Filename: tfs 416.doc Version 1.2 VI TELEFILTER 12.09.2006 Filter specification TFS 416 1/5 Measurement condition Ambient temperature: Input power level: Terminating impedance: * Input: Output: 23 0 200 200 °C dBm Ω Ω Characteristics Remark: The nominal frequency fN is fixed at 416,0 MHz. The insertion loss ae is defined as loss value determined at fN. All specified data are met within the operating temperature range. Data typ. value Insertion loss (reference level) ae 1,6 dB Nominal frequency fN - Centre frequency fC 416,0 MHz 9,7 MHz Bandwidth 3 tolerance / limit max. 3,5 416,0 dB MHz BW dB Absolute attenuation - aabs fN fN fN fN fN fN fN fN fN fN fN fN fN fN fN fN fN fN fN fN fN fN fN fN fN fN fN fN + + + + + + + + + + + + + 1,28 51,84 52,00 103,68 104,00 155,52 156,00 207,36 208,00 259,20 260,00 311,04 312,00 362,88 364,00 51,84 52,00 103,68 104,00 155,52 156,00 207,36 208,00 259,20 260,00 311,04 312,00 362,88 MHz MHz MHz MHz MHz MHz MHz MHz MHz MHz MHz MHz MHz MHz MHz MHz MHz MHz MHz MHz MHz MHz MHz MHz MHz MHz MHz MHz 2,5 59 59 57 57 56 56 58 58 59 59 62 62 60 60 55 55 56 56 54 54 58 58 60 60 62 62 64 dB dB dB dB dB dB dB dB dB dB dB dB dB dB dB dB dB dB dB dB dB dB dB dB dB dB dB dB max. min. min. min. min. min. min. min. min. min. min. min. min. min. min. min. min. min. min. min. min. min. min. min. min. min. min. min. 4,5 50 50 50 50 50 50 50 50 51 51 51 51 52 52 48 48 48 48 48 48 48 48 49 49 50 50 50 dB dB dB dB dB dB dB dB dB dB dB dB dB dB dB dB dB dB dB dB dB dB dB dB dB dB dB dB fN + 364,00 MHz 64 dB min. 50 dB - max. 10 dBm - - 40 °C ... + 85 °C Input power level Operating temperature range OTR Storage temperature range Temperature coefficient of frequency TCf * - 32 - 45 °C ... + 95 °C ppm/K *) ∆f(Hz) = TCf(ppm/K) x (T-T0) x fTo(MHz). Generated: Checked / Approved: Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: tfs 416.doc Version 1.2 VI TELEFILTER 12.09.2006 Filter specification TFS 416 2/5 0 0 -10 -0.5 -20 -1 -30 -1.5 magnitude in dB magnitude in dB Filter characteristic -40 -50 -60 -2 -2.5 -3 -70 -3.5 -80 -4 -90 -4.5 -100 100 200 300 400 500 frequency in MHz 600 700 -5 800 410 411 412 413 414 415 416 frequency in MHz 417 418 419 420 Construction and pin connection (All dimensions in mm) 6 7 416 ● U37 8 2 1 1,2 Max. 5 4 3 Date code 7 3,0 +/-0,15 0,6 d. Gr 60 0,6 Ground Input Ground Ground Ground Output Ground Ground Date code: U V W ... Year + week 2006 2007 2008 3 1,5 1 1 2 3 4 5 6 7 8 5 0,6 200 Ω Test circuit L1 2 6 L2 SAW 1, 3, 4, 5, 7, 8 Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: tfs 416.doc Version 1.2 VI TELEFILTER 12.09.2006 Filter specification TFS 416 3/5 Stability characteristics, reliability After the following tests the filter shall meet the whole specification: 1. Shock: 500g, 1 ms, half sine wave, 3 shocks each plane; DIN IEC 68 T2 - 27 2. Vibration: 10 Hz to 500 Hz, 0,35 mm or 5 g respectively, 1 octave per min, 10 cycles per plan, 3 plans; DIN IEC 68 T2 - 6 3. Change of temperature: 4. Resistance to solder heat (reflow): -55 °C to 125°C / 30 min. each / 10 cycles DIN IEC 68 part 2 – 14 Test N reflow possible: three times max.; for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4; This filter is RoHS compliant (2002/95/EG, 2005/618/EG) Packing Tape & Reel: IEC 286 – 3, with exception of value for N and minimum bending radius; tape type II, embossed carrier tape with top cover tape on the upper side; max. pieces of filters per reel: reel of empty components at start: reel of empty components at start including leader: trailer: 9000 min. 300 mm min. 500 mm min. 300 mm Pull Off Direction Tape (all dimensions in mm) W : 8,00 ± 0,3 Po : 4,00 ± 0,1 Do : 1,50 +0,1/-0 E : 1,75 ± 0,1 F : 3,50 ± 0,05 G(min) : 0,75 P2 : 2,00 ± 0,05 P1 : 4,00 ± 0,1 D1(min) : 1,50 Ao : 3,25 ± 0,1 Bo : 3,25 ± 0,1 Ct : 5,5 ± 0,1 P1 Date Code Po Do P2 W G Ct Bo F G E t Ko Typ PIN Marker D1 Ao W 2 Reel (all dimensions in mm) A : 330 W1 : 8,4 +1,5/-0 W2(max) : 14,4 N(min) : 50 C : 13,0 +0,5/-0,2 A C N W 1 The minimum bending radius is 45 mm. Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: tfs 416.doc Version 1.2 VI TELEFILTER 12.09.2006 Filter specification TFS 416 4/5 Air reflow temperature conditions Conditions Average ramp-up rate (30°C to 217°C) > 100°C > 150°C > 217°C Peak temperature Time within 5°C of actual peak temperature Cool-down rate (Peak to 50°C) Time from 30°C to Peak temperature Exposure less than 3°C/second between 300 and 600 seconds between 240 and 500 seconds between 30 and 150 seconds max. 260°C between 10 and 30 seconds less than 6°C/second no greater than 300 seconds Chip-mount air reflow profile Temperature / °C max. 260°C 217°C max. 300 s 10 ... 30 s Time / s 30 ... 150 s Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: tfs 416.doc VI TELEFILTER Version 1.2 Filter specification 12.09.2006 TFS 416 5/5 History Version Reason of Changes Name Date 1.0 - Generation of development specification Strehl 18.05.2006 1.1 - Add absolute attenuation Strehl 25.07.2006 1.2 - Add typical values, add filter characteristic - Generation of filter specification Channaa 12.09.2006 Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.