Description Function The EASY Hybrid Remote hand-held transmitter is used together with an EASY IR infrared receiver or an EASY RC radio receiver for the setting and functional control of connected EASY control units. The hand-held transmitter can be used to operate up to 8 channels, 8 lighting scenes and 4 sequences of a lighting system and to set the brightness, light colour and colour temperature. The power supply is provided via commercially available batteries. If the hand-held transmitter is mounted in a wall bracket, an external power supply can be used. EASY Hybrid Remote A Design B The hand-held transmitter is made up of the following components: • Infrared window (A) F1 F2 F3 C D F4 1 2 3 4 5 6 7 8 A B C D • Display (B) –– Infrared transmission (1) –– Radio transmission training mode is activated (2) –– Battery status display (3) –– Transmission is active (4) E –– Setup menu is activated (5) –– Radio transmission (6) –– 10-digit dot matrix display (7) G • Central button (C) • Jog wheel (D) • Scene buttons (E) • Function buttons (F1, F2, F3, F4) • Sequence buttons (G) 5 • DIP switch in battery compartment • „Connect“ button in battery compartment IR Hand-held transmitter Fitting instructions LEARN SETUP RF B J Installation Safety instructions K The wall bracket must only be installed and put into operation by a qualified electrician. The applicable safety regulations and accident prevention regulations must be observed. CAUTION! Destruction of the hand-held transmitter and other devices through incorrect mounting! • Adhere to the connection diagram. • Do not wire the EASY bus terminals with an external voltage, especially not a mains voltage of 230 V. • Only connect the supply terminals to a DC voltage of 10-24 V. • Only use batteries of the specified type. • Only work on the hand-held transmitter when it is de-energised. L Attaching the wall bracket Note: A flush-mounted box is needed for connecting the EASY bus. For the combined EASY bus and DC supply connection, a flush-mounted box with twice the depth is needed if the power supply unit is to be placed into the flush-mounted box behind the wall bracket. Attaching without a flush-mounted box Loosen the cover screws (L) on the back of the wall bracket and remove the cover. Loosen the printed circuit board screws (M). Remove the board in the lower part of the wall bracket and keep it in a safe place. M L R eattach the cover and fix it with the screws (L). Attach the mounting plate (N) on a level surface. Mount the wall bracket on the mounting plate from above. VIII 2009 EASY-Hybrid-Remote_ma0908en_we1.01.indd OSRAM GmbH Kunden Service Center Customer-Service-Center (CSC) Fix the wall bracket from below with the supplied mounting P screws (O). H and-held transmitter as a permanent wall operating unit (optional): Fix the hand-held transmitter from below with the supplied fixing screws (P). Steinerne Furt 62 86167 Augsburg Germany Tel : +49 (0) 1803 677 - 200 (kostenpflichtig / charges apply) Fax.: +49 (0) 1803 677 - 202 O N www.osram.com www.osram.de 40083214217394 4008321421739 Page 1 of 2 Installation (cont.) Connection diagram + NMounting plate on the back of the wall bracket 10-24 V DC- Q DC supply (optional) R EASY Bus connection (optional) Q Attachment on flush-mounted box and optional electrical connection Shorten the connection wires so that they protrude approx. 5-6 cm from the flush-mounted box. N Strip the required connection wires by approx. 5 mm. Insulate any connection wires not needed. R Y-Connector Screw Pass the required connection wires through the centre opening of the mounting plate (N). 4 3 2 1 4 3 2 1 + A lign the mounting plate (N) and attach it to the flush- mounted box. Ensure that it is seated securely, sliding the mounting plate up or down or to the left or right by a few millimetres if necessary. Optional: Connect and test the DC supply: CAUTION! Destruction of components connected to EASY bus! • Do not connect the DC supply to the EASY bus. Connect the supplied 2-pin plug-in connector to the DC power supply and plug it into the corresponding socket (Q) on the back of the wall bracket. L N DALI EASY III Easy Signal GND (-) CH4+ (W) CH3+ (B) CH2+ (G) CH1+ (R) Test: Take the batteries out of the hand-held transmitter and switch on the DC supply. Insert the hand-held transmitter into the wall bracket from above and press down. à The LCD lighting must light up. Switch off the DC supply. Optional: Connect the EASY bus after the DC supply test L N OT EASY 60 II Easy signal 24 V (+) CH1 (R-) CH2 (G-) CH3 (B-) CH4 (W-) GND (-) was successful. Connect the supplied 4-pin plug-in connector to the EASY bus wires and plug it into the corresponding socket (R) on the back of the wall bracket. Bend away the connecting wires in an S-shape and place the wall bracket onto the mounting frame from above. Ensure that the wires do not press against the wall bracket and are not pinched. A ttach the wall bracket using the supplied mounting screws (O). H and-held transmitter as a permanent wall operating unit (optional): Fix the hand-held transmitter from below with the supplied fixing screws (P). Appendix Accessories Note: The accessories are not included. Designation Description Product number Y-CONNECTOR screw Y-connector with screw terminals for EASY signal connection with 4-pin cable 4008321916686 OT 6/200-240/24 24 V power supply unit for flushmounted box installation, power supply range 220-240 V 4008321113269 Disposal Do not dispose of the device and batteries with household waste. Electronic devices must be disposed of at local recycling centres for waste electronic equipment in accordance with EU Directive 2002/96/EC on waste electrical and electronic equipment. Conformity with the relevant EU directives is confirmed by the CE symbol. Page 2 of 2