VECTRON TFS416

Filename: tfs 416.doc
Version 1.2
VI TELEFILTER
12.09.2006
Filter specification
TFS 416
1/5
Measurement condition
Ambient temperature:
Input power level:
Terminating impedance: *
Input:
Output:
23
0
200
200
°C
dBm
Ω
Ω
Characteristics
Remark:
The nominal frequency fN is fixed at 416,0 MHz. The insertion loss ae is defined as loss value determined at fN. All specified data are met within the
operating temperature range.
Data
typ. value
Insertion loss
(reference level)
ae
1,6
dB
Nominal frequency
fN
-
Centre frequency
fC
416,0
MHz
9,7
MHz
Bandwidth
3
tolerance / limit
max.
3,5
416,0
dB
MHz
BW
dB
Absolute attenuation
-
aabs
fN
fN
fN
fN
fN
fN
fN
fN
fN
fN
fN
fN
fN
fN
fN
fN
fN
fN
fN
fN
fN
fN
fN
fN
fN
fN
fN
fN
+
+
+
+
+
+
+
+
+
+
+
+
+
1,28
51,84
52,00
103,68
104,00
155,52
156,00
207,36
208,00
259,20
260,00
311,04
312,00
362,88
364,00
51,84
52,00
103,68
104,00
155,52
156,00
207,36
208,00
259,20
260,00
311,04
312,00
362,88
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
2,5
59
59
57
57
56
56
58
58
59
59
62
62
60
60
55
55
56
56
54
54
58
58
60
60
62
62
64
dB
dB
dB
dB
dB
dB
dB
dB
dB
dB
dB
dB
dB
dB
dB
dB
dB
dB
dB
dB
dB
dB
dB
dB
dB
dB
dB
dB
max.
min.
min.
min.
min.
min.
min.
min.
min.
min.
min.
min.
min.
min.
min.
min.
min.
min.
min.
min.
min.
min.
min.
min.
min.
min.
min.
min.
4,5
50
50
50
50
50
50
50
50
51
51
51
51
52
52
48
48
48
48
48
48
48
48
49
49
50
50
50
dB
dB
dB
dB
dB
dB
dB
dB
dB
dB
dB
dB
dB
dB
dB
dB
dB
dB
dB
dB
dB
dB
dB
dB
dB
dB
dB
dB
fN
+
364,00
MHz
64
dB
min.
50
dB
-
max.
10
dBm
-
- 40 °C ... + 85 °C
Input power level
Operating temperature range
OTR
Storage temperature range
Temperature coefficient of frequency
TCf *
- 32
- 45 °C ... + 95 °C
ppm/K
*) ∆f(Hz) = TCf(ppm/K) x (T-T0) x fTo(MHz).
Generated:
Checked / Approved:
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 416.doc
Version 1.2
VI TELEFILTER
12.09.2006
Filter specification
TFS 416
2/5
0
0
-10
-0.5
-20
-1
-30
-1.5
magnitude in dB
magnitude in dB
Filter characteristic
-40
-50
-60
-2
-2.5
-3
-70
-3.5
-80
-4
-90
-4.5
-100
100
200
300
400
500
frequency in MHz
600
700
-5
800
410
411
412
413
414
415
416
frequency in MHz
417
418
419
420
Construction and pin connection
(All dimensions in mm)
6
7
416
● U37
8
2
1
1,2 Max.
5
4
3
Date code
7
3,0 +/-0,15
0,6
d.
Gr
60
0,6
Ground
Input
Ground
Ground
Ground
Output
Ground
Ground
Date code:
U
V
W
...
Year + week
2006
2007
2008
3
1,5
1
1
2
3
4
5
6
7
8
5
0,6
200 Ω Test circuit
L1
2
6
L2
SAW
1, 3, 4, 5, 7, 8
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 416.doc
Version 1.2
VI TELEFILTER
12.09.2006
Filter specification
TFS 416
3/5
Stability characteristics, reliability
After the following tests the filter shall meet the whole specification:
1. Shock:
500g, 1 ms, half sine wave, 3 shocks each plane;
DIN IEC 68 T2 - 27
2. Vibration:
10 Hz to 500 Hz, 0,35 mm or 5 g respectively, 1 octave per min, 10 cycles per plan, 3 plans;
DIN IEC 68 T2 - 6
3. Change of
temperature:
4. Resistance to
solder heat (reflow):
-55 °C to 125°C / 30 min. each / 10 cycles
DIN IEC 68 part 2 – 14 Test N
reflow possible: three times max.;
for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4;
This filter is RoHS compliant (2002/95/EG, 2005/618/EG)
Packing
Tape & Reel:
IEC 286 – 3, with exception of value for N and minimum bending radius;
tape type II, embossed carrier tape with top cover tape on the upper side;
max. pieces of filters per reel:
reel of empty components at start:
reel of empty components at start including leader:
trailer:
9000
min. 300 mm
min. 500 mm
min. 300 mm
Pull Off Direction
Tape (all dimensions in mm)
W
: 8,00 ± 0,3
Po
: 4,00 ± 0,1
Do
: 1,50 +0,1/-0
E
: 1,75 ± 0,1
F
: 3,50 ± 0,05
G(min)
: 0,75
P2
: 2,00 ± 0,05
P1
: 4,00 ± 0,1
D1(min)
: 1,50
Ao
: 3,25 ± 0,1
Bo
: 3,25 ± 0,1
Ct
: 5,5 ± 0,1
P1
Date Code
Po
Do
P2
W
G
Ct
Bo
F
G
E
t
Ko
Typ
PIN Marker
D1
Ao
W 2
Reel (all dimensions in mm)
A
: 330
W1
: 8,4 +1,5/-0
W2(max) : 14,4
N(min)
: 50
C
: 13,0 +0,5/-0,2
A
C
N
W 1
The minimum bending radius is 45 mm.
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 416.doc
Version 1.2
VI TELEFILTER
12.09.2006
Filter specification
TFS 416
4/5
Air reflow temperature conditions
Conditions
Average ramp-up rate (30°C to 217°C)
> 100°C
> 150°C
> 217°C
Peak temperature
Time within 5°C of actual peak temperature
Cool-down rate (Peak to 50°C)
Time from 30°C to Peak temperature
Exposure
less than 3°C/second
between 300 and 600 seconds
between 240 and 500 seconds
between 30 and 150 seconds
max. 260°C
between 10 and 30 seconds
less than 6°C/second
no greater than 300 seconds
Chip-mount air reflow profile
Temperature / °C
max. 260°C
217°C
max. 300 s
10 ... 30 s
Time / s
30 ... 150 s
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 416.doc
VI TELEFILTER
Version 1.2
Filter specification
12.09.2006
TFS 416
5/5
History
Version
Reason of Changes
Name
Date
1.0
- Generation of development specification
Strehl
18.05.2006
1.1
- Add absolute attenuation
Strehl
25.07.2006
1.2
- Add typical values, add filter characteristic
- Generation of filter specification
Channaa
12.09.2006
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.