EASY Color Drive

Description
Purpose and application
The EASY Color Drive wall operating unit is used together with
an EASY RC radio receiver for the setting and functional control
of connected EASY control units. The wall operating unit can
be used to operate up to 8 channels, 8 lighting scenes and 4
sequences of a lighting system and to set the brightness, light
colour and colour temperature.
EASY Color Drive
Function
speed
esc
The wall operating unit transmits digitally coded radio signals
to the receiver. The receiver converts the signals into the corresponding telegrams and transmits these to the connected
control units.
If the wall operating unit is connected to the EASY bus, the signals are transmitted directly to the control units through wires.
The power supply is provided via an external power supply unit.
Design
See the operating instructions.
Wall operating unit
Fitting instructions
Installation
Safety instructions
The wall operating unit must only be installed and put into operation by a qualified electrician. The applicable safety regulations
and accident prevention regulations must be observed.
CAUTION!
Destruction of the wall operating unit and other devices
through incorrect mounting!
• Adhere to the connection diagram.
• Do not wire the EASY bus terminals with an external
voltage, especially not a mains voltage of 230 V.
• Only connect the supply terminals to a DC voltage of
10-24 V.
• Only work on the wall operating unit when it is deenergised.
+
10-24 V DC -
K
J
Attaching and connecting the wall
operating unit
Note: A flush-mounted box is needed for connection. For the
combined EASY bus and DC supply connection, a flushmounted box with twice the depth is needed if the power supply
unit is to be placed into the flush-mounted box behind the wall
operating unit.
H
Shorten the connection wires so that they protrude approx.
5-6 cm from the flush-mounted box.
Y-Connector Screw
‚Strip the required connection wires by approx. 5 mm. Insu4
3
2
1
4
3
2
1
+
H
late any connection wires not needed.
ƒPass the required connection wires through the centre
opening of the mounting plate (H) on the back of the wall
operating unit.
„Align the mounting plate (H) and attach it to the flush-
mounted box. Ensure that it is seated securely, sliding the
mounting plate up or down or to the left or right by a few
millimetres if necessary.
…Connect and test the DC supply:
CAUTION!
Destruction of components connected to EASY bus!
• Do not connect the DC supply to the EASY bus.
L
N
DALI EASY III
Easy Signal
L
N
VIII 2009
EASY_Color_Drive_ma0908en_we1.01.indd
OT EASY 60 II
Easy signal
GND (-)
CH4+ (W)
CH3+ (B)
CH2+ (G)
CH1+ (R)
24 V (+)
CH1 (R-)
CH2 (G-)
CH3 (B-)
CH4 (W-)
GND (-)
Connect the supplied 2-pin plug-in connector to the DC
power supply and plug it into the corresponding socket (J)
on the back of the wall operating unit.
Test: Switch on the DC supply.
à The LCD lighting must light up. Switch off the DC supply.
†Optional: Connect the EASY bus after the DC supply test
was successful. Connect the supplied 4-pin plug-in connector to the EASY bus wires and plug it into the corresponding
socket (K) on the back of the wall operating unit.
‡Bend away the connecting wires in an S-shape and place
the wall operating unit onto the mounting frame from above.
Ensure that the wires do not press against the wall operating
unit and are not pinched between the wall and wall operating
unit.
OSRAM GmbH
Kunden Service Center
Customer-Service-Center (CSC)
ˆAttach the wall operating unit using the supplied mounting
Steinerne Furt 62
86167 Augsburg
Germany
screws (L).
Tel : +49 (0) 1803 677 - 200
(kostenpflichtig / charges apply)
Fax.: +49 (0) 1803 677 - 202
www.osram.com
www.osram.de
40083214217776
4008321421777
L
Page 1 of 2
Appendix
Technical data
External power supply
10-24 V DC / 6 VA
Operating temperature
0 °C ... +40 °C
Radio signal
Frequency band 868.3 MHz
FSK digital signal (OSRAM-specific coding)
Functional range:
• In the open air: approx. 100 m
• In buildings: approx. 30 m
Transmission power: max. 10 mW
103 mm
89 mm
24 mm
Permissible conductor
cross-section when connected via terminals
Single and fine-wire conductors:
0.5 - 1.5 mm²
(AWG 30 - AWG 14)
Protection class
III
Protection type
IP 20
Dimensions
(L x W x H)
103 x 89 x 34 mm
10 mm
Accessories
Note: The accessories are not included.
Designation
Description
Product number
Y-CONNECTOR screw
Y-connector with screw terminals
for EASY signal connection with
4-pin cable
4008321916686
OT 6/200-240/24
24 V power supply unit for flushmounted box installation,
power supply range 220-240 V
4008321113269
Disposal
Do not dispose of the device with household waste.
Electronic devices must be disposed of at local
recycling centres for waste electronic equipment in
accordance with EU Directive 2002/96/EC on waste
electrical and electronic equipment.
Conformity with the relevant EU directives is
confirmed by the CE symbol.
Page 2 of 2