to Output Capacitance
.XX
.XXX
ANGLE
Max Units
10
25g (max)
6 pin, hermetically sealed
Plated, gold
± 0.015
± 0.010
±1/2°
pF
Dielectric Strength
500
Vac
Insulation Resistance @ 500 Vdc
109
Ohm
Junction Temperature
@ ILOAD = Imax rated
125
°C
Thermal Resistance Junction to Ambient, (θJA)
30
°C/W
Thermal Resistance Junction to Case, (θJC)
2.0
°C/W
DIMENSIONS ARE SHOWN IN INCHES
(MILLIMETERS)
BLOCK DIAGRAM
ENVIRONMENTAL SPECIFICATIONS
All Configurations
Min
Max Units
Temperature Range
Operating
Storage
-55
-55
+105
+125
°C
°C
Vibration (10–2,000 Hz)
100
g
Constant Acceleration
5000
g
Shock (0.5 ms)
1500
g
© 2002 TELEDYNE RELAYS
(800) 284-7007 • www.teledynerelays.com
QB00FM 95
QB00FM\072002\Q1
Series QB00FM
A) BI-DIRECTIONAL AND DC CONFIGURATION
(SEE NOTE 1 & 3)
LOAD CURRENT DERATING CURVE
(NO HEAT SINK)
FIGURE 3
B) DC CONFIGURATION (SEE NOTE 1 & 3)
WIRING CONFIGURATIONS
FIGURE 1
NORMALIZED ON RESISTANCE VS JUNCTION
TEMPERATURE
FIGURE 4 (SEE NOTE 4)
TYPICAL INPUT CURRENT VS INPUT VOLTAGE
FIGURE 2
TURN ON AND TURN OFF TIMING DIAGRAM
FIGURE 5
QB00FM 96
SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE
© 2002 TELEDYNE RELAYS
QB00FB\072002\Q1
Series QB00FM
SERIES RESISTANCE VS INPUT VOLTAGE
FIGURE 6 (SEE NOTE 1)
NOTES:
1.
2.
3.
4.
5.
6.
For input voltages above 6V, a series resistor is required. Use the standard resistor value
equal to or less than the value found in Figure 6. (VINPUT - 6V) / 0.035 A
The input voltage should never exceed 16 Vdc.
The rated input voltage is 5V for all tests unless otherwise specified.
Relays may drive loads connected to either positive or negative reference power supply
lines. Inductive loads must be diode suppressed.
To calculate the maximum ON resistance for a given junction temperature, find the
normalized ON resistance factor (NR) from Figure 4. Calculate the new ON resistance as
follows:
R(ON) = NR X R(ON) @ 25°C
Input transition should be ≤ 1 ms duration and input drive should be “bounceless contact”
type.
Relays are tested in the bi-directional configuration only. DC parameters are shown for
reference only.
© 2002 TELEDYNE RELAYS
(800) 284-7007 • www.teledynerelays.com
QB00FM 97
QB00FM\072002\Q1