VECTRON TFS156A

Tfs156A.doc
version 1.2
VI TELEFILTER
30.01.2002
Filter Specification
TFS 156A
1/5
Measurement condition
Ambient temperature:
23 °C
Input power level:
0 dBm
Terminating impedances *):
Input :
615 Ω║ -1,25 pF
Output : 615 Ω║ -1,25 pF
Characteristics
Remark:
Reference level for the relative attenuation arel of the TFS156A is the minimum of the pass band attenuation amin. The minimum of the pass band
attenuation amin is defined as the insertion loss ae. The centre frequency fc is the arithmetic mean value of the upper and lower frequencies at the
3dB filter attenuation level relative to the insertion loss ae. The nominal frequency fN is fixed at 156,525 MHz without any tolerance. The given
values for the relative attenuation arel have to be reached at the frequencies given below even if the centre frequency fc is shifted due to the
temperature coefficient of frequency TCf in the operating temperature range and due to a production tolerance for the centre frequency fc
Data
typ. value
Insertion loss
(Reference level)
ae
2,6
-
Nominal frequency
fN
Centre frequency
fc
Relative attenuation
25 kHz
fN ±
125 kHz... fN ±
fN ±
@ fN ± 450 kHz
arel
max.
1,1
31
65
Temperature coefficient of frequency TCf **)
To
dB
dB
dB
- 0,036 ppm/K²
+ 22
5
dB
156,525 MHz
-
156,538 MHz
450 kHz
Frequency inversion temperature
dB
tolerance / limit
°C
max.
min.
min.
3
20
60
dB
dB
dB
-
Operating Temperature Range
-40 °C ... + 85
°C
Storage Temperature Range
-54 °C ..+ 100
°C
* ) The terminating impedances depend on parasitics and q-values of matching elements and the board used, and are to be understood as
reference values only. Should there be additional questions do not hesitate to ask for an application note or contact our design team.
**) ∆f(Hz) = TCf(ppm/K²) x (∆T)² x fTo(MHz)
generated:
checked / approved:
VI TELEFILTER
Vectron International , Inc.
Potsdamer Straße 18
267 Lowell Road
D 14 513 TELTOW / Germany
Hudson, NH 03051 / USA
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: [email protected]
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Tfs156A.doc
version 1.2
VI TELEFILTER
30.01.2002
Filter Specification
TFS 156A
2/5
Construction, pin connection and 50 Ω - matching network
1 Ground
Ground
2 Output
3 Ground
Ground
5 Ground
Ground
TFS 156A
P05
Date code
1
2
6
7 Input
8
9
Date Code:
M
N
P
...
3
Year + week
2000
2001
2002
4
10
9
5
8
7
6
50 Ohm matching networks
C1
C2
2
7
L1
L2
1,3,4,5,6,8,9,10
L3
2
7
C3
L4
C4
1,3,4,5,6,8,9,10
VI TELEFILTER
Vectron International , Inc.
Potsdamer Straße 18
267 Lowell Road
D 14 513 TELTOW / Germany
Hudson, NH 03051 / USA
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: [email protected]
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Tfs156A.doc
version 1.2
VI TELEFILTER
30.01.2002
Filter Specification
TFS 156A
3/5
Stability Characteristics
After the following tests the filter shall meet the whole specification:
1. Shock:
500g, 18 ms, half sine wave, 3 shocks each plane;
DIN IEC 68 T2 - 27
2. Vibration:
10 Hz to 500 Hz, 0,35 mm or 5g respectively, 1 octave per min, 10 cycles per plan, 3 plans;
DIN IEC 68 T2 - 6
3. Change of
temperature:
-55 °C to 125°C / 30 min. each / 10 cycles
DIN IEC 68 part 2 – 14 Test N
4. Resistance to
solder heat (reflow):
reflow possible: twice max.;
for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4;
Packing
Tape & Reel:
IEC 286 - 3, with exception of value for N and minimum bending radius;
tape type II, embossed carrier tape with top cover tape on the upper side;
max. pieces of filters per reel:
reel of empty components at start:
reel of empty components at start including leader:
trailer
Tape (all dimensions in mm)
W
Po
Do
:
:
:
16
± 0,3
4
± 0,1
1,5 + 0,1
E
:
F
:
G (min) :
1,75 ± 0,1
7,5 ± 0,1
0,6
P2
:
P1
:
D1(min) :
2
12
1,5
Ao
Bo
CT
7,6 ± 0,1
9,6 ± 0,1
13,5 + 0,1
:
:
:
± 0,1
± 0,1
2000
min 300 mm
min 500 mm
min 300 mm
EMBOSSED CARRIER TAPE
Do
Po
P2
E
Ao
F
D1
CT
W
Bo
G
P1
COVER TAPE
W 2
Reel (all dimensions in
mm):
A
:
330
W1
:
16,4 +2
W2 (m ax) :
N (m in)
C
:
:
22,4
60
12,8 ± 0,1
A
C
N
W 1
The minimum bending radius is 45 mm. The mounting surface of the filters faces the bottom side of the embossed carrier tape.
Markings on the filters can be read if the upper side of the carrier tape is regarded with the sprocket holes on its right.
VI TELEFILTER
Vectron International , Inc.
Potsdamer Straße 18
267 Lowell Road
D 14 513 TELTOW / Germany
Hudson, NH 03051 / USA
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: [email protected]
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Tfs156A.doc
version 1.2
VI TELEFILTER
30.01.2002
Filter Specification
TFS 156A
4/5
Air reflow temperature conditions
1st and 2nd air reflow profile
Name:
Temperature:
Time:
pre-heating periods
150 °C - 170 °C
60 sec. - 90 sec.
main-heating periods
over 200 °C
20 sec. - 25 sec.
peak temperature
255 °C ± 5 °C
Chip-mount air reflow profile
260
240
220
200
temperature / °C
180
160
140
120
100
80
60
40
20
0
0
20
40
60
80
100
120
140
160
180
200
220
240
time / sec.
Table for temperature vs. time during the air reflow process
Tolerance of temperatures: ± 5 °C
time / sec.
0
10
20
30
40
50
60
70
80
90
100
110
120
130
temperature / °C
23
34
46
60
80
103
121
134
143
150
154
156
158
159
time / sec.
140
150
160
170
180
190
195
200
205
210
215
220
230
240
temperature / °C
160
161
164
170
180
205
230
255
230
205
180
165
140
120
VI TELEFILTER
Vectron International , Inc.
Potsdamer Straße 18
267 Lowell Road
D 14 513 TELTOW / Germany
Hudson, NH 03051 / USA
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: [email protected]
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Tfs156A.doc
version 1.2
VI TELEFILTER
Filter Specification
30.01.2002
TFS 156A
5/5
History
Version
Reason of Changes
Name
Date
1.0
Generation of specification according to customer requirement specification.
Pfeiffer
22.06.2001
1.1
Correct frequency for 60 dB attenuation.
Dr Wall
25.06.2001
1.2
Change from development specification to filter specification.
Add termination impedances.
Add typical data.
Correct pinning in matching network.
Dr. Wall
30.01.2002
VI TELEFILTER
Vectron International , Inc.
Potsdamer Straße 18
267 Lowell Road
D 14 513 TELTOW / Germany
Hudson, NH 03051 / USA
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: [email protected]
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.