TFS915D

Filename: tfs 915d.doc
Version 1.2
VI TELEFILTER
14.12.2006
Filter specification
TFS 915D
1/5
Measurement condition
Ambient temperature:
Input power level:
Terminating impedance:
Input:
Output:
23
0
°C
dBm
50
50
Ω
Ω
Characteristics
Remark:
The maximum attenuation in the pass band is defined as the insertion loss ae. The nominal frequency fN is fixed at 915,0 MHz without any tolerance or
limit. The values of absolute attenuation aabs are guaranteed for the whole operating temperature range. The frequency shift of the filter in the operating
temperature range is included in the production tolerance scheme.
Data
typ. value
Insertion loss
Insertion loss in OTR2
ae
2,7
-
Nominal frequency
fN
-
PB
Passband
MHz
MHz
MHz
MHz
… 880
… 935
… 935
… 1900
max.
max.
3,0
3,5
915,0
dB
dB
MHz
12,5
MHz
fN
44
34
43
dB
dB
min.
min.
min.
min.
40
16
12
40
dB
dB
dB
dB
max.
10
dBm
± 3,5
MHz
aabs
Absolute attenuation
0,3
928
928
935
dB
tolerance / limit
MHz
MHz
MHz
MHz
in OTR2
dB
Input power level
Operating temperature range
OTR
-
- 10 °C ... + 60 °C
Operating temperature range 2
OTR2
-
- 40 °C ... + 85 °C
TCf *
-37
-
Storage temperature range
Temperature coefficient of frequency
- 40 °C ... + 85 °C
ppm/K
*) ∆f(Hz) = TCf(ppm/K) x (T-T0) x fTo(MHz)
Generated:
Checked / Approved:
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 915d.doc
Version 1.2
VI TELEFILTER
14.12.2006
Filter specification
TFS 915D
2/5
0
0
-10
-1
-20
-2
-30
-3
magnitude in dB
magnitude in dB
Filter characteristic
-40
-50
-60
-4
-5
-6
-70
-7
-80
-8
-90
-9
-100
50
240
430
620
810
1000
1190
frequency in MHz
1380
1570
1760
-10
905
1950
907
909
911
913
915
917
frequency in MHz
919
921
923
925
Construction and pin connection
(All dimensions in mm)
6
5
4
1,2 Max.
915D
● U50
Date code:
U
V
W
...
Year + week
2006
2007
2008
Date code
3
0,75
0,30X0,30
1
3,0 +/-0,15
Ground
Input
Ground
Ground
Output
Ground
3
2
1
1
2
3
4
5
6
0,6
6
4
0,6
50 Ω Test circuit
L1
2
5
L2
SAW
1, 3, 4, 6
VI TELEFILTER
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information
Filename: tfs 915d.doc
Version 1.2
VI TELEFILTER
14.12.2006
Filter specification
TFS 915D
3/5
Stability characteristics, reliability
After the following tests the filter shall meet the whole specification:
1. Shock:
500g, 1 ms, half sine wave, 3 shocks each plane;
DIN IEC 68 T2 - 27
2. Vibration:
10 Hz to 500 Hz, 0,35 mm or 5 g respectively, 1 octave per min, 10 cycles per plan, 3 plans;
DIN IEC 68 T2 - 6
3. Change of
temperature:
4. Resistance to
solder heat (reflow):
-55 °C to 125°C / 30 min. each / 10 cycles
DIN IEC 68 part 2 – 14 Test N
reflow possible: three times max.;
for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4;
This filter is RoHS compliant (2002/95/EG, 2005/618/EG)
Packing
Tape & Reel:
IEC 286 – 3, with exception of value for N and minimum bending radius;
tape type II, embossed carrier tape with top cover tape on the upper side;
max. pieces of filters per reel:
reel of empty components at start:
reel of empty components at start including leader:
trailer:
9000
min. 300 mm
min. 500 mm
min. 300 mm
Pull Off Direction
Tape (all dimensions in mm)
W
: 8,00 ± 0,3
Po
: 4,00 ± 0,1
Do
: 1,50 +0,1/-0
E
: 1,75 ± 0,1
F
: 3,50 ± 0,05
G(min)
: 0,75
P2
: 2,00 ± 0,05
P1
: 4,00 ± 0,1
D1(min)
: 1,50
Ao
: 3,25 ± 0,1
Bo
: 3,25 ± 0,1
Ct
: 5,5 ± 0,1
P1
Date Code
Po
Do
P2
W
G
Ct
Bo
F
G
E
t
Ko
Typ
PIN Marker
D1
Ao
W 2
Reel (all dimensions in mm)
A
: 330
W1
: 8,4 +1,5/-0
W2(max) : 14,4
N(min)
: 50
C
: 13,0 +0,5/-0,2
A
C
N
W 1
The minimum bending radius is 45 mm.
VI TELEFILTER
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information
Filename: tfs 915d.doc
Version 1.2
VI TELEFILTER
14.12.2006
Filter specification
TFS 915D
4/5
Air reflow temperature conditions
Conditions
Average ramp-up rate (30°C to 217°C)
> 100°C
> 150°C
> 217°C
Peak temperature
Time within 5°C of actual peak temperature
Cool-down rate (Peak to 50°C)
Time from 30°C to Peak temperature
Exposure
less than 3°C/second
between 300 and 600 seconds
between 240 and 500 seconds
between 30 and 150 seconds
max. 260°C
between 10 and 30 seconds
less than 6°C/second
no greater than 300 seconds
Chip-mount air reflow profile
Temperature / °C
max. 260°C
217°C
max. 300 s
10 ... 30 s
Time / s
30 ... 150 s
VI TELEFILTER
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information
Filename: tfs 915d.doc
VI TELEFILTER
Version 1.2
Filter specification
14.12.2006
TFS 915D
5/5
History
Version
Reason of Changes
Name
Date
1.0
- Generation of development specification
M.Springfeldt
07.06.2004
1.1
- Add typical values and filter characteristic
- Generation of filter specification
Strehl
30.06.2005
1.2
- Add OTR2 and change stability characteristics
Strehl
14.12.2006
VI TELEFILTER
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information