NEW! Series C62 DC Solid State Relay NORMALLY ON, OPTICALLY ISOLATED 0.2 A, 200 VDC Part Number Relay Description C62-20 0.2A, 200 Vdc, DC Solid State Relay, Normally on 6 Pin DIP Plastic (for surface mount add “s” prefix) ELECTRICAL SPECIFICATION ( -20°C TO +85°C, Ambient Temperature UNLESS OTHERWISE SPECIFIED) INPUT (CONTROL) SPECIFICATION Min Input Current Typ 8 Max Units 50 Turn-On FEATURES mA dc 0.1 mA dc Turn-Off 8.0 • • • • • • mA dc OUTPUT (LOAD) SPECIFICATION Min Typ Max Units Current Rating (Continuous) 0.20 Adc Operating Voltage (Continuous) 200 Vdc 0.80 Vdc o Output Voltage Drop @ 25 C Low on resistance Normally on without Input Optical Isolation Paralleling capability Small Package SMT APPLICATIONS • Protection circuits • Normally on switch @ Rated Load Current (Input Current = 0 mA) DESCRIPTION ON Resistance @ TJ = 25 oC 4.0 ohm @ TJ = 85 oC 6.7 ohm 25 µA Leakage Current @ V = 200 Vdc (See Note 2) Turn-On Time 4.50 mSec Turn-Off Time 400 µSec Insulation Resistance @ 500 Vdc 100 3 pF Output Capacitance @ 25 Vdc, © 2000 TELEDYNE RELAYS Opto isolated control feature, high reliability, small size and low weight makes this normally on solid state switch a good replacement for the electromechanical switch. Meg Ohm Isolation (Input to Output Capacitance) 100 KHz, IIN= 15 mA Normally On solid state switches are electronic replacements for the conventional normally On electromechanical-relay. BLOCK DIAGRAM 100 pF 800-284-7007 • www.teledynerelays.com Page 51 C62 ENVIRONMENTAL SPECIFICATIONS OUTPUT (LOAD) SPECIFICATION Min Typ Output high Max Units Input Dielectric Withstanding Voltage 750 Input Junction Temperature (TJ Max) 125 o 100 o Vrms Output Low Storage Temperature -40 Thermal Resistance Junction to Ambient (θJA) 125 Weight 1.0 C C WIRING DIAGRAM C/W Figure 2 o gm MECHANICAL SPECIFICATIONS TYPICAL INPUT FORWARD CURRENT VS. FORWARD VOLTAGE Figure 3 TYPICAL TURN-OFF TIME VS. INPUT CURRENT Figure 4 NOTES: 1. 2. 3. 4. Figure 1 Page 52 Series resistor is required to limit input current to 50 ma maximum. The input current is 15 ma tests unless otherwise specified. Loads may be connected to positive or negative referenced power supplies. Inductive loads must be diode suppressed. Continuous load current is rated under the conditions of still air and mounted on a printed circuit board. SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE © 2000 TELEDYNE RELAYS