Tfs156A.doc version 1.2 VI TELEFILTER 30.01.2002 Filter Specification TFS 156A 1/5 Measurement condition Ambient temperature: 23 °C Input power level: 0 dBm Terminating impedances *): Input : 615 Ω║ -1,25 pF Output : 615 Ω║ -1,25 pF Characteristics Remark: Reference level for the relative attenuation arel of the TFS156A is the minimum of the pass band attenuation amin. The minimum of the pass band attenuation amin is defined as the insertion loss ae. The centre frequency fc is the arithmetic mean value of the upper and lower frequencies at the 3dB filter attenuation level relative to the insertion loss ae. The nominal frequency fN is fixed at 156,525 MHz without any tolerance. The given values for the relative attenuation arel have to be reached at the frequencies given below even if the centre frequency fc is shifted due to the temperature coefficient of frequency TCf in the operating temperature range and due to a production tolerance for the centre frequency fc Data typ. value Insertion loss (Reference level) ae 2,6 - Nominal frequency fN Centre frequency fc Relative attenuation 25 kHz fN ± 125 kHz... fN ± fN ± @ fN ± 450 kHz arel max. 1,1 31 65 Temperature coefficient of frequency TCf **) To dB dB dB - 0,036 ppm/K² + 22 5 dB 156,525 MHz - 156,538 MHz 450 kHz Frequency inversion temperature dB tolerance / limit °C max. min. min. 3 20 60 dB dB dB - Operating Temperature Range -40 °C ... + 85 °C Storage Temperature Range -54 °C ..+ 100 °C * ) The terminating impedances depend on parasitics and q-values of matching elements and the board used, and are to be understood as reference values only. Should there be additional questions do not hesitate to ask for an application note or contact our design team. **) ∆f(Hz) = TCf(ppm/K²) x (∆T)² x fTo(MHz) generated: checked / approved: VI TELEFILTER Vectron International , Inc. Potsdamer Straße 18 267 Lowell Road D 14 513 TELTOW / Germany Hudson, NH 03051 / USA Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: [email protected] E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Tfs156A.doc version 1.2 VI TELEFILTER 30.01.2002 Filter Specification TFS 156A 2/5 Construction, pin connection and 50 Ω - matching network 1 Ground Ground 2 Output 3 Ground Ground 5 Ground Ground TFS 156A P05 Date code 1 2 6 7 Input 8 9 Date Code: M N P ... 3 Year + week 2000 2001 2002 4 10 9 5 8 7 6 50 Ohm matching networks C1 C2 2 7 L1 L2 1,3,4,5,6,8,9,10 L3 2 7 C3 L4 C4 1,3,4,5,6,8,9,10 VI TELEFILTER Vectron International , Inc. Potsdamer Straße 18 267 Lowell Road D 14 513 TELTOW / Germany Hudson, NH 03051 / USA Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: [email protected] E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Tfs156A.doc version 1.2 VI TELEFILTER 30.01.2002 Filter Specification TFS 156A 3/5 Stability Characteristics After the following tests the filter shall meet the whole specification: 1. Shock: 500g, 18 ms, half sine wave, 3 shocks each plane; DIN IEC 68 T2 - 27 2. Vibration: 10 Hz to 500 Hz, 0,35 mm or 5g respectively, 1 octave per min, 10 cycles per plan, 3 plans; DIN IEC 68 T2 - 6 3. Change of temperature: -55 °C to 125°C / 30 min. each / 10 cycles DIN IEC 68 part 2 – 14 Test N 4. Resistance to solder heat (reflow): reflow possible: twice max.; for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4; Packing Tape & Reel: IEC 286 - 3, with exception of value for N and minimum bending radius; tape type II, embossed carrier tape with top cover tape on the upper side; max. pieces of filters per reel: reel of empty components at start: reel of empty components at start including leader: trailer Tape (all dimensions in mm) W Po Do : : : 16 ± 0,3 4 ± 0,1 1,5 + 0,1 E : F : G (min) : 1,75 ± 0,1 7,5 ± 0,1 0,6 P2 : P1 : D1(min) : 2 12 1,5 Ao Bo CT 7,6 ± 0,1 9,6 ± 0,1 13,5 + 0,1 : : : ± 0,1 ± 0,1 2000 min 300 mm min 500 mm min 300 mm EMBOSSED CARRIER TAPE Do Po P2 E Ao F D1 CT W Bo G P1 COVER TAPE W 2 Reel (all dimensions in mm): A : 330 W1 : 16,4 +2 W2 (m ax) : N (m in) C : : 22,4 60 12,8 ± 0,1 A C N W 1 The minimum bending radius is 45 mm. The mounting surface of the filters faces the bottom side of the embossed carrier tape. Markings on the filters can be read if the upper side of the carrier tape is regarded with the sprocket holes on its right. VI TELEFILTER Vectron International , Inc. Potsdamer Straße 18 267 Lowell Road D 14 513 TELTOW / Germany Hudson, NH 03051 / USA Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: [email protected] E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Tfs156A.doc version 1.2 VI TELEFILTER 30.01.2002 Filter Specification TFS 156A 4/5 Air reflow temperature conditions 1st and 2nd air reflow profile Name: Temperature: Time: pre-heating periods 150 °C - 170 °C 60 sec. - 90 sec. main-heating periods over 200 °C 20 sec. - 25 sec. peak temperature 255 °C ± 5 °C Chip-mount air reflow profile 260 240 220 200 temperature / °C 180 160 140 120 100 80 60 40 20 0 0 20 40 60 80 100 120 140 160 180 200 220 240 time / sec. Table for temperature vs. time during the air reflow process Tolerance of temperatures: ± 5 °C time / sec. 0 10 20 30 40 50 60 70 80 90 100 110 120 130 temperature / °C 23 34 46 60 80 103 121 134 143 150 154 156 158 159 time / sec. 140 150 160 170 180 190 195 200 205 210 215 220 230 240 temperature / °C 160 161 164 170 180 205 230 255 230 205 180 165 140 120 VI TELEFILTER Vectron International , Inc. Potsdamer Straße 18 267 Lowell Road D 14 513 TELTOW / Germany Hudson, NH 03051 / USA Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: [email protected] E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Tfs156A.doc version 1.2 VI TELEFILTER Filter Specification 30.01.2002 TFS 156A 5/5 History Version Reason of Changes Name Date 1.0 Generation of specification according to customer requirement specification. Pfeiffer 22.06.2001 1.1 Correct frequency for 60 dB attenuation. Dr Wall 25.06.2001 1.2 Change from development specification to filter specification. Add termination impedances. Add typical data. Correct pinning in matching network. Dr. Wall 30.01.2002 VI TELEFILTER Vectron International , Inc. Potsdamer Straße 18 267 Lowell Road D 14 513 TELTOW / Germany Hudson, NH 03051 / USA Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: [email protected] E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.