BP1.2-12 Data

Maintenance-Free Rechargeable Sealed Lead-Acid Battery
BP1.2-12
The battery is constructed by plates,
separators, safety valves and container.
Since the electrolyte is held by a glassmat separator and plates, the battery
can use in any direction and position
without leakage.
PERFORMANCE SPECIFICATIONS
Nominal Voltage(V).......................................................................................................12 volts(6cells in series)
Nominal Capacity(AH)
20 hour rate F.V.(1.75V/cell)( 60mA to 10.50volts) ................................................................................1.2A.H.
10 hour rate F.V.(1.75V/cell)( 114mA to 10.50volts).............................................................................1.14A.H.
5 hour rate F.V.(1.75V/cell)( 204mA to 10.50volts) ............................................................................1.02A.H.
1 hour rate F.V.(1.55V/cell)( 720mA to 9.30volts)...............................................................................0.72A.H.
Approximate Weight......................................................................................................................590g(1.30lbs.)
Terminal
Standard......................................................................................................................................................T1
Internal Resistance (Fully Charged Battery)...........................................................................................<120m
Maximum Discharge Current For 5 sec.(A).....................................................................................................18A
Maximum Charge Current(A).......................................................................................................................0.36A
Ambient Temperature
Charge..........................................................................................................................0oC(32oF)~40oC(104oF)
Discharge...................................................................................................................-20oC(-4oF)~50oC(122oF)
Storage......................................................................................................................-20oC(-4oF)~40oC(104oF)
Vibration test:
Frequency: 16.7HZ
Amplitude: 4mm
Vibrate the battery horizontally or vertically for 60 minutes. The battery have no abnormality.
Case.............................................................................................................................................................ABS
Dimension(mm/inch)
Length
1.5mm...................................................................................................................97/3.82
Width
1.5mm...................................................................................................................45/1.77
Container Height
1.5mm...................................................................................................................53/2.09
Total Height
2mm......................................................................................................................59/2.32
Application.....................................................................................................................Security Alarm Systems.
O
O
BATTERY CHARGING CHARACTERISTICS
BP1.2-12 Battery discharge characteristics (25 C/77 F)
(Typical example of the charge characteristics for the standby use)
Terminal Voltage(V)
11.0
0.204A 0.114A 0.06A
0.3A
10.0
0.72A
9.0
8.0
3.6A
2.4A
0.21
15.0
120
0.18
14.0
100
0.15
13.0
80
60
40
Charge voltage(V)
Charge volume(%)
12.0
140
Charge current(CA)
13.0
0.12
0.09
0.06
20
0.03
0
0
Charge voltage
C ha rg e
1 Discharge
100 %(0.05CA x 20h)
50 %(0.05CA x 10h)
2 Constant voltage charging
Charge voltage:2.275V/cell
Charge current:0.1CA
O
O
3 Temperature:20 C(68 F)
12.0
11.0
10.0
Charge current
1.2A
7.0
0
0
1
2
3
5
10
20
30
60
2
3
5
10
20
For
cycle service
20
25
Effect of Temperature on Long Term Float Life
10
8
Temperature
Charging
Max. charging
compensation
Voltage
current
coefficient of
at 20OC
(CA)
charging
voltage
(V/cell)
(mV/ OC/cell)
2.25~2.30
-3
Charging time
O
0.1CA, 20 C
(h)
100%
discharge
24
0.3
Temp
O
( C)
50%
discharge
20
0~40
O
(32~104 F)
2.40~2.50
-4
0.3
16
6
5
4
Life expectancy(year)
Constant
voltage &
Constant
current
charging
(with current
restrication)
15
Charge time (hr)
Charging Procedure
For standby
power Source
10
30
Discharge time
Charging
method
5
Hr
Min
Application
vo lu m e
Charging voltage :
2.275V/cell
3
2
1
10
O
0.5
O
*Temperature compensation of charging voltage is not needed, when using the batteries within 5 C to 35 C range.
20
68
30
86
50 oC
122 oF
40
104
Battery temperature
OUTER DIMENSIONS
TERMINAL TYPE
mm(inch)
Constant power discharge characteristics at 25 oC/77 oF
Discharge time
Terminal T1
4.75(0.187)
Final Voltage
15Min
30Min
1Hr
3Hr
5Hr
10Hr
20Hr
0.8(0.03)
10.80V
43.4
31.9
25.6
15.2
8.73
3.50
2.41
1.35
0.70
10.50V
50.2
34.6
26.8
15.8
9.00
3.57
2.45
1.37
0.72
10.20V
53.4
35.8
27.6
16.2
9.16
3.60
2.46
1.37
0.72
9.90V
55.8
36.7
28.2
16.4
9.27
3.63
2.47
1.38
0.73
9.60V
57.6
37.4
28.8
16.6
9.36
3.65
2.48
1.38
0.73
45 1.5(1.77 0.06)
TERMINAL
POSITION
53 1. 5( 2. 09 0.. 06)
59 2( 2. 32 0. 08)
97 1.5(3.82 0.06)
10Min
Battery output power(W)
3.2(0.13)
6.35(0.25)
5Min
UL
R
MH19884
B.B. BATTERY CO., LTD.
Web Site: http://www.bb-battery.com
USA :
B&B BATTERY (USA) INC.
6415 RANDOLPH ST. COMMERCE,
CA, 90040 U.S.A.
TEL: 1-323-278-1900 . 1-800-278-8599
FAX: 1-323-278-1268
CHINA FACTORY:
CHENG DONG TRIAL AREA, HUANG GANG,
RAOPING GUANG DONG, CHINA, 515700
TEL: 86-768-7601001-2
FAX: 86-768-7601469
UK:
JAPAN:
B & B BATTERY (UK) CO., LTD.
TEL: 44-161-339-9458
FAX: 44-161-343-7030
B & B BATTERY(JAPAN) CO., LTD.
TEL: 81-426-256-537
FAX: 81-426-256-537
HONG KONG:
TAIWAN:
NATIONAL TRADING LTD.
B & B BATTERY CO., LTD.
TEL: 852-2301-3800
FAX: 852-2739-1182
TEL: 886-6-5898081~3
FAX: 886-6-5898087
QUALITY ASSURED
FIRM
NATIONAL
ACCREDITATION
OF CERTIFICATION
BODIES
I
S
O
1
4
0
0
1
UKAS
ENVIRONMENTAL
MANAGEMENT
Reg. No. 059-C