Technical Operating Data
Product
Color
Number
of LEDs
Current
[mA]*
Power
[W]*
Radiance
Angle [°]*
Color Temp. Lum. Intensity
[K]*
[cd]*
DP35-W4F-9-857-L36
white
4
700
9,2
36
5700
1600
DP35-W4F-7-857-L36
white
3
700
6,9
36
5700
1200
DP35-W4F-9-827-L36
white
4
700
9,2
36
2700
1330
DP35-W4F-7-827-L36
white
3
700
6,9
36
2700
1000
*) All Data are related to the entire module
Due to the special conditions of the manufacturing processes of LED the typical data of technical parameters can only reflect statistical figures and do not necessarily
correspond to the actual parameters of each single product which could differ from the typical data +) Preliminary Data **) only available in APAC
Technical Features
 Dimensions: H: 12 mm, Ø: 51 mm
 Dimmable with OPTOTRONIC® OT LTCS family and
 Assembly with M3 screw on metallic heat sink
OPTORONIC® OT9 DIM / OT18 DIM
 Module ready to use with 200 mm cables / AWG 22
double pole cable.
 Color Rendering index CRI typ. 85
 Operation only with constant current control gears
 Shock and vibration proof according to IEC 60068-2
(see page 3 for recommendations)
 Best efficacy in combination with OSRAM
OPTOTRONIC® control gears
DP35 – 17.08.2014
Page 1 von 4
 Up to 50,000 hrs lifetime @L70 @ Tc max
www.osram.de/LED-Systeme
Minimum and Maximum Ratings
Product
Operating Temperature
Storage Temperature Max. Current[A]*
Reverse Voltage
Forward Voltage
[V dc]*
[V dc]*
0,85
24
11,92 – 15,12
-30 … 90
0,85
24
8,94 – 11,34
-30 … 90
-30 … 90
0,85
24
11,92 – 15,12
-30 … 90
-30 … 90
0,85
24
8,94 – 11,34
at Tc-Point [C°]*
[C°]*
DP35-W4F-9-857-L36
-30 … 90
-30 … 90
DP35-W4F-7-857-L36
-30 … 90
DP35-W4F-9-827-L36
DP35-W4F-7-827-L36
The module is designed to work with current sources. The maximum output voltage may not exceed 100 V DC. Reverse operation is not allowed
and may destroy the module.
*) Exceeding maximum ratings for operating and storage temperature will reduce expected life time or destroy the LED Module.
Exceeding maximum ratings for operating current will cause hazardous overload and will likely destroy the LED Module. Several modules may be connected in series
up to themaximum voltage of 100 V DC (outside SELV limits).
The temperature of the LED module must be measured at the Tc-point according to EN60598-1 in a thermally constant status with a temperature sensor or a temperature
sensitive label. For exact location of the Tc-point see drawing below. **) only available in APAC
Drawings
DRAGONpuck DP35 operated with 350mA, 500mA sowie 700mA
DP35 – 17.08.2014
Page 2 von 4
www.osram.de/LED-Systeme
Safety Information
 The LED module itself and all its components must not be mechanically stressed.
 Assembly must not damage or destroy conducting paths on the circuit board.
In order to drive OSRAM LED-Modules safely, it is absolutely necessary to operate them with an electronically
stabilised power supply protecting against short circuits, overload and overheating.
To also ease the luminaire/installation approval, electronic control gear for LED or LED modules should carry the CE mark
and be ENEC certified. In Europe the declarations of conformity must include the following standards:
CE: EC 61347-2-13, EN 55015, IEC 61547 and IEC 61000-3-2 - ENEC: 61347-2-13 and IEC/EN 62384.
Also check for the mark of an independent authorized certification institute.
Please see the relevant brochure for more detailed information (see "Related and Further Information").
OSRAM OPTOTRONIC® electronic control gear complies to all relevant standards and guarantees safe operation.
 Installation of LED modules (with power supplies) needs to be made with regard to all applicable electrical and safety
standards. Only qualified personnel should be allowed to perform installations.
 Observe correct polarity!
Depending on the product incorrect polarity will lead to emission of red or no light. The module can be destroyed! Correct
polarity immediatelly! (see "reverse voltage", page 2).
 Serial connection is highly recommended as safe electrical operation mode.Parallel connection is not recommended.
Unbalanced voltage drop can cause hazardous overload and damage the LED module.
 Pay attention to ESD steps when mounting the module.
 The module, as manufactured, has no conformal coating and therefore offers no inherent protection against corrosion.
 Damage by corrosion will not be honored as a materials defect claim. It is the user's responsibility to provide suitable
protection against corrosive agents such as moisture and condensation and other harmful elements.
 Recommended OPTOTRNIC® devices (non conclusive):
OT 9/200-240-350
OT 9/100-120/350 E
OT 9/10-24/350 DIM
OT 9/220-240/350 DIM
OT 18/200-240/700 DIM
OT 35/220-240/700 LTCS
OT 45/220-240/700 LTCS
OTe 35/200-240/700
 Recommended Light Management Systems
OTi DALI 2x700 CS
OT DMX 3x350 DIM LI
OT DMX 6x350/700 DIM SO
OT DMX 12x350/700 DIM SO
DP35 – 17.08.2014
Page 3 von 4
www.osram.de/LED-Systeme
Ordering Guide
Productgroup
Product
EAN*
S-Unit*
DRAGONpuck®
DP35-W4F-9-857-L36
4008321976222
16
DRAGONpuck®
DP35-W4F-7-857-L36
4008321976185
16
DRAGONpuck®
DP35-W4F-9-827-L36
4008321976208
16
DRAGONpuck®
DP35-W4F-7-827-L36
4008321976161
16
Heat sink
CPDPHS-51
4008321975829
16
*) EAN: Ordering number per single module
S-Unit: Modules per shipping unit
**) only available in APAC
Note: Typical performance data are subject to change without any further notice, particularly as LED technology evolves.
Sales and Technical Support
OSRAM GmbH
Sales and technical support is given by the local OSRAM
subsidiaries.
Marcel-Breuer-Straße 6
80807 Munich, Germany
www.osram.com
+49.89.6213-0 (Headquarter)
+49.89.6213-6000 (Customer-Service-Center)
On the OSRAM website all subsidiaries are listed with complete
address and phone numbers
Related and Further Information

A new approach to light

OSRAM LED Systeme

OPTOTRONIC® Technical Guide


OPTOTRONIC® Data sheets
Eulumdat Files

New standards for LED control gear
DP35 – 17.08.2014
153 S006 GB
www.osram.de/led-systeme
130 T008 DE www.osram.de/evg-downloads
http://catalog.myosram.com
www.osram.de/led-systeme-downloads
www.osram.de/evg-downloads
Page 4 von 4