EATON (CEAG) - Conformity Declarations with Central Battery Systems OTi DALI (05/16)

EATON – Conformity certificate with central battery systems
1. OTi DALI Linear SELV
1.1 OTi DALI 35 /220-240/700 LT2 L
1.2 OTI DALI 50/220-240/1A4 LT2 L
1.3 OTI DALI 80/220-240/1A6 LT2 L
1.4 OTI DALI 80/220-240/2A1 LT2 L
2. OTi DALI Linear non isolated
2.1 OTi DALI 60/220-240/550 D LT2 L
2.2 OTi DALI 90/220-240/1A0 LT2 L
3. OTi DALI Compact SELV
3.1 OTi DALI 15/220-240/1A0 LT2
3.2 OTi DALI 25/220-240/700 LT2
3.3 OTi DALI 35/220-240/1A0 LT2
3.4 OTI DALI 50/220-240/1A4 LT2 FAN
(VII/2015)
Requirements for dimmable DALI control gears for fluorescent lamps and LED
Manufacturer:
OSRAM GmbH
Marcel-Breuer-Str.6
D-80807 München
Version 0
Type / description:
EVG-family: OTi DALI 35 /220-240/700 LT2 L
Features:
CEAG Data:
Comment:
Control gear suitable for a DC voltage
range:
186V - 260V DC (with lead-battery)
186V - 275V DC (with NiCD-battery)
Possible voltage range of the battery in emergency mode.
(Not for AT-S + Systems required. )
Yes
Control gear compatible with the switchover time of the system?
Switch-over time:
180 ms - 450 ms
typical switch-over time of CEAG systems between mains
supply and emergency power supply
Yes
Starting behavior of the control gear:
Necessary for an individual monitoring.
Stable current consumption after less than
∆ I < 12,5 mA per luminaire, with max. 20 luminaires per
1.6 sec.
circuit: ∆ I Sum < 250 mA
Compies: (yes /no)
Yes
only for fluorescent lamps:
DIN EN 60929
Control gear complies with the standard:
AC and/or DC-supplied electronic control gear for tubular
fluorescent lamps - Performance requirements
Not relevant
only for fluorescent lamps:
DIN EN 61347-2-3 (inkl. Anhang J)
Control gear complies with the standard:
Particular requirements for AC and/or DC supplied
electronic control gear for fluorescent lamps
Not relevant
only for LED:
DIN EN 62384
Control gear complies with the standard:
DC or AC supplied electronic control gear for LED modules Performance requirements
Yes
only for LED:
DIN EN 61347-2-13
Control gear complies with the standard:
Particular requirements for DC or AC supplied electronic
control gears for LED
Yes
limits and methods of measurement of radio disturbance
characteristics of electrical lighting and similar equipment
Yes
Control gear complies with the standard:
DIN EN 55015
(Measurement on AC and DC)
Control gear complies with the standard: DIN EN 61000-3-2
Electromagnetic compatibility (EMC) - Part 3-2:
Limits - Limits for harmonic current emissions
(equipment input current ≤ 16 A per phase)
Control gear complies with the standard: DIN EN 61547
Equipment for general lighting purposes - EMC immunity
requirements
Control gear complies with DALI standardsDIN EN 62386-101 /-102 / -207**
Control gear must have the DALI Logo
Yes
VDE 0108 is not a standard for ECG, marking is not applicable
Manufacturer`s
instructions:
Features:
CEAG-Data:
Comment:
Important for function test!
According to IEC 62386 Part 102
Support of:
DALI command 145
(Query Control Gear)
DALI command 146
(Query Lamp Failure)
According to IEC 62386 Part 102
To detect a lamp failure, the
V-CG-SB.1 module send DALI Command queries (145/146)
to the DALI ECG.
DC light output settings on
V-CG-SB.1 only active if control gear is
unlocked!
In case of locked DC light output level, the DC level of
V-CG-SB.1 is not active
Important for DC light output:
Behavior in DC operation:
- Unlocked DC light output level
- Locked DC light output level
Important for lighting design:
If locked DC light output the lightout level
in % is required
Important for the contact load SKU:
Max.inrush current each
converter/luminaire in AC-operation:
Important for lighting design:
Luminous flux ratio:
DC-operation at 186 V in comparison
to 230 V AC-operation
No control of light output level from V-CG- Fixed light output level on DALI LED driver in case of a
locked DC light output level.
SB.1 in DC operation possible!
Max. permitted inrush current per circuit:
SKU 2 x 3A (CG) => 120 A
SKU 1 x 6A (CG) => 180 A
SKU 4 x 1,5A CG-S => 60 A
Describes the max. inrush current of all ballasts in a circuit,
to calculate the maimum contact rating of the circuit.
SKU 2 x 3A CG-S => 250 A
SKU 1 x 6A CG-S => 250 A
SOU CG-S // S+ => 250 A
SU S+ => 250 A
-
Light output in battery operation of the ballast, for the light
calculation.
Ja
locked DC [ ]
unlocked DC [ x ]
15% on DC,
value unlocked
See OTi DALI 35 L Overview
15%
Luminaires, which are used for emergency lighting, must be according to the standard DIN EN 60598-2-22 (particular requirements - Luminaires for emergency lighting)
**Control of V-CG-SB.1 to the DALI LEDdriver is 100% done via DALI-commands according to IEC 62386-101 /-102, so the DALI LED driver must sign with the DALI logo.
max. 1 DALI-Driver to wire with V-CG-SB.1
Stand: 20.Okt.2014
CEAG_Anforderungen an Betriebsgeräte_OTi DALI_35_220-240_700 LT2L
Hersteller:
OSRAM GmbH
Marcel-Breuer-Str.6
D-80807 München
Typ / Bezeichnung:
EVG-Typ: OTi DALI 35 /220-240/700 LT2 L
ECG type
Max. inrush current for
ECG AC-operation
Values for load
range
IN
in AC-operation
(220-240 C)
IN
in DC-operation
(176-276 V)
INoLoad
in AC-operation
INoLoad
in DC-operation
OTi DALI 35/220-240/700 LT2 L
Ip = 32A; TH =
100 μs
Maximum load
[Iout 700mA]
Minimum load
[Iout 200mA]
180 mA
(240V)
40mA
(240V)
21 mA [ 220VAC ]
20 mA [ 240VAC ]
22 mA [ 176VDC ]
20 mA [ 240VDC ]
19 mA [ 276VDC ]
CEAG_Anforderungen an Betriebsgeräte_OTi DALI_35_220-240_700 LT2L
Requirements for dimmable DALI control gears for fluorescent lamps and LED
Version 0
Manufacturer:
Type / description:
OSRAM GmbH
Marcel-Breuer-Straße 6
80807 München
Features
ECG-family: OTI DALI 50/220-240/1A4 LT2 L
CEAG data:
Comment
Operating voltage range DC:
DC: 186 V - 275 V at -10 °C
Possible voltage range of the battery in emergency mode (Not
necessary for AT-S+ System)
YES
Switching time:
from AC to DC
from DC to AC
Installation switching times:
180 ms - 450 ms
180 ms - 450 ms
Typical switch over time of CEAG CPS/LPS-devices
YES
starting charakteristic controlgear:
Stable current consumption
lower after 1,6 s
necessary for selective control
∆ I < 12,5 mA per luminaire, at max. 20 luminaires for one
current circuit: ∆ I in summ < 250 mA
YES
Fullfilled the standard*:
DIN EN 62384
DC. Or AC supplied electronic control gear for LED modules Performance requirements
YES
Fullfilled the standard*:
DIN EN 61347-2-13
Fullfilled the standard*:
DIN EN 55015
(Measurement on AC And DC)
Fullfilled the standard*:
DIN EN 61000-3-2
Fullfilled the standard*:
DIN EN 61000-3-2, Pkt. 7.3 a.)
Fullfilled the standard*:
DIN EN 61547
LED module fullfilles the standard:
DIN EN 62031
Compies
Lamp controlgear — Part 2‑13: Particular requirements for
d. c. or a. c. supplied electronic controlgear for LED modules
YES
Limits and methods of measurement of radio disturbance
characteristics of electrical lighting and similar equipment
Electromagnetic compatibility (EMC) — Part 3-2: Limits —
Limits for harmonic current emissions (equipment input current
≤ 16 A per phase)
YES
is forceful necessary for AT-S+ Systems special for LED
drivers!! (sinusoidal current draw)
Equipment for general lighting purposes — EMC immunity
requirements
YES
YES
YES
LED modules for general lighting — Safety specifications
N/A
*VDE 0108 is not a standard for ECG, marking is not applicable
Manufacturer's
instructions:
Features
CEAG-Data:
Comment:
No load current of the ballast (without
tube or with defect tube) in DCoperation
V-CG-S2: >9,4 mA oder >12,7 mA = OK
V-CG-S: >16 mA oder >47 mA = OK
V-CG-SE: >16 mA oder >47 mA = OK
V-CG-SUW:
>47 mA = OK
CG-K:
>16 mA oder >47 mA
= OK
selection aid for monitoring modules also for identification of
the max. luminaire quantity per circuit and the required battery
capacity.
these values are not allowed to be failed below def. limits for
the voltagerange of:
186 - 275V DC und 189 - 264 V AC
(for AT-S+ Systems must be the current draw sinusoidal
See DIN EN 61000-3-2, clause 7.3 a.)
see "OTi DALI 50 1A4 LT2
L"
selection aid for monitoring modules:
these values are not allowed to exceed the def. limits for the
voltagerange of:
186 - 275V DC und 189 - 264 V AC
(for AT-S+ Systems must be the current draw sinusoidal
(See DIN EN 61000-3-2, clause 7.3 a.)
see "OTi DALI 50 1A4 LT2
L"
Describes the max. inrush current of all ballasts in a circuit, to
calculate the maximum contact rating of the circuit.
see "OTi DALI 50 1A4 LT2
L"
V-CG-S2: <5,8 mA oder <7,9 mA
voltage dependent = No load current of the V-CG-S: <10 mA oder <28 mA
ballast (without or with defect LED
V-CG-SK: <10 mA oder <28 mA
module) in DC and AC - operation*:
V-CG-SUW:
<28 mA
CG-K:
<10 mA oder <28 mA
Max. inrush current each
converter/luminaire in
AC-operation:
Lightoutput in
DC-operation at 186 V in comparison to
230 V AC operation
= n.OK
= n.OK
= n.OK
= n.OK
= n.OK
Max. permitted inrush current per circuit:
SKU 2 x 3A (CG) => 120 A
SKU 1 x 6A (CG) => 180 A
SKU 4 x 1,5A CG-S => 60 A
SKU 2 x 3A CG-S => 250 A
SKU 1 x 6A CG-S => 250 A
=> 250 A
SOU CG-S // S+
=> 250 A
SU S+
-
In battery opertion of the ballast, for the light calculation
luminaires, which are used for emergency lighting, must be according to the standard DIN EN 60598-2-22 (particular requirements - Luminaires for emergency lighting) and DIN
EN 62471 classification group 1 (Photobiological safety for lamps and lamp systems)
Funktionsüberwachung erfolgt DALI-Seitig über den DALI-Treiber
Control of function is done via DALI-Driver
Max. 1 DALI- Driver OTI DALI 50 L to wire with 1 V-CG-SB.1
PFC inside OTi DALI 50 L
prep. Sniegon 07-2012 (7.2.2013)
CEAG_requirements OTi DALI 50 1A4 LT2 L
Manufacturer:
Type / Description:
OSRAM GmbH
Marcel-Breuer-Straße 6
80807 München
ECG type
OTi DALI 50/220-240/1A4 LT2 L
ECG-family: OTI DALI 50/220-240/1A4 LT2 L
Max. inrush current for
ECG AC-operation
Lamp type
IN
in AC-operation
IN
in DC-operation
INoLoad
in AC-operation
INoLoad
in DC-operation
53 A pk, th = 200 μs
Maximum load
Minimum load
[Iout 600mA]
164mA
83mA
(240V)
154mA
71mA
(240V)
36 mA [ 220VAC ]
36 mA [ 240VAC ]
12 mA [ 176VDC ]
8 mA [ 240VDC ]
7 mA [ 276VDC ]
53 A pk, th = 200 μs
Maximum load
Minimum load
[Iout 1400mA]
262mA
158mA
(240V)
252mA
147mA
(240V)
36 mA [ 220VAC ]
36 mA [ 240VAC ]
12 mA [ 176VDC ]
8 mA [ 240VDC ]
7 mA [ 276VDC ]
CEAG_requirements OTi DALI 50 1A4 LT2 L
Requirements for dimmable DALI control gears for fluorescent lamps and LED
Version 0
Manufacturer:
Type / description:
OSRAM GmbH
Marcel-Breuer-Straße 6
80807 München
Specifications
ECG-family: OTI DALI 80/220-240/2A1 LT2 L
CEAG data:
Explanation
Operating voltage range DC:
DC: 186 V - 275 V at -10 °C
Possible voltage range of the battery in emergency mode (Not
necessary for AT-S+ System)
YES
Switching time:
from AC to DC
from DC to AC
Installation switching times:
180 ms - 450 ms
180 ms - 450 ms
Typical switch over time of CEAG CPS/LPS-devices
YES
starting characteristic controlgear:
Stable current consumption
lower after 1,6 s
necessary for selective control
∆ I < 12,5 mA per luminaire, at max. 20 luminaires for one
current circuit: ∆ I in summ < 250 mA
YES
Fullfilled the standard*:
DIN EN 62384
DC. Or AC supplied electronic control gear for LED modules Performance requirements
YES
Fullfilled the standard*:
DIN EN 61347-2-13
Fullfilled the standard*:
DIN EN 55015
(Measurement on AC And DC)
Fullfilled the standard*:
DIN EN 61000-3-2
Fullfilled the standard*:
DIN EN 61000-3-2, Pkt. 7.3 a.)
Fullfilled the standard*:
DIN EN 61547
LED module fullfilles the standard:
DIN EN 62031
Fullfilled (YES/NO)
Lamp controlgear — Part 2‑13: Particular requirements for d. c.
or a. c. supplied electronic controlgear for LED modules
YES
Limits and methods of measurement of radio disturbance
characteristics of electrical lighting and similar equipment
Electromagnetic compatibility (EMC) — Part 3-2: Limits — Limits
for harmonic current emissions (equipment input current ≤ 16 A
per phase)
YES
YES
is forceful necessary for AT-S+ Systems special for LED
drivers!! (sinusoidal current draw)
YES
Equipment for general lighting purposes — EMC immunity
requirements
YES
LED modules for general lighting — Safety specifications
N/A
*VDE 0108 is not a standard for ECG, marking is not applicable
Features
No load current of the ballast (without
tube or with defect tube) in DCoperation
Comment:
V-CG-SB.1
selection aid for monitoring modules also for identification of the
max. luminaire quantity per circuit and the required battery
capacity.
these values are not allowed to be failed below def. limits for the
voltagerange of:
186 - 275V DC und 189 - 264 V AC
(for AT-S+ Systems must be the current draw sinusoidal
See DIN EN 61000-3-2, clause 7.3 a.)
see "OTi DALI 80 2A1 LT2"
selection aid for monitoring modules:
these values are not allowed to exceed the def. limits for the
voltagerange of:
186 - 275V DC und 189 - 264 V AC
(for AT-S+ Systems must be the current draw sinusoidal
(See DIN EN 61000-3-2, clause 7.3 a.)
see "OTi DALI 80 2A1 LT2"
Describes the max. inrush current of all ballasts in a circuit, to
calculate the maximum contact rating of the circuit.
see "OTi DALI 80 2A1 LT2"
voltage dependent = No load current of the
ballast (without or with defect LED
V-CG-SB.1
module) in DC and AC - operation*:
Max. inrush current each
converter/luminaire in
AC-operation:
Manufacturer's
instructions:
CEAG-Data:
Max. permitted inrush current per circuit:
SKU 2 x 3A (CG) => 120 A
SKU 1 x 6A (CG) => 180 A
SKU 4 x 1,5A CG-S => 60 A
SKU 2 x 3A CG-S => 250 A
SKU 1 x 6A CG-S => 250 A
SOU CG-S // S+
=> 250 A
SU S+
=> 250 A
Lightoutput in
DC-operation at 186 V in comparison to
230 V AC operation
-
In battery opertion of the ballast, for the light calculation
luminaires, which are used for emergency lighting, must be according to the standard DIN EN 60598-2-22 (particular requirements - Luminaires for emergency
lighting) and DIN EN 62471 classification group 1 (Photobiological safety for lamps and lamp systems)
Funktionsüberwachung erfolgt DALI-Seitig über den DALI-Treiber
Control of function is done via DALI-Driver
Max. 1 DALI- Driver OTI DALI 50 L to wire with 1 V-CG-SB.1
PFC inside OTi DALI 50 L
prep. Sniegon 07-2012 (7.2.2013)
Manufacturer:
OSRAM GmbH
Marcel-Breuer-Straße 6
80807 München
ECG type
OTI DALI 80/220-240/2A1 LT2 L
Type / Description:
ECG-family: OTI DALI 80/220-240/2A1 LT2 L
Max. inrush current for
ECG AC-operation
Lamp type
IN
in AC-operation
IN
in DC-operation
INoLoad
in AC-operation
INoLoad
in DC-operation
I max = 53 A Th = 200 μs
Maximum load
Minimum load
[Iout 1000mA]
261mA
119mA
(240V)
248mA
105mA
(240V)
43 mA [ 220VAC ]
43 mA [ 240VAC ]
13 mA [ 176VDC ]
9 mA [ 240VDC ]
8 mA [ 276VDC ]
I max = 53 A Th = 200 μs
Maximum load
Minimum load
[Iout 2100mA]
393mA
225mA
(240V)
381mA
214mA
(240V)
43 mA [ 220VAC ]
43 mA [ 240VAC ]
13 mA [ 176VDC ]
9 mA [ 240VDC ]
8 mA [ 276VDC ]
CEAG_requirements OTi DALI 80 2A1 LT2
Requirements for dimmable DALI control gears for fluorescent lamps and LED
Version 0
Manufacturer:
Type / description:
OSRAM GmbH
Marcel-Breuer-Straße 6
80807 München
Specifications
ECG-family: OTI DALI 80/220-240/1A6 LT2 L
CEAG data:
Explanation
Operating voltage range DC:
DC: 186 V - 275 V at -10 °C
Possible voltage range of the battery in emergency mode (Not
necessary for AT-S+ System)
YES
Switching time:
from AC to DC
from DC to AC
Installation switching times:
180 ms - 450 ms
180 ms - 450 ms
Typical switch over time of CEAG CPS/LPS-devices
YES
starting characteristic controlgear:
Stable current consumption
lower after 1,6 s
necessary for selective control
∆ I < 12,5 mA per luminaire, at max. 20 luminaires for one current
circuit: ∆ I in summ < 250 mA
YES
Fullfilled the standard*:
DIN EN 62384
DC. Or AC supplied electronic control gear for LED modules Performance requirements
YES
Fullfilled the standard*:
DIN EN 61347-2-13
Fullfilled the standard*:
DIN EN 55015
(Measurement on AC And DC)
Fullfilled the standard*:
DIN EN 61000-3-2
Fullfilled the standard*:
DIN EN 61000-3-2, Pkt. 7.3 a.)
Fullfilled the standard*:
DIN EN 61547
LED module fullfilles the standard:
DIN EN 62031
Fullfilled (YES/NO)
Lamp controlgear — Part 2‑13: Particular requirements for d. c. or a. c.
supplied electronic controlgear for LED modules
YES
Limits and methods of measurement of radio disturbance
characteristics of electrical lighting and similar equipment
YES
Electromagnetic compatibility (EMC) — Part 3-2: Limits — Limits for
harmonic current emissions (equipment input current ≤ 16 A per phase)
YES
is forceful necessary for AT-S+ Systems special for LED drivers!!
(sinusoidal current draw)
Equipment for general lighting purposes — EMC immunity
requirements
YES
YES
LED modules for general lighting — Safety specifications
N/A
*VDE 0108 is not a standard for ECG, marking is not applicable
Features
CEAG-Data:
Manufacturer's
instructions:
Comment:
No load current of the ballast (without tube
V-CG-SB.1
or with defect tube) in DC-operation
selection aid for monitoring modules also for identification of the max.
luminaire quantity per circuit and the required battery capacity.
these values are not allowed to be failed below def. limits for the
voltagerange of:
186 - 275V DC und 189 - 264 V AC
(for AT-S+ Systems must be the current draw sinusoidal See DIN
EN 61000-3-2, clause 7.3 a.)
see "OTi DALI 80 1A6 LT2 L"
voltage dependent = No load current of the
ballast (without or with defect LED
V-CG-SB.1
module) in DC and AC - operation*:
selection aid for monitoring modules:
these values are not allowed to exceed the def. limits for the
voltagerange of:
186 - 275V DC und 189 - 264 V AC
(for AT-S+ Systems must be the current draw sinusoidal (See DIN
EN 61000-3-2, clause 7.3 a.)
see "OTi DALI 80 1A6 LT2 L"
Describes the max. inrush current of all ballasts in a circuit, to calculate
the maximum contact rating of the circuit.
see "OTi DALI 80 1A6 LT2 L"
Max. inrush current each
converter/luminaire in
AC-operation:
Max. permitted inrush current per circuit:
SKU 2 x 3A (CG) => 120 A
SKU 1 x 6A (CG) => 180 A
SKU 4 x 1,5A CG-S => 60 A
SKU 2 x 3A CG-S => 250 A
SKU 1 x 6A CG-S => 250 A
SOU CG-S // S+ => 250 A
SU S+ => 250 A
Lightoutput in
DC-operation at 186 V in comparison to 230
V AC operation
-
In battery opertion of the ballast, for the light calculation
luminaires, which are used for emergency lighting, must be according to the standard DIN EN 60598-2-22 (particular requirements - Luminaires for emergency lighting) and DIN EN 62471
classification group 1 (Photobiological safety for lamps and lamp systems)
Funktionsüberwachung erfolgt DALI-Seitig über den DALI-Treiber
Control of function is done via DALI-Driver
Max. 1 DALI- Driver OTI DALI 80 L to wire with 1 V-CG-SB.1
PFC inside OTi DALI 80 L
Sniegon 05-2014
CEAG_requirements OTi DALI 80 1A6 LT2 L
Manufacturer:
OSRAM GmbH
Marcel-Breuer-Straße 6
80807 München
ECG type
OTi DALI 80/220-240/1A6 LT2 L
Type / Description:
ECG-family: OTI DALI 80/220-240/1A6 LT2 L
Max. inrush current for
ECG AC-operation
Lamp type
IN
in AC-operation
IN
in DC-operation
INoLoad
in AC-operation
INoLoad
in DC-operation
I max = 53 A Th = 200 μs
Maximum load
Minimum load
[Iout 600mA]
168mA
87mA
(240V)
155mA
67mA
(240V)
42 mA [ 220VAC ]
43 mA [ 240VAC ]
12 mA [ 176VDC ]
8 mA [ 240VDC ]
7 mA [ 276VDC ]
I max = 53 A Th = 200 μs
Maximum load
Minimum load
[Iout 1550mA]
380mA
180mA
(240V)
367mA
167mA
(240V)
42 mA [ 220VAC ]
43 mA [ 240VAC ]
12 mA [ 176VDC ]
8 mA [ 240VDC ]
7 mA [ 276VDC ]
CEAG_requirements OTi DALI 80 1A6 LT2 L
Requirements for dimmable DALI control gears for fluorescent lamps and LED
Type / Description: Constant current LED controlgear
Hersteller:
OSRAM GmbH
Marcel-Breuer-Str.6
D-80807 München
Specifications:
Version 0
LED controlgear: OTi DALI 60/220-240/550 D LT2 L
LED controlgear: OTi DALI 90/220-240/1A0 D LT2 L
CEAG Data
Explanation:
Fulfilled: (Yes / No)
Control gear suitable for
a DC voltage range:
186V - 275V DC
Possible voltage range of the battery in emergency mode.
(Not for AT-S + Systems required )
Yes
Control gear compatible with the
switch-over time of the system?
Switch-over time:
180 ms - 450 ms
Typical switch-over time of CEAG systems between
mains supply and emergency power supply
Yes
Starting behavior of the control gear:
Stable current consumption
after less than 1.6 sec. maximum.
Necessary for an individual monitoring.
Δ I < 12,5 mA per luminaire, with max. 20 luminaires per
circuit Δ I sum < 250 mA
Yes
Control gear complies with
the standard:
DIN EN 62384
AC or DC supplied electronic control gear for LED modules Performance requirements
Yes
Control gear complies with
the standard:
DIN EN 61347-2-13 (incl. Attachment J)
Particular requirements for AC or DC supplied
electronic control gear for LED modules
Yes
Control gear complies with
the standard:
DIN EN 55015
(Measured in AC and DC)
Limits and methods of measurement of radio disturbance
characteristics of electrical lighting and similar equipment
Yes
Control gear complies with
the standard:
DIN EN 61000-3-2
Control gear complies with
the standard:
DIN EN 61000-3-2, Pkt. 7.3 a.)
Control gear complies with
the standard:
DIN EN 61547
Equipment for general lighting purposes EMC immunity requirements
Yes
LED moduel complies with
the standard:
DIN EN 62031
LED modules for general lighting Safety specifications
N/A
Electromagnetic compatibility (EMC) Part 3-2: Limits - Limits for harmonic current emissions
(equipment input current ≤ 16 A per phase)
Mandatory for control gears for LED modules in
combination with AT-S+ Systems! (Current consumption
must be sinusoidal.)
Yes
Yes
The labeling "according to VDE 0108" is not meaningful, because this is not a control gear standard!
Merkmale:
Voltage-dependent
Input current of the control gear
incl. LED
in DC and AC operation:
Voltage-dependent
No-load current of the control gear
(without or defect LED module)
in DC and AC - operation*:
CEAG-Daten:
Erklärung:
Angabe Hersteller:
V-CG-SB.1 with DALI
lamp failure query
Selection guide for the monitoring modules as well as for the
calculation of the max. number of luminaires per circuit and
the necessary battery capacity.
In the voltage range of 186 - 275V DC and 189 - 264V AC
the
input current must be higher.
The current consumption must be sinusoidal for AT-S+
Systems. See DIN EN 61000-3-2, Pkt. 7.3 a.)
AC:
see attachment
converter overview list
DC:
V-CG-SB.1 with DALI
lamp failure query
Selection guide for the monitoring modules.
In the voltage range of 186 - 275V DC and 189 - 264V AC
the
no-load current must be lower.
The current consumption must be sinusoidal for AT-S+
Systems. See DIN EN 61000-3-2, Pkt. 7.3 a.)
AC:
see attachment
converter overview list
DC:
Max. permitted inrush current
per circuit:
SKU 2 x 3A (CG) => 120 A
SKU 1 x 6A (CG) => 180 A
Describes the max. inrush current of all luminaires in one
IPK = 25A
Max. inrush current of each luminaire SKU 4 x 1,5A CG-S => 60 A
circuit to calculate the maximum contact load of the circuit
in AC operation
tHW = 240μs
SKU 2 x 3A CG-S => 250 A
SKU 1 x 6A CG-S => 250 A
=> 250 A
SOU CG-S // S+
SU S+
=> 250 A
Luminous flux ratio:
Light output in battery operation is needed for the light
see attachment
186 V DC operation in comparison to
calculation.
converter overview list
230 V AC operation
Luminaires for emergency lighting must comply with DIN EN 60598-2-22 (Particular requirements -Luminaires for emergency lighting) and
DIN EN 62471 classification group 1 (Photobiological safety of lamps and lamp systems).
*The modules of the V-CG-S series monitor the current consumption on the primary side of the control gear for LED modules within the specified limits. Failures of
individual LEDs (low-impedance) on the secondary side do not inevitably lead to a modification of current consumption on the primary side, and in such cases
cannot be detected as a failure.
PFC inside; One OTi DALI- Driver to wire with one V-CG-SB.1; OTi DALI 90 Version AA67888
Stand: 01.07.2012
CEAG_Anforderungen an Betriebsgeräte_OTi DALI 60_90
Hersteller:
OSRAM GmbH
Marcel-Breuer-Str.6
D-80807 München
ECG type
Typ / Bezeichnung:
LED controlgear: OTi DALI 60/220-240/550 D LT2 L
LED controlgear: OTi DALI 90/220-240/1A0 D LT2 L
Max. inrush current for
ECG AC-operation
Values for load range
IN
in AC-operation
IN
in DC-operation
27 mA
132 mA
Maximum load
30 mA
59 mA
Minimum load
(240V)
(230V)
[Iout 120mA]
Maximum load
262 mA
43 mA
Minimum load
98 mA
30 mA
[Iout 280mA]
(230V)
(240V)
Maximum load
277 mA
48 mA
Minimum load
154 mA
30 mA
[Iout 550mA]
(230V)
(240V)
Maximum load
299 mA
42 mA
OTi DALI 90/220-240/1A0 D LT2 L
IPK = 25 A; tHW = 240 μs
Minimum load
96 mA
16 mA
[Iout 280mA]
(230V)
(240V)
Maximum load
393 mA
66 mA
Minimum load
166 mA
33 mA
[Iout 600 mA]
(230V)
(240V)
Maximum load
402 mA
66 mA
Minimum load
271 mA
48 mA
[Iout 1000 mA]
(230V)
(240V)
Note: When this ECG is operating at DC the output current is reduced to 15% by factory setup. Then IOUT ratio is approx. 15%
Note: Light levels are only under control of the V-CG-SB.1 module if the DC detection is switched off.
Note: Then POUT is limited to 20 W in case of Ta < T <= 70°C
Note: For safety luminaires acc. IEC 60598-2-22 POUT shall be limited to 40 W in order to fulfill the requirements
Note: OTi DALI 90 Version AA67888 tested
Information in this document is subject to change without notice
OTi DALI 60/220-240/550 D LT2 L
IPK = 25 A; tHW = 240 μs
INoLoad
in AC-operation
31 mA [ 230VAC ]
31 mA [ 230VAC ]
31 mA [ 230VAC ]
31 mA [ 230VAC ]
31 mA [ 230VAC ]
31 mA [ 230VAC ]
INoLoad
in DC-operation
<10mA [176VDC]
<10mA [240VDC]
<10mA [276VDC]
<10mA [176VDC]
<10mA [240VDC]
<10mA [276VDC]
<10mA [176VDC]
<10mA [240VDC]
<10mA [276VDC]
<10mA [176VDC]
<10mA [240VDC]
<10mA [276VDC]
<10mA [176VDC]
<10mA [240VDC]
<10mA [276VDC]
<10mA [176VDC]
<10mA [240VDC]
<10mA [276VDC]
CEAG_Anforderungen an Betriebsgeräte_OTi DALI 60_90
Requirements for dimmable DALI control gears for fluorescent lamps and LED
Manufacturer:
OSRAM GmbH
Marcel - Breuer - Straße 6
D 80807 München
Features:
Version 0
Type / description:
ECG-type: OTi DALi 15/220-240/1A0 LT2
CEAG data:
Comment:
Complies: (Yes/No)
Control gear suitable for
a DC voltage range:
186V - 260V DC (for Lead-Battery)
186V - 275V DC (for NiCD-Battery)
Possible voltage range of the battery in emergency mode.
(Not for AT-S + Systems required )
Yes
Control gear compatible with the
switch-over time of the system?
Switch-over time:
180 ms - 450 ms
Typical switch-over time of CEAG systems between
mains supply and emergency power supply
Yes
Starting behavior of the control gear:
Stable current consumption
after less than 1.6 sec. maximum.
Necessary for an individual monitoring.
D I < 12,5 mA per luminaire, with max. 20 luminaires per
circuit D I sum < 250 mA
Yes
DIN EN 60929
AC and/or DC-supplied electronic control gear for tubular
fluorescent lamps - Performance requirements
not relevant
DIN EN 61347-2-3 (incl. Attachment J)
Particular requirements for AC and/or DC supplied electronic
control gear for fluorescent lamps
not relevant
DIN EN 62384
DC. Or AC supplied electronic control gear for LED modules Performance requirements
Yes
DIN EN 61347-2-13
Lamp controlgear — Part 2‑13: Particular requirements for
d. c. or a. c. supplied electronic controlgear for LED modules
Yes
Fullfilled the standard:
DIN EN 55015
(Measurement on AC And DC)
Limits and methods of measurement of radio disturbance
characteristics of electrical lighting and similar equipment
Yes
Fullfilled the standard:
DIN EN 61000-3-2
Electromagnetic compatibility (EMC) — Part 3-2: Limits —
Limits for harmonic current emissions (equipment input
current ≤ 16 A per phase)
Yes
Fullfilled the standard:
DIN EN 61547
Equipment for general lighting purposes — EMC immunity
requirements
Yes
Fullfilled the DALI standards:
DIN EN 62386-101 /-102 / -207*
Control gear must have the DALI Logo
Yes
only for flourescent lamps:
Control gear complies with the
standard:
only for flourescent lamps:
Control gear complies with the
standard:
only for LED:
Control gear complies with the
standard:
only for LED:
Control gear complies with the
standard:
Note: VDE 0108 is not a standard for ECG, marking is not applicable
Features:
Important for function test!
According to IEC 62386 Part 102
Support of :
DALI command 145
(Query Control Gear)
DALI command 146
(Query Lamp Failure)
Important for DC light output:
Behavior in DC operation:
- Unlocked DC light output level
- Locked DC light output level
Important for lighting design:
If locked DC light output the lightout
level in % is required
Important for the contact load SKU:
Max. inrush current each
converter/luminaire in
AC-operation:
Important for lighting design:
Luminous flux ratio:
DC-operation at 186 V in comparison
to 230 V AC operation
CEAG-Data:
Comment:
According to IEC 62386 Part 102
To detect a lamp failure, the V-CG-SB.1 module send
DALI command queries (145/146) to the DALI LED driver
DC light output settings on V-CG-SB.1
only active if control gear is unlocked!
In case of locked DC light output level, the DC level of
V-CG-SB.1 is not active !
Manufacturer's
instructions:
Yes
Unlocked DC [ ]
Locked DC [ X ] **)
No control of light output level from V-CGLocked light output level in %, e.g. 15%
SB.1 in DC operation possible!
15% **)
Max. permitted inrush current per circuit:
SKU 2 x 3A (CG) => 120 A
SKU 1 x 6A (CG) => 180 A
SKU 4 x 1,5A CG-S => 60 A
SKU 2 x 3A CG-S => 250 A
SKU 1 x 6A CG-S => 250 A
SOU CG-S // S+
=> 250 A
SU S+
=> 250 A
Describes the max. inrush current of all ballasts in a circuit,
to calculate the maximum contact rating of the circuit.
5A / 45µs
Light output In battery opertion of the ballast,
for the light calculation
15% **)
-
Luminaires, which are used for emergency lighting, must be according to the standard DIN EN 60598-2-22 (particular requirements - Luminaires for emergency
lighting)
*Control of V-CG-SB.1 to the DALI LED driver is 100% done via DALI-commands according to IEC 62386-101 /-102
so the DALI LED driver must sign with the DALI logo
**) The lightout level is locked in DC-operation. Factory setting is 15% of the maximum level. It is possible to change the behavior of the controlgear in DC-operation. For this
the software DALI magic is needed.
Max. 1 DALI- Driver to wire with 1 V-CG-SB.1
In use of manifold ballasts, the different lamp failure detection of the manufacturer must be consider! Some devices don`t detect a failure if one lamp is defect.
Date: 20.Oct.2014
CEAG_requirem_for_DALI_control gears, fl_lamps and LED_V0_OTi DALI 15
Requirements for dimmable DALI control gears for fluorescent lamps and LED
Version 0
Manufacturer:
Type / Description: Constant current LED controlgear
OSRAM GmbH
Marcel-Breuer-Straße 6
80807 München
LED controlgear: OTi DALI 25/220-240/700 LT2
LED controlgear: OTi DALI 35/220-240/1A0 LT2
Features
CEAG data:
Comment
Control gear suitable for
a DC voltage range:
186V - 260V DC (for Lead-Battery)
186V - 275V DC (for NiCD-Battery)
Possible voltage range of the battery in emergency mode.
(Not for AT-S + Systems required )
YES
Control gear compatible with the switchover time
of the system?
Switch-over time:
180 ms - 450 ms
Typical switch-over time of CEAG systems between
mains supply and emergency power supply
YES
Starting behavior of the control gear:
Stable current consumption
lower after 1,6 s
necessary for individual monitoring
∆ I < 12,5 mA per luminaire, at max. 20 luminaires for one current circuit: ∆ I in sum
< 250 mA
YES
DIN EN 60929
AC and/or DC-supplied electronic control gear for tubular
fluorescent lamps - Performance requirements
N/A
only for fluorescent lamps:
Control gear complies with the
standard:
only for fluorescent lamps:
Control gear complies with the
standard:
only for LED:
Control gear complies with the
standard:
only for LED:
Control gear complies with the
standard:
Compies
DIN EN 61347-2-3 (incl. Attachment J)
Particular requirements for AC and/or DC supplied electronic
control gear for fluorescent lamps
N/A
DIN EN 62384
DC. Or AC supplied electronic control gear for LED modules Performance requirements
YES
DIN EN 61347-2-13
Lamp controlgear — Part 2‑13: Particular requirements for d. c.
or a. c. supplied electronic controlgear for LED modules
YES
Fullfilled the standard:
DIN EN 55015
(Measurement on AC and DC)
Limits and methods of measurement of radio disturbance
characteristics of electrical lighting and similar equipment
Fullfilled the standard:
DIN EN 61000-3-2
Fullfilled the standard:
DIN EN 61547
Fullfilled the DALI standards:
DIN EN 62386-101 /-102 / -207*
YES
Electromagnetic compatibility (EMC) — Part 3-2: Limits —
Limits for harmonic current emissions (equipment input current
≤ 16 A per phase)
Equipment for general lighting purposes — EMC immunity requirements
YES
YES
Control gear must have the DALI Logo
YES
*VDE 0108 is not a standard for ECG, marking is not applicable
Features
CEAG-Data:
Comment:
Important for function test!
According to IEC 62386 Part 102
Support of :
DALI command 145
(Query Control Gear)
DALI command 146
(Query Lamp Failure)
According to IEC 62386 Part 102
To detect a lamp failure, the V-CG-SB.1 module send
DALI command queries (145/146) to the DALI LED driver
Important for DC light output:
Behavior in DC operation:
- Unlocked DC light output level
- Locked DC light output level
DC light output settings on V-CG-SB.1
only active if control gear is unlocked!
In case of locked DC light output level, the DC level of
V-CG-SB.1 is not active !
Important for lighting design:
If locked DC light output the lightout
level in % is required
No control of light output level from V-CGSB.
1 in DC operation possible!
Locked light output level in %, e.g. 15%
Max. permitted inrush current per circuit:
SKU 2 x 3A (CG) => 120 A
SKU 1 x 6A (CG) => 180 A
SKU 4 x 1,5A CG-S => 60 A
SKU 2 x 3A CG-S => 250 A
SKU 1 x 6A CG-S => 250 A
SOU CG-S // S+
=> 250 A
SU S*
=> 250 A
Describes the max. inrush current of all ballasts in a circuit, to
calculate the maximum contact rating of the circuit.
Important for the contact load SKU:
Max. inrush current each
converter/luminaire in
AC-operation:
Important for lighting design:
Luminous flux ratio:
DC-operation at 186 V in comparison
to 230 V AC operation
-
Light output In battery opertion of the ballast,
for the light calculation
Manufacturer's
instructions:
Yes
Unlocked DC [x]
Locked DC [ ]
15%
IPK = 10A
tHW = 100μs
15%
Luminaires, which are used for emergency lighting, must be according to the standard DIN EN 60598-2-22 (particular requirements - Luminaires for emergency lighting)
*Control of V-CG-SB.1 to the DALI LED driver is 100% done via DALI-commands according to IEC 62386-101 /-102
so the DALI LED driver must sign with the DALI logo
Max. 1 DALI- Driver to wire with 1 V-CG-SB.1
In use of manifold ballasts, the different lamp failure detection of the manufacturer must be consider! Some devices don`t detect a failure if one lamp is defect.
Date: 20.Oct.2014
CEAG_requirements OTi DALI 25_35
Manufacturer:
Type / Description: Constant current LED controlgear
OSRAM GmbH
Marcel-Breuer-Straße 6
80807 München
ECG type
OTi DALI 25/220-240/700 LT2
OTi DALI 35/220-240/1A0 LT2
LED controlgear: OTi DALI 25/220-240/700 LT2
LED controlgear: OTi DALI 35/220-240/1A0 LT2
Max. inrush current for
ECG AC-operation
Lamp type
IN
in AC-operation
IN
in DC-operation
INoLoad
in AC-operation
INoLoad
in DC-operation
IPK = 10 A; tHW = 100 μs
Maximum load
Minimum load
[Iout 180mA]
64mA
47mA
(240V)
48mA
16mA
(240V)
39 mA [ 220VAC ]
39 mA [ 240VAC ]
12 mA [ 176VDC ]
9 mA [ 240VDC ]
7 mA [ 276VDC ]
Maximum load
Minimum load
[Iout 700mA]
130mA
65mA
(240V)
123mA
49mA
(240V)
39 mA [ 220VAC ]
39 mA [ 240VAC ]
12 mA [ 176VDC ]
9 mA [ 240VDC ]
7 mA [ 276VDC ]
Maximum load
Minimum load
[Iout 350mA]
97mA
54 mA
(240V)
87mA
31 mA
(240V)
40 mA [ 220VAC ]
40 mA [ 240VAC ]
12 mA [ 176VDC ]
9 mA [ 240VDC ]
7 mA [ 276VDC ]
Maximum load
Minimum load
[Iout 1050mA]
178mA
98mA
(240V)
173mA
40 mA
(240V)
40 mA [ 220VAC ]
40 mA [ 240VAC ]
12 mA [ 176VDC ]
9 mA [ 240VDC ]
7 mA [ 276VDC ]
IPK = 10 A; tHW = 100 μs
Note: When this ECG is operating at DC the output current is reduced to 15% by default.
Note: Dimming levels are only under control of the V-CG-SB.1 module if the DC detection flag in the ECGs firmware is disabled.
Note: Then POUT is limited to 20W in case of Ta < T <= 70°C
Information in this document is subject to change without notice
CEAG_requirements OTi DALI 25_35
Requirements for dimmable DALI control gears for fluorescent lamps and LED
Version 0
Manufacturer:
Type / description:
OSRAM GmbH
Marcel-Breuer-Straße 6
80807 München
Specifications
ECG-family: OTI DALI 50/220-240/1A4 LT2 FAN
CEAG data:
Explanation
Operating voltage range DC:
DC: 186 V - 275 V at -10 °C
Possible voltage range of the battery in emergency mode (Not
necessary for AT-S+ System)
YES
Switching time:
from AC to DC
from DC to AC
Installation switching times:
180 ms - 450 ms
180 ms - 450 ms
Typical switch over time of CEAG CPS/LPS-devices
YES
starting characteristic controlgear:
Stable current consumption
lower after 1,6 s
necessary for selective control
∆ I < 12,5 mA per luminaire, at max. 20 luminaires for one current
circuit: ∆ I in summ < 250 mA
YES
Fullfilled the standard*:
DIN EN 62384
DC. Or AC supplied electronic control gear for LED modules Performance requirements
YES
Fullfilled the standard*:
DIN EN 61347-2-13
Fullfilled the standard*:
DIN EN 55015
(Measurement on AC And DC)
Fullfilled the standard*:
DIN EN 61000-3-2
Fullfilled the standard*:
DIN EN 61000-3-2, Pkt. 7.3 a.)
Fullfilled the standard*:
DIN EN 61547
LED module fullfilles the standard:
DIN EN 62031
Fullfilled (YES/NO)
Lamp controlgear — Part 2‑13: Particular requirements for d. c. or
a. c. supplied electronic controlgear for LED modules
YES
Limits and methods of measurement of radio disturbance
characteristics of electrical lighting and similar equipment
Electromagnetic compatibility (EMC) — Part 3-2: Limits — Limits for
harmonic current emissions (equipment input current ≤ 16 A per
phase)
YES
is forceful necessary for AT-S+ Systems special for LED drivers!!
(sinusoidal current draw)
Equipment for general lighting purposes — EMC immunity
requirements
YES
YES
YES
LED modules for general lighting — Safety specifications
N/A
*VDE 0108 is not a standard for ECG, marking is not applicable
Features
CEAG-Data:
Manufacturer's
instructions:
Comment:
No load current of the ballast (without
V-CG-SB.1
tube or with defect tube) in DC-operation
selection aid for monitoring modules also for identification of the max.
luminaire quantity per circuit and the required battery capacity.
these values are not allowed to be failed below def. limits for the
voltagerange of:
186 - 275V DC und 189 - 264 V AC
(for AT-S+ Systems must be the current draw sinusoidal See DIN
EN 61000-3-2, clause 7.3 a.)
see "OTi DALI 50 220-240
1A4 LT2 FAN"
voltage dependent = No load current of the
ballast (without or with defect LED
V-CG-SB.1
module) in DC and AC - operation*:
selection aid for monitoring modules:
these values are not allowed to exceed the def. limits for the
voltagerange of:
186 - 275V DC und 189 - 264 V AC
(for AT-S+ Systems must be the current draw sinusoidal (See
DIN EN 61000-3-2, clause 7.3 a.)
see "OTi DALI 50 220-240
1A4 LT2 FAN"
Describes the max. inrush current of all ballasts in a circuit, to
calculate the maximum contact rating of the circuit.
see "OTi DALI 50 220-240
1A4 LT2 FAN"
Max. inrush current each
converter/luminaire in
AC-operation:
Max. permitted inrush current per circuit:
SKU 2 x 3A (CG) => 120 A
SKU 1 x 6A (CG) => 180 A
SKU 4 x 1,5A CG-S => 60 A
SKU 2 x 3A CG-S => 250 A
SKU 1 x 6A CG-S => 250 A
=> 250 A
SOU CG-S // S+
=> 250 A
SU S+
Lightoutput in
DC-operation at 186 V in comparison to
230 V AC operation
-
In battery opertion of the ballast, for the light calculation
luminaires, which are used for emergency lighting, must be according to the standard DIN EN 60598-2-22 (particular requirements - Luminaires for emergency lighting) and DIN EN
62471 classification group 1 (Photobiological safety for lamps and lamp systems)
Control of function is done via DALI-Driver
In case of defective LED-module, the DALI- Driver OTi DALI 50 22-240 1A4 LT2 FAN has to be switched off via DALI command "0" to prevent possible disturbances of CEAGcommunication
Max. 1 DALI- Driver OTI DALI 50 L to wire with 1 V-CG-SB.1
PFC inside OTi DALI 50 L
Sniegon 07-2014
CEAG_requirements OTi DALI 50 220-240 1A4 LT2 FAN
Manufacturer:
OSRAM GmbH
Marcel-Breuer-Straße 6
80807 München
ECG type
OTi DALI 50 220-240 1A4 LT2
FAN
Type / Description:
ECG-family: OTI DALI 50/220-240/1A4 LT2 FAN
Max. inrush current for
ECG AC-operation
Lamp type
IN
in AC-operation
IN
in DC-operation
Maximum load
Minimum load
[Iout 600mA]
160mA
116 mA
(240V)
203 mA
160 mA
(240V)
Maximum load
Minimum load
[Iout 1400mA]
265 mA
126 mA
(240V)
261 mA
174mA
(240V)
Ip = 24 A; TH = 190 µs
INoLoad
in AC-operation
INoLoad
in DC-operation
39 mA [ 220VAC ]
36 mA [ 240VAC ]
10 mA [ 176VDC ]
10 mA [ 240VDC ]
9,5 mA [ 276VDC ]
CEAG_requirements OTi DALI 50 220-240 1A4 LT2 FAN