AC SOLID STATE RELAY Series 602 OPTICALLY ISOLATED 10 A, 250 VAC Part Number* MilitaryRelay Description 602-1W AC Solid State Relay 602-1Y 86031-001 * The Y suffix denotes parameters tested to MIL-R-28750 test methods. The W suffix denotes parameters tested to Teledyne specifications. FEATURES • ELECTRICAL SPECIFICATIONS (-55°C TO +95°C UNLESS OTHERWISE SPECIFIED) INPUT (CONTROL) CHARACTERISTICS Min Typ Max Units Input Current VIN = 5 Vdc 13 15 (See Figure 1) VIN=32 Vdc 13 16 Turn-Off Voltage (Guaranteed Off) 1.0 mA dc • • • • • • Available to DESC drawing 86031001 Optical isolation Low minimum output current Extremely low EMI Zero voltage turn-on Zero current turn-off Logic compatible input Available to Y screening levels of MIL-R-28750 Vdc DESCRIPTION Turn-On Voltage (Guaranteed On) 3.8 Vdc Reverse Voltage Protection Input Voltage Range 3.8 -32 Vdc 32 Vdc OUTPUT (LOAD) SPECIFICATIONS Min Output Current Rating (See Figure 3) Typ Max Units 10 Amps Output voltage Rating 25 250 Vac Frequency Range 45 440 Hz 1.5 Vrms Off-State Leakage Current (250 Vac, 400 Hz) 8.0 mA Turn-On Time ½ Cycle Turn-Off Time 1 Cycle Output Voltage Drop @ 10 Ampere, 25oC (See Figure 2) Transient Voltage +460 V pk Overload Current (See Note 3) 35 The 602-1 is an AC output solid state relay designed for power switching. The relay incorporates a hermetically sealed, optically coupled solid state relay as a driver. This driver provides zero voltage turn-on as well as a logic compatible control circuit. The relay output is rated for 10A at 250Vac and switches the load with a hermetically sealed triac. A built-in snubber circuit provides reliable switching of both resistive and reactive loads with power factors as low as 0.2. The internal components are potted with a thermally conductive epoxy, which provides an environmental seal for severe environmental conditions encountered in military and aerospace applications. The 602-1 is available in W and Y screening levels. The 602-1Y is available to DESC drawing 86031-001 WIRING DIAGRAM + Amps + 1 Zero Voltage Turn-On Point Off-State dv/dt (See Note 1) +15 200 V pk 3 LOAD CONTROL SOURCE V/us 2 4 ~ AC LINE - Load Power Factor 0.2 Insulation Resistance @ 500 Vdc 109 Input to Output Capacitance 6/99 - Ohms 15 pF © 1999 TELEDYNE RELAYS Series 602 OUTPUT (LOAD) SPECIFICATIONS Min Dielectric Withstanding Voltage Typ Max Units 1500 18 Vac 15 o Junction Temperature (TJ Max) 150 Thermal Resistance Junction to Ambient (0JA) 15.5 o Thermal Resistance Junction to Case (0JC) 2.5 o 602-1 (DC) 12 C 9 C/W 6 C/W 3 0 0 ENVIRONMENTAL SPECIFICATIONS* Acceleration MECHANICAL SPECIFICATIONS 2.00 }.02 .875 }.015 1 1.00 }.015 3 .50 .30 .60 }.015 TERMINAL SCREW #6 BINDING HD MACHINE SCREW 4 PLACES MOUNTING HOLE FOR #6 SCREW 2 4 .44 }.015 1.00 INCHES MM .015 .02 .05 .06 .11 .16 .30 .44 .50 .60 .75 .875 1.00 1.10 2.00 0.38 0.51 1.27 1.5 2.8 4.1 7.6 11.2 12.7 15.2 19.05 22.23 25.4 27.9 50.8 40 45 VDC 2.0 1.6 1.2 .8 .4 0 0 5 10 LOAD CURRENT VS. TYPICAL OUTPUT VOLTAGE DROP FIGURE 2 10 8 6 HEA T SI NK NK NO 4 2 0 20 30 40 50 60 70 80 90 100 110 AMBIENT TEMPERATURE (°C) THERMAL DERATING CURVES FIGURE 3 NOTES: 1. 2. 3. 4. 5. 6. 7. AMPS SI ANTIROTATION BOSS ALUMINUM HEAT SINK 35 AT .11 .75 30 HE .06 TEMPERATURE MEASUREMENT POINT 25 W .05 .02 20 C/ 1.10 MAX. 15 1° .16 10 FIGURE 1 OUTPUT VOLTAGE DROP (VOLTS) Shock Vibration 5 TYPICAL INPUT CURRENT VS. INPUT VOLTAGE LOAD CURRENT (AMPS) -55o C to +95o C Operating -55o C to +110o C Storage 100 g for 6 ms 30 g, 78 to 2000 Hz (0.1 Double Amplitude 10 to 78 Hz) 100 g Ambient Temperature DIMENSIONS ARE IN INCHES. METRIC EQUIVALENTS ARE GIVEN FOR GENERAL INFORMATION ONLY. UNLESS OTHERWISE SPECIFIED, TOLERANCES: .XXX = }.005 (0.13MM); .XX = }.01 (0.25MM). CIRCUIT DIAGRAM SHOWN ON PART IS TERMINAL VIEW. WEIGHT: 6 OZ. MAX. CASE MATERIAL: ALUMINUM NICKLE PLATED. BUILT IN SNUBBER (R = 100 Ω C = 0.01ΜF). 8. OUTPUT MAY LOSE BLOCKING CAPABILITIES DURING AND AFTER SURGE UNTIL TJ FALLS BELOOW MAXIMUM. SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT CHANGE WITHOUT NOTICE