Description Purpose and application The EASY Color Drive wall operating unit is used together with an EASY RC radio receiver for the setting and functional control of connected EASY control units. The wall operating unit can be used to operate up to 8 channels, 8 lighting scenes and 4 sequences of a lighting system and to set the brightness, light colour and colour temperature. EASY Color Drive Function speed esc The wall operating unit transmits digitally coded radio signals to the receiver. The receiver converts the signals into the corresponding telegrams and transmits these to the connected control units. If the wall operating unit is connected to the EASY bus, the signals are transmitted directly to the control units through wires. The power supply is provided via an external power supply unit. Design See the operating instructions. Wall operating unit Fitting instructions Installation Safety instructions The wall operating unit must only be installed and put into operation by a qualified electrician. The applicable safety regulations and accident prevention regulations must be observed. CAUTION! Destruction of the wall operating unit and other devices through incorrect mounting! • Adhere to the connection diagram. • Do not wire the EASY bus terminals with an external voltage, especially not a mains voltage of 230 V. • Only connect the supply terminals to a DC voltage of 10-24 V. • Only work on the wall operating unit when it is deenergised. + 10-24 V DC - K J Attaching and connecting the wall operating unit Note: A flush-mounted box is needed for connection. For the combined EASY bus and DC supply connection, a flushmounted box with twice the depth is needed if the power supply unit is to be placed into the flush-mounted box behind the wall operating unit. H Shorten the connection wires so that they protrude approx. 5-6 cm from the flush-mounted box. Y-Connector Screw Strip the required connection wires by approx. 5 mm. Insu4 3 2 1 4 3 2 1 + H late any connection wires not needed. Pass the required connection wires through the centre opening of the mounting plate (H) on the back of the wall operating unit. Align the mounting plate (H) and attach it to the flush- mounted box. Ensure that it is seated securely, sliding the mounting plate up or down or to the left or right by a few millimetres if necessary. Connect and test the DC supply: CAUTION! Destruction of components connected to EASY bus! • Do not connect the DC supply to the EASY bus. L N DALI EASY III Easy Signal L N VIII 2009 EASY_Color_Drive_ma0908en_we1.01.indd OT EASY 60 II Easy signal GND (-) CH4+ (W) CH3+ (B) CH2+ (G) CH1+ (R) 24 V (+) CH1 (R-) CH2 (G-) CH3 (B-) CH4 (W-) GND (-) Connect the supplied 2-pin plug-in connector to the DC power supply and plug it into the corresponding socket (J) on the back of the wall operating unit. Test: Switch on the DC supply. à The LCD lighting must light up. Switch off the DC supply. Optional: Connect the EASY bus after the DC supply test was successful. Connect the supplied 4-pin plug-in connector to the EASY bus wires and plug it into the corresponding socket (K) on the back of the wall operating unit. Bend away the connecting wires in an S-shape and place the wall operating unit onto the mounting frame from above. Ensure that the wires do not press against the wall operating unit and are not pinched between the wall and wall operating unit. OSRAM GmbH Kunden Service Center Customer-Service-Center (CSC) Attach the wall operating unit using the supplied mounting Steinerne Furt 62 86167 Augsburg Germany screws (L). Tel : +49 (0) 1803 677 - 200 (kostenpflichtig / charges apply) Fax.: +49 (0) 1803 677 - 202 www.osram.com www.osram.de 40083214217776 4008321421777 L Page 1 of 2 Appendix Technical data External power supply 10-24 V DC / 6 VA Operating temperature 0 °C ... +40 °C Radio signal Frequency band 868.3 MHz FSK digital signal (OSRAM-specific coding) Functional range: • In the open air: approx. 100 m • In buildings: approx. 30 m Transmission power: max. 10 mW 103 mm 89 mm 24 mm Permissible conductor cross-section when connected via terminals Single and fine-wire conductors: 0.5 - 1.5 mm² (AWG 30 - AWG 14) Protection class III Protection type IP 20 Dimensions (L x W x H) 103 x 89 x 34 mm 10 mm Accessories Note: The accessories are not included. Designation Description Product number Y-CONNECTOR screw Y-connector with screw terminals for EASY signal connection with 4-pin cable 4008321916686 OT 6/200-240/24 24 V power supply unit for flushmounted box installation, power supply range 220-240 V 4008321113269 Disposal Do not dispose of the device with household waste. Electronic devices must be disposed of at local recycling centres for waste electronic equipment in accordance with EU Directive 2002/96/EC on waste electrical and electronic equipment. Conformity with the relevant EU directives is confirmed by the CE symbol. Page 2 of 2