www.osram.de/LED-Systeme DRAGONpuck® - DP35 Preliminary Data Sheet Benefits Efficacy alternative to MR11 halogen lamps Compact High-Flux LED light source Efficacy up to 97 lm/w Applications Hospitality - Restaurant - Hotel Shop - Shelf & Undercabinet Technical Operating Data Product Color Number of LEDs Current [mA]* Power [W]* Radiance Angle [°]* Color Temp. Lum. Intensity [K]* [cd]* DP35-W4F-9-857-L36 white 4 700 9,2 36 5700 1600 DP35-W4F-7-857-L36 white 3 700 6,9 36 5700 1200 DP35-W4F-9-827-L36 white 4 700 9,2 36 2700 1330 DP35-W4F-7-827-L36 white 3 700 6,9 36 2700 1000 *) All Data are related to the entire module Due to the special conditions of the manufacturing processes of LED the typical data of technical parameters can only reflect statistical figures and do not necessarily correspond to the actual parameters of each single product which could differ from the typical data +) Preliminary Data **) only available in APAC Technical Features Dimensions: H: 12 mm, Ø: 51 mm Dimmable with OPTOTRONIC® OT LTCS family and Assembly with M3 screw on metallic heat sink OPTORONIC® OT9 DIM / OT18 DIM Module ready to use with 200 mm cables / AWG 22 double pole cable. Color Rendering index CRI typ. 85 Operation only with constant current control gears Shock and vibration proof according to IEC 60068-2 (see page 3 for recommendations) Best efficacy in combination with OSRAM OPTOTRONIC® control gears DP35 – 17.08.2014 Page 1 von 4 Up to 50,000 hrs lifetime @L70 @ Tc max www.osram.de/LED-Systeme Minimum and Maximum Ratings Product Operating Temperature Storage Temperature Max. Current[A]* Reverse Voltage Forward Voltage [V dc]* [V dc]* 0,85 24 11,92 – 15,12 -30 … 90 0,85 24 8,94 – 11,34 -30 … 90 -30 … 90 0,85 24 11,92 – 15,12 -30 … 90 -30 … 90 0,85 24 8,94 – 11,34 at Tc-Point [C°]* [C°]* DP35-W4F-9-857-L36 -30 … 90 -30 … 90 DP35-W4F-7-857-L36 -30 … 90 DP35-W4F-9-827-L36 DP35-W4F-7-827-L36 The module is designed to work with current sources. The maximum output voltage may not exceed 100 V DC. Reverse operation is not allowed and may destroy the module. *) Exceeding maximum ratings for operating and storage temperature will reduce expected life time or destroy the LED Module. Exceeding maximum ratings for operating current will cause hazardous overload and will likely destroy the LED Module. Several modules may be connected in series up to themaximum voltage of 100 V DC (outside SELV limits). The temperature of the LED module must be measured at the Tc-point according to EN60598-1 in a thermally constant status with a temperature sensor or a temperature sensitive label. For exact location of the Tc-point see drawing below. **) only available in APAC Drawings DRAGONpuck DP35 operated with 350mA, 500mA sowie 700mA DP35 – 17.08.2014 Page 2 von 4 www.osram.de/LED-Systeme Safety Information The LED module itself and all its components must not be mechanically stressed. Assembly must not damage or destroy conducting paths on the circuit board. In order to drive OSRAM LED-Modules safely, it is absolutely necessary to operate them with an electronically stabilised power supply protecting against short circuits, overload and overheating. To also ease the luminaire/installation approval, electronic control gear for LED or LED modules should carry the CE mark and be ENEC certified. In Europe the declarations of conformity must include the following standards: CE: EC 61347-2-13, EN 55015, IEC 61547 and IEC 61000-3-2 - ENEC: 61347-2-13 and IEC/EN 62384. Also check for the mark of an independent authorized certification institute. Please see the relevant brochure for more detailed information (see "Related and Further Information"). OSRAM OPTOTRONIC® electronic control gear complies to all relevant standards and guarantees safe operation. Installation of LED modules (with power supplies) needs to be made with regard to all applicable electrical and safety standards. Only qualified personnel should be allowed to perform installations. Observe correct polarity! Depending on the product incorrect polarity will lead to emission of red or no light. The module can be destroyed! Correct polarity immediatelly! (see "reverse voltage", page 2). Serial connection is highly recommended as safe electrical operation mode.Parallel connection is not recommended. Unbalanced voltage drop can cause hazardous overload and damage the LED module. Pay attention to ESD steps when mounting the module. The module, as manufactured, has no conformal coating and therefore offers no inherent protection against corrosion. Damage by corrosion will not be honored as a materials defect claim. It is the user's responsibility to provide suitable protection against corrosive agents such as moisture and condensation and other harmful elements. Recommended OPTOTRNIC® devices (non conclusive): OT 9/200-240-350 OT 9/100-120/350 E OT 9/10-24/350 DIM OT 9/220-240/350 DIM OT 18/200-240/700 DIM OT 35/220-240/700 LTCS OT 45/220-240/700 LTCS OTe 35/200-240/700 Recommended Light Management Systems OTi DALI 2x700 CS OT DMX 3x350 DIM LI OT DMX 6x350/700 DIM SO OT DMX 12x350/700 DIM SO DP35 – 17.08.2014 Page 3 von 4 www.osram.de/LED-Systeme Ordering Guide Productgroup Product EAN* S-Unit* DRAGONpuck® DP35-W4F-9-857-L36 4008321976222 16 DRAGONpuck® DP35-W4F-7-857-L36 4008321976185 16 DRAGONpuck® DP35-W4F-9-827-L36 4008321976208 16 DRAGONpuck® DP35-W4F-7-827-L36 4008321976161 16 Heat sink CPDPHS-51 4008321975829 16 *) EAN: Ordering number per single module S-Unit: Modules per shipping unit **) only available in APAC Note: Typical performance data are subject to change without any further notice, particularly as LED technology evolves. Sales and Technical Support OSRAM GmbH Sales and technical support is given by the local OSRAM subsidiaries. Marcel-Breuer-Straße 6 80807 Munich, Germany www.osram.com +49.89.6213-0 (Headquarter) +49.89.6213-6000 (Customer-Service-Center) On the OSRAM website all subsidiaries are listed with complete address and phone numbers Related and Further Information A new approach to light OSRAM LED Systeme OPTOTRONIC® Technical Guide OPTOTRONIC® Data sheets Eulumdat Files New standards for LED control gear DP35 – 17.08.2014 153 S006 GB www.osram.de/led-systeme 130 T008 DE www.osram.de/evg-downloads http://catalog.myosram.com www.osram.de/led-systeme-downloads www.osram.de/evg-downloads Page 4 von 4