Product features of OSRAM ECGs in combination with central battery systems Manufacturer: Type / Description: OSRAM GmbH 81536 München Criteria: Operating voltage range DC: ECG product family: QUICKTRONIC PROFESSIONAL QTP-DL CEAG-Data 186 V - 275 V at -10 °C Description Fulfilled Battery voltage range in operation with emergency current YES Typical switching time of CEAG devices YES YES Switching time: from AC to DC from DC to AC Switching time of device: 180 ms - 450 ms 180 ms - 450 ms In accordance with standard1): DIN EN 60929 Electronic ballasts for fluorescent tube lamps, operating on alternating current 1) In accordance with standard : DIN EN 61347-2-3 (incl. annex J) Specific requirements for electronic ballasts for fluorescent lamps operated on alternating current In accordance with standard1): DIN EN 61000-3-2 1) In accordance with standard : DIN EN 61547 1) In accordance with standard : DIN EN 55015 (Measurement on AC and DC) 1) Designation after VDE 0108 is insignificant due to it not being an ECG standard 2) Tests not yet completed for annex J Features: No-load current of ECG in DCoperation ( without or with a faulty illuminant ) Max. inrush current per ECG in AC-operation: CEAG-Data: EMC standard for electromagentic compatibility (harmonic content) EMC standard for electromagnetic interference, especially for emergency lighting (immunity) EMC standard for critical values and measuring methods for radio shielding of electrical illumination appliances (interference) Explanation: 2) YES YES YES YES Manufacturer's statement: Nominal value of operation: 2L-CG-S: <10 mA / <28 mA 2L-CG (4-120 W): <10 mA 2L-CG (7-120 W): <25 mA 2L-CG (11-120 W): <41 mA Options for luminaire/EVG-monitoring units, CEAG-type: 2L-CG, according to catalog Maximum inrush current: SKU 4 x 1A (CG) => 60 A/ms per circuit SKU 2 x 3A (CG) => 120 A/ms per circuit SKU 1 x 6A (CG) => 180 A/ms SKU 2 x 3A CG-S => 250 A/ms per circuit SKU 1 x 6A CG-S => 250 A/ms Refers to a max. allowable inrush current of ECG within an electric circuit to consider the maximum contact load of the electric circuits' change-overs. see register "Overview" < 10 mA Nominal current in AC-operation: manufacturer-specific For ascertainment of max. quantity of ECG per electric circuit see register "Overview" Nominal current in DC-operation: manufacturer-specific dito see register "Overview" Luminous flux in DC-operation 186 V in relation to 230 V manufacturer-specific ECG for emergency lighting on battery operation - for planning > 75 % The OSRAM ECGs mentioned above fullfill the requirements from the DIN-EN standards on this page. Explicit approval was carried out on those standards mentioned in the identification. OSRAM as a manufacturer of electronic control gear is not liable for the faultless function of other components for emergency lighting. Luminaires for the operation as safety lighting must comply with norm DIN EN 60598-2-22. CEAG requirements overview Manufacturer: Type / Description: OSRAM GmbH 81536 München ECG product family: QUICKTRONIC PROFESSIONAL QTP-DL Max. inrush current per ECG in AC operation Nominal current in ACoperation: Nominal current in DCoperation: ECG type Switching time QTP-DL 1x18-24 automatic restart independent of the duration of the power failure, ignition 1 s after supplied with input voltage Ip = 13 A; TH = 320 µs DL/DF 18 W: 0.085 A DL/DF 24 W 0.115 A DL/DF 18 W: 0.085 A DL/DF 24 W 0.115 A QTP-DL 1x36-40 automatic restart independent of the duration of the power failure, ignition 1 s after supplied with input voltage Ip = 13 A; TH = 320 µs DL/DF 36 W: 0.17 A DL/DF 40 W 0.21 A DL/DF 36 W: 0.17 A DL/DF 40 W 0.21 A QTP-DL 1x55 GII acc. to CEAG requirements Ip = 24 A; TH = 230 µs DL 55 W: 0.26 A DL 55 W: 0.26 A QTP-DL 2x18-24 automatic restart independent of the duration of the power failure, ignition 1 s after supplied with input voltage Ip = 13 A; TH = 320 µs DL/DF 18 W: 0.16 A DL/DF 24 W 0.22 A DL/DF 18 W: 0.16 A DL/DF 24 W 0.22 A QTP-DL 2x36-40 automatic restart independent of the duration of the power failure, ignition 1 s after supplied with input voltage Ip = 23 A; TH = 250 µs DL/DF 36 W: 0.33 A DL/DF 40 W 0.41 A DL/DF 36 W: 0.33 A DL/DF 40 W 0.41 A QTP-DL 2x55 GII acc. to CEAG requirements Ip = 28 A; TH = 230 µs DL 55 W: 0.51 A DL 55 W: 0.51 A