Maintenance-Free Rechargeable Sealed Lead-Acid Battery BP35-12(H)(F) (H):Handle Type (F):Finger Type The battery is constructed by plates, separators, safety valves and container. Since the electrolyte is held by a glass-mat separator and plates, the battery can use in any direction and position without leakage. PERFORMANCE SPECIFICATIONS Nominal Voltage(V)................................................................................................................12 volts(6cells in series) Nominal Capacity(AH) 20 hour rate F.V.(1.75V/cell) (1750mA to 10.50volts) ..................................................................................35A.H. 10 hour rate F.V.(1.75V/cell) (3325mA to 10.50volts) .............................................................................33.25A.H. 5 hour rate F.V.(1.75V/cell) (5950mA to 10.50volts) ...............................................................................29.8A.H. 1 hour rate F.V.(1.55V/cell) (21000mA to 9.30volts)................................................................................21.0A.H. Approximate Weight........................................................................................................................11790g(26.00lbs.) Terminal Standard...................................................................................................................................................Type B2-1 Internal Resistance (Fully Charged Battery)......................................................................................................<9m Maximum Discharge Current For 5 sec.(A)..........................................................................................................525A Maximum Charge Current(A)..............................................................................................................................10.5A Ambient Temperature Charge..................................................................................................................................0oC(32oF)~40oC(104oF) Discharge...........................................................................................................................-20oC(-4oF)~50oC(122oF) Storage...............................................................................................................................-20oC(-4oF)~40oC(104oF) Vibration test: Frequency: 16.7HZ Amplitude: 4mm Vibrate the battery horizontally or vertically for 60 minutes. The battery have no abnormality. Case......................................................................................................................................................................ABS Dimension(mm/inch) Length 1.5mm.........................................................................................................................210/8.27 Width 1.5mm.........................................................................................................................129/5.08 Container Height 1.5mm.........................................................................................................................168/6.61 Total Height 2mm............................................................................................................................179/7.05 Application..........................................Wheelchairs, Lawn Mowers, Electronic Medical Equipment, UPS, Golf-Carts. BP35-12(H)(F) Battery discharge characteristics (25 OC/77 OF) BATTERY CHARGING CHARACTERISTICS (Typical example of the charge characteristics for the standby use) 13.0 140 0.21 15.0 120 0.18 14.0 100 0.15 13.0 Charge voltage 5.95A 3.33A 1.75A 8.75A 10.0 21.0A 9.0 80 60 40 Charge voltage(V) 11.0 Charge current(CA) Charge volume(%) Terminal Voltage(V) 12.0 0.12 0.09 0.06 20 0.03 0 0 C ha rg e 1 Discharge 100 %(0.05CA x 20h) 50 %(0.05CA x 10h) 2 Constant voltage charging Charge voltage:2.275V/cell Charge current:0.1CA O O 3 Temperature:20 C(68 F) 12.0 11.0 10.0 8.0 105A 70A Charge current 35A 0 0 7.0 1 2 3 5 10 20 30 60 2 5 3 10 20 20 25 Effect of Temperature on Long Term Float Life 10 8 Temperature Charging compensation Voltage coefficient of at 20OC voltage (V/cell) charging (mV/ OC/cell) 2.25~2.30 -3 Charging time O 0.1CA, 20 C (h) Max. charging current (CA) 100% discharge 24 0.3 Temp O ( C) 50% discharge 20 0~40 O (32~104 F) -4 2.40~2.50 0.3 16 6 5 4 Life expectancy(year) For cycle service Constant voltage & Constant current charging (with current restrication) 15 Charge time (hr) Charging Procedure For standby power Source 10 30 Discharge time Charging method 5 Hr Min Application vo lu m e Charging voltage : 2.275V/cell 3 2 1 10 O 0.5 O *Temperature compensation of charging voltage is not needed, when using the batteries within 5 C to 35 C range. 20 68 30 86 50 oC 122 oF 40 104 Battery temperature TERMINAL TYPE OUTER DIMENSIONS mm(inch) Constant power discharge characteristics at 25 oC/77 oF mm(inch) Terminal B2-1 Discharge time 6.2(0.25) Final Voltage 6( 0.24) 14.9(0.59) 6.9(0.27) 16(0.63) 5Min 10Min 15Min 30Min 1Hr 5Hr 3Hr 10Hr 20Hr Battery output power(W) 10.80V 1265.4 931.6 746.5 444.2 254.73 102.02 70.34 39.31 20.55 10.50V 1464.7 1009.2 780.8 461.0 262.37 104.06 71.40 39.90 21.00 10.20V 1556.2 1045.5 805.0 471.6 267.09 105.00 71.79 40.10 21.10 9.90V 1626.1 1070.6 823.5 478.2 270.30 105.73 72.04 40.22 21.15 9.60V 1680.0 1092.0 840.0 483.0 273.00 106.37 72.26 40.22 21.15 [M5 BOLT & NUT] 210 1.5(8.27 0.06) 196 1.5(7.68 0.06) TERMINAL POSITION 179 2(7.05 0.08) 168 1.5(6.61 0.06) 129 1.5(5.08 0.06) UL R MH19884 B.B. BATTERY CO., LTD. Web Site: http://www.bb-battery.com USA : B&B BATTERY (USA) INC. 6415 RANDOLPH ST. COMMERCE, CA, 90040 U.S.A. TEL: 1-323-278-1900 . 1-800-278-8599 FAX: 1-323-278-1268 CHINA FACTORY: CHENG DONG TRIAL AREA, HUANG GANG, RAOPING GUANG DONG, CHINA, 515700 TEL: 86-768-7601001-2 FAX: 86-768-7601469 UK: JAPAN: B & B BATTERY (UK) CO., LTD. TEL: 44-161-339-9458 FAX: 44-161-343-7030 B & B BATTERY(JAPAN) CO., LTD. TEL: 81-426-256-537 FAX: 81-426-256-537 HONG KONG: TAIWAN: NATIONAL TRADING LTD. B & B BATTERY CO., LTD. TEL: 852-2301-3800 FAX: 852-2739-1182 TEL: 886-6-5898081~3 FAX: 886-6-5898087 QUALITY ASSURED FIRM NATIONAL ACCREDITATION OF CERTIFICATION BODIES I S O 1 4 0 0 1 UKAS ENVIRONMENTAL MANAGEMENT Reg. No. 059-C